| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC AIR FORCE ROAD GORAIMARI HALESHWAR TEZPUR SONITPUR ASSAM 784104 | SONITPUR | ASSAM | 784104 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹22.5 L+₹4.0 L (21.4%)Rejected-Finance | L2 | Rejected-Finance other than lowest bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
17 May 2021, 6:00 pmClosed
GE AF TEZPUR
GE AF TEZPUR AIRFORCE STATION TEZPUR SALONIBARI ASSAM
REPAIR/REPLACEMENT LA , FLAME PROOF LIGHT, FLAMPROOF EXHAUST FANS, MCB, DB AND SUB MAIN WIRING AT AF STATION UNDER GE (AF) TEZPUR
2021_MES_438243_1
8565/e8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
AIRFORCE STATION TEZPUR
CLASS E
CATEGORY b(I)
6 documents required · 6 mandatory
₹500
GE AF TEZPUR
₹40,000
Yes
24 May 2021
24 Apr 2021
19 May 2021
25 Apr 2021
17 May 2021
3 May 2021
25 Apr 2021 - 30 Apr 2021
Amount
M&L Air termination, single pointed, copper rod 12mm dia and 300mm long and including taking down old unserviceable air termination rod complete all as specified and directed
S&F 40 mm bore galvanized steel tubing, medium grade fixed to poles/Walls etc, for holding Air termination with coupling and including taking down old unservisable GI steel tubing complete all as specified and directed.
Materials & Labour point wiring complete with 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor FRLS cable 1100 volts grade, single core, drawn through and including stove enamelled steel conduit not less than 20mm dia with all flame proof accessories such as junction box, MS coupling, unions branch, reducers, elbow, sealing conduit etc. including including 1.5 sqmm PVC insulated unsheathed multistranded copper conductor FRLS Cable (green colour) 1100 volts grade, single core as earth continuity conductor connected to common earth dolly for one light point / fan Point controlled by one one way switch and including taking down carefully copper/ aluminium point wiring (light/fan) complete inclusive of all fittings such as switches, ceiling roses, sockets, fittings etc. removing materials from site and making good disturbed surfaces of floors/walls/ceiling etccomplete all as specified and directed.
All as per ser item No 3 here-in-before but wiring with 4.0 sqmm and 4 Sqmm PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor cable 1100 Volts grade, single core earth continuity conductor connected to common earth dolly for 3/5 pin 6/16 Amps socket outlet on independent board.
Supply and fix switch flame proof rotary type with termination box in LM6, 16Amps, single pole 250 volts complete all as specified and as directed. Note : taking down catered in item no 3 & 4 above
Supply and fix flame proof switch socket & plug combination in LM6 cable termination box in LM6, 16 Amps, 250 volts, 2p+earth complete all as specified and as directed. Note : taking down catered in item no 3 & 4 above
Supply and fix flame proof 4 way junction box round type aluminium die cast complete all as specified and as directed. Note : taking down catered in item no 3 & 4 above
S&F LED tube light fittings 1x20W flame proof type FLP-WP made of aluminium alloy LM6, with electronic driver, bipin holder, connected block, etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all spcified and as directed. Note : taking down catered in item no 3 & 4 above
S&F LED tube light fittings 2x20W flame proof type FLP-WP made of aluminium alloy LM6, with electronic driver, bipin holder, connected block, etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all spcified and as directed. Note : taking down catered in item no 3 & 4 above
S&F BULK HEAD flame proof LED light fitting flame proof type FLP-WP of 1 x 26 watt built in control gear box made of aluiminium alloy LM6,with all accessories, electronic driver, lamp holders,etc internally prewired complete all spcified and as directed. Note : taking down already catered in item no 3 & 4 above
Refixing of flame proof light fitting of any type and size with complete electrical connection complete all as specified and as directed. Note : taking down already catered in item no 3 & 4 above
S&F as in repair LED tube light fittings 1x20W flame proof type FLP-WP made of aluminium alloy LM6, with electronic driver, bipin holder, connected block, etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all spcified and as directed.
S&F as in repair LED tube light fittings 2x20W flame proof type FLP-WP made of aluminium alloy LM6, with electronic driver, bipin holder, connected block, etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all spcified and as directed.
S&F as in repair BULK HEAD flame proof LED light fitting flame proof type FLP-WP of 1 x 26 watt built in control gear box made of aluiminium alloy LM6,with all accessories, electronic driver, lamp holders,etc internally prewired complete all spcified and as directed.
S&F flame proof 6 way distribution board made of stainless steel LM6, complete fixing acessoreies and taking out existing unserviceable flame proof DBs etc any number of ways including MCB etc removing materials from site and making good disturbed surfaces of floors/ walls/ ceiling etc all as specified and directed.
Materials and labour for two single core PVC insulated unsheathed cable 6.0 sqmm with multistranded copper conductor FRLS cable,1100 volts grade drawn and including Rigid Steel Conduit 20 mm bore and continuous earth wire of single core PVC insulated, unsheathed cable 6.0 sqmm with multistranded copper conductor 1100 volts grade for sub main wiring including taking down old unserviceable sub main wiring of any size and making good disturbed surfaces complete all as specified and directed. Note : Two run of wiring cable, one run of earth wire and one run of rigid steel conduit shall be measured as one unit.
Materials and labour two single core PVC insulated unsheathed cable 4.0 sqmm with multistranded copper conductor FRLS cable,1100 volts grade drawn through and including Rigid Steel Conduit 20 mm bore with accessories and continuous earth wire of single core PVC insulated, unsheathed cable 4.0 sqmm with multistranded copper conductor 1100 volts grade for sub main wiring including taking down old unserviceable sub main wiring of any size and making good disturbed surfaces complete all as specified and directed. Note : Two run of wiring cable, one run of earth wire and one run of rigid steel conduit shall be measured as one unit.
S&F sheet metal enclosures MCB DB 4 way SPN, double door, with 200 Amp rated bus bar including earth & neutral link, complete fixing acessoreies and taking out existing unserviceable MCB DB SPN etc any number of ways including MCB etc removing materials from site and making good disturbed surfaces of floors/ walls/ ceiling etc all as specified and directed.
S&F sheet metal enclosures MCB DB 8 way SPN, double door, with 200 Amp rated bus bar including earth & neutral link, complete fixing acessoreies and taking out existing unserviceable MCB DB SPN etc any number of ways including MCB etc removing materials from site and making good disturbed surfaces of floors/ walls/ ceiling etc all as specified and directed.
S&F sheet metal enclosures MCB DB 4 way TPN, double door, Vertical type , with 200 Amp rated bus bar including earth & neutral link, IP 54 protection, complete fixing acessoreies and taking out existing unserviceable MCB DB SPN etc any number of ways including MCB etc removing materials from site and making good disturbed surfaces of floors/ walls/ ceiling etc all as specified and directed.
Supply and fix Miniature circuit breaker (MCBs) Single Pole 6 to 32 Amps, 10KA, 240 Volts, , 'C' curve complete all as specified and directed. Note : taking down catered in item no 19 & 20 above
Supply and fix Miniature circuit breaker (MCBs) SPN 6 to 32 Amps 10KA ‘C’ series 240 volts complete all as specified and as directed. Note : taking down catered in item no 19 & 20 above
Supply and fix Miniature circuit breaker (MCBs) SPN 40 Amps 10KA, 240 Volts, 'C' curve complete all as specified and directed. Note : taking down catered in item no 19 & 20 above
Supply and fix Miniature circuit breaker (MCBs) TPN, 415 Volts, 63KA, breaking capacity 'C' curve complete all as specified and directed. Note : taking down catered in item no 19 & 20 above
Supply and fix backlite blanking plate in lieu of MCB's complete all as specified and directed.
Material and labour sub main wiring with two single core PVC insulated unsheathed cable 6.00 Sqmm (Nominal area) with multistranded FRLS copper conductor cable, 1100 volts grade drawn through and including PVC casing & capping of size not less than 25mm with accessories and earth continuity conductor of single core PVC insulated, unsheathed cable 6.0 Sqmm (Nominal area) with multistranded copper conductor, 1100 volts grade for sub main wiring and including taking down old unserviceable sub main wiring of any size and making good disturbed surfaces complete all as specified and directed. Note:- (i) Two run of wiring cable, one run of earth wire and one run of PVC casing & capping shall be measured as one unit.
Material and labour sub main wiring with twosingle core PVC insulated unsheathed cable 4.00 Sqmm (Nominal area) with multistranded FRLS copper conductor cable, 1100 volts grade drawn through and including PVC casing & capping of size not less than 25mm with accessories and earth continuity conductor of single core PVC insulated, unsheathed cable 4.0 Sqmm (Nominal area) with multistranded copper conductor, 1100 volts grade for sub main wiring and including taking down old unserviceable sub main wiring of any size and making good disturbed surfaces complete all as specified and directed. Note:- (i) Two run of wiring cable, one run of earth wire and one run of PVC casing & capping shall be measured as one unit.
Material and labour sub main wiring with two single core PVC insulated unsheathed cable 4.0 sqmm (Nominal area) with multistranded FRLS copper conductor cable, 1100 volts grade, drawn through existing PVC concealled conduit with accessories and continious earth wire of single core PVC insulated, unsheathed cable 4.0 sqmm (Nominal area) with ultistranded copper conductor (green), 1100 volts grade for sub main wiring and including taking down old unserviceable sub main wiring of any size and making good disturbed surfaces complete all as specified and directed. Note:- (i) Two run of wiring cable, one run of earth wire shall be measured as one unit.
Material and labour sub main wiring with twosingle core PVC insulated unsheathed cable 6.0 sqmm (Nominal area) two run with multistranded FRLS copper conductor cable, 1100 volts grade, drawn through existing PVC concealled conduit with accessories and continious earth wire of single core PVC insulated, unsheathed cable 6.0 sqmm (Nominal area) with ultistranded copper conductor (green)one run 1100 volts grade for sub main wiring and including taking down old unserviceable sub main wiring of any size and making good disturbed surfaces complete all as specified and directed. Note:- (i) Two run of wiring cable, one run of earth wire shall be measured as one unit.
Dressing of Sub main wiring of any size by dismantiling of existing Point wiring/Sub main wiring and old broken casing caping/steel conduit replace with new casing caping/steel conduit of existing size from site and making good disturbed surfaces of floors/walls/ceiling etc complete all as directed. Note: Casing caping/Steel conduit shall be measured and paid seprately.
Supply only Casing caping of size 25 mm.
Supply only Steel conduit of size 20 mm.
M&L rewinding of unserviceable flame proof ceiling fan rotor of any make and 1200 mm sweep size with original gauge of super enamelled copper wire after necessary cutting, removing burnt winding of flame proof Ceiling Fan from core and cleaning all parts including insulation materials, varnishing, heating and replacement of unserviceable spare parts such as capacitor, bearing etc and painting the fan with blade and including testing on full load current all as directed. Note:- (i) Taking down of ceiling fan and refixing shall be included in the quoted rate. (ii) Unit rate of this item is including the cost of transportation charges from original site to workshop and back from work shop to original site.
M&L rewinding of unserviceable flame proof exhaust fan rotor of any make and any sweep size with original gauge of super enamelled copper wire after necessary cutting, removing burnt winding of flame proof exhaust Fan from core and cleaning all parts including insulation materials, varnishing, heating and replacement of unserviceable spare parts such as capacitor, bearing etc and painting the fan with blade and including testing on full load current all as directed. Note:- (i) Taking down of ceiling fan and refixing shall be included in the quoted rate. (ii) Unit rate of this item is including the cost of transportation charges from original site to workshop and back from work shop to original site.
Material and Labour for repair and conversion of conventional light to LED light 1x20W in existing single side flame proof light fitting suitable for T8 & T5 fittings with spray painting of outer fixture complete with all accessories and complete connection with wiring and make good of all distubed surfaces complete all as specified as directed.
Material and Labour for repair and conversion of conventional light to LED 2x20W light in existing double side flame proof light fitting suitable for T8 & T5 fittings with spray painting of outer fixture complete with all accessories and complete connection with wiring and make good of all distubed surfaces complete all as specified as directed.
Material and Labour for repair and conversion of conventional light to LED light 1x26w in existing bulk head flame proof light fitting with spray painting of outer fixture complete with all accessories and complete connection with wiring and make good of all distubed surfaces complete all as specified as directed.
Supply and fixing as in repair Knobs of flame proof rotary type switch complete all as specified and as directed.
Supply and fix in repair integral LED aviation light luminaries comprising of aluminium housing with polycarbonate enclosure Make : Bajaj cat pt No 110731 Type BGAV 302 LED or equivalent in Havells/Cormpton Greaves/Philips/Jaquar/HPL.
Supply and fix in repair LED 45 W post top made in die cast aluminium with decorative clear opal acrylic diffuser & IP 65 protection.
Supply and fix as in repair Miniature circuit breaker (MCBs) Single Pole, 240 Volts, 10KA, 6 to 32 Amps, 'C' curve complete all as specified and directed.
Supply and fix as in repair MCB SPN 6 to 32 Amps 10KA ‘C’ series 240 volts complete all as specified and as directed.
Supply and fix as in repair Miniature circuit breaker (MCBs) SPN 40 Amps, 240 Volts, 10KA, 'C' curve complete all as specified and directed.
Supply and fix as in repair Miniature circuit breaker (MCBs) TPN 63KA, 415 Volts, breaking capacity 'C' curve complete all as specified and directed.
Supply and fix in repair sheet metal enclosure SPN with two pin earth plug and socket complete with one single pole MCB 20 Amps, 10KA, 240 Volts incl removing the existing unserviceable metal plug socket.
Shri A. K. Goswami
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .