Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance A 20 SEN COLONI JAIPUR RAJASTHAN 302016 | JAIPUR | RAJASTHAN | 302016 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance 31 A SHIVA COLONY II NEW SANGANER ROAD JAIPUR 302013 | JAIPUR | JAIPUR | RAJASTHAN | 302013 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance 284 CHAND KUTI OPP SHIV TEMPLE RATANADA JODHPUR RAJ | JODHPUR | JODHPUR | RAJASTHAN | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Not Admitted-Fee/PreQual/Technical/Finance | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
Tender Value
₹1.2 Cr
Closing Date
15 Feb 2021, 6:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
xen electric-II
JDA JODHPUR
AIR CONDITIONING WORK FOR SOUTH PAVILLION AT BARKATULLAH KHAN STADIUM AT JODHPUR
2021_JDAJO_211460_1
JoDA/Nit-09/Electric-II/20-21
Open Tender
Electrical and Maintenance Works
Percentage
270 days
JODHPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
SECRETRY JDA JODHPUR 1000 AND MD RISL JAIPUR1000
Exempted
16 Feb 2021
27 Jan 2021
16 Feb 2021
27 Jan 2021
15 Feb 2021
27 Jan 2021
Amount
Supply Installation Testing Commissioning of VRF system, The system shall be air-cooled, direct expansion type central air conditioning system consisting of Variable Refrigerant Flow Condensing unit (Outdoor Unit) and connected to it one or more Evaporator (Indoor Units) for cooling and heating operation. Each having the capability of individual set point control & the condensing unit should incorporate multiple scroll compressors to obtain minimum 10% to 100% capacity control. Refrigerant used for system should be R410A.
The condensing unit shall be capable of assessing the requirement of liquid refrigerant flow of each evaporating unit at all times by means of a micro computer control expansion valve and generating the required total flow of refrigerant liquid for supply to the evaporator units.Outdoor Units should be modular in type and should be equipped with Inverter Scroll Compressor
Outdoor unit should consists of DC variable speed motor for condenser fan to reduce input power, auto check function for connection error, auto address setting. Unit should assess demand function automatically and perform with the help of Central Station. Units having Noise reduction mode will be preferred but must be having back up operation function for emergency to avoid complete stop. Outdoor unit should have feature of Rotation Operation function of Compressor to distribute load. The condenser coil should be with Al/Cu internally grooved Cu tubes, mechanically bonded to super slit aluminum fins.
Outdoor unit must have automatic judgment function to check weather or not the refrigerant amount is sufficient in one refrigerant cycle. Reliable Transmission system should be used between outdoor and indoor units. including topping R410A gas as per site requirements and compny specifications to get the desired inside temprature and proper working of the entire AC system Make-Daikin, Mitsubhishi heavy,Toshiba, O general
44 HP Heat Pump Type (Cooling & Heating )
SITC of indoor unit of various type and capacity as mentioned below. The unit shall be equipped with suitable electronic expansion valve, which can communicate with the controller in the condensing unit, multispeed motor, self diagnostic type cordless remote controller, coil section with DX coil, outer cabinet, drain pan, built in drain pump, drain water lift-up mechanism insulation, pipe connections, imported Y-joints & header, Tee, fresh air intake connector for cassettes etc. of various capacity as per specification and drawings & Make-Daikin, Mitsubhishi heavy,Toshiba, O general
4 WAY CASSETTE TYPE IDU
2.0 TR 4Way Cassette AC
2.5 TR 4Way Cassette AC
2.8 TR 4Way Cassette AC
3.0 TR 4Way Cassette AC
3.5 TR 4Way Cassette AC
4.0 TR 4Way Cassette AC
HI WALL TYPE IDU
1.2 TR Split AC
1.4 TR Split AC
1.6 TR Split AC
2.0 TR Split AC
SITC of Ductable Indoor AC with Corded Remote and Refnet Joint . The unit shall be equipped with suitable electronic expansion valve, which can communicate with the controller in the condensing unit. The fan shall of the dual suction multi blade type and statically and dynamically balanced to ensure low noise and vibration free operation. Controls shall be provided to maintain the set room temperature within close tolerance limits.Units must be compact type in dimension with min 3 speeds of fan and min 400 CFM / TR to handle high CFM load .Make-Daikin, Mitsubhishi heavy,Toshiba, O general
8.0 HP/6.4 TR Ductable type unit with Minimum 2640 CFM
5.0HP/4.0 TR Ductable type unit with Minimum 1325CFM
SITC of Treated fresh air units with Corded Remote and Refnet Joint . The unit shall be equipped with suitable electronic expansion valve, which can communicate with the controller in the condensing unit. The fan shall of the dual suction multi blade type and statically and dynamically balanced to ensure low noise and vibration free operation.Units must be compact type in dimension with min 3 speeds of fan and min 150 CFM / TR to handle high CFM load .Make-Daikin, Mitsubhishi heavy,Toshiba, O general
8 HP/6.3 TR Ductable type unit with Maximum 988 CFM
Supply, installation, testing & commissioning Refrigerant 'Y'Joint of various sizes required for distribution of refrigerant in copper piping etc. complete as per specificationss Make-Daikin, Mitsubhishi heavy,Toshiba, O general.
Supply, Installation, testing & commissioning of cordless or corded remote controls separate for each indoor units. Make-Daikin, Mitsubhishi heavy,Toshiba, O general
Supply, Installation, testing & commissioning of main central remote controller system with coloured LCD display touch panel suitable for above mentioned Indoor Units ( 100 nos) to operate/ monitor temperature setting etc Make-Daikin, Mitsubhishi heavy,Toshiba, O general
Supply, installation , testing and commissioning of Interconnecting refrigerant copper pipe work suitable for R-410A refrigerant with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room.All piping shall be properly supported with MS,GI STUDS/CLAMPS/HANGERS .All piping shall be pressure tested for 1.5 times the working pressure. . The refregerant pipes running in vertical shaft shall be supported on MS angle and wooden saddle at every 1000 mm distance and the pipes which are running horizontally above the false ceiling should be supported on MS angle/slotted angle at every 1000 mm distance.Exposed pipe shall be covered with 0.36mm Aluminium cladding for protection. Make:- Copper pipe- Mandev/Maxflow/Papdiwal Make:- Insulation- Armaflex/Aflex/Superion.
6.4mm Dia with 19mm thick insulation
9.5mm Dia with 19mm thick insulation
12.7mm Dia with 19mm thick insulation
15.9mm Dia with 19mm thick insulation
19.1mm Dia with 19mm thick insulation
22.2mm Dia with 19mm thick insulation
28.6mm Dia with 19mm thick insulation
41.3mm Dia with 19mm thick insulation
Supply, installation, testing and commissioning of rigid heavy duty UPVC drain piping suitable for 10 kg/ sqcm pressure rating for indoor units complete with necessary elbow, tees, reducers, brass connector between GI and PVC pipe etc.All drain piping shall be insulated with 6mm thick sleeve of nitrile rubber Superlon/ Aflex/ K flex make having K value of 0.03 W/mK at 10 Deg C mean temperature and minimum density of 50 kg/ cum.
25 mm dia
32 mm dia
50 mm dia
Providing and fixing fire retardant nonporous double layer flexible connection between each unit and duct.
Supplying, handling, laying, testing and commissioning of control cum transmission wiring (Sheilded) of 2 core x 1.5 sqmm copper in suitable conduits between indoor and out door unit Make:- Finolex/Polycab/KEI/RR Kabel.
Bidder Name
Amount
Kiran Enterprises(GSTN-08AATFK3928Q1ZB)
BALAJI REFRIGERATION and ELECTRICALS(GSTN-08AUUPS3553LIZP)
bhawani air systems(GSTN-08CDPPS0264J1Z1)
NIRMAN ELECTRIC STORE(GSTN-08AOIPS5332P1Z8)
NIRMAN ELECTRIC STORE
bhawani air systems
Kiran Enterprises
bhawani air systems
NIRMAN ELECTRIC STORE
Kiran Enterprises
stage.html
html • 0.03 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .