Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 LAccepted-AOC NICHUPATY BOLPUR P WEST BENGAL BIRBHUM PIN 731204 | BOLPUR | BIRBHUM | WEST BENGAL | 731204 | L1 | Accepted-AOC L1 | |
| 2 | L2₹3.4 L+₹14,695 (4.52%)Rejected-Finance NABAJIBAN 1 NABAJIBAN COLONY BISHARPARA KOLKA 700158 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700158 | L2 | Rejected-Finance L2 | |
| 3 | L3₹3.4 L+₹16,375 (5.04%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹3.4 L+₹16,965 (5.22%)Rejected-Finance P O SASINDA VILL KASHIYA P S BELDA WEST MEDINIPUR PIN 721445 | BELDA | PASCHIM MEDINIPUR | WEST BENGAL | 721445 | L4 | Rejected-Finance L4 |
Tender Value
Refer Docs
EMD Value
₹6,838
Closing Date
7 Aug 2025, 12:00 pmClosed
AE/BESD-I, Room-14, Purta Bhavan, Salt Lake
AE/BESD-I, Room-14, Purta Bhavan, Salt Lake
Supply, Installation, Testing and commissioning of 1.5/1.8 TR single phase split type air conditioning machine for Science and Technology Deptt. at 4th floor in East Block in Bikash Bhawan.
2025_WBPWD_885016_1
WBPWD/AE/BESD-I/e-NIQ-08/25-26 2nd Call
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
Bikash Bhawan
Please refer Tender documents.
5 documents required · 5 mandatory
₹6,838
22 Aug 2025
30 Jul 2025
11 Aug 2025
31 Jul 2025
7 Aug 2025
31 Jul 2025
Amount
SITC of (1.5-1.8 TR) Split type AC machines having cooling capacity range (5.2 kw to 5.3 kw), with fixed speed rotary compressor, refrigerant gas R32, BEE star rating-2 (Minimum) (ISEER range 3.5 to 5), Air flow range CFM (560-600), both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) Cordless Remote Arrangement with all modernized provision of temperature setting , Fan speed option ( Low. Medium /High ) Auto Swing with all amendments (Make: Mitsubishi Electric- AGZISVF/ Mitsubishi Heavy-SRK20CXS-W6/ O General- ASGAISIIMWA-B (R32)/ Daikin - FTL50UV16V3) (As per choice of EIC) [NS]
SITC including vaccumiazation and Nitrogen of testing of following nominal size of soft/hard drawn copper refrigerent piping Split AC system, complete with fittings and including accessories, insulated with XLPE class -O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specification etc. as required. 1/4" (6.4 mm) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) incl. 19 mm thick insulation. [NS]
5/ 8" (15.88 mm.) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) mm incl. 19 mm thick insulation. [NS]
S & F 1.1 KV grade, PVC insulated & unsheathed 3 Core 2.5 Sqmm Copper flexible Cable (KEI/Finolex/RR Kable) for Indoor to outdoor connection as per direction of EIC. [NS]
Supply and laying PVC Drain Pipe 25mm dia. [Make:- Suprime/Oriplast]
Supplying fabrication & fixing of M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40mm) for making Base Frame/platform for installation of outdoor unit of above mentioned AC machines incl. drilling 2 nos holes in each channel, cutting holes into the wall & grouting the same with cement concrete(1:1 1/2:3) etc.fabricated with . horizontal angle of 25 mm x 25 mm x 6 mm and supporting angle of 50mm x50mm x 6mm in each platform in the outer edge for transmitting the load cenrally through 2 nos (50 mm x50mm x6 mm) angle inserted into the existing wall incl. fiber sheet shade as per Direction of E.l.C. The entire structure must be safe to carry out maintenance of ODU, as per Direction of E.l.C. [NS]
Making one set of scaffolding only for replacing glass panels, painting, uprooting plant and another repairing works of building and S&P works for external works only with 10 cm. dia bamboo as main posts at the rate of 1 metre centre to centre and 7.5 cm. dia bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-incharge. (This item should be executed only after prior approval of the Engineer-incharge). Firstly, one number to be paid and then labour rate for shifting up to further nineteenth (19) times @ 10% each time to be considered. If necessary further after twenty times of total use, another one number new and labour rate for shifting to be considered accordingly. (a) 3.9 meter height
(b) Extra for additional 3.6 height or part there of
Note:- Rate should be quoted inclusive of all taxes and duties including GST.
ANIKET COOLING AND REFRIGERATION CO (BID ID -6809767)
DAS REFRIGERATION CO. (BID ID -6809789)
BARSHA ENTERPRISE (BID ID -6809812)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .