| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAdmitted-Finance | ₹28.6 L | L1 | Admitted-Finance |
| 2 | L2₹30.9 L+₹2.3 L (7.95%)Admitted-Finance | ₹30.9 L+₹2.3 L (7.95%) | L2 | Admitted-Finance |
| 3 | L3₹33.8 L+₹5.2 L (18.2%)Admitted-Finance 2ND FLOOR COMMERCE CENTRE KULUR KAVOOR ROAD KULUR MANGALORE D K 575 013 | DAKSHINA KANNADA | KARNATAKA | 575013 | ₹33.8 L+₹5.2 L (18.2%) | L3 | Admitted-Finance |
| 4 | L4₹40.0 L+₹11.4 L (39.7%)Admitted-Finance | ₹40.0 L+₹11.4 L (39.7%) | L4 | Admitted-Finance |
| 5 | Rejected-Technical D NO 1 71 48 NANDAGOKULA MSEZ COLONY ROAD NO 20 KODIKERE KULAI DAKSHINA KANNADA KARNATAKA 575019 | DAKSHINA KANNADA | KARNATAKA | 575019 | - | - | Rejected-Technical As per tender |
| Sl No | Description | Qty | Unit | reflection L1 | M/s Anugraha power services L3 | M/s. Precision Electrical Works L4 | GK Electricals L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Circuit wiring - Wiring for circuit/ sub-main wiring along with earth wire with the following 2 x 1.5 sq. mm + 1 x 1.5 sq.mm earth wire sizes of FRLS PVC insulated copper conductors single core cable in surface/ recessed medium class PVC conduit as required. | 1,500 | Mtrs | 121 ₹1,81,500 Lowest | 140 ₹2,10,000 | 175 ₹2,62,500 | 130 ₹1,95,000 |
| 2.00 | Circuit wiring -Wiring for circuit/ sub main wiring along with earth wire with the following 2 x 2.5 sq. mm + 1 x 2.5 sq.mm earth wire sizes of FRLS PVC insulated copper conductors single core cable in surface/ recessed medium class PVC conduit as required. | 1,500 | Mtrs | 167.4 ₹2,51,100 | 190 ₹2,85,000 | 220 ₹3,30,000 | 165 ₹2,47,500 Lowest |
| 3.00 | Circuit wiring -Wiring for circuit/ sub main wiring along with earth wire with the following 2 x 4 sq. mm + 1 x 4 sq. mm earth wire sizes of FRLS PVC insulated copper conductors single core cable in surface/ recessed medium class PVC conduit as required. | 600 | Mtrs | 201.5 ₹1,20,900 Lowest | 240 ₹1,44,000 | 280 ₹1,68,000 | 240 ₹1,44,000 |
| 4.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch modular plate suitable GI box and earthing the point with 1.5sq mm FRLSPVC insulated copper conductor single core cable etc., as required (NOTE: the total distance from the switch box to the point will not exceed 5mtr, incase if length increase above 5 meters the wiring shall be measured under item 1) | 351 | Nos. | 670 ₹2,35,170 Lowest | 800 ₹2,80,800 | 1,000 ₹3,51,000 | 800 ₹2,80,800 |
| 5.00 | Group controlled light point with 1.5 sq. mm wire - Wiring for Group controlled light point (from one point to another point) with 3x1.5 sq.mm PVC insulated (FRLS) copper conductors cable in surface / recessed mounted rigid medium class 20mm PVC conduit with all accessories as required (NOTE: this item does not include the cost of MCB or 16Amp/6Amps one way switches the total distance from one point to another point will not exceed 5 meters. Incase if the total length increase, the additional length shall be measured under items 1 the distance from DB to 1st point will be measured under point circuit wiring. | 320 | Nos. | 803.43 ₹2,57,097.6 Lowest | 930 ₹2,97,600 | 1,200 ₹3,84,000 | 925 ₹2,96,000 |
| 6.00 | Supply of 2C x 4 sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date. | 700 | Mtrs | 109 ₹76,300 Lowest | 140 ₹98,000 | 186 ₹1,30,200 | 125 ₹87,500 |
| 7.00 | Supply of 4C x 4 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming 186 to IS 7098 (Part 1) amended upto date. | 1,500 | Mtrs | 109 ₹1,63,500 Lowest | 230 ₹3,45,000 | 335 ₹5,02,500 | 140 ₹2,10,000 |
| 8.00 | Supply of 4C x 16 Sq.mm size 1.1KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. | 100 | Mtrs | 144 ₹14,400 Lowest | 165 ₹16,500 | 175 ₹17,500 | 160 ₹16,000 |
| 9.00 | Supplying and making end termination with brass compression gland and aluminium lugs for following 4C x 16 Sq.mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. | 4 | Nos. | 500 ₹2,000 | 450 ₹1,800 Lowest | 600 ₹2,400 | 500 ₹2,000 |
| 10.00 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following upto 35 sq.mm (clamped with 1mm thick saddle) size on wall or surface as required. | 2,300 | Mtrs | 70 ₹1,61,000 | 40 ₹92,000 Lowest | 75 ₹1,72,500 | 45 ₹1,03,500 |
Tender Value
₹35.0 L
EMD Value
₹82,610
Closing Date
7 May 2026, 4:00 pmClosed
Executive Engineer Ele.2
Admin Building 2nd floor, NMPA Panambur, Mangaluru
Electrification for Renovated Cruise Lounge at Wharf
2026_NMPT_905730_1
1/Renovated CrsLounge/EE(E)II/2026 dtd.17.04.2026
Open Tender
Electrical Works
Works
NMPA, Panambur Mangaluru
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
FA and CAO NMPA Panambur
₹82,610
Yes
3 Jun 2026
17 Apr 2026
8 May 2026
17 Apr 2026
7 May 2026
18 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Circuit wiring - Wiring for circuit/ sub-main wiring along with earth wire with the following 2 x 1.5 sq. mm + 1 x 1.5 sq.mm earth wire sizes of FRLS PVC insulated copper conductors single core cable in surface/ recessed medium class PVC conduit as required. | - | Mtrs | - | - |
| 2 | Circuit wiring -Wiring for circuit/ sub main wiring along with earth wire with the following 2 x 2.5 sq. mm + 1 x 2.5 sq.mm earth wire sizes of FRLS PVC insulated copper conductors single core cable in surface/ recessed medium class PVC conduit as required. | - | Mtrs | - | - |
| 3 | Circuit wiring -Wiring for circuit/ sub main wiring along with earth wire with the following 2 x 4 sq. mm + 1 x 4 sq. mm earth wire sizes of FRLS PVC insulated copper conductors single core cable in surface/ recessed medium class PVC conduit as required. | - | Mtrs | - | - |
| 4 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch modular plate suitable GI box and earthing the point with 1.5sq mm FRLSPVC insulated copper conductor single core cable etc., as required (NOTE: the total distance from the switch box to the point will not exceed 5mtr, incase if length increase above 5 meters the wiring shall be measured under item 1) | - | Nos. | - | - |
| 5 | Group controlled light point with 1.5 sq. mm wire - Wiring for Group controlled light point (from one point to another point) with 3x1.5 sq.mm PVC insulated (FRLS) copper conductors cable in surface / recessed mounted rigid medium class 20mm PVC conduit with all accessories as required (NOTE: this item does not include the cost of MCB or 16Amp/6Amps one way switches the total distance from one point to another point will not exceed 5 meters. Incase if the total length increase, the additional length shall be measured under items 1 the distance from DB to 1st point will be measured under point circuit wiring. | - | Nos. | - | - |
| 6 | Supply of 2C x 4 sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date. | - | Mtrs | - | - |
| 7 | Supply of 4C x 4 Sq.mm size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming 186 to IS 7098 (Part 1) amended upto date. | - | Mtrs | - | - |
| 8 | Supply of 4C x 16 Sq.mm size 1.1KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. | - | Mtrs | - | - |
| 9 | Supplying and making end termination with brass compression gland and aluminium lugs for following 4C x 16 Sq.mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. | - | Nos. | - | - |
| 10 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following upto 35 sq.mm (clamped with 1mm thick saddle) size on wall or surface as required. | - | Mtrs | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
Tender.pdf
Tender Documents • 1.93 MB
BOQ_952020.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .