| Sl No | Description | Qty | Unit | Renjith M L4 | Water World L8 | NATHIPATHI ENGINEERS L3 | ARUNDAS Y R L2 | AJIL GEORGE L6 | THOMAS VARGHESE K L1 | Simon TJ L7 | TKM Infra Projects L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00working charges | |||||||||||
| 1.00 | OD14753/2026-2027:Design, testing, supply, erection, trial run and commissioning of vertical turbine pump sets with 16800 LPM against a total head of 23M and having 960 to 3880 rpm sync. Speed, Bronze LTB2 Impeller ,SS 316 shaft, cast iron casing, bronze LTB2 neck ring, SS 410 sleeve, squirrel cage EF2 motor with a complete integrated soft starter panel capable of operating the motor having a protection level of IP 40 or more with integrated bypass contactor in the panel and motor protection relay having parameters as per IE rules, with a power control MCCB and line power contactor, and the starting current shall be 1.5 times the normal full load current of motor with Ammeter, voltmeter and phase indicators, space heaters, floor monitory type and having an insulation level of 100 V ( the standard of starter is to be I.E.C 60947 - 4-2) control switches, capacitors, pressure guage etc satisfy the requirements and including the cost of internal wiring with suitable copper cable, valve ( PN 1.6), specials etc and fixing the flow meter to pump sets (motors, capacity, type etc should be specified) pipes and specials required for the interconnection works with the existing pumping main suction and delivery part of pumps including construction of suitable foundation and Anchor blocks of required size and provide the electrical and mechanical installation as pe the KSEB and KSEI specification and standards ( All items required for the commissioning should be supplied and erected/fixed and initial and final approval obtained from KSEI and got energized from KSEB). The pump and motor, supplied are to be from Kerala Water Authority short listed, manufactures and should be in accordance with relevant IS specification the actual head to be arrived by the contractor) LT motor required.
(1)Pump Supply, erection , testing and commissioning of KWA prequalified reputed make VT pump set with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete cost of cement sand and metal etc complete. Discharge -280 lps ,Total head-23 mts, that should be designed by the contractor as per the specific norms. Suction head-10 mts.(avg)
(2) Motor-Supply ,erection , testing and commissioning of KWA pre qualification reputed make TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300 V ( select the suitable). The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc complete as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors.
(3) Starter Supply, erection, testing and commissioning of suitable rating (fully Automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starters to be used) starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc complete.
(4)Panel board (suitable for operating two pump sets but one pump set at a time) Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going ( the two MCCBs are interlocking with each) providing suitable size Aluminum bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps. 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc. complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation.
(5) Cabling work Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. Considering energy conservation.
(6)Earthing Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc as per IE standards.
(7) Capacitor -
Supply, erection, testing and commissioning of heavy duty APF capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834.
(8) Valves-Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fixing of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice& valve should be in suction as well as delivery sides for easy repair works. (9) Suction and delivery pipe connections Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10m Suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. If the dia of suction pipe is above 80mm CI /DI pipes & specials shall be provided.
(10) Supply of suitable size cable of required quantity is included in this scope of work. No additional cost will be given for extra length.
(11) Fabrication work on MS pipe for connecting with the existing pumping main is included in this scope of work .No additional cost will be given for extra length. Warranty shall be limited to Five years (ie, the extended warranty of two years beyond the original warranty period of three year) | 1 | no | 32,25,013 ₹32,25,013 | 33,98,000 ₹33,98,000 | 28,10,000 ₹28,10,000 | 28,15,000 ₹28,15,000 | 31,82,560 ₹31,82,560 | 26,90,000 ₹26,90,000 Lowest | 33,13,855.28 ₹33,13,855.28 | 32,00,000 ₹32,00,000 |
| 1.00 | OD42921/2026-2027:Annual maintenance contract of newly commissioned 120 HP VT Pump set for a period of five years ( ie, the extended warranty of two years beyond the original warranty period of three year) from the date of commissioning. Annual maintenance contract also includes the supply, conveying and fixing the consumables like Gland bush,Gland cup, Spider bush in the pump and taper bearing roller bearing and other bearings in the motor and also the supply,conveying and fixing of pump shaft when ever required (Replacement of any parts is the responsibility of contractor) within five years from the date of commissioning for the smooth functioning of pump for 5 Yearwarranty. Supply bearing, Gland cup, gland bush, Gland packing ,spider bush (1 set) lubrication Oil (10 Ltrs) shall be effected at the time of commissioning | 1 | no | 25,000 ₹25,000 | 2,80,000 ₹2,80,000 | 35,000 ₹35,000 | 10,000 ₹10,000 Lowest | 82,000 ₹82,000 | 75,000 ₹75,000 | 57,735.35 ₹57,735.35 | 58,515 ₹58,515 |
Tender Value
₹38.0 L
EMD Value
₹50,000
Closing Date
8 Oct 2026, 3:00 pmClosed
Executive Engineer
O/o Executive Engineer PH Division(South) Thiruvanathapuram
DepositUrban agglomerationUA068Phase5 202526 CWSStoKovalam touristarea Vizhinjam corp area Kalliyoorand Venganoorgrama panchayath SupplyErection andCommissioning of120HP VT Pumpset at Rawwater pumphouse of 21 90MLDWTP VellayaniPipelineWork
2026_KWA_874825_1
TR/9272/2026_26_1_1/1
Open Tender
Civil Works - Water Works
Item Rate
150 days
Thiruvanathapuram
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,760
₹50,000
Yes
9 Oct 2026
30 Sept 2026
9 Oct 2026
30 Sept 2026
8 Oct 2026
30 Sept 2026
30 Sept 2026 - 8 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1working charges | |||||
| 1.001 | OD14753/2026-2027:Design, testing, supply, erection, trial run and commissioning of vertical turbine pump sets with 16800 LPM against a total head of 23M and having 960 to 3880 rpm sync. Speed, Bronze LTB2 Impeller ,SS 316 shaft, cast iron casing, bronze LTB2 neck ring, SS 410 sleeve, squirrel cage EF2 motor with a complete integrated soft starter panel capable of operating the motor having a protection level of IP 40 or more with integrated bypass contactor in the panel and motor protection relay having parameters as per IE rules, with a power control MCCB and line power contactor, and the starting current shall be 1.5 times the normal full load current of motor with Ammeter, voltmeter and phase indicators, space heaters, floor monitory type and having an insulation level of 100 V ( the standard of starter is to be I.E.C 60947 - 4-2) control switches, capacitors, pressure guage etc satisfy the requirements and including the cost of internal wiring with suitable copper cable, valve ( PN 1.6), specials etc and fixing the flow meter to pump sets (motors, capacity, type etc should be specified) pipes and specials required for the interconnection works with the existing pumping main suction and delivery part of pumps including construction of suitable foundation and Anchor blocks of required size and provide the electrical and mechanical installation as pe the KSEB and KSEI specification and standards ( All items required for the commissioning should be supplied and erected/fixed and initial and final approval obtained from KSEI and got energized from KSEB). The pump and motor, supplied are to be from Kerala Water Authority short listed, manufactures and should be in accordance with relevant IS specification the actual head to be arrived by the contractor) LT motor required.
(1)Pump Supply, erection , testing and commissioning of KWA prequalified reputed make VT pump set with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the base plate etc. complete cost of cement sand and metal etc complete. Discharge -280 lps ,Total head-23 mts, that should be designed by the contractor as per the specific norms. Suction head-10 mts.(avg)
(2) Motor-Supply ,erection , testing and commissioning of KWA pre qualification reputed make TEFC squirrel cage induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300 V ( select the suitable). The motor shall confirm to EEF1/IS 325 including providing suitable concrete foundation including cost of cement sand and metal etc complete as per present IE rules. Flexible coupling shall be used for coupling of pumps and motors.
(3) Starter Supply, erection, testing and commissioning of suitable rating (fully Automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starters to be used) starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc complete.
(4)Panel board (suitable for operating two pump sets but one pump set at a time) Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going ( the two MCCBs are interlocking with each) providing suitable size Aluminum bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps. 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc. complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation.
(5) Cabling work Supply, laying, testing and commissioning of suitable size XLPE cables for the above pump set from panel board to starter and from starter to motor. Considering energy conservation.
(6)Earthing Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc as per IE standards.
(7) Capacitor -
Supply, erection, testing and commissioning of heavy duty APF capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834.
(8) Valves-Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Non return valve with suitable pressure rating. Fixing of valves shall include proper RCC support especially for Non return valves. In case of positive suction pump set sluice& valve should be in suction as well as delivery sides for easy repair works. (9) Suction and delivery pipe connections Supply and fitting of suitable size best quality GI/MS pipe of thickness not less than 8mm for a total length of 10m Suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. If the dia of suction pipe is above 80mm CI /DI pipes & specials shall be provided.
(10) Supply of suitable size cable of required quantity is included in this scope of work. No additional cost will be given for extra length.
(11) Fabrication work on MS pipe for connecting with the existing pumping main is included in this scope of work .No additional cost will be given for extra length. Warranty shall be limited to Five years (ie, the extended warranty of two years beyond the original warranty period of three year) | 1 | no | - | - |
| 1.002 | OD42921/2026-2027:Annual maintenance contract of newly commissioned 120 HP VT Pump set for a period of five years ( ie, the extended warranty of two years beyond the original warranty period of three year) from the date of commissioning. Annual maintenance contract also includes the supply, conveying and fixing the consumables like Gland bush,Gland cup, Spider bush in the pump and taper bearing roller bearing and other bearings in the motor and also the supply,conveying and fixing of pump shaft when ever required (Replacement of any parts is the responsibility of contractor) within five years from the date of commissioning for the smooth functioning of pump for 5 Yearwarranty. Supply bearing, Gland cup, gland bush, Gland packing ,spider bush (1 set) lubrication Oil (10 Ltrs) shall be effected at the time of commissioning | 1 | no | - | - |
stage.html
html • 0.03 MB
finance_1485047.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
KWAGeneralConditionsforeTenderingV5.pdf
PDF • 0.69 MB
Tendernotice_1.pdf
PDF • 0.14 MB
NIT.pdf
Tender Documents • 1.01 MB
BOQ_1485047.xls
BOQ • 0.30 MB
tendercorrigendum.pdf
PDF • 0.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .