| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-Finance 133 GARFA MAIN ROAD KASBA KOLKATA 700078 | KOLKATA | KOLKATA | WEST BENGAL | 700078 | L1 | Accepted-Finance Being L1 Bidder | |
| 2 | L2₹5.2 L+₹16,364 (3.28%)Rejected-Finance 4 28 VIVEK NAGAR KOLKATA 700075 | KOLKATA | KOLKATA | WEST BENGAL | 700075 | L2 | Rejected-Finance Being L2 Bidder | |
| 3 | L3₹5.6 L+₹60,156 (12.1%)Rejected-Finance HALISAHAR NATUNPARA NORTH 24 PARGANAS | HALISAHAR | NORTH 24 PARGANAS | WEST BENGAL | 743135 | L3 | Rejected-Finance Being L3 Bidder |
Tender Value
Refer Docs
EMD Value
₹10,665
Closing Date
2 Oct 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE,NORTH 24 PARGANAS ELECTRICAL DIVISION,PWDte.
GOVERNMENT OF WEST BENGAL OFFICE OF THE EXECUTIVE ENGINEER NORTH 24 PARGANAS ELECTRICAL DIVISION, TOP FLOOR, MECHANICAL COMPLEX,BAGUIATI, KOLKATA 700 059
Urgent Electrical Renovation work of Rattirer sathi Scheme in Basirhat District Hospital, Basirhat Health district, North 24 Parganas.
2024_WBPWD_754045_1
WBPWD/EE/N24/EL/e NIQ-177/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
10 days
Basirhat District Hospital
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,665
4 Oct 2024
19 Sept 2024
3 Oct 2024
19 Sept 2024
2 Oct 2024
19 Sept 2024
Amount
Supply and delivery of High-wall Split type Air-conditioner machine having the following specification :- Cooling Capacity : 7.00 kW (Minimum) Minimum ISEER : 3.8, BEE levelling- 3 Star (min) [1st July 2022 to 31st December 2024] IS Compliance : IS-1391 (Part-I & Part-II) with all amendments Refrigrant : R410A/ R32 Compressor : Rotary/Scroll with fixed speed Evaporator & Condenser Coil : Copper Operating outdoor temperature : 50ºC and above Power Supply : 230V, 50Hz (±tolerance as per applicable standard) The PCB board of indoor unit should be covered by metallic enclosure. The scope of work is also includes supply of following (i) Necessary refrigerant copper line with nitrile rubber insulation and wrapping tape- 3 mtr. (ii) Necessary 3/4 core copper cable (FRLS type- make- Finolex/Polycab/RR Kabel) - 3 mtr and with 25A plug top with indicator (Legrand/Crabtree/Schneider/North West). (Make- Mitubishi Electric/ O-General/ Zamils). ( for room no 12 & 18- each room-2 no)
Installation, Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC machine after making hole in wall and mending good damages etc as per direction of EIC including Supply of required Refrigerant, S&F of necessary fixing arrangement for indoor and 40x40x5 mm MS angle iron frame for outdoor unit (or arrangement recommended by Manufacturer), duly painted, laying and making connection of refrigeration pipe, power cable, drain pipe etc as per direction of EIC.
S & F of additional following items for length exceeding 3 mtr. For complete installation and commissioning of above AC machine. (i) Supply & Fixing of extra refrigerant pipe (as requisite dia) with nitrile rubber insulation and wrapping tape (each mtr Refrigerent pipe will include cost of 1 meter liquid pipe line and 1 mtr gas pipe line of required dia and other accessories as required)
S & F of additional following items for length exceeding 3 mtr. for complete installation and commissioning of above AC machine. (i) 2.5 sqmm, 3/4 core copper cable (FRLS type- make: Polycab/Finolex/RR-Kabel)
Supply and Laying Soft Drawn PVC Drain Pipe 19 mm dia with proper supports & brackets as per direction of EIC. (Make- Suprime/Oriplast)
Supplying and fixing (2+12) way double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(Make: Legrand/ABB/Schneider)
Supplying and fixing 4way double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as per G.S..(Make: Legrand/ABBe/L&T)
Supplying and fixing 240/415 V 06-32A SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make: Legrand/ABB/L&T)
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection..(Make: Legrand/Schneider/L&T/ABB) 40A DP
S & F of 250V 1-phase AC Timer DB (equivalent to 10 way SPNDB in size) on wall with double door sheet steel enclosure, neutral bar, din rail, with lP43 protection comprises with 25A DPMCB (C-curve 10kA) and 1 no. 24 hr. Digital time switch (L&T, Crono 67DDTO) and 1 no. 22/25A 2 Pole power Contactor (L&T, MNX- 22 - 2P) complete with internal wiring with suitable size of PVC insulated copper wire with socketting and 2 nos. Connector including 1 no. Toggle switch for auto/manual operation and 1 no. LED indicator lamp and necessary earthing attachment as per direction of EIC. [Make : L&T/ABB/Legrand] [NS]
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm)single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] (i)(Avg run 08 mtr.) (Make: Finolex/Havells/Polycab/RR)
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish. On Board
Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Make: Anchor/Crabtree/L&T) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Make: Anchor/Crabtree/L&T) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Make: Anchor/Crabtree/L&T) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required i)2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC(S/p & Roof top light connection)
ii)2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC( For power plug)
iii)2 X 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC( For AC )
iv)2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC( SPNDB connection)
v)4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC( TPNDB connection)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 2.5 sqmm
Supply & Delivery of Twin LED Fitting (18 watt, 230 V AC, 50 Hz, 5700K CDL, THD< 10%, built in 2.5 KV SPD) with all accessories and 2 nos. LED Tube, as directed by EIC, Luminious efficacy > 105 & <120 Lumen/watt. The LED luminaves & accessories shall have BEE certification. [ NS ] (Make-Pholips/Crompton/Wipro) ( PC body)
Supply & Delivery of Single LED Fitting (18 watt, 230 V AC, 50 Hz, 5700K CDL, THD< 10%, built in 2.5 KV SPD) with all accessories and 1 nos. LED Tube, as directed by EIC, Luminious efficacy > 105 & <120 Lumen/watt. The LED luminaves & accessories shall have BEE certification. [ NS ] (Make-Pholips/Crompton/Wipro) ( PC body)
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener
Supplying & Fixing 240 V AC call bell (Make :- Anchor, Havelles, C&S, Goldmedal or approved by the EIC. ) on HW board incl. S&F HW board.
Supply & Fixing 9 watt LED lamp [Make-Philips /Crompton/Mazik]
i)S& F 09 “ sweep (1370 rpm) metal body AC Exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust also fixing louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long) (Make: EPC Heavy duty/crompton)( for toilet)
Supply & delivery of 1200mm 48" sweep 230V AC Ceiling fan complete with all accessories with safety wire & PS 2 type capacitor etc. as directed by EIC. (Make- Crompton Greaves- / Orient- /Usha or equivalent)
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/ perspex top cover by screw incl. making necy. connections etc.
Dismantling the existing wiring, PBDB, SPNDB, main switch, Tube fittings, Ceiling Fan, different size cables and wire etc. and mending goods the damages to original finish and supply to store, also replacing old accessories as per direction of site engineer.
DB Enterprise (BID ID -5669725)
Messrs HI- Q - ENTERPRISE (BID ID -5662846)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .