COMMANDER WORKS ENGINEER
Commander Works Engineers (Sub) Military Engineer Services PO Barrackpore, Dist 24 Pgns (N) Kolkata 700120 (W.B)
SPL REPAIRS AND UPGRADATION OF EXISTING SYSTEM OF ELECTRIC SUPPLY NEAR BLDG. NO. 5 AT SN BANERJEE ROAD UNDER GE BARRACKPORE
2023_MES_619807_3
CWE/BKP/26 OF 2023-2024
Open Tender
Civil Works
Item Rate
180 days
GE BARRACKPORE
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE BARRACKPORE
₹42,000
Yes
16 Dec 2023
20 Nov 2023
11 Dec 2023
20 Nov 2023
9 Dec 2023
20 Nov 2023
Amount
Supply,Install,Testing and Commissioning of step down transformer voltage rating HT11/0.433 KV,out door type of capacity 160 KVA LEVEL 2, 3 Phase,4 Wire,50 Hz, oil cooled, core type, floor mounted, Delta/star connected maximum losses as defined in vector group DYN 11,Double copper wound ONAN manual type off load tap changing facility on HT side to vary secondary voltage from minus 7.5 % to plus 7.5 % in steps of 2.5 % continuous rating of capacity 160 KVA incl cable box on both HT & LT side .The transformer shall be completed with all standard fittings and accessories, guages,first fill transformer oil as as per indication level etc and confirming to IS :1180 and fittings and accessories of transformers shall confirm to IS 3639-1996 as amended and duly mounted on rollers as per load bearing capacity of transformer and the transformer shall have the following fittings/accessories fitted complete all as specified and directed. (a) Rating plate and terminal marking plate of HT/LT sides (b) Two earthing terminals for body earthing and two additional for neutral brought out on a bushing (c) Lifting Lugs (d) Dehydrating silicagel breather (e) Oil level indicator with minium and maximum marking (f) Cooling Radiator (g) Thermometer pocket (h) Drain valve with plug or cover plate (i) Conservator tank (j) Oil filling hole with cover including funnel (k) Air release device (l) Thermometer 100 mm dia/stem type with metal guard having maximum temperature indication with resetting devices for transformer (m) Winding temperature indicator (n) Air release device for transformer Note : (a) Information plate /Technical data plate as laid down in para 15.2 and 15.3 as per IS. (b) The contractor shall be arranged factory inspection and drawings (General& circuit lay out drawings ) as approved by the Accepting Officer/Engineer -in-charge before procurement.
Vaccum Circuit Breaker of Outdoor type, totally enclosed metal clad switch gear complete with Horizontal Isolation, Horizontal draw out, motor wound spring charged mechanism with both electrical and mechanical release for closing and trip free operator mechanism type, protection IP-4X , dust proof vermine proof totally enclosed, metal clad, free standing type, safety interlocking system electrically & mechanically with all accessories as described here in below and including all accessories as specified in para 19.99 of MES SSR Part - I, 2009 as as per manufacturer's recommendation and complete all as specified and as directed. : (a) VCB 630A suitable for 11 KV 3 phase 50 Hz system with rupturing capacity 350MVA overload and earth fault protection, Ammeter , Voltmeter and all accessories as directed. - 01 No (b) Bus bar 600A 11 KV rated of high conductivity copper PVC insulated (suitable for carrying rated and SC current without overheating) - 01 set (c) Dual core dual ratio CT, epoxy cast resin type current transformer having ratio 200/100/5/5A, accuracy class 1.0 for metering core and 5P 10 for protection with VA burden 15VA - 01 No (d) Fixed type three phase copper wounded potential transformer epoxy cast rasin potential having ratio 11KV/110V having class 1.0 accuracy 100VA with HT/LT fuse to be fitted with incoming VCB. (e) IDMTL micro processor based numeric relay with combined. Note:- The contractor shall be arranged factory inspection and drawings (General& circuit lay out drawings ) as approved by the Accepting Officer/Engineer -in-charge before procurement.
Supply, laying & testing 11 KV (Earthed) grade cable XLPE insulated, screened, PVC bedded,galvanized steel strip or wire armoured, electric power cables (heavy duty ) with stranded aluminium conductor,11000 volts earth grade, of cross sectional area 3 core 95 sqmm including taking down old unserviceable item from existing location complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed. (Make : Raychem/M-Seal/Denson)
Supply and fix cable jointing kit for 11 KV grade cable for indore termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed. Make: Raychem/M-Seal/Denson
Material and labour for PCC (1:4:8), type D2 (using 40 mm graded stone aggregate) for making good cutting portion, mass concrete, filling of foundations etc including necessary use and waste of form work complete all as specified and directed
Material and labour for PCC (1:3:6), type C2 (using 40 mm graded stone aggregate) for making good cutting portion mass concrete, filling of foundations etc including necessary use and waste of form work complete all as specified and directed
Material and labour for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade ,cross-sectional area 150 sqmm, 3.5 core laid in trenches/pipes/ducts/walls with necessary cable lugs and glands, nuts, bolts and washers etc and testing including taking down old unserviceable item from existing location complete all as specified and directed.
Material and labour for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade ,cross-sectional area 70sqmm, 3.5 core laid in trenches/pipes/ducts/walls with necessary cable lugs and glands, nuts, bolts and washers etc and testing including taking down old unserviceable item from existing location complete all as specified and directed.
Material and labour for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade ,cross-sectional area 50sqmm, 3.5 core laid in trenches/pipes/ducts/walls with necessary cable lugs and glands, nuts, bolts and washers etc and testing including taking down old unserviceable item from existing location complete all as specified and directed.
Material and labour for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade ,cross-sectional area 25 sqmm, 4 core laid in trenches/pipes/ducts/walls with necessary cable lugs and glands, nuts, bolts and washers etc and testing including taking down old unserviceable item from existing location complete all as specified and directed.
Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size 32 X 6 mm from earth electrode to test point/equipment or up to 7.5 metres whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC (1:3:6) earth pit chamber type C1, RCC (1:2:4), cover type B1, including excavation/earth work in any strata and returning filling, removal of surplus soil and testing for required value including taking down old unserviceable item from existing location complete all as specified and directed.
Supply, installation, testing and commissinoning LT Feeder Panel of size 1500 x 1200 x 800, 3 phase ,4 wire ,415 volts, AC ,50Hz ,outdoor type, , floor mounted, free standing, dust and vermin proof, air ventilation made out of 3.15 mm thick CRCA sheet and suitable sized angle iron and flat duly powder coated and any manufacturer shall be followed CPRI norms and as approved by GE.Panel shall have front and rear opening,locking arrangement, cable alleys, bus bar chamber and switch gear compartment ,hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate,aluminium bus bar duly covered with heat shrink sleeves colour coaded duly fixed on DMC/SMC insulators, housed in a separate bus bar chamber,see through glass and control wiring with copper conductor cables of adequate size and length,incoming and outgoing MCCBs shall have extended bus bar links and civil work/PCC foundation as per site requirement and removing of old unserviceable item from existing location after disconnecting of existing cables complete all as specified and directed including comprising of following:- (a) MCCB 320 Amps,FP,36 KA,415 volts,50Hz- 01 Nos. (b) MCCB 120 Amps, FP 36 KA 415 volts, 50 Hz-02. (c) MCCB 63 Amps, FP 16 KA 415 volts, 50 Hz-03. (d) MCB A 40 TPN 10 KA 415 volts, 50 Hz-02. (e) Analogue time switch(Daily time switch) with suitable power contactor 63 Amps ML-2 type,3Phase,415 volts,Auto/Manual operating switches -01No. (f) Digital voltmeter,with VSS -01 set. (g) Digital, Ammeter,with CTs & ASS-01 set. (h) LED phase indication lamps RYB-01 set. (j) Aluminium bus bar TPN 600 Amps rating -01 set Note :- The contractor shall be arranged factory inspection and drawings (General& circuit lay out drawings ) as approved by the Accepting Officer/Engineer -in-charge before procurement.
M & L for brick sub class 'B' 250mm x 115mm x 75mm and laid in trenches as in protection of UG cable complete all as specified and directed.
Supply and filling in and spreading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft loose soil complete all as specified and directed.
Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed
Removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed
Material & labour for GI pipe 100 mm "light grade" laid in trenches/ floors/on pole/road for cable protection with all fittings complete all as specified and directed.
Boaring holes horizontally under road without damaging the surface of road (minimum 1.0 Mtr bellow the road surface) with the help of GI tubing of any dia not exc 80mm dia for passing of UG cable all as specified and as directed.
Surface dressing n.exc 15 cm deep soft/loose soil complete all as specified and directed.
M & L plain cement concrete (1:4:8), type D2 in foundations, filing & mass concrete all as specified and as directed.
M & L brick work with subclass `B' bricks, straight or curved on plan exc 6 m mean radius built in Cement Mortar (1 : 6) all as specified and as directed.
M & L broken brick bats deposited, spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface with broken stone or boulders
M & L for 100mm thick plain cement concrete (1:3:6), type C2, (using 40mm graded stone aggregate) maintaining panels as in sub-base complete all as specified and directed.
M & L for 100mm thick plain cement concrete (1:4:8), type D2, (using 40mm graded stone aggregate) maintaining panels as in sub-base complete all as specified and directed.
M&L for 100 mm thick cement concrete(1:2:4), type B-1, (using 20mm graded stone aggregate) with metallic hardener and finishing cement concrete surface even and smooth using extra cement complete all as specified and directed
M&L for rendering 15 mm thick plastering on fair faces of brickwork surfaces in cement mortar (1:6) making smooth and even surfaces without using extra cement complete all as specified and as directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance n.exc 50 m and making good surface all as specified and directed.
S & F Angle iron Posts and struts in fencing including embiding in concrete, cutting tops to shape as directed, drilling holes, notching for wire etc including MS flat iron fillets and MS Nut and bolts including all necessary drilling, bolting, welding or riveting, etc and similar work conforming to Fe 290 Gde E-165 all as specified and directed.
S & F 10 mm dia mild steel round bars as in line bars or hooking at one end fixed independently with chain link fencing or fixed the wire mess as strengthening bar including welding and binding etc all as directed and specified.
Dismantling fencing wire mesh, any type complete all as directed.
Supply only Chain link MS Galvanised Fencing any size or type complete all as specified.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire and all specified and directed.
M & L for preparation of new steel surfaces of any description not exc 10 cm width or girth and applying two coats of synthetic enamel paint of approved shade over one coat of red oxide primer not otherwise described including rubbing out and cleaning rust on new steel surfaces complete all as specified and as directed.
Supplying and laying reinforced precast concrete cable cover class HT, Type 1,flat, size 300mm x180 mm x 40 mm for protection under ground HT cable complete all as specified and directed
Disconnected all electrical connections and earth strip at existing transformer all connected accessories/cables and shifting of 11 KV/0.433 Volts 63 KVA to 200 KVA capacity transformer and transportation safely by hydra/ lifting vehicle including providing suitable carrying vehicle from sanik auditiorim to proposed power houses as per suitable directions of Engr-in-Charge and making all electrical connections properly with earth strip etc and to be re connected with the shifted transformer after servicing /overhauling of transformer and testing and including providing functional accessories such as nuts,bolts,washers, lugs, sleevs etc and megger testing and complete all as specified and directed
ChakrabortyTraders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .