Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-Finance | L1 | Accepted-Finance FIRST LOWEST BIDDER | |
| 2 | L2₹8.5 L+₹1.1 L (14.2%)Rejected-Finance H NO 206 RAJAPUR DUJANIA MOHALLA DASNA DEHAT VILLAGE TOWN INDERGARHI CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201002 INDIA | GHAZIABAD | UTTAR PRADESH | 201002 | L2 | Rejected-Finance SECOND LOWEST BIDDER | |
| 3 | L3₹8.6 L+₹1.1 L (15.4%)Rejected-Finance TEHSIL SARKAGHAT P O RAKHOH VILL GADHANI SARKAGHAT MANDI HP 175024 | MANDI | HIMACHAL PRADESH | 175024 | L3 | Rejected-Finance THIRD LOWEST BIDDER | |
| 4 | L4₹9.0 L+₹1.6 L (21.6%)Rejected-Finance | L4 | Rejected-Finance FOURTH LOWEST BIDDER | |
| 5 | L5₹10.9 L+₹3.5 L (46.6%)Rejected-Finance 51 212D 3E K V NAGAR NEAR ADARSH NAGAR KHERIA MOD AGRA UP 282001 | AGRA | UTTAR PRADESH | 282001 | L5 | Rejected-Finance FIFTH LOWEST BIDDER |
| Sl No | Description | Qty | Unit | VATANUCOOL ENGINEERS L3 | PANTECH INSTRUMENTS AND SERVICES L4 | SETHI BROTHERS L5 | Pawon Kumar Barik L1 | PARADISE INFRA POWER COMPANY L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Disconnecting, dismantling and taking out the existing Air conditioner Split type of any description, any make and in any position 1.5 TR/2 TR capacity, both indoor and outdoor unit single phase, strip opening , cleaning and servicing of the AC with using caustic soda/detergent solution, cleaning of suction air filter and coil of indoor unit and brazing the discharge and suction line, reassembling, fixing and testing of the AC complete all as specified and directed by Engr-in-Charge. | 100 | Each Job | 1,250 ₹1,25,000 | 1,000 ₹1,00,000 | 1,500 ₹1,50,000 | 501 ₹50,100 Lowest | 1,200 ₹1,20,000 |
| 1.01Note: (Applicable for Sch ‘A’ BOQ Item No.1.00). (i) Split type AC's shall be taken from department on "as and where installed" basis. (ii) Split type AC's are to be maintained for heating as well cooling , where this provision is in the machine. (iii) The spare parts measured & paid separately as supply only rates. Rate for fixing of spare parts (ie compressor, condensing coil, cooling coil & blower motor) under relevant items shall be included in item No.1). (iv) The contractor shall ensure and assess at the site any initial maintenance required, to make the all Split type AC's in proper working condition, at the time of taking over and he shall be laible to make all listed handed over units functional. (ii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item. | ||||||||
| 2.00 | Repair to existing compressor unit of suitable capacity/ model in the unit properly for 1.5/2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. | 1 | Each | 6,000 ₹6,000 | 2,000 ₹2,000 Lowest | 4,000 ₹4,000 | 2,500 ₹2,500 | 4,500 ₹4,500 |
| 3.00 | Supply only new Rotory type compressor sealed unit of suitable capacity/ model in the unit properly for 1.5/2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. | 2 | Each | 25,000 ₹50,000 | 10,000 ₹20,000 | 8,500 ₹17,000 Lowest | 10,099 ₹20,198 | 9,500 ₹19,000 |
| 4.00 | Supply only new condensing coil unit for Split type AC of any type/ any capacity complete, all as specified and directed by Engr-in-charge. | 1 | Each | 12,000 ₹12,000 | 1,500 ₹1,500 Lowest | 4,500 ₹4,500 | 7,777 ₹7,777 | 12,500 ₹12,500 |
| 5.00 | Supply only blower motor including fan blade, capacitor complete suitable for split type AC 1.5 ton/2.0 ton capacity 1/8 HP, 220 Volts, single phase complete,all as specified and directed by Engr-in-Charge. | 1 | Each | 3,500 ₹3,500 | 2,000 ₹2,000 | 2,500 ₹2,500 | 1,499 ₹1,499 Lowest | 6,500 ₹6,500 |
| 6.00 | M&L for charging refrigerant gas in the system of window/Split type AC of 1.5/2.0 ton capacity all as directed by the Engr-in-charge. (Note : The refrigerant gas measured and paid separately under relevant items as applicable as ‘supply only’). | 25 | Each Job | 500 ₹12,500 | 1,000 ₹25,000 | 800 ₹20,000 | 400 ₹10,000 Lowest | 3,200 ₹80,000 |
| 7.00 | M&L for replacement of unserviceable remote control assembly with PCB plate complete with connections suitable for Split AC 1.5TR/2TR single phase capacity complete all as specified and directed. | 2 | Each | 900 ₹1,800 Lowest | 2,200 ₹4,400 | 1,500 ₹3,000 | 1,000 ₹2,000 | 6,500 ₹13,000 |
| 8.00 | M&L for replacement of unserviceable Inverter PCB for Indoor complete with connections suitable for Split AC 1.5TR/2TR single phase capacity complete all as specified and directed . | 2 | Each | 2,200 ₹4,400 Lowest | 3,000 ₹6,000 | 2,500 ₹5,000 | 7,700 ₹15,400 | 5,500 ₹11,000 |
| 9.00 | M&L for replacement of unserviceable Inverter PCB for outdoor complete with connections suitable for Split AC 1.5TR/2TR single phase capacity complete all as specified and directed . | 2 | Each | 14,000 ₹28,000 | 14,000 ₹28,000 | 2,500 ₹5,000 Lowest | 7,700 ₹15,400 | 4,500 ₹9,000 |
Tender Value
₹12.2 L
EMD Value
₹24,460
Closing Date
1 Apr 2026, 6:00 pmClosed
GE(I)RND Dehradun
GE(I)RND Dehradun Pin-248001
PETTY REPAIRS REWIRING OF ALL INTERNAL ELECTIC SUPPLY OF BUILDING INCLUDING SUBMAIN, REPAIR OF ALL TYPES OF FANS, GEYSERS, ACS, COOLERS, GARDEN LIGHTS, BUILDING SECURITY LIGHTS ETC AND ALLIED MAINT WORKS IN TECHNICAL AND RESIDENTIAL AREA AT IRDE UN
2026_MES_755430_1
GE(I)RND/9537/E8/25-26
Open Tender
Civil Works
Item Rate
180 days
Dehradun
As per tender documents
7 documents required · 7 mandatory
₹500
GE(I) R AND D Dehradun
₹24,460
Yes
9 Apr 2026
6 Mar 2026
3 Apr 2026
6 Mar 2026
1 Apr 2026
20 Mar 2026
Disconnecting, dismantling and taking out the existing Air conditioner Split type of any description, any make and in any position 1.5 TR/2 TR capacity, both indoor and outdoor unit single phase, strip opening , cleaning and servicing of the AC with using caustic soda/detergent solution, cleaning of suction air filter and coil of indoor unit and brazing the discharge and suction line, reassembling, fixing and testing of the AC complete all as specified and directed by Engr-in-Charge.
Note: (Applicable for Sch ‘A’ BOQ Item No.1.00). (i) Split type AC's shall be taken from department on "as and where installed" basis. (ii) Split type AC's are to be maintained for heating as well cooling , where this provision is in the machine. (iii) The spare parts measured & paid separately as supply only rates. Rate for fixing of spare parts (ie compressor, condensing coil, cooling coil & blower motor) under relevant items shall be included in item No.1). (iv) The contractor shall ensure and assess at the site any initial maintenance required, to make the all Split type AC's in proper working condition, at the time of taking over and he shall be laible to make all listed handed over units functional. (ii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item.
Repair to existing compressor unit of suitable capacity/ model in the unit properly for 1.5/2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge.
Supply only new Rotory type compressor sealed unit of suitable capacity/ model in the unit properly for 1.5/2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge.
Supply only new condensing coil unit for Split type AC of any type/ any capacity complete, all as specified and directed by Engr-in-charge.
Supply only blower motor including fan blade, capacitor complete suitable for split type AC 1.5 ton/2.0 ton capacity 1/8 HP, 220 Volts, single phase complete,all as specified and directed by Engr-in-Charge.
M&L for charging refrigerant gas in the system of window/Split type AC of 1.5/2.0 ton capacity all as directed by the Engr-in-charge. (Note : The refrigerant gas measured and paid separately under relevant items as applicable as ‘supply only’).
M&L for replacement of unserviceable remote control assembly with PCB plate complete with connections suitable for Split AC 1.5TR/2TR single phase capacity complete all as specified and directed.
M&L for replacement of unserviceable Inverter PCB for Indoor complete with connections suitable for Split AC 1.5TR/2TR single phase capacity complete all as specified and directed .
M&L for replacement of unserviceable Inverter PCB for outdoor complete with connections suitable for Split AC 1.5TR/2TR single phase capacity complete all as specified and directed .
M&L for replacement of unserviceable 15/20 mm bore PVC flexible conduit complete, all as specified and directed by Engr-in-charge.
Supply and fixing in replacement refrigerant copper tubing 5/8" / 1/2" dia (as per existing one) with 22 gauge , fixed on wall / ceiling with saddle as per site requirement including making joints by brazing / flairing and checking for any leakage complete, all as specified and directed by Engr-in-charge.
Supply and fixing in replacement refrigerant copper tubing 3/8" / 1/4" dia (as per existing one) with 22 gauge , fixed on wall / ceiling with saddle as per site requirement including making joints by brazing / flairing and checking for any leakage complete, all as specified and directed by Engr-in-charge.
Supply and fixing in replacement foam type insulation sleeve for copper tubing 5/8" / 1/2"/ 3/8" / 1/4" dia (as per existing one) binding and securing the insulation firmly with copper tubing as per site requirement complete, all as specified and directed by Engr-in-charge.
M&L for replacement of unserviceable reverse cycle valve in window/Split type AC of 1.5 / 2 TR cap. and welding, brazing with copper tubing and testing complete all as specified and directed.
Supply only refrigerant gas R-22/R-32
Supply only refrigerant gas R-407/R-410
Supply and fix in replacemnt of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed.
Installation only split type AC including indoor/outdoor unit of capacity 1.5 Ton/2 Ton after carried out the repair under item No.1 at new location as directed including providing necessary chiseling/ cutting for fix the indoor/outdoor unit by means of suitable size of nut, bolt, angle iron structure, masonry work and making good the disturbed surface with PCC, plastering,white wash works,testing & checking complete,all as directed & specified by Engineer-in-Charge. (Note :- The spare parts measured & paid separately as supply only rates. Rate for fixing of spare parts (ie compressor, condensing coil, blower motor and nut bolt angle iron structure) under relevant items shall be included in this item) complete all as directed by Engineer-in-Charge.
Supply & Fixing in replacement of unserviceable Outdoor unit body complete with out compressor unit suitable for existing Split type AC of 1.5 TR capacity, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing in replacement of unserviceable indoor unit body complete suitable for existing Split type AC of 1.5 TR capacity complete all as specified and directed by Engr-in-Charge.
Disconnecting and removing the water and electric connections carefully from the existing Geyser of capacity 25/50 ltrs, any make and taking out the same in any position from the existing location. cleaning and de-scaling the inner tank using de-scaling solution mixed with water in suitable proportion till the complete deposits /scale is removed as approved by Engineer-in-Charge, brazing for stopping leakage of copper inner tank/gas welding for inner steel tank, re- assembling the complete Geyser after cleaning, Fixing and installation of Geyser in position and testing to the entire satisfaction of Engineer-in-Charge. Opening the Geyser for inspection, repairs and reassembling the same as per the original assembly after repairs/ replaceing the wourn out unserviceable parts with new parts as ordered including re-fixing same position of the Geyser and making electric connection, water inlet and outlet connection, testing and checking of all the functioning of water inlet outlet valves connected with geysers.all as specified and directed by Engr-in-Charge. Note :- Spare parts if any requires replacement shall be measured and paid for separately.
Supply only Heating element of the 1.5/2 KW rating as required at site including rubber washers of any make and type complete, all as specified and as directed by Engr-in-charge
Supply only assembly type round heating element of the 1.5/2 KW rating as required at site including rubber washers of any make and type complete, all as specified and as directed by Engr-in-charge
Supply only Thermostat with setting range 30°C to 80°C suitable for 230 volts AC, electric supply complete all as specified and directed.
Supply only Chromium plated copper connecting tube 450 mm long with two brass adopters suitable for 15 dia pipe and connecting up complete with washers complete, all as specified and as directed by Engr-in-charge.
Supply only PVC hot and cold connecting tube 600 mm long with two brass adopters suitable for 15 mm dia pipe and fixing in position ,superior quality as approved by Engineer-in-charge.
M&L in replacement of unserviceable Indicating lamp of size /shape as per existing suitable for 230 Volts AC supply. complete all as specified and directed.
Supply and fixing fastener of size 3" /4" fixing of geyser complete all as specified and directed.
Supply and fixing 'U' assembly 6 hole for 25 ltr geyser complete all as specified and directed.
Supply and fixing 'U' assembly 6 hole for 50 ltr geyser complete all as specified and directed.
Supply and fixing 'U' assembly 9 hole for 25 ltr geyser complete all as specified and directed.
Supply and fixing 'U' assembly 9 hole for 50 ltr geyser complete all as specified and directed.
Disconnecting , taking down & removing carefully the existing ceiling fan etc. of any description, any sweep and from any position / locations (i.e. Md Accn/ OTM Accn / Md Hostel/ Workshop/ Installations etc) for repairs / servicing / overhauling / painting / numbering etc., dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, hanging / fixing the repaired fans in position, connecting to existing electric sources and testing at site to the entire satisfaction of Engineer-in-Charge complete, all as specified and directed.
Disconnecting , taking down & removing carefully the existing exhaust fans etc. of any description, any sweep and from any position / locations (i.e. Md Accn/ OTM Accn / Md Hostel/ Workshop/ Installations) for repairs / servicing / overhauling / painting / numbering etc., dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, hanging / fixing the repaired fans in position, connecting to existing electric sources and testing at site to the entire satisfaction of Engineer-in-Charge complete, all as specified and directed.
Note for item No 33.00 and 34.00: (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include for transportation to & from of fans to workshop if required and approved by the Engineer-in-charge for necessary repairs. (iv) Cost of minor repair i.e. loose connection tightening, oiling greasing, tightening nut- bolts, insulating wire etc deemed to be inclusive in the item rate above. (v) Writing of fan No. and painting of fans shall be measured and paid for separately under appropriate item of Sch ‘A’
Supply only the following new parts suitable for the ceiling/ exhaust fans, wall bracket fans & pedestal fans, air circulating fans etc. of any description, any sweep :- Note :- Fixing & testing charges of these items are deemed to be included in the rates quoted by the tenderer for Sch ‘A’ item.
Supplying only ball bearing No 6200/6201/6202/6203
Supplying only capacitor of capacity 2.5 mfd
Supplying only capacitor of capacity 4 mfd
Supply only complete hanging assembly set comprising with rubber reel, MS clamps, nuts, bolts with lock pins suitable for any type of fans & down rods of length 300mm.
Supplying only PVC fan blade assembly with necessary MS nuts, bolts & washers suitable for exhaust fans of any descriptions of 250/300 mm sweep. (Note: Set of three blades shall be measured as one unit)
Supplying only aluminium cast metal fan blade assembly with necessary MS nuts, bolts & washers suitable for exhaust fans of any descriptions of 250/300 mm sweep. (Note: Set of three blades shall be measured as one unit)
Supply only MS tube medium grade 15mm dia duly finished with white colour two coats over a coat of red oxide primer cutting in desired length from 300 mm to 1500mm, cutting slot and drilling hole for down rod of fan complete all as specifieda and directed.
Taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enameled copper wire including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of Engineer-in-charge for the following Fans:-
Rewinding of motor of ceiling fans 1200 mm sweep.
Rewinding of motor of exhaust fan of 250/300 mm sweep.
Taking down existing worn out louvers of any description , in any position and supplying & fixing new louvers for exhaust fan of 250/300mm sweep all as specified & directed by Engineer-in-Charge. ( Note: The louvers shall be of shape, size and pattern as approved by the Engineer-in-Charge duly painted with two coat of synthetic enamel paint over a coat of red oxide primer)
Disconnecting and taking out old existing unserviceable ceiling fan modular regulator of any description and in any position/ location and supply and fixing ceiling fan modular regulator electronic, step type, 1M size modular type , suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply complete all as specified and directed.
M&L for painting of existing fans of any description of ceiling fan of 1200/1400mm sweep with applying one coat of synthetic enamel paint (White) by spray machine including preparation of existing decorated surfaces of fans complete, all as specified and directed by the Engineer-in-Charge.
M&L for painting of existing fans of any description of exhaust fan of 250/300/450mm sweep with applying one coat of synthetic enamel paint grey by spray machine including preparation of existing decorated surfaces of fans complete, all as specified and directed by the Engineer-in-Charge.
Supplying and fixing GI tubing 40mm, medium grade for hanging of ceiling fans including cutting holes in walls built in cement mortar and making good in cement sand mortar 1:4 and finish the surface to match with existing all as specified and directed by Engineer-in-Charge.
Taking down of carefully unserviceable Aluminium/copper point wiring (light, fan socket or power) complete with fitting such as switches, ceiling rose lamp holder, sockets, fan regulators, light fittings etc removing materials for store for keeping in safe custody or for taking credit (credit for above items should be taken as per conditions separately) and making good disturbed surfaces of walls, floors etc as specified and directed.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, concealed conduit wiring in walls and surface with GI saddles GI screws, rawal plugs in ceiling or roof if not possible including Tee, Junction boxes and provision of flush metal boxes, inner and outer plate suitable for modular switch, socket and fan regulator as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for one light/Fan point controlled by one Switch.
Description all as per Sr item No. 47.00 here in before but point wiring for one bell/buzzer point controlled by one push button on the same board with other switches or independent omplete all as specified and directed.
Description all as per Sr item No. 47.00 here in before but for point wiring for 5 pin switch socket outlet, 5/6 Amps on same board with other switches complete all as specified and directed.
Description all as per Sr item No. 47.00 here in before but for point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board.omplete all as specified and directed.
Description all as per Sr item No. 47.00 here in before but for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete.
Note for Sr item No. 47.00 to 51.00 : (i) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at RCC Columns/Beams/Ceilings shall be in surface conduit of suitable size fixed on surface with using PVC rawl plugs . (ii) Rate for modular metal flush boxes inner and outer plate with frames are deemed to be included in the quoted rate by contractor for above items. (iii) Fittings like Modular switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. (iv) The size of conduits shall be determined on permissible No. of runs of wires as specified in SSR Part-I (2009) clause 19.125 (B). However minimum size of conduit shall be 20mm dia (Medium grade).
S&F Modular switch piano single pole one way 6 amp complete.
S&F Modular switch piano single pole one way 16 amp complete.
S&F Modular bell push, 6 amp 240 volts complete.
S&F door bell, AC, 240 volts, single pole complete.
S&F Modular socket outlet 2/3 pin combined 2 module 6/16 amp complete.
S&F Modular socket outlet 2/3 pin combined 2 module 6 amp complete.
S&F ceiling rose 3 plates polycarbonate, isolated body complete.
S&F Angle holder, insulated polycabonate body with back plate suitable for batten fittings complete all as specified and directed.
S&F LED lamp/bulb 12/15 watt, Lumen out put 950, 6500 K , B22 complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete, all as specified and direced.
S&F in replacement of UNSV of Recess mounted 36 watts, 6500 k,4'x1' LED ceiling light fittings with slim line extruded aluminium / CRCA body, opal acrylic diffuser, electronic driver etc and all accessories pre wired including connecting to mains complete all as specified and directed.
S&F in replacement of UNSV LED mirror light fitting, 10 watts, 1000 lumens 6500K comprises of aluminium extruded channel, frosted diffuser, integrated electronic driver, IP 20 protection and all accessories pre- wired including connecting to mains complete all as directed.
S&F in replacement of UNSV bulkhead fitting with integrated LED bulk head fitting 10W 600 lumens, 6000 K comprises of pressure die cast housing, acrylic diffuser and frame IP 65 protection, IK-07 etc including connection complete all as directed.
S&F in replacement of UNSV Decorative, Wall mounting champagne gold finish fixture with plastic body along with 9 W LED lamp including connecting to mains complete all as directed.
Supplying, fixing & testing in replacement UNSV recess mounting in built , 36 Watts, 2'x2' LED ceiling light fitting with slim line extruded aluminium/ CRCA body, opal acrylic diffuser, electronic driver etc and all accessories pre wired including connecting to source complete all as specified & directed.
S&F in replacement of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole and neutral MCB 20 amp, 240Volts power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet with and including one number single pole 'C' series MCB 16/20 amp as required.
M&L in replacement UNSV of sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 20 mm dia with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 4.0 Sqmm as earth continuity conductor complete all as specified and directed.
Notes: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces.
M&L in replacement UNSV of sub main wiring using four single core PVC insulated, unsheathed stranded copper conductor cable of size 10 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 32 mm dia with standard accessories along-with two run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 10 Sqmm as earth continuity conductor wall/ ceiling/concealed surface etc complete all as specified and directed.
M&L in replacement UNSV of sub main wiring using four single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 32 mm dia with standard accessories along-with two run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor complete all as specified and directed.
Notes : (i) Four run of single core PVC cable with two run of earth conductor and one run of conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces.
S&F in replecement of UNSV vertical type load line distribution board ,double door, 8 way, AC 3 Phase 415 volt with TPN bus bar 250 Amps for each phase with 2 Neutral bar, 2 Earthbar and cable ties for cable management,fully insulted busbar & shrouded Neural bars ,improved Pan assembly for each insullation ,prefitted masking sheeet,reversible door for IP 43-"IK 09 with metal door with provision for DPX3 160 MCCB as incomer and SP/TP MCB's as out going complete all as specified and directed by Engr-in-Charge.
Description all as per sr item No. 71.00 here in before but 4 way complete all as specified and directed by Engr-in-Charge.
S&F in replacement of UNSV MCB distribution board SPN, 240 volts, 8 ways, powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 42- IK-09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required complete all as specified and directed by Engr-in-Charge.
Description all as per sr item No. 73.00 here in before but SPN, 240 volts, 12 ways.
Note (i) Fittings like MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. (ii) -Sheet steel enclosure to be fixed flush to wall by cutting niche & make good to the disturbed wall surface as per existing (iii) Rate for Incomer MCCB is deemed to be included under above item.
Supply and fix in replacement of UNSV MCB 3 pole, 50/ 63 Amps 415 volts, 50 Hz 'C' Curve having breaking capacity 10 KA , with thermal magnetic protection unit and testing complete all as specified and directed.
S&F in replacement of unserviceable MCB SPN 240 volts 'C' Curve suitable for fixing in MCB DB of capacity 6 to 32 amps complete all as specified and directed.
S&F in replacement of unserviceable MCB SP 240 volts 'C' Curve suitable for fixing in DB of capacity 6 to 32 Amps complete all as specified and directed.
S&F in replacement of UNSV modular switch socket combination universal type 6/16 Amps with box (2 hole complete with suitable connection with 2x2.5sqmm and 1x1.5sqmm single core cable length upto 01 mtr complete all as specified & directed.
S&F in replacement of UNSV modular switch socket combination universal type 6 Amps with box (2 hole complete with suitable connection with 2x1.5sqmm and 1x1.5sqmm single core cable length upto 01 mtr complete all as specified & directed.
S&F replacement of UNSV galvanized pressed steel terminal boxes concealed in wall of thickness 1.12 mm covered with phenolic laminated white sheet cover 3 mm thick in renewal of wooden/rusted boards of size 200 mm x 250 mm x 60 mm deep complete all as specified and directed.
S&F in replacement of UNSV switch piano single pole flush type 5 amps, 230 volts complete,all as specified and as directed by Engr-in-Charge.
S&F in replacement of UNSV socket out let 3 pin 5 Amps flush type complete all as specified and directed by Engr-in-Charge.
S&F in replacement of UNSV switch piano flush type single pole way15 Amps complete, all as specified and as directed by Engr-in-Charge.
S&F in replacement of UNSV socket outlet 2 in 1 3 pin 5/15 Amps flush type complete all as specified and as directed by Engr-in-Charge
stage.html
html • 0.05 MB
technical_846137.pdf
techsummary_846137.pdf
finance_846137.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
BOQ_846137.xls
BOQ • 1.33 MB
Tenderpages9537.pdf
Tender Documents • 0.63 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .