Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 1 SHAKTI NAGAR JAMMU JAMMU KASHMIR 180001 | JAMMU | JAMMU AND KASHMIR | 180001 | Accepted-Technical eligible |
| 2 | Accepted-Technical | Accepted-Technical eligible |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Others-the firm/proprietor has not performed this job when it was allotted to him hence his bid for the same work stands cancelled |
Tender Value
₹6.4 L
EMD Value
₹12,800
Closing Date
9 Mar 2026, 12:00 pmClosed
Executive Engineer Mech and Hosp Div Rajouri
Executive Engineer Mech and Hosp Div Rajouri
Balance works of Supply, Installation, Testing, and commissioning of fire safety measures and equipments along with Construction of under Ground water storage tank 16kl and SITC of 15KVA DG SET at CHC Darhal Rajouri Including CAMC of 1 Year.
2026_PWDJK_304052_1
MHDR/Tech/2025-26/84
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
15 days
Darhal
As per SBD
2 documents required · 2 mandatory
₹1,000
Executive Engineer Mech and Hosp Div Rajouri
₹12,800
Executive Engineer Mech and Hosp Div Rajouri
16 Mar 2026
20 Feb 2026
10 Mar 2026
20 Feb 2026
9 Mar 2026
21 Feb 2026
21 Feb 2026
Providing & fitting 30mtr. First Aid Hose Reel (1 No. On each block/floor) conforming to IS 884 along with thermoplastic hose as per IS: 12585 and gun metal globe valve & nozzle, drum and brackets for fixing the equipment on wall, connections from M.S pipe with stop gun metal valve & M.S pipe and socket.
SITC of silent type Diesel Generator set of 15 KVA prime rating, 415 volts at 1500 RPM, 0.8 lagging power factor suitable for 50 Hz ± 3%, three phase system, & for 0.85 load factor with CPCB sound proof acoustics enclosure fabricated out of 14/16 SWG CRCA Sheet, cooling, fuel, exhaust intake air, fuel, lube oil & governing systems, H class insulation, double layered lap stator winding, Synchronous alternator, with proper starting & shut down arrangement, Base frame, Engine Protection and Alarms for low lube pressure, high water Temp, high/low Dc Voltage, weak battery, over speed, fail to crank, fail to start, sensor failure, Battery charger, Acoustic Enclosure, 04 sets of earthing i.e. 2 for neutral & 2 for body, PVC/XLPE Al power Cables (1.1 KV grade armored cable 25 Sq mm of 3.5 core – 50 mtr) from Electrical Pole to DG Set and DG set to AVR. The DG set should comply to the latest CPCB norms and should be of reputed make ( Kirloskar, Mahindra, Eicher, Escorts, Cummins, equivalent standard make). Job includes the cost of material, labour charges and all taxes.
Shifting of already installed non functional 15KVA DG Set from CHC Darhal to workshop of Mechanical & Hospital Division Rajouri. the job includes dismantling from the foundations, loading & unloading using crane and carriage charges of truck.
CAMC for 01 year Post commissioning of System CAMC of complete fire fighting system installed in the Hospital
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.75 MB
BOQ_987595.xls
BOQ • 0.30 MB
ext0084.pdf
PDF • 0.63 MB
extension.pdf
PDF • 0.18 MB
ext84.pdf
PDF • 0.63 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .