Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.2 L+₹29,797.19 (5.03%)Rejected-Finance | L2 | Rejected-Finance As per committee resolution | |
| 3 | L3₹6.5 L+₹58,486.83 (9.87%)Rejected-Finance | L3 | Rejected-Finance As per committee resolution | |
| 4 | L4₹6.7 L+₹80,942.27 (13.7%)Rejected-Finance | L4 | Rejected-Finance As per committee resolution | |
| 5 | L5₹6.8 L+₹91,402.98 (15.4%)Rejected-Finance | L5 | Rejected-Finance As per committee resolution |
Tender Value
₹7.3 L
EMD Value
₹10,970
Closing Date
22 Oct 2021, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ASSISTANT ENGINEER
O/o The Assistant Engineer, LID-EW Section Kallikkadu Grama Panchayat 695572
Mylakkara Vallakadav Road Maintenance
2021_LSGD_443659_1
03/2021/AE/LID-EW/KKD
Open Tender
Civil Works - Roads
Item Rate
120 days
KALLIKKADU GRAMA PANCHAYATH
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,470
Yes
₹10,970
Yes
17 Dec 2021
8 Oct 2021
27 Oct 2021
8 Oct 2021
22 Oct 2021
8 Oct 2021
120 days
Amount
MAINTENANCE
5.2.1a : Tack Coat<br> Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
5.5.A.1a : Modified Penetration Macadam 50 mm thick using Bitumen S-65 <br> Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.
75.5.9.1.2Z : 20mm thick Open-Graded Premix Carpet using Bitumen S-65 and Antistripping Agent <br> Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. <br> Case - I By Manual Means <br> (II) Bitumen (S-65)
75.5.12.A.3.2Z : Seal Coat - Manual Means - Type C - Bitumen S-65 and Antistripping Agent <br> Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 <br> A. By Manual Means <br> Case - III : Type C <br> (II) Bitumen (S-65)
3.5.1 : Excavation in Cutting in Soil by manual means with lead upto 50 m Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
75.8.1.1.A : Providing Plain cement concrete for wearing coat CC 1:2:4 (1 cement: 2 fine aggregate: 4 course aggregate) laid to required slope as required including compaction, finishing and tamping etc .complete. Max. size of course aggregate not exceeding 25mm , mixed in concrete mixer etc complete as per specification (i) Nominal mix (1:2:4)
2.7.D : Dismantling Stone Masonry as per Technical Specification Clause 202. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.(D)Dry Rubble Masonry
75.7.1 : DRY RUBBLE MASONRY _ Random rubble masonry with hard stone, including Through/Bond stone in foundation and superstructure including packing to compactness to lines and levels, cost and conveyance of all materials labour charges etc. complete as per approved drawing and relevant technical specifications.
od1365638/2021_2022 : Dry rubble masonry using departmental rubble etc. complte.
75.8.1.1 : Providing plain/reinforced concrete(1 cement:2 fine aggregate: 4 course aggregate) for substructure as per drawings and technical specifications Clause 802, 803, 1202 & 1203 as required including compaction, finishing and tamping etc .complete. Max. size of course aggregate not exceeding 25mm , mixed in concrete mixer etc complete as per specification (i) Nominal mix (1:2:4)
K VINOD
WILSONRAJ M
RENJULAL S
R VIJAYAKUMAR
Bidder Name
R VIJAYAKUMAR
RENJULAL S
VIJAYAN D
K VINOD
WILSONRAJ M
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_632036.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .