| 1 | L1₹22.0 LAccepted-AOC | ₹22.0 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹23.9 LRejected-Finance 232 1 D SHIVLOK KANKARKHERA DISTT MEERUT UP PIN 250001 | MEERUT | MEERUT | UP | 250001 | ₹23.9 L | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹25.2 LRejected-Finance | ₹25.2 L | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹26.7 LRejected-Finance H NO 861 SECTOR 1 4 HOUSING BOARD COLONY NEAR POLY CLINIC HISAR HARYANA | HISAR | HARYANA | 125001 | ₹26.7 L | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹30.0 LRejected-Finance H NO 425 WARD NO 4 BAHADURGARH ROAD MOHALLA RAM NAGAR NEAR MAIN GATE JHAJJAR 124103 HARYANA | JHAJJAR | JHAJJAR | HARYANA | 124103 | ₹30.0 L | L5 | Rejected-Finance Not Lowest |
| Sl No | Description | Qty | Unit | M/S HINA ELECTRICALS L3 | Shikhar ji Enterprises L2 | Nikunj Bansal Govt Contractor L5 | M/S SRIDEVI ENTERPRISES L1 | Natwadia Electrical Company L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply , install, testing and commissioning of silent (acoustic enclouser type) Diesel Engine driven generating set of capacity 100 KVA, CPCB IV+ norms, alongwith necessary PCC foundation work as per manufacturer instructions, vibration and damper pads, RECD type-IV , 415 volts, 3 phase 4 wire with Auto Main Failure Panel directly coupled complete with self starting system including accessories, equipment control panel etc as per BS/IS-5514/10002, complete and including of the followings:-
(Make : Kirloskar/ Cummins/ Greaves/ Mahindra) (a) Alternator:- 100 KVA output at 0.8 PF AC 3 phase 4 wire 415 volts 50 C/S, brush less, self regulated, screen protected drip proof type with two end shield ball/Roller bearing with damper winding in each pole faces, class 'H' insulation with IP-23 protection and voltage regulation + 1.5% as per IS-4722 or BS 2613 -1970 all as specified and directed. Make Kirloskar/crompton/stamford.
(b) Diesel engine : Diesel engine multi cylinder 4 stroke, water cooled electric start suitable capacity to drive above alternator independently, coupled directly through flexible coupling, cold starting, speed of DG set from No load to full load complete with fuel tank of capacity as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and residential silencer mufflers etc for continuous operation and standard accessories, sump preheaters etc all as specified. (c) Control panel. The standard control panel consisting of control cubical fabricated sheet steel construction indoor type suitable for the followings- (i) Gen set controller microprocessor based multifunctional with LED display for engine water temperature, Lub oil pressure, Engine RPM, Engine shut down display, total Hours run and suitable for protection against high water pressure, low lub oil pressure, over speed and battery charger failure | 1 | Each | 14,90,000 ₹14.9 L | 13,65,000 ₹13.7 L | 18,00,000 ₹18 L | 12,50,000 ₹12.5 L | 18,50,000 ₹18.5 L |
| 1.01(ii) Digital multifunctional meter with LED display suitable to display all electrical parameters of individual phase such as Voltage, current, frequency, KVA, KW, power factor and having RS 485 communication port complete with appropriate CTs and control wiring. (iii) MCCB 4 pole 415 volt AC of suitable capacity not less than 250 Amps all as required complete with copper bus bar all as per standard engineering practice and as per manufacturer recomendations. (iv) HRC fuses for protection as per standard engineering practice and manufacturer recommendations for protection of meters etc. (d) Electric Starter Equipment :- The equipment will comprise the followings:- (i) Start Stop push button. (ii) Maint free Battery duly initial charged & Battery lead of adequate capacity (iii) Foundation as per manufacturer recommendation | ||||||||
| 2.00 | Supply and laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts g de of size 95 sqmm x 3.5 core laid in trenches, passing through pipes, fixed o walls complete including connecting properly by means of thimbles vetc, complete all as specified and as directed. | 270 | RM | 600 ₹1.6 L | 520 ₹1.4 L | 835 ₹2.3 L | 460 ₹1.2 L | 450 ₹1.2 L |
| 3.00 | Ditto, but sec. area 16 sqmm X 4 Core complete all as specified and as directed. | 130 | RM | 180 ₹23,400 | 150 ₹19,500 | 305 ₹39,650 | 178 ₹23,140 | 120 ₹15,600 |
| 4.00 | Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth for laying of electric cables or water pipe etc, not exc 10 sqmm on plan and not exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer-inCharge. | 89.1 | Cum | 150 ₹13,365 | 100 ₹8,910 | 10 ₹891 | 200 ₹17,820 | 200 ₹17,820 |
| 5.00 | Retuming filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed. | 59.07 | Cum | 100 ₹5,907 | 40 ₹2,362.80 | 10 ₹590.70 | 80 ₹4,725.60 | 50 ₹2,953.50 |
| 6.00 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the startin ointcomplete all as s ecified complete all as specified and as directed. | 30.03 | Cum | 60 ₹1,801.80 | 50 ₹1,501.50 | 10 ₹300.30 | 100 ₹3,003 | 100 ₹3,003 |
| 7.00 | Material and labour for river washed and screened, dry sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I and as directed.
Note Only Punned thickness of sand will be measured | 26.73 | Cum | 400 ₹10,692 | 500 ₹13,365 | 995 ₹26,596.35 | 1,200 ₹32,076 | 300 ₹8,019 |
| 8.00 | Supply, laying un-reinforced precast concrete cable cover class LV type 1 flat size 250mm x 150 mmx 40 mm complete all as specified and as directed. | 2,200 | Each | 15 ₹33,000 | 18 ₹39,600 | 22 ₹48,400 | 30 ₹66,000 | 12 ₹26,400 |
| 9.00 | M&L for G/ pipe ,light grade 80mm dia for road crossing of cable for cable protection laid in trenches or above ground surface, complete all as specified and directed. | 12 | RM | 400 ₹4,800 | 350 ₹4,200 | 768 ₹9,216 | 400 ₹4,800 | 500 ₹6,000 |
Updated dates
Tender Value
₹27.7 L
EMD Value
₹55,340
Closing Date
4 Dec 2025, 6:00 pmClosed
CWE Bareilly
HEADQUARTERS, COMMANDER WORKS ENGINEER, MILITARY ENGINEER SERVICES, STATION ROAD, BAREILLY CANTT, PIN 243001
CA NO.CWE BLY/GE (E) /87 OF 2025- 2026PROVN OF DG SET AND AIR CONDITIONING AT COMD COMPLEX OF 6 MTN DIV SIG REGT UNDER GE (EAST) BAREILLY
2025_MES_738556_1
8200/B/895/E8
Open Tender
Electrical and Maintenance Works
180 days
GE (East) Bareilly
As per NIT
7 documents required · 7 mandatory
₹500
GE (East) Bareilly
₹55,340
Yes
3 Feb 2026
6 Nov 2025
11 Dec 2025
6 Nov 2025
4 Dec 2025
20 Nov 2025
Amount
Supply , install, testing and commissioning of silent (acoustic enclouser type) Diesel Engine driven generating set of capacity 100 KVA, CPCB IV+ norms, alongwith necessary PCC foundation work as per manufacturer instructions, vibration and damper pads, RECD type-IV , 415 volts, 3 phase 4 wire with Auto Main Failure Panel directly coupled complete with self starting system including accessories, equipment control panel etc as per BS/IS-5514/10002, complete and including of the followings:- (Make : Kirloskar/ Cummins/ Greaves/ Mahindra) (a) Alternator:- 100 KVA output at 0.8 PF AC 3 phase 4 wire 415 volts 50 C/S, brush less, self regulated, screen protected drip proof type with two end shield ball/Roller bearing with damper winding in each pole faces, class 'H' insulation with IP-23 protection and voltage regulation + 1.5% as per IS-4722 or BS 2613 -1970 all as specified and directed. Make Kirloskar/crompton/stamford. (b) Diesel engine : Diesel engine multi cylinder 4 stroke, water cooled electric start suitable capacity to drive above alternator independently, coupled directly through flexible coupling, cold starting, speed of DG set from No load to full load complete with fuel tank of capacity as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and residential silencer mufflers etc for continuous operation and standard accessories, sump preheaters etc all as specified. (c) Control panel. The standard control panel consisting of control cubical fabricated sheet steel construction indoor type suitable for the followings- (i) Gen set controller microprocessor based multifunctional with LED display for engine water temperature, Lub oil pressure, Engine RPM, Engine shut down display, total Hours run and suitable for protection against high water pressure, low lub oil pressure, over speed and battery charger failure
(ii) Digital multifunctional meter with LED display suitable to display all electrical parameters of individual phase such as Voltage, current, frequency, KVA, KW, power factor and having RS 485 communication port complete with appropriate CTs and control wiring. (iii) MCCB 4 pole 415 volt AC of suitable capacity not less than 250 Amps all as required complete with copper bus bar all as per standard engineering practice and as per manufacturer recomendations. (iv) HRC fuses for protection as per standard engineering practice and manufacturer recommendations for protection of meters etc. (d) Electric Starter Equipment :- The equipment will comprise the followings:- (i) Start Stop push button. (ii) Maint free Battery duly initial charged & Battery lead of adequate capacity (iii) Foundation as per manufacturer recommendation
Supply and laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts g de of size 95 sqmm x 3.5 core laid in trenches, passing through pipes, fixed o walls complete including connecting properly by means of thimbles vetc, complete all as specified and as directed.
Ditto, but sec. area 16 sqmm X 4 Core complete all as specified and as directed.
Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth for laying of electric cables or water pipe etc, not exc 10 sqmm on plan and not exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer-inCharge.
Retuming filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the startin ointcomplete all as s ecified complete all as specified and as directed.
Material and labour for river washed and screened, dry sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I and as directed. Note Only Punned thickness of sand will be measured
Supply, laying un-reinforced precast concrete cable cover class LV type 1 flat size 250mm x 150 mmx 40 mm complete all as specified and as directed.
M&L for G/ pipe ,light grade 80mm dia for road crossing of cable for cable protection laid in trenches or above ground surface, complete all as specified and directed.
S&F Changeover switch On load type of capacity 160 Amps 4 Pole complete with sheet enclosure and handle complete all as specified and as directed.
Supply, installing, testing and commissioning Factory made outdoor LT feeder piller box, double door type of suitable size, padestal mounted, CPRI approved totally enclosed, dust and vermin proof, Front and rear openable type made of 3.15 mm thick CRCA sheet and having proper locking arrangement duly painted to both internal and External surfaces with super enaleled paint over a coat of red oxide and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising of three phase coppere busbarr of current carrying capacity 400 Amps mounted on angle iron legs of size 50 x 50 x 6 mm x 80 cm long embedded in PCC 1:3:6, including excavation / preparation of ground complete connecting UG cable with cable glands of suitable size Make :SMS Panels and Switch Gears/ Universal switch gears Control and equivalent (233 Fd Wksp)
M&L for boring the holes under roads pavements, hardstanding by treanch less techonology, using ultrasound technique and necessary machine including DI/CI/GI/HDPE/PP-R Pipe of 25 mm to 150 mm bore suitable for 0.4 mpa working pressure complete all as specified and directed.
M&L for dismantling hardstanding and taking out interlocking tiles from path way and keeping aside or safe custory for reuse including replacement of damaged tiles or PCC and road after laying of cable including necessary Sand, PCC work required as per site requirement, making disturbed surface good as original and as directed by Engr-in-charge
M&L for Earthing complete with galvanized iron earth plate electrode 600 x600x6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.6 meter below normal ground level connected to galvanised iron strip 25x4mm as earthing lead by means of bolts, nuts check nuts galvanized iron or steel all as shown •in Electrical plate No. 3 of SSR PT- I testing on completion with & incl. 15 mm bore light grade GI protection pipe 7.5 mtr long for earth lead, PCC (1:3:6) pit with pre cast RCC (1:2:4) type Bl cover slab with one handle made out of 8mm dia round bar, watering arrangement with funnel, wire mesh 20 mm bore light grade Gl pipe, common salt & charcoal alternative layers, necessary excavation earth work, including earthing test point all as specified or indicated including testing on completion and as directed. Notes:(i) The cost of Gl earth continuity conductor with GI pipe 14 mm light grade upto 7.5m is deemed to be included in rlo above item. (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement, the cost for the same is deemed to be included in above item.
Supply and install inverter type hi wall split units indoor and outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air qualityr with minimum 5 star rating and latest EER of capacity 2 TR, copper condenser and cooling unit, Refrigerant R-32, compressor invertor rotary type including copper refrigerant pipe duly insulated and control cable 3 core 4 sqmm , water drain pipe as per site requirement , including mounting stand and accessoried for mounting outdoor unit as per site requirement, necessary civil work for making hole for pipes and stand as per site requirement and making disturbed surface good as original complete all as specified and directed
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% with digital display showing input and output voltage of capacity 4 KVA, intellegent time delay system wall mounted with built in thermal overload complete all as specified and as directed.
M&L for concealed sub main wiring with 2 run of 4 Sqmm FR, PVC insulated, unsheathed and stranded copper conductor cable with and incl 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn drawn through & PVC conduit of size 20 mm and above incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. incl taking out old wiring and conduit
S&F AC functional box modular type with a two pin and earth plug and socket complete with one single pole MCB 20 Amp
S & F sheet metal enclosures TPN MCB DBS 4 Way, 415 Volts, 50Hz, AC, double door suitable for flush mounting and surface mounting, conforming to IP 43 - 1K 09 with acrylic door with 200 Amp copper bus bar for phase, complete with din rail, Neutral and Earthing bar, including connection, testing and making good the disturbed surfaces complete all as specified and as directed.
Supply and fixingt MCB TPN 40 to 100 amps rating 415V, 10KA 'C' curve miniature circuit breaker (MCB) complete with connection testing and commissioning complete all as specified and as directed.
Supply and fixing SP 5 to 32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of Single pole and neutral in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanized iron earth wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 3 of SSR Part-I and connecting to MCBDB’s earth test point all as specified or indicated including testing on completion .
Shikhar ji Enterprises (BID ID -3482697)
M/S HINA ELECTRICALS (BID ID -3480882)
Natwadia Electrical Company (BID ID -3483650)
Nikunj Bansal Govt Contractor (BID ID -3484171)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
BOQ_826975.xls
BOQ • 0.83 MB
TD87.pdf
Tender Documents • 2.67 MB
Download all tender documents and submit your bid