Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹52.4 LQualified ERDA ROAD GIDC MAKARPURA INDUSTRIAL AREA THANE BELAPUR ROAD VADODARA VADODARA GUJARAT 390010 | VADODARA | GUJARAT | 390010 | L1 | Qualified | |
| 2 | Disqualified B 6 PLOT NO D 24 CLASSIC INDUSTRIAL ESTATE MIDC AMBAD NASHIK NASHIK MAHARASHTRA 422010 | NASHIK | MAHARASHTRA | 422010 | - | Disqualified MSE |
Tender Value
Refer Docs
EMD Value
₹1.0 L
Closing Date
9 Feb 2024, 11:00 amClosed
Customized AMC/CMC for Pre-owned Products - Power Transformer Oil Sample analysis For Complete Physical And Chemical Test As per IS 1866; --; Annual Maintenance Contract (AMC); Annually; Yes
Customized AMC/CMC for Pre-owned Products - Power Transformer Oil Sample analysis For DGA; --; Annual Maintenance Contract (AMC); Six-Monthly; Yes
Customized AMC/CMC for Pre-owned Products - Power Transformer Oil Sample analysis For Furan; --; Annual Maintenance Contract (AMC); Annually; Yes
Customized AMC/CMC for Pre-owned Products - Power Transformer Oil Sample analysis For BDV And Moisture; --; Annual Maintenance Contract (AMC); Annually; Yes
Customized AMC/CMC for Pre-owned Products - Power Transformer Online Testing For Discharge Detection Using Acoustic Emission Technique; --; Annual Maintenance Contract (AMC); Annually; Yes
Customized AMC/CMC for Pre-owned Products - Power Transformer Offline testing For Step voltage DIRANA SFRA Cap And Tan Delta IR PI TTR WR; --; Annual Maintenance Contract (AMC); Annually; Yes
Customized AMC/CMC for Pre-owned Products - Power Transformer Offline testing For Capacitance And Ten Delta Tests On Bushing; --; Annual Maintenance Contract (AMC); Annually; Yes
Customized AMC/CMC for Pre-owned Products - 220 KV Switchyard Electrical Equipment Offline Testing For CT CVT EMPT; --; Annual Maintenance Contract (AMC); Annually; Yes
Customized AMC/CMC for Pre-owned Products - 220 KV Or 132 KV Lightining Arrester For Online Third Harmonic Resistive Current Meaurement; --; Annual Maintenance Contract (AMC); Annually; Yes
Customized AMC/CMC for Pre-owned Products - Station Earth Resistance Measurment by Fall Of Potential Method; --; Annual Maintenance Contract (AMC); Annually; Yes
Customized AMC/CMC for Pre-owned Products - Motor Current Signature Analysis Of 3 point 3 KV And 415 V Motors; --; Annual Maintenance Contract (AMC); Annually; Yes
Customized AMC/CMC for Pre-owned Products - Offline Elctrical Testing Of 1200 Kw 415 V DG Sets For RSO Step Voltage Surge Comparision winding Resistance AC Impedence IR And PI; --; Annual Maintenance Contract (AMC); Annually; Yes
Customized AMC/CMC for Pre-owned Products - Online Elctrical Testing Of 350 KW 250 VDC Motors For DC Motor current Signature Analysis; --; Annual Maintenance Contract (AMC); Annually; Yes
Customized AMC/CMC for Pre-owned Products - Ofline Elctrical Testing Of 350 KW 250 VDC Motors For DC Motor Circuit Analysis; --; Annual Maintenance Contract (AMC); Annually; Yes
Customized AMC/CMC for Pre-owned Products - Very Low Frequency Ten Delta And Partial Discharge Meaurement Of 3 Point 3 KV HT Cables; --; Annual Maintenance Contract (AMC); Annually; Yes
Customized AMC/CMC for Pre-owned Products - Dynamic Contacts Resistance Meaurement Of 245 KV SF6 Gas circuit Breaker; --; Annual Maintenance Contract (AMC); Annually; Yes
Customized AMC/CMC for Pre-owned Products - 245 KV SF6 Or Minimum Oil Circuit Breaker Open Close Timing Measurement Of All Three Phases; --; Annual Maintenance Contract (AMC); Annually; Yes
5859525
GEM/2024/B/4450128
Two Packet Bid
Customized AMC/CMC for Pre-owned Products - Power Transformer Oil Sample analysis For Complete Phys
12 days
Rajasthan; Chittorgarh
Total value wise evaluation
SERVICE
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Customized AMC/CMC for Pre-owned Products - Power Transformer Oil Sample analysis For Complete Physical And Chemical Test As per IS 1866; --; Annual Maintenance Contract (AMC); Annually; Yes | - | - | - |
| Customized AMC/CMC for Pre-owned Products - Power Transformer Oil Sample analysis For DGA; --; Annual Maintenance Contract (AMC); Six-Monthly; Yes | - | - | - |
| Customized AMC/CMC for Pre-owned Products - Power Transformer Oil Sample analysis For Furan; --; Annual Maintenance Contract (AMC); Annually; Yes | - | - | - |
| Customized AMC/CMC for Pre-owned Products - Power Transformer Oil Sample analysis For BDV And Moisture; --; Annual Maintenance Contract (AMC); Annually; Yes | - | - | - |
| Customized AMC/CMC for Pre-owned Products - Power Transformer Online Testing For Discharge Detection Using Acoustic Emission Technique; --; Annual Maintenance Contract (AMC); Annually; Yes | - | - | - |
| Customized AMC/CMC for Pre-owned Products - Power Transformer Offline testing For Step voltage DIRANA SFRA Cap And Tan Delta IR PI TTR WR; --; Annual Maintenance Contract (AMC); Annually; Yes | - | - | - |
| Customized AMC/CMC for Pre-owned Products - Power Transformer Offline testing For Capacitance And Ten Delta Tests On Bushing; --; Annual Maintenance Contract (AMC); Annually; Yes | - | - | - |
| Customized AMC/CMC for Pre-owned Products - 220 KV Switchyard Electrical Equipment Offline Testing For CT CVT EMPT; --; Annual Maintenance Contract (AMC); Annually; Yes | - | - | - |
| Customized AMC/CMC for Pre-owned Products - 220 KV Or 132 KV Lightining Arrester For Online Third Harmonic Resistive Current Meaurement; --; Annual Maintenance Contract (AMC); Annually; Yes | - | - | - |
| Customized AMC/CMC for Pre-owned Products - Station Earth Resistance Measurment by Fall Of Potential Method; --; Annual Maintenance Contract (AMC); Annually; Yes | - | - | - |
| Customized AMC/CMC for Pre-owned Products - Motor Current Signature Analysis Of 3 point 3 KV And 415 V Motors; --; Annual Maintenance Contract (AMC); Annually; Yes | - | - | - |
| Customized AMC/CMC for Pre-owned Products - Offline Elctrical Testing Of 1200 Kw 415 V DG Sets For RSO Step Voltage Surge Comparision winding Resistance AC Impedence IR And PI; --; Annual Maintenance Contract (AMC); Annually; Yes | - | - | - |
| Customized AMC/CMC for Pre-owned Products - Online Elctrical Testing Of 350 KW 250 VDC Motors For DC Motor current Signature Analysis; --; Annual Maintenance Contract (AMC); Annually; Yes | - | - | - |
| Customized AMC/CMC for Pre-owned Products - Ofline Elctrical Testing Of 350 KW 250 VDC Motors For DC Motor Circuit Analysis; --; Annual Maintenance Contract (AMC); Annually; Yes | - | - | - |
| Customized AMC/CMC for Pre-owned Products - Very Low Frequency Ten Delta And Partial Discharge Meaurement Of 3 Point 3 KV HT Cables; --; Annual Maintenance Contract (AMC); Annually; Yes | - | - | - |
| Customized AMC/CMC for Pre-owned Products - Dynamic Contacts Resistance Meaurement Of 245 KV SF6 Gas circuit Breaker; --; Annual Maintenance Contract (AMC); Annually; Yes | - | - | - |
| Customized AMC/CMC for Pre-owned Products - 245 KV SF6 Or Minimum Oil Circuit Breaker Open Close Timing Measurement Of All Three Phases; --; Annual Maintenance Contract (AMC); Annually; Yes | - | - | - |
₹1.0 L
9 Feb 2024
18 Jan 2024
9 Feb 2024
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_5859525.pdf
GEM_BID
1704696510.pdf
OTHER
1704696557.pdf
OTHER
1704697556.pdf
OTHER
above5lakH_c0789a13-eab4-409b-97d71705551422945_consignee2.rj.doc
OTHER
gtc.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .