Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹9.7 LAccepted-AOC H NO 765 VPO BIHTA TEHSIL BARARA DISTRICT AMBALA 133101 | AMBALA | AMBALA | HARYANA | 133101 | L-1 | Accepted-AOC Lowest | |
| 2 | L-2₹9.7 L+₹2,274 (0.24%)Rejected-Finance AMAR NIWAS RA 288 GANDHI CHOWK SADAR BAZAR KARNAL | KARNAL | KARNAL | HARYANA | L-2 | Rejected-Finance Highest |
Tender Value
₹8.9 L
EMD Value
₹17,800
Closing Date
24 Mar 2021, 5:00 pmClosed
Lalit Mohan Jindal
Executive Engineer, Elect. Divn. PWD B and R Br. Ambala Cantt.
Const. of Godowns for proper storage of estimates of EVM/VVPATs at Ambala City in Ambala Distt. (Pdg. Internal EI) (Recall).
2021_HRY_155495_2
PWD/Elect-KNL/Elect-AMB/110137
Open Tender
Construction Works
Works
120 days
Ambala Cantt.
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹17,800
18 Jun 2021
8 Mar 2021
25 Mar 2021
8 Mar 2021
24 Mar 2021
8 Mar 2021
Amount
( c ) Moulded case Circuit breakers. Supply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections. 15 amp.to 60 amp. 415 V ,10 KA 3-phase. HSR NO. 31.12 c (i)
100 amp.to 220 amp.415 V,10 KA 3-phase. HSR NO. 31.12 c (ii)
Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suiteble size of rag bolts with cement concrete ,duly painted with three coats of approved paint including one coat of red oxide. Size 40 mm x 40 mm x 6 mm. HSR NO. 31.13(ii)
M.S.Sheet . Supply and erection of 3 mm thick mild steel sheet duly welded on existing M.S. angle iron frame for fixing the main switches etc. as required, duly painted with three coats of approved paint including one coat of red oxide. HSR NO. 31.14 ( i )
(L) Miniature Circuit Breaker and Isolator. Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. SP MCB of 9 KA breaking capacity 6 amp. to 32 amp. HSR NO. 31.17a) (ii)
SPN MCB of 9 KA breaking capacity 6 amp. To 32 amp. HSR NO. 31.17(a) (ii)
TPN MCB of 9 KA breaking capacity 6 amp. to 32 amp. HSR NO. 31.17(a) (ii)
(M) Supply and erection of Fittings and Accessories. Call bell 220 / 230 volts A.C. bakelite with double coil. HSR NO. 31.18 (vii)
Bakelite angle / straight button holder large size. HSR NO. 31.18 (xi)
31.18 (xviii) Bakelite sheet including fixing with brass screws and washers. Erection only of 1x40 watts or 2x40 watts 1220 mm long / 1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjecent point. HSR NO. 31.18 (xxiv)
Supply and erection of hexagonal M.S. box 1.60 mm thick having each side 8 cms , 7.5 cms deep top covered with M.S. lid by means of screws including 10 mm dia 30 cm long mild steel rod made into suitable suspension hook and erected in RCC slab for erection of fan , the bottom covered with 3 mm thick bakelite sheet with suitable holes , painting etc. complete with all labour and material required to complete the job. . HSR NO. 31.18 (xxvi)
(O) Erection and carriage of fans.. Erection of ceiling fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work. HSR NO. 31.20 (i)
Erection of exhaust fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work. HSR NO. 31.20 (iii)
Pdg. and fixing of required size of deodar wood frame of section 50 mm x 32 mm for fixing exhaust fan upto 450 mm sweep. HSR NO. 31.20 (vi)
Supply and erection of PVC pipe of 6 kg. pressure laid 1 metre below ground level complete including digging refilling of the trench with jointing etc. PVC pipe 80 mm dia. HSR NO. 31.21(xxx) (b)
PVC pipe 65 mm dia. HSR NO. 31.21(xxx) (c)
(Q) Earthing Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required. HSR NO. 31.22(iii)
Earthing with tinned copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) comlete as required. HSR NO. 31.22(iv)
Extra for charcoal or coke and salt for G.I. Plate or copper plate earth electrode. HSR NO. 31.22(v)
Pdg. and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required . HSR NO. 31.22(x)
Pdg. and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode as required . HSR NO. 31.22(xi)
Pdg. and fixing 4.00 mm dia G.I.wire on surface or in recess for loop earthing as required . HSR NO. 31.22(xvi)
Pdg. and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required . HSR NO. 31.22(xvii)
(S) Under Ground Cables. Supply and erection of under ground cable 1 metre below ground level covered with sand and bricks including necessary connections,digging and refiling of trenches. . 35 Sq. mm 3.5 Core Cable . HSR NO. 31.25 (xxvi) Ard.
50 Sq. mm 3.5 Core Cable . HSR NO. 31.25 (xxvii) Ard.
120 Sq. mm 3.5 Core Cable . HSR NO. 31.25 (xxx) Ard.
Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections . 35 Sq. mm 3.5 Core Armoured Cable. HSR NO. 31.26 (xxvi)
50 Sq. mm 3.5 Core Armoured Cable. HSR NO. 31.26 (xxvii)
70 Sq. mm 3.5 Core Armoured Cable. HSR NO. 31.26 (xxviii)
Supply and erection of suitable compression type brass cable glands for underground Cable. 25 Sqmm to 50 Sqmm Cable 2 to 4 Core. HSR NO. 31.28 (iii)
70 Sqmm to 95 Sqmm Cable 3 to 3.5 Core . HSR NO. 31.28(iv)
120 Sqmm to 185 Sqmm Cable 3 to 3.5 Core HSR NO. 31.28 (v)
(A) PVC Insulated wiring in recessed conduit. Wiring in 1.5 sq.mm PVC Insulated copper conductor cable in 1.6 mm thick conduit pipe. Fan Point - Short. HSR NO. 31.36 (i)
Fan Point - Medium . HSR NO. 31.36 (i)b
Fan Point- Long. HSR NO. 31.36 c
Light point -Short. HSR NO. 31.36 (ii)a
Light Point - Medium. HSR NO. 31.36 b
Light Point- Long. HSR NO. 31.36 c
3 pin 5 amp. plug point including earthing the 3rd. pin etc. -Short point. HSR NO. 31.36 (vii) a
3 pin 5 amp plug point including earthing the 3rd. pin etc. - Medium point. HSR NO. 31.36 (vii) b
3 pin 5 amp. plug point including earthing the 3rd. pin etc.- Long point. HSR NO. 31.36 (vii) c
3 pin 15 amp plug point including earthing the 3 rd. pin etc.with 4 sq mm PVC insulated copper conductor cable - Long point. HSR NO. 31.36 (viii) c
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. Size 1.5 sqmm (3 / 0.81mm). HSR NO. 31.40 (i)
Size 2.50 sqmm (3 / 1.05mm). HSR NO. 31.40 (ii)
Size 4 sqmm (7 / 0.85mm). HSR NO. 31.40 (iii)
Supply and erection of double door sheet steel enclosures distribution boards suitable for MCBs and ELCBs etc. recessed in wall including bonding to earth with all labour and material requared complete the job in all respect upto the entire satisfaction of the Engineer-in Charge of the work. 8-way, SP & N (Horizontal) HSR NO. 31.41 (ii)
8-way, TP & N (Vertical) (8+24) HSR NO. 31.41 (vii)
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall / ceiling etc. including cost of PVC bends, inspection box and all other material required to complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work. 25 mm dia HSR NO. 31.44(b)
Supply and erection of MS sadles and clamps on wall / RCC parapit for fixing underground cable at distance of 0.60 metre centre to centre fixed by means of rawl plug including the cost of all labour and material required to complete the job in all respect. HSR NO. 31.48
Providing & fixing modular type accessories of approved make in existing box including fixing and making necessary connection, complete in all respect. 10 amp 1 way switch HSR NO. 31.56 (a)
10 amp 2 way switch HSR NO. 31.56 (b)
20 amp switch HSR NO. 31.56 (c )
10 amp socket HSR NO. 31.56 (d)
16 amp socket HSR NO. 31.56 (e)
Bell push HSR NO. 31.56 (f)
Fan regulator HSR NO. 31.56 (g)
Blinking Plate HSR NO. 31.56 (i)
Pdg and fixing GI concealed sheet metal boxes with inner an outer faceplate including concealing the box in wall and fixing in position with inner plate and face plate with all labour & material required for the job complete in all respect. 1 & 2 modules HSR NO. 31.57 (a)
3 modules HSR NO. 31.57 (b)
4 modules HSR NO. 31.57 (c )
6 modules HSR NO. 31.57 ( d)
8 modules HSR NO. 31.57 (e)
12 modules HSR NO. 31.57 (f)
Som Nath Contractor
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .