Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance GOVT CONTRACTOR VILLAGE GHUMALI P O AGAR TEHSIL FATEHPUR DISTT KANGRA HP | MANDI | HIMACHAL PRADESH | 175013 | Admitted-Finance |
| 3 | Admitted-Finance VILL BHOL KHAS PO LARTI TEH JAWALI DISTRICT KANGRA HP | MANDI | HIMACHAL PRADESH | 175013 | Admitted-Finance |
Tender Value
₹47.7 L
EMD Value
₹79,010
Closing Date
18 May 2022, 11:00 amClosed
Executive Engineer
Jal Shakti Division, Fatehpur
Sub Head Construction of 3 NO Delivery Tank 28 No Out Let Chamber 653 mtr Pucca field channel laying Jointing and Testing of HDPE pipe in distribution
2022_HPIPH_60344_1
EE-JSD-FTR-EE/22-1736-86
Open Tender
Civil Works
Item Rate
Fatehpur
As per notice inviting tender
8 documents required · 8 mandatory
₹800
Yes
EE Fatehpur
₹79,010
Yes
20 May 2022
5 May 2022
18 May 2022
5 May 2022
18 May 2022
5 May 2022
Amount
Excavation in foundation treanches(Pipe & Pits) up to all depths in all classification of earth work such as pick work,jumper work,saturated soil including bailing or pumping out water,blasting soft /hard rock where blasting is prohibited in all lifts including trimming & dressing of sides leveling of beds to correct grade i/c shoring/strutting planking,timbering & dewatering wherever required stacking the usable & unusable material/soil separately & after laying,jointing & testing of pipes,returning the useable soil in trenches in 15cm layers including consolidating of such deposited layer by raming & watering & then disposing of all surplus excavated soil/unusable material as directed with in all leads & lifts including restoration of unmetalled surface to its original condition & including cost of diversion for traffic,night signals,fixing caution boards,crossing over trenches for access to houses,fencing etc.complete in all respects with in all leads & lifts as per directions of Engineer-in-Charge.
Excavation in drains and channel etc.in all classification of soil suchas pick work, jumper work ,blasting hard and soft rock or chiseling including saturated soil ,bailing or pumping out water ,chiseling where blasting is probihited , shoring ,dewatering ,struting ,planking, timbering where ever required as directed with in all leads and lifts including restoration of metalled/un mettalled paved surface to its original condition including providing diversion for traffic night signal, fixing caution board crossing over access to houses ,fencing etc. complete in all respects with in all leads & lifts as per directions of Engineer-in-Charge.
Providing and laying cement conrete 1 : 4 : 8 . ( 1 cement : 4 sand and : 8 grade stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth upto all leads and lifts as per the direction and to the entire satisfaction of Engineer-in-Charge.
Providing and laying cement concrete 1:2:4 (1 cement: 2sand: 4graded crushed stone agg. 20mm nominal size) and curing complete excluding cost of form work in Foundation and plinth involving all leads and lifts as per the direction of Engineer in Charge
Foundation footings bases of columns and the like; and mass concreteas per direction and to the entire satisfaction of Engineer-in-Charge.
Walls any thickness but not less than 0.1m thickness including attached pillaster buttresses, plinth and string courses from top of foundation upto two level all floor level as per direction and to the entire satisfaction of Engineer-in-Charge.
Providing and laying cement concrete 1:5:10 (1cement;5sand:10graded stone aggregate 40mm nominal size) with 15% plum and curing complete excluding cost of form work in retaining wall/breast walls, the size of plums shall usually be 150mm to 300mm as per HPPWD specification as per the direction and entire satisfactionof Engineer-in-Charge.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish including centring, shuttering strutting and propping etc. with wooden batten and ballies, in all heights of propping and centring below supporting floor to ceiling not exceeding 4 mtrs and removal of the same for insitu-reinforced concrete and plain concrete work in :-
Vertical surfaces such as wall (any thickness) partitions and the like including attached pillasters, buttresses plinth and string courses and the like in all leads and lifts as per direction and to the entire satisfaction of Engineer-in-charge.
Providing mild steel/tor steel (reinforcement for RCC work) including bending,binding and placing in positioncomplete in all respect including all leads and lifts as per the direction and entire satisfaction of Engineer-in-Charge.
Providing & fixing PVC water stop seal of required size etc 4 mm to 6mm thick 150 mm vide, complete in all respect.and entire satisfaction of Engineer-in-Charge.
Providing & fixing bitumen fiber board, complete in all respect.and entire satisfaction of Engineer-in-Charge.
Laying, Jointing & Testing of HDPE (High Density Polythene Pipe) of following dia & class PE- 80 PN 4.0 confirming to IS: 4984-2016 with fusion welding process including all necessary fittings & bends (earth work to be paid for separately) within all leads and lifts complete in all respect as per the satisfaction of the Engineer-in-charge.
110 mm dia PE-80 PN4
125 mm dia PE-80 PN4
140 mm dia PE-80 PN4
160 mm dia PE-80 PN4
Providing and fixing cast iron alfa valve various dia of reputed make in oulet chamber to control the water for distribution system complete in all respect as per the entire satisfaction of Engineer in Charge.
150 mm dia
200 mm dia
Pumping Machinery (Tube-Well Nerna) Supply of submersible puming set make SABAR /KSB/Calama/Crompton.SU/Johnston confirming to BIS:8034-1976/5659-1970 (latest) suitable for clear water fitted with bronze impeller or suitable alloys directly coupled to squirel cage electric induction motor of same make as that of pump confirming to BIS:9283-1979 (latest with upto date ammendments) and totally water proof for submerssible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand non-vertical loads with minimum wear and tear. It should also be fitted with a device to take up expension of water with the heating of motor including water level guard, errection clamps, cable clips & depth guage etc. The pump shall be suitable for operation on data give below:-
(i) Location of site :-The site is located at a distance of 45 Kms.from Pathankot Railway Station. (ii) The altitude of place in which :-Altitude of place is 500 Metres above Mean Sea Level. The motor is intended to work:-(iii) Type of current :-A.C.Three phase supply with frequency 50 cycles per second. ( iv) Rated Voltage :-415 Vvolts (+/-) (v) 10%Characterstics of water :-(a).Temperature = 20oC (b).Turbidity =Upto 10NTU ©. Hardness =__Mg/Litre(as CaCo3) (d).Alkalinity =__Mg/Litre(as CaCo3) (f) PH =__ (g) Total solids____Mg/Litre___ (h). Others_____ (vi) Depth of Well Assembly :- 148.00 Metres,. (vii) L.W.L.in Tube-Well :- 60.00 Metres , (viii) Maximum draw down :- ......... Metres, (ix) Centre line level of Pump :-60.00 Metres , (x) Discharge level of highest point:- 155.50 Metres , (xi) Nos.of Pumps required :-1No. Pump. (xii) Capacity :- 11.62 L.P.S., (xiii) Total head in Metres :-99.78 Metres (xiv) Length of Rising Main :- 70 Metres ,(xv) Dia of Rising Main :- 150 mm dia GI Medium Class, (xvi) No.of working hours per day :- 20.00 Hours.(xvii) Limits of pump operation :- ( - ) 15% ( + ) 10% of total head. (xviii) H.P.of Motor/Drive unit :-Required H.P.of Pump at ( + ) 10% and ( - ) 15% of total head. BHP.with following margins/multiplying factor at duty point,whichever is higher. a).Upto 2 H.P. =1.5 (d) 10 to 20 H.P. =1.2, b).2 to 5 H.P. =1.4 (e) 20 to 100 H.P. =1.15 ,c) 5 to 10 H.P. =1.3 (f) Above 100 H.P. =1.10 (xix) Test Run :-16 Hours continueously for 7 days., b).2 to 5 H.P. =1.4 (e) 20 to 100 H.P. =1.15, c) 5 to 10 H.P. =1.3 (f) Above 100 H.P. =1.10 ,(xx) Test Run :-8 Hours continueously for 7 days. (1x30HP)
Supply , Installation, Testing and Commissioning of Fully Automatic LT Panel for submersible pump made out of 16 Gauge sheet powder coated dust and veremin proof wall mounted and front opering door type switch board with copper insulated wiring suitable to operate 1 nos. pump of rating 30 HP automatically through Variable Frequency Drive Starter. Starter should be capable to handle all the faults like short circuit, over current, under current, over voltage, under voltage, dry pump protection. It should get on and off command automatically from PLC and HMI. Monitoring and controlling of Pump running and tripping status should be monitored and controlled remotely through IOT enabled device. Access should be given to 3 users. of reputed Make.
Variable frequency drive starter of 30 HP Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It Should be capable to control the frequecy of pumps through out the operation and also should be capable to maintain the power factor of the system within acceptable limits. It should have ambient temperature 50 Degree without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. Make: Aarmation Electric Private Limited/MAS/ELLES.,(14.01)Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication Make L&T/Conserve/Siemens=1 No.(14.02) MCB /MCCB suitable capacity of L&T / Standard make on the coming feeder for pumping set confirming to BIS 2516-1985 ( Latest edition) with neutral linked under voltage release.=1 No.(14.03)Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments.=1 No. (14.04) Incommer MCCB with for proper short circuit capability for both the starters make L&T/Schnieder/ABB=1 No. (14.05) On / Off indicator and push button, Control and power wiring, 1No Power capacitor,Cooling fan 230 VAC, Contorl terminal, Buss Bar, i.e.Bolt, insulator, etc. (14.06) Input Choke which should be installed at the input of VFD starter, so that there should be proper protection in case of any voltage surge and distortions in signal. 1No (14.07) Control Transformer to safegaurd the control circuit of all the components from the voltage surges and spikes. 1No (14.08) Output contactors in the output of VFD to run the pump 1No. (14.09) Programmable logic controller with appropriate digital and analog inputs and outputs to give automatic command to star delta and also will get data from Multi function Meter for Current, Voltage, KWH, PF and THD. Make Mitsubishi/L&T/Delta 1No. (14.10) HMI 7" display with IOT to give on and off command manually and also to show pump running and breakdown status at pump station Make Wientek/Exor/Mitsubishi/Mecon.1No. (14.11) Supply of software with license to monitor data at Laptop/Mobile in form of Software and Mobile Application for 3 users 1No. (14.12) Level Sensor to indicate the water level of tank remotely 1No. (14.13) Cloud GateWay for Data Cluding to Server 1No. (14.14) Cable for Communication for Water Level Sensor. 1No.(14.15) Installation and Commissioning
Supply of Kirloskar/Kilburn/leader make case iron double flanged accututor swing check type reflux valve class PN 1.6 having bye pass arragngment (to be provided on delivery side of size of one size higher than the delivery size of pump and shall be sutable for with standing nominal seat pressrue of 16.32 Kg/Cm2 as per BIS 5312-1984 Part-I complete in all respect with in all leads & lifts as per directions and to the entire satisfaction of Engineer in Charge.
Supply of Kirloskar/ Kilburn/Leader make Cast iron double flanged accututor swing check type reflux valve class PN 1.6 having bye pass arrangement ( to be provided on delivery side) of size of one size higher than the delivery size of pump and shall be suitable for with standing nominal seat presure of 16.32 Kg/Cm2 as per BIS 5312-1984 Part-I complete in all respect with in all leads & lifts as per directions and to the entire satisfaction of Engineer in Charge. (Size and dia will be specified by the tendrer)
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/ Grandlay/ Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles ,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
On supply side of 3½ core coper cable 10 mm^2 ( From HPSEB Meter to Switch & Starter).
On motor side 3 core flat joint less copper cable of size 6 mm^2 ( From Switch & Starter to Motor) pump installed in the bore.
Supply of standarad make 100 mm dia circular/square dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
Laying ,jointing G.I./MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set . The pipe shall conform to relevant BIS codes & capable of with standing the feild test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers/ reducers, flanges, rubber gaskets 3mmthick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer-in-Charge. The pipe material shall conform to relevant BIS Code and capable of with standing FTP equal to 1.5 times the operating pressure the complete arrangement shall compromise of
Delivery pipe 125 mm dia
Providing and lying double loop earthing with coper plate 600x600 x3 thick electrode and copper strip of 25x3 complete including providing of material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, Copper /GI wire/ Strips of required capacity conforming to BIS 8034-1978 latest with upto date ammendments for above motor & other electriacl equipments including all civil works.
Errection of all equipments including cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Pumping Machinery (Tube-Well Golwan) Supply of submersible puming set make SABAR /KSB/Calama/Crompton.SU/Johnston confirming to BIS:8034-1976/5659-1970 (latest) suitable for clear water fitted with bronze impeller or suitable alloys directly coupled to squirel cage electric induction motor of same make as that of pump confirming to BIS:9283-1979 (latest with upto date ammendments) and totally water proof for submerssible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand non-vertical loads with minimum wear and tear. It should also be fitted with a device to take up expension of water with the heating of motor including water level guard, errection clamps, cable clips & depth guage etc. The pump shall be suitable for operation on data give below:-
(i) Location of site :-The site is located at a distance of 45 Kms.from Pathankot Railway Station. (ii) The altitude of place in which :-Altitude of place is 500 Metres above Mean Sea Level. The motor is intended to work:-(iii) Type of current :-A.C.Three phase supply with frequency 50 cycles per second. ( iv) Rated Voltage :-415 Vvolts (+/-) (v) 10%Characterstics of water :-(a).Temperature = 20oC (b).Turbidity =Upto 10NTU ©. Hardness =__Mg/Litre(as CaCo3) (d).Alkalinity =__Mg/Litre(as CaCo3) (f) PH =__ (g) Total solids____Mg/Litre___ (h). Others_____ (vi) Depth of Well Assembly :- 155.00 Metres,. (vii) L.W.L.in Tube-Well :- 65.00 Metres , (viii) Maximum draw down :- ... Metres, (ix) Centre line level of Pump :-65.00 Metres , (x) Discharge level of highest point:- 160.24 Metres , (xi) Nos.of Pumps required :-1No. Pump. (xii) Capacity :- 9.37 L.P.S.,(xiii) Total head in Metres :-124.55 Metres (xiv) Length of Rising Main :- 610 Metres ,(xv) Dia of Rising Main :- 100 mm dia GI Medium Class, (xvi) No.of working hours per day :- 20.00 Hours.(xvii) Limits of pump operation :- ( - ) 15% ( + ) 10% of total head. (xviii) H.P.of Motor/Drive unit :-Required H.P.of Pump at ( + ) 10% and ( - ) 15% of total head. BHP.with following margins/multiplying factor at duty point,whichever is higher. a).Upto 2 H.P. =1.5 (d) 10 to 20 H.P. =1.2, b).2 to 5 H.P. =1.4 (e) 20 to 100 H.P. =1.15 ,c) 5 to 10 H.P. =1.3 (f) Above 100 H.P. =1.10 (xix) Test Run :-16 Hours continueously for 7 days., b).2 to 5 H.P. =1.4 (e) 20 to 100 H.P. =1.15, c) 5 to 10 H.P. =1.3 (f) Above 100 H.P. =1.10 ,(xx) Test Run :-8 Hours continueously for 7 days. (1set of 30HP)
Supply , Installation, Testing and Commissioning of Fully Automatic LT Panel for submersible pump made out of 16 Gauge sheet powder coated dust and veremin proof wall mounted and front opering door type switch board with copper insulated wiring suitable to operate 1 nos. pump of rating 30 HP automatically through Variable Frequency Drive Starter. Starter should be capable to handle all the faults like short circuit, over current, under current, over voltage, under voltage, dry pump protection. It should get on and off command automatically from PLC and HMI. Monitoring and controlling of Pump running and tripping status should be monitored and controlled remotely through IOT enabled device. Access should be given to 3 users. of reputed Make.
Variable frequency drive starter of 30 HP Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It Should be capable to control the frequecy of pumps through out the operation and also should be capable to maintain the power factor of the system within acceptable limits. It should have ambient temperature 50 Degree without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. Make: Aarmation Electric Private Limited/MAS/ELLES.,(24.01)Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication Make L&T/Conserve/Siemens=1 No.(24.02) MCB /MCCB suitable capacity of L&T / Standard make on the coming feeder for pumping set confirming to BIS 2516-1985 ( Latest edition) with neutral linked under voltage release.=1 No.(24.03)Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments.=1 No. (24.04) Incommer MCCB with for proper short circuit capability for both the starters make L&T/Schnieder/ABB=1 No. (25.05) On / Off indicator and push button, Control and power wiring, Power capacitor,Cooling fan 230 VAC, Contorl terminal, Buss Bar, i.e.Bolt, insulator, etc. 1No (24.06)Input Choke which should be installed at the input of VFD starter, so that there should be proper protection in case of any voltage surge and distortions in signal. 1No (24.07) Control Transformer to safegaurd the control circuit of all the components from the voltage surges and spikes. 1No (24.08) Output contactors in the output of VFD to run the pump 1No. (24.09) Programmable logic controller with appropriate digital and analog inputs and outputs to give automatic command to star delta and also will get data from Multi function Meter for Current, Voltage, KWH, PF and THD. Make Mitsubishi/L&T/Delta 1No. (24.10) HMI 7" display with IOT to give on and off command manually and also to show pump running and breakdown status at pump station Make Wientek/Exor/Mitsubishi/Mecon.1No. (24.11) Supply of software with license to monitor data at Laptop/Mobile in form of Software and Mobile Application for 3 users 1No. (24.12) Level Sensor to indicate the water level of tank remotely 1No. (24.13) Cloud GateWay for Data Cluding to Server 1No. (24.14) Cable for Communication for Water Level Sensor. 1No.(24.15) Installation and Commissioning
Supply of fixing of double flanged acctuator cast iron sluice valve heavy size one dia higher tha pump size to delivery of pump class PN 1.6 of Kirloskar/Kilburn/Leader make conforming to BIS 14846-2000 laest with up to date ammendments having seat pressure of 16.32kg/cm2 complete in all respect with in all leads & lifts as per directions and to the entire satisfaction of Engineer in Charge. (Size/dia of valve specified by the tendrer).
Supply of Kirloskar/ Kilburn/Leader make Cast iron class PN1.6 double flanged swing check type reflux valve having by pass arrangement equal to dia of rising main i.e. 100 mm dia shall be suitable for withstanding nominal seat presure of 16.32 Kg/Cm2 as per BIS 5312-1984 (latest edition) complete in all respect with in all leads & lifts as per directions and to the entire satisfaction of Engineer in Charge.
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/ Grandlay/ Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles ,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
On supply side of 3½ core coper cable 10 mm^2 ( From HPSEB Meter to Switch & Starter).
On motor side 3 core flat joint less copper cable of size 6 mm^2 ( From Switch & Starter to Motor) pump installed in the bore.
Supply of standarad make 100 mm dia circular/square dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
Laying ,jointing G.I. pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set . The pipe shall conform to relevant BIS codes & capable of with standing the feild test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers/ reducers, flanges, rubber gaskets 3mmthick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer-in-Charge. The pipe material shall conform to relevant BIS Code and capable of with standing FTP equal to 1.5 times the operating pressure the complete arrangement shall compromise of
Delivery pipe 100 mm dia
Providing and lying double loop earthing with coper plate 600x600 x3 thick electrode and copper strip of 25x3 complete including providing of material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, Copper /GI wire/ Strips of required capacity conforming to BIS 8034-1978 latest with upto date ammendments for above motor & other electriacl equipments including all civil works.( for both machineries).
Errection of all equipments including cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Pumping Machinery (Tube-Well Mangdial) Supply of submersible puming set make SABAR /KSB/Calama/Crompton.SU/Johnston confirming to BIS:8034-1976/5659-1970 (latest) suitable for clear water fitted with bronze impeller or suitable alloys directly coupled to squirel cage electric induction motor of same make as that of pump confirming to BIS:9283-1979 (latest with upto date ammendments) and totally water proof for submerssible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand non-vertical loads with minimum wear and tear. It should also be fitted with a device to take up expension of water with the heating of motor including water level guard, errection clamps, cable clips & depth guage etc. The pump shall be suitable for operation on data give below:-
(i) Location of site :-The site is located at a distance of 45 Kms.from Pathankot Railway Station. (ii) The altitude of place in which :-Altitude of place is 500 Metres above Mean Sea Level. The motor is intended to work:-(iii) Type of current :-A.C.Three phase supply with frequency 50 cycles per second. ( iv) Rated Voltage :-415 Vvolts (+/-) (v) 10%Characterstics of water :-(a).Temperature = 20oC (b).Turbidity =Upto 10NTU ©. Hardness =__Mg/Litre(as CaCo3) (d).Alkalinity =__Mg/Litre(as CaCo3) (f) PH =__ (g) Total solids____Mg/Litre___ (h). Others_____ (vi) Depth of Well Assembly :- 155.00 Metres,. (vii) L.W.L.in Tube-Well :- 60.00 Metres , (viii) Maximum draw down :-.... Metres, (ix) Centre line level of Pump :-60.00 Metres , (x) Discharge level of highest point:- 185.50 Metres , (xi) Nos.of Pumps required :-1No. Pump. (xii) Capacity :- 11.28 L.P.S.,(xiii) Total head in Metres :-146.19 Metres (xiv) Length of Rising Main :- 950 Metres ,(xv) Dia of Rising Main :- 125 mm dia GI Medium Class, (xvi) No.of working hours per day :- 20.00 Hours.(xvii) Limits of pump operation :- ( - ) 15% ( + ) 10% of total head. (xviii) H.P.of Motor/Drive unit :-Required H.P.of Pump at ( + ) 10% and ( - ) 15% of total head. BHP.with following margins/multiplying factor at duty point,whichever is higher. a).Upto 2 H.P. =1.5 (d) 10 to 20 H.P. =1.2, b).2 to 5 H.P. =1.4 (e) 20 to 100 H.P. =1.15 ,c) 5 to 10 H.P. =1.3 (f) Above 100 H.P. =1.10 (xix) Test Run :-16 Hours continueously for 7 days., b).2 to 5 H.P. =1.4 (e) 20 to 100 H.P. =1.15, c) 5 to 10 H.P. =1.3 (f) Above 100 H.P. =1.10 ,(xx) Test Run :-8 Hours continueously for 7 days. (1x45HP)
Supply , Installation, Testing and Commissioning of Fully Automatic LT Panel for submersible pump made out of 16 Gauge sheet powder coated dust and veremin proof wall mounted and front opering door type switch board with copper insulated wiring suitable to operate 1 nos. pump of rating 45 HP automatically through Variable Frequency Drive Starter. Starter should be capable to handle all the faults like short circuit, over current, under current, over voltage, under voltage, dry pump protection. It should get on and off command automatically from PLC and HMI. Monitoring and controlling of Pump running and tripping status should be monitored and controlled remotely through IOT enabled device. Access should be given to 3 users. of reputed Make.
Variable frequency drive starter of 45 HP Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It Should be capable to control the frequecy of pumps through out the operation and also should be capable to maintain the power factor of the system within acceptable limits. It should have ambient temperature 50 Degree without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. Make: Aarmation Electric Private Limited/MAS/ELLES.,(34.01)Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication Make L&T/Conserve/Siemens=1 No.(34.02) MCB /MCCB suitable capacity of L&T / Standard make on the coming feeder for pumping set confirming to BIS 2516-1985 ( Latest edition) with neutral linked under voltage release.=1 No.(34.03)Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments.=1 No. (34.04) Incommer MCCB with for proper short circuit capability for both the starters make L&T/Schnieder/ABB=1 No. (34.05) On / Off indicator and push button, Control and power wiring, 1No (34.06) Power capacitor,Cooling fan 230 VAC, Contorl terminal, Buss Bar, i.e.Bolt, insulator, etc. 1 No. (34.07)Input Choke which should be installed at the input of VFD starter, so that there should be proper protection in case of any voltage surge and distortions in signal. 1No (34.08) Control Transformer to safegaurd the control circuit of all the components from the voltage surges and spikes. 1No (34.09) Output contactors in the output of VFD to run the pump 1No. (34.10) Programmable logic controller with appropriate digital and analog inputs and outputs to give automatic command to star delta and also will get data from Multi function Meter for Current, Voltage, KWH, PF and THD. Make Mitsubishi/L&T/Delta 1No. (34.11) HMI 7" display with IOT to give on and off command manually and also to show pump running and breakdown status at pump station Make Wientek/Exor/Mitsubishi/Mecon.1No. (34.12) Supply of software with license to monitor data at Laptop/Mobile in form of Software and Mobile Application for 3 users 1No. (34.13) Level Sensor to indicate the water level of tank remotely 1No. (34.14) Cloud GateWay for Data Cluding to Server 1No. (34.15) Cable for Communication for Water Level Sensor. 1No.(34.16) Installation and Commissioning
Supply of fixing of double flanged acctuator cast iron sluice valve heavy size one dia higher tha pump size to delivery of pump class PN 1.6 of Kirloskar/Kilburn/Leader make conforming to BIS 14846-2000 laest with up to date ammendments having seat pressure of 16.32kg/cm2 complete in all respect with in all leads & lifts as per directions and to the entire satisfaction of Engineer in Charge. (size will be specified by the tenderer)
Supply of Kirloskar/ Kilburn/Leader make Cast iron double flanged accututor swing check type reflux valve class PN 1.6 having bye pass arrangement ( to be provided on delivery side) of size of one size higher than the delivery size of pump and shall be suitable for with standing nominal seat presure of 16.32Kg/Cm2 as per BIS 5312-1984 Part-I complete in all respect with in all leads & lifts as per directions and to the entire satisfaction of Engineer in Charge. (size/dia will be specified by the tenderer)
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/ Grandlay/ Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles ,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
On supply side of 3½ core coper cable 16 mm^2 ( From HPSEB Meter to Switch & Starter).
On motor side 3 core flat joint less copper cable of size 10 mm^2 ( From Switch & Starter to Motor) pump installed in the bore.
Supply of standarad make 100 mm dia circular/square dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
Laying ,jointing G.I./MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set . The pipe shall conform to relevant BIS codes & capable of with standing the feild test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers/ reducers, flanges, rubber gaskets 3mmthick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer-in-Charge. The pipe material shall conform to relevant BIS Code and capable of with standing FTP equal to 1.5 times the operating pressure the complete arrangement shall compromise of
Delivery pipe 100 mm dia
Providing and lying double loop earthing with coper plate 600x600 x3 thick electrode and copper strip of 25x3 complete including providing of material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, Copper /GI wire/ Strips of required capacity conforming to BIS 8034-1978 latest with upto date ammendments for above motor & other electriacl equipments including all civil works. (for both machineries)
Errection of all equipments including cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Laying and jointing in trenches to be levelled to grade, BIS marked GI flanged pipes confirming to BIS:1239 (latest with upto date ammendments) of following dia (Medium class) duly flanged to be welded every fifth pipe ,interval of pipe with intermediate butt welded joints including the cost of flanges, bends/short pieces made from parent tubes of diferent degrees cutting welding and jointing with flanges conforming to tables as specified below of BIS: 6392 (latest with upto date ammendments) welded at both ends as per BIS:816 (latest with upto date ammendments) with electrodes confirming to BIS 814 (latest with upto date ammendments) & provided with nuts and bolts BIS: 1369 (latest with upto date ammendments) of required sizes 4 mm thick champion make compressed asbestos fiber gasket or synthetic rubber gasket confirming to BIS:2712 (latest with upto date ammendments) & approved specifications as per site conditions including flushing cleaning and hydraulic testing complet to the best satisfaction of Engineer in charge complete in all respects with in all leads & lifts as per directions and to the entire satisfaction of Engineer-in-Charge. (The cost of MS flange butt welding of excavation will be measured & paid for sapartely.
150 mm dia GI. (Medium Class) Table-5
100 mm dia GI. (Medium Class) Table-5
125 mm dia GI. (Medium Class) Table-5
Providing welding & fixing of MS flanges cinfirming to IS:6392-1971 (Latest with upto date amendments) and welding of MS Flanges with G.I. Pipes pipes in two layers in outer side and one layer inner side of both faces to make the joint leak proof (The cost of providing and laying of G.I.Pipes/MSERW Pipes to be measured and paid for separately). The welding of flanges should conform to IS 816-1969 with electrode as per IS : 814-1991 and required number of nuts & bolts conforming to IS: 1364. The thickness of gasket not less than 3.00mm conforming to IS : 2712-1998. The work shall be done as per entire satisfaction of Engineer-in-Charge within all leads and lifts. ( MS Flanges to be welded after 30 metre interval of pipe)
150 mm dia GI. (Medium Class)
100 mm dia GI. (Medium Class)
125 mm dia GI. (Medium Class)
Providing circumferential butt welding joints GI pipe ( Medium Class) 150 mm dia ,100 mm dia ,125 mm dia two layer on each end of welding using 3 mm and 4 mm dia electrodes after levering the pipes ends according to relevant ISI specification complete in all respects with in all leads & lifts as per directions of Engineer-in-Charge
150 mm dia GI. (Medium Class)
100 mm dia GI. (Medium Class)
125 mm dia GI. (Medium Class)
VARINDER SINGH RANA
SANJAY GOUR
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .