Provision of Emergency Lighting at Railway Stations for Improvement of Minimum Essential Amenities & Divyangjan Facilities over Katihar Division in West Bengal Portion.
33_2026
33_2026
Open
6 Months
Katihar, Bihar
₹0
₹4.1 L
17 Jun 2026
17 Jun 2026
29 Jun 2026
A-PART-A (Under the Jurisdiction of SSE/Elect./P/IC/MLDT) (Section =
B-PART-B (Under the Jurisdiction of SSE/Elect./P/IC/MLDT) (Section =
C-PART-C (Under the Jurisdiction of SSE/Elect./P/IC/BOE) (Section = RGJ-
D-PART-D (Under the Jurisdiction of SSE/Elect./P/IC/KNE) (Section = DLK-
E-PART-E (Under the Jurisdiction of SSE/Elect./P/IC/NJP) (Section = TMH-
F-PART-F (Under the Jurisdiction of SSE/Elect./P/IC/SGUJ) (Section =
Item Breakup - A-PART-A (Under the Jurisdiction of SSE/Elect./P/IC/MLDT) (Section = KDPR-MLFC)
Supply, erection, testing & commissioning of CLS Numbers PANNEL 150 A, Automatic Changeover Control Panel for Colour Light Signaling system of 25 KVA 150 A capacity as per CORE approved RDSO specification No. TI / SPC / PSI / CLS / 0023 with A&C slip as per instruction of Engineer Incharge at Site.
Supply, erection, testing & commissioning of CLS Numbers PANNEL 60 A, Automatic Changeover Control Panel for Colour Light Signaling system of 10 KVA 60 A capacity as per CORE approved RDSO specification No. TI / SPC / PSI / CLS / 0023 with A&C slip. as per instruction of Engineer Incharge at Site.
Supply & fixing of rain proof MS box of suitable Numbers size for housing MCCB with hinged and lockable door on AT mast with suitable MS clamps and should be painted and powder coated MCCB 63 Amp. 3/4 pole 25 KA B/C as per instruction of Engineer Incharge at Site.
Supply & erection of 240 V L.T. Distribution Numbers Boards for 5/10/25 kVA L.T supply transformer with 01 no. MCCB for incoming and 63A MCB for outgoing as per relevant specification as per instruction of Engineer Incharge at Site.
Supply of LV Terminal termination of XLPE Cable.
Erection of LV Terminal termination of XLPE Cable.
Supply of Copper Strip for Equipment Earthing.
Erection of Copper Strip for Equipment Earthing. Metre
Horizontal machine boring of 300 mm dia hole Metre across track/Road/High drain etc. at a depth of 1.0 mtr below of ground level with suitable boring instruments & neessary arrangement and as per technical procedure.
Supply, laying, commissioning & testing of CI Metre Pipe 150 mm dia Class LA type (IS 1536-2001) to be laid partly along the pole and partly through ground under railway track/road in cable trench for protection of cable with suitable fixing arrangement by MS clamp, nut, bolt, washer etc. as per instruction of Engineer incharge at site. KATIHAR DIVISION-ELECTRICAL/N F RLY
Supply, fixing, testing & commissioning of IP Numbers 66/67 thermoplastic cable junction box / loop box of size (300 x 450 x 170) mm with knockouts & 04 nos terminals as per instruction of Engineer Incharge at Site.
Supply & Erection of earth by 50 mm dia 3 Mtrs. Numbers long (3.6 mm thickness) GI pipe, 32x6 mm GI strip- 5 Mtrs, GI nuts, bolts including masonry materials for earthing pit, salt, charcoal, soldered end terminal etc. and construction of earth pit covered with RCC cover slab12.7 mm thickness and watering pipe as per Drg. No.- PCEE/ELG/DRG/2024/1 Date:- 30.09.2024 and as per instruction of Engineer Incharge at site.
Cutting of Road/Pucca/Hard Soil below (0.3 x 1) Metre mt from ground level and make it good as original with supply & execution of CC work (1:3:6) as per instruction of Engineer incharge at site.
Laying, commissioning & testing of HT/LT Metre XLPE/PVC cable of different sizes partly along the pole and partly through ground in cable trench by excavation of ground below 1/1.5 mt from ground level with suitable fixing arrangement by MS clamp of size 50x6 mm and suitable size nut, bolt. Loading, Unloading & Carrying of cable to actual work site by contractor's own arrangement. (Aluminium Crimping Socket should be provided for each Cable Termination). (Cable will be supplied by Railway)
Cable Trench Cutting of LT XLPE insulated Metre armoured, aluminium conductor cable, making good the damages, end terminations with aluminium crimping socket/plugs, provisions of cable route markers, testing & commissioning etc. as required as per technical specifications of different size armoured cable as per instruction of Engineer Incharge at Site. Total 3824623.00
Item Breakup - B-PART-B (Under the Jurisdiction of SSE/Elect./P/IC/MLDT) (Section = GZO-BLGT & SQB)
Supply, erection, testing & commissioning of CLS Numbers PANNEL 150 A, Automatic Changeover Control Panel for Colour Light Signaling system of 25 KVA 150 A capacity as per CORE approved RDSO specification No. TI / SPC / PSI / CLS / 0023 with A&C slip as per instruction of Engineer Incharge at Site.
Supply, erection, testing & commissioning of CLS Numbers PANNEL 60 A, Automatic Changeover Control Panel for Colour Light Signaling system of 10 KVA 60 A capacity as per CORE approved RDSO specification No. TI / SPC / PSI / CLS / 0023 with A&C slip. as per instruction of Engineer Incharge at Site.
Supply & fixing of rain proof MS box of suitable Numbers size for housing MCCB with hinged and lockable door on AT mast with suitable MS clamps and should be painted and powder coated MCCB 63 Amp. 3/4 pole 25 KA B/C as per instruction of Engineer Incharge at Site. KATIHAR DIVISION-ELECTRICAL/N F RLY
Supply & erection of 240 V L.T. Distribution Numbers Boards for 5/10/25 kVA L.T supply transformer with 01 no. MCCB for incoming and 63A MCB for outgoing as per relevant specification as per instruction of Engineer Incharge at Site.
Supply of LV Terminal termination of XLPE Cable.
Erection of LV Terminal termination of XLPE Cable.
Supply of Copper Strip for Equipment Earthing.
Erection of Copper Strip for Equipment Earthing. Metre
Horizontal machine boring of 300 mm dia hole Metre across track/Road/High drain etc. at a depth of 1.0 mtr below of ground level with suitable boring instruments & neessary arrangement and as per technical procedure.
Supply, laying, commissioning & testing of CI Metre Pipe 150 mm dia Class LA type (IS 1536-2001) to be laid partly along the pole and partly through ground under railway track/road in cable trench for protection of cable with suitable fixing arrangement by MS clamp, nut, bolt, washer etc. as per instruction of Engineer incharge at site.
Supply, fixing, testing & commissioning of IP Numbers 66/67 thermoplastic cable junction box / loop box of size (300 x 450 x 170) mm with knockouts & 04 nos terminals as per instruction of Engineer Incharge at Site.
Supply & Erection of earth by 50 mm dia 3 Mtrs. Numbers long (3.6 mm thickness) GI pipe, 32x6 mm GI strip- 5 Mtrs, GI nuts, bolts including masonry materials for earthing pit, salt, charcoal, soldered end terminal etc. and construction of earth pit covered with RCC cover slab12.7 mm thickness and watering pipe as per Drg. No.- PCEE/ELG/DRG/2024/1 Date:- 30.09.2024 and as per instruction of Engineer Incharge at site.
Cutting of Road/Pucca/Hard Soil below (0.3 x 1) Metre mt from ground level and make it good as original with supply & execution of CC work (1:3:6) as per instruction of Engineer incharge at site.
Laying, commissioning & testing of HT/LT Metre XLPE/PVC cable of different sizes partly along the pole and partly through ground in cable trench by excavation of ground below 1/1.5 mt from ground level with suitable fixing arrangement by MS clamp of size 50x6 mm and suitable size nut, bolt. Loading, Unloading & Carrying of cable to actual work site by contractor's own arrangement. (Aluminium Crimping Socket should be provided for each Cable Termination). (Cable will be supplied by Railway)
Cable Trench Cutting of LT XLPE insulated Metre armoured, aluminium conductor cable, making good the damages, end terminations with aluminium crimping socket/plugs, provisions of cable route markers, testing & commissioning etc. as required as per technical specifications of different size armoured cable as per instruction of Engineer Incharge at Site. Total 3115068.00
Item Breakup - C-PART-C (Under the Jurisdiction of SSE/Elect./P/IC/BOE) (Section = RGJ-RDP)
Supply, erection, testing & commissioning of CLS Numbers PANNEL 150 A, Automatic Changeover Control Panel for Colour Light Signaling system of 25 KVA 150 A capacity as per CORE approved RDSO specification No. TI / SPC / PSI / CLS / 0023 with A&C slip as per instruction of Engineer Incharge at Site.
Supply, erection, testing & commissioning of CLS Numbers PANNEL 60 A, Automatic Changeover Control Panel for Colour Light Signaling system of 10 KVA 60 A capacity as per CORE approved RDSO specification No. TI / SPC / PSI / CLS / 0023 with A&C slip. as per instruction of Engineer Incharge at Site.
Supply & fixing of rain proof MS box of suitable Numbers size for housing MCCB with hinged and lockable door on AT mast with suitable MS clamps and should be painted and powder coated MCCB 63 Amp. 3/4 pole 25 KA B/C as per instruction of Engineer Incharge at Site.
Supply & erection of 240 V L.T. Distribution Numbers Boards for 5/10/25 kVA L.T supply transformer with 01 no. MCCB for incoming and 63A MCB for outgoing as per relevant specification as per instruction of Engineer Incharge at Site.
Supply of LV Terminal termination of XLPE Cable.
Erection of LV Terminal termination of XLPE Cable.
Supply of Copper Strip for Equipment Earthing.
Erection of Copper Strip for Equipment Earthing. Metre
Horizontal machine boring of 300 mm dia hole Metre across track/Road/High drain etc. at a depth of 1.0 mtr below of ground level with suitable boring instruments & neessary arrangement and as per technical procedure.
Supply, laying, commissioning & testing of CI Metre Pipe 150 mm dia Class LA type (IS 1536-2001) to be laid partly along the pole and partly through ground under railway track/road in cable trench for protection of cable with suitable fixing arrangement by MS clamp, nut, bolt, washer etc. as per instruction of Engineer incharge at site.
Supply, fixing, testing & commissioning of IP Numbers 66/67 thermoplastic cable junction box / loop box of size (300 x 450 x 170) mm with knockouts & 04 nos terminals as per instruction of Engineer Incharge at Site.
Supply & Erection of earth by 50 mm dia 3 Mtrs. Numbers long (3.6 mm thickness) GI pipe, 32x6 mm GI strip- 5 Mtrs, GI nuts, bolts including masonry materials for earthing pit, salt, charcoal, soldered end terminal etc. and construction of earth pit covered with RCC cover slab12.7 mm thickness and watering pipe as per Drg. No.- PCEE/ELG/DRG/2024/1 Date:- 30.09.2024 and as per instruction of Engineer Incharge at site.
Cutting of Road/Pucca/Hard Soil below (0.3 x 1) Metre mt from ground level and make it good as original with supply & execution of CC work (1:3:6) as per instruction of Engineer incharge at site. KATIHAR DIVISION-ELECTRICAL/N F RLY
Laying, commissioning & testing of HT/LT Metre XLPE/PVC cable of different sizes partly along the pole and partly through ground in cable trench by excavation of ground below 1/1.5 mt from ground level with suitable fixing arrangement by MS clamp of size 50x6 mm and suitable size nut, bolt. Loading, Unloading & Carrying of cable to actual work site by contractor's own arrangement. (Aluminium Crimping Socket should be provided for each Cable Termination). (Cable will be supplied by Railway)
Cable Trench Cutting of LT XLPE insulated Metre armoured, aluminium conductor cable, making good the damages, end terminations with aluminium crimping socket/plugs, provisions of cable route markers, testing & commissioning etc. as required as per technical specifications of different size armoured cable as per instruction of Engineer Incharge at Site. Total 2887803.00
Item Breakup - D-PART-D (Under the Jurisdiction of SSE/Elect./P/IC/KNE) (Section = DLK-AUB)
Supply, erection, testing & commissioning of CLS Numbers PANNEL 150 A, Automatic Changeover Control Panel for Colour Light Signaling system of 25 KVA 150 A capacity as per CORE approved RDSO specification No. TI / SPC / PSI / CLS / 0023 with A&C slip as per instruction of Engineer Incharge at Site.
Supply, erection, testing & commissioning of CLS Numbers PANNEL 60 A, Automatic Changeover Control Panel for Colour Light Signaling system of 10 KVA 60 A capacity as per CORE approved RDSO specification No. TI / SPC / PSI / CLS / 0023 with A&C slip. as per instruction of Engineer Incharge at Site.
Supply & fixing of rain proof MS box of suitable Numbers size for housing MCCB with hinged and lockable door on AT mast with suitable MS clamps and should be painted and powder coated MCCB 63 Amp. 3/4 pole 25 KA B/C as per instruction of Engineer Incharge at Site.
Supply & erection of 240 V L.T. Distribution Numbers Boards for 5/10/25 kVA L.T supply transformer with 01 no. MCCB for incoming and 63A MCB for outgoing as per relevant specification as per instruction of Engineer Incharge at Site.
Supply of LV Terminal termination of XLPE Cable.
Erection of LV Terminal termination of XLPE Cable.
Supply of Copper Strip for Equipment Earthing.
Erection of Copper Strip for Equipment Earthing. Metre
Horizontal machine boring of 300 mm dia hole Metre across track/Road/High drain etc. at a depth of 1.0 mtr below of ground level with suitable boring instruments & neessary arrangement and as per technical procedure. KATIHAR DIVISION-ELECTRICAL/N F RLY
Supply, laying, commissioning & testing of CI Metre Pipe 150 mm dia Class LA type (IS 1536-2001) to be laid partly along the pole and partly through ground under railway track/road in cable trench for protection of cable with suitable fixing arrangement by MS clamp, nut, bolt, washer etc. as per instruction of Engineer incharge at site.
Supply, fixing, testing & commissioning of IP Numbers 66/67 thermoplastic cable junction box / loop box of size (300 x 450 x 170) mm with knockouts & 04 nos terminals as per instruction of Engineer Incharge at Site.
Supply & Erection of earth by 50 mm dia 3 Mtrs. Numbers long (3.6 mm thickness) GI pipe, 32x6 mm GI strip- 5 Mtrs, GI nuts, bolts including masonry materials for earthing pit, salt, charcoal, soldered end terminal etc. and construction of earth pit covered with RCC cover slab12.7 mm thickness and watering pipe as per Drg. No.- PCEE/ELG/DRG/2024/1 Date:- 30.09.2024 and as per instruction of Engineer Incharge at site.
Cutting of Road/Pucca/Hard Soil below (0.3 x 1) Metre mt from ground level and make it good as original with supply & execution of CC work (1:3:6) as per instruction of Engineer incharge at site.
Laying, commissioning & testing of HT/LT Metre XLPE/PVC cable of different sizes partly along the pole and partly through ground in cable trench by excavation of ground below 1/1.5 mt from ground level with suitable fixing arrangement by MS clamp of size 50x6 mm and suitable size nut, bolt. Loading, Unloading & Carrying of cable to actual work site by contractor's own arrangement. (Aluminium Crimping Socket should be provided for each Cable Termination). (Cable will be supplied by Railway)
Cable Trench Cutting of LT XLPE insulated Metre armoured, aluminium conductor cable, making good the damages, end terminations with aluminium crimping socket/plugs, provisions of cable route markers, testing & commissioning etc. as required as per technical specifications of different size armoured cable as per instruction of Engineer Incharge at Site. Total 3583478.00
Item Breakup - E-PART-E (Under the Jurisdiction of SSE/Elect./P/IC/NJP) (Section = TMH-HDB)
Supply, erection, testing & commissioning of CLS Numbers PANNEL 150 A, Automatic Changeover Control Panel for Colour Light Signaling system of 25 KVA 150 A capacity as per CORE approved RDSO specification No. TI / SPC / PSI / CLS / 0023 with A&C slip as per instruction of Engineer Incharge at Site.
Supply, erection, testing & commissioning of CLS Numbers PANNEL 60 A, Automatic Changeover Control Panel for Colour Light Signaling system of 10 KVA 60 A capacity as per CORE approved RDSO specification No. TI / SPC / PSI / CLS / 0023 with A&C slip. as per instruction of Engineer Incharge at Site. KATIHAR DIVISION-ELECTRICAL/N F RLY
Supply & fixing of rain proof MS box of suitable Numbers size for housing MCCB with hinged and lockable door on AT mast with suitable MS clamps and should be painted and powder coated MCCB 63 Amp. 3/4 pole 25 KA B/C as per instruction of Engineer Incharge at Site.
Supply & erection of 240 V L.T. Distribution Numbers Boards for 5/10/25 kVA L.T supply transformer with 01 no. MCCB for incoming and 63A MCB for outgoing as per relevant specification as per instruction of Engineer Incharge at Site.
Supply of LV Terminal termination of XLPE Cable.
Erection of LV Terminal termination of XLPE Cable.
Supply of Copper Strip for Equipment Earthing.
Erection of Copper Strip for Equipment Earthing. Metre
Horizontal machine boring of 300 mm dia hole Metre across track/Road/High drain etc. at a depth of 1.0 mtr below of ground level with suitable boring instruments & neessary arrangement and as per technical procedure.
Supply, laying, commissioning & testing of CI Metre Pipe 150 mm dia Class LA type (IS 1536-2001) to be laid partly along the pole and partly through ground under railway track/road in cable trench for protection of cable with suitable fixing arrangement by MS clamp, nut, bolt, washer etc. as per instruction of Engineer incharge at site.
Supply, fixing, testing & commissioning of IP Numbers 66/67 thermoplastic cable junction box / loop box of size (300 x 450 x 170) mm with knockouts & 04 nos terminals as per instruction of Engineer Incharge at Site.
Supply & Erection of earth by 50 mm dia 3 Mtrs. Numbers long (3.6 mm thickness) GI pipe, 32x6 mm GI strip- 5 Mtrs, GI nuts, bolts including masonry materials for earthing pit, salt, charcoal, soldered end terminal etc. and construction of earth pit covered with RCC cover slab12.7 mm thickness and watering pipe as per Drg. No.- PCEE/ELG/DRG/2024/1 Date:- 30.09.2024 and as per instruction of Engineer Incharge at site.
Cutting of Road/Pucca/Hard Soil below (0.3 x 1) Metre mt from ground level and make it good as original with supply & execution of CC work (1:3:6) as per instruction of Engineer incharge at site.
Laying, commissioning & testing of HT/LT Metre XLPE/PVC cable of different sizes partly along the pole and partly through ground in cable trench by excavation of ground below 1/1.5 mt from ground level with suitable fixing arrangement by MS clamp of size 50x6 mm and suitable size nut, bolt. Loading, Unloading & Carrying of cable to actual work site by contractor's own arrangement. (Aluminium Crimping Socket should be provided for each Cable Termination). (Cable will be supplied by Railway) KATIHAR DIVISION-ELECTRICAL/N F RLY
Cable Trench Cutting of LT XLPE insulated Metre armoured, aluminium conductor cable, making good the damages, end terminations with aluminium crimping socket/plugs, provisions of cable route markers, testing & commissioning etc. as required as per technical specifications of different size armoured cable as per instruction of Engineer Incharge at Site. Total 4134456.00
Item Breakup - F-PART-F (Under the Jurisdiction of SSE/Elect./P/IC/SGUJ) (Section = ADQ-SGUT)
Supply, erection, testing & commissioning of CLS Numbers PANNEL 150 A, Automatic Changeover Control Panel for Colour Light Signaling system of 25 KVA 150 A capacity as per CORE approved RDSO specification No. TI / SPC / PSI / CLS / 0023 with A&C slip as per instruction of Engineer Incharge at Site.
Supply, erection, testing & commissioning of CLS Numbers PANNEL 60 A, Automatic Changeover Control Panel for Colour Light Signaling system of 10 KVA 60 A capacity as per CORE approved RDSO specification No. TI / SPC / PSI / CLS / 0023 with A&C slip. as per instruction of Engineer Incharge at Site.
Supply & fixing of rain proof MS box of suitable Numbers size for housing MCCB with hinged and lockable door on AT mast with suitable MS clamps and should be painted and powder coated MCCB 63 Amp. 3/4 pole 25 KA B/C as per instruction of Engineer Incharge at Site.
Supply & erection of 240 V L.T. Distribution Numbers Boards for 5/10/25 kVA L.T supply transformer with 01 no. MCCB for incoming and 63A MCB for outgoing as per relevant specification as per instruction of Engineer Incharge at Site.
Supply of LV Terminal termination of XLPE Cable.
Erection of LV Terminal termination of XLPE Cable.
Supply of Copper Strip for Equipment Earthing.
Erection of Copper Strip for Equipment Earthing. Metre
Horizontal machine boring of 300 mm dia hole Metre across track/Road/High drain etc. at a depth of 1.0 mtr below of ground level with suitable boring instruments & neessary arrangement and as per technical procedure.
Supply, laying, commissioning & testing of CI Metre Pipe 150 mm dia Class LA type (IS 1536-2001) to be laid partly along the pole and partly through ground under railway track/road in cable trench for protection of cable with suitable fixing arrangement by MS clamp, nut, bolt, washer etc. as per instruction of Engineer incharge at site.
Supply, fixing, testing & commissioning of IP Numbers 66/67 thermoplastic cable junction box / loop box of size (300 x 450 x 170) mm with knockouts & 04 nos terminals as per instruction of Engineer Incharge at Site. KATIHAR DIVISION-ELECTRICAL/N F RLY
Supply & Erection of earth by 50 mm dia 3 Mtrs. Numbers long (3.6 mm thickness) GI pipe, 32x6 mm GI strip- 5 Mtrs, GI nuts, bolts including masonry materials for earthing pit, salt, charcoal, soldered end terminal etc. and construction of earth pit covered with RCC cover slab12.7 mm thickness and watering pipe as per Drg. No.- PCEE/ELG/DRG/2024/1 Date:- 30.09.2024 and as per instruction of Engineer Incharge at site.
Cutting of Road/Pucca/Hard Soil below (0.3 x 1) Metre mt from ground level and make it good as original with supply & execution of CC work (1:3:6) as per instruction of Engineer incharge at site.
Laying, commissioning & testing of HT/LT Metre XLPE/PVC cable of different sizes partly along the pole and partly through ground in cable trench by excavation of ground below 1/1.5 mt from ground level with suitable fixing arrangement by MS clamp of size 50x6 mm and suitable size nut, bolt. Loading, Unloading & Carrying of cable to actual work site by contractor's own arrangement. (Aluminium Crimping Socket should be provided for each Cable Termination). (Cable will be supplied by Railway)
Cable Trench Cutting of LT XLPE insulated Metre armoured, aluminium conductor cable, making good the damages, end terminations with aluminium crimping socket/plugs, provisions of cable route markers, testing & commissioning etc. as required as per technical specifications of different size armoured cable as per instruction of Engineer Incharge at Site. Total 2887803.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
NITEmergencyLightingatRlyStnMEAandDivyanganjWBPortion.pdf Tender Paper
ATTACHMENT
GCCApril-2022PDFwithallACS_compressed.pdf
ATTACHMENT
NITEmergencyLightingatRlyStnMEAandDivyanganjWBPortion.pdf
ATTACHMENT
Download all tender documents and submit your bid