Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 LAccepted-AOC | ₹11.8 L Quoted ₹12.5 L | L1 | Accepted-AOC Single Bidder, L1 |
| Sl No | Description | Qty | Unit | M K V Engineering L1 |
|---|---|---|---|---|
| 1.00Electrical Work | ||||
| 1.00 | OD4783/2024-2025:Supplying surface/suspended mounted smartbrite luminaire SM 270C LED 30S 6500 PSU WH Philips or equivalent | 15 | no | 4,800 ₹72,000 |
| 1.00 | OD4785/2024-2025:Supply and installation of ultra HD smart LED TV 55'' 3 Hdmi Ports For Seamless Connectivity With External Devices | 1 X Usb-A Usb Ports To Connect Hard Drives Or Other Usb Devices |Wi-Fi | Bluetooth | Anynet+ (Hdmi-Cec)| Ethernet (Lan) Port| Rf In (Terrestrial / Cable Input / Satellite Input).. Preferred make Samsung, LG, Sony etc.. | 1 | no | 75,000 ₹75,000 |
| 1.00 | OD4786/2024-2025:Supply, installation, testing and commissioning of 230V AC, 50HZ ,3KVA IGBT based PWM technology microprocessor controlled double conversion true Online UPS(96 V CD or above) capable for automatic changeover from mains to UPS on mains failure and vice versa with built in isolation transformer of make APC/NUMERIC/GE or equivalent suitable to work with 8Nos 12V,100 Ah,rated tubular type battery bank C10 for UPS application suitable for 3 hours backup on full load with suitable metallic battery mounting rack .Single phase Input Voltage Range 160-300 V AC, Output Frequency-50 ±. 01Hz,Output voltage Range :230VAC ± 1% ,Output power rating:2400W/3000VA,Interface port:RS232 and com port,Front panel Display: LCD ,input power factor:0.99, input Current THD <10% at full load,Output Voltage THD < 3%(Linear Load),THD <5%(Non-Linear load),Overall efficiency >=90%,Overload capacity :1min @ 111%-130% of rated load,10 minut @ 105%-110% of rated load,Load power factor: 0.8 lag or better,Load crest factor : 3:1, Noise level: <50 dBA at 1 meter, Continuous Operating Temperature: 0-40 °C,Constant current & constant Voltage with optional Temperature compensated battery charging. Standards: EMC- EN 62040-2, Safety- EN 62040-1, Performance- IEC 62040-3, Certifications: BIS,OSHAS,CE,PeP,RoHS, ISO 9001 & ISO 14001 ,Warranty :3 years on site warranty from the date of installation of ups and 4 year for battery complete. | 1 | no | 1,98,000 ₹2.0 L |
| 1.00 | OD4787/2024-2025:Supply, installation, testing and commissioning of 230V AC. 50HZ , 3.5 KVA inverter having digital frequency control circuit with on load automatic changeover from mains to inverter circuit on mains failure and vise versa on restoration of mains supply . The unit shall have an in-built battery charger with solar charging option of suitable capacity having automatic cut off circuit on battery attaining full charge . The unit should also have overload trip with audio visual indication & automatic reset on removal of overload, LED indication for Mains ON, charging ON, Overload Trip & inverter ON and Output ON/OFF switch on the front panel .Preferred make LUMINOUS / APC /MICROTEK. | 1 | no | 23,000 ₹23,000 |
| 1.00 | OD2745/2024-2025:Supply and installation of Inverter battery 12V 100 Ah tubular type conforming to ISO 9001:2008 and ISO 14001:2004 suitable for 3hours backup on full load .Preferred make of EXIDE / LUMINOUS / AMRON | 2 | no | 13,500 ₹27,000 |
| 1.01 | 90.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 2 | each | 5,500 ₹11,000 |
| 1.01 | OD2732/2024-2025:Supply of 3 core 1.5 sq mm copper conductor flat cable | 10 | metre | 90 ₹900 |
| 1.01 | 5.2:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal/ coke and salt) as required | 1 | set | 9,500 ₹9,500 |
| 1.01 | 5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. | 0.09 | metre | 1,800 ₹162 |
Tender Value
₹11.8 L
EMD Value
₹29,431
Closing Date
30 Jan 2026, 3:30 pmClosed
The Assistant Executive Engineer Electrical HEESD
O/o The chief Engineer, Harbour Engineering Electrical Sub Division, Kamaleswaram, TVPM
DEPOSIT-Fisheries- Aquaculture Training cum Awareness Centre Kasaba-Kasargod -Providing Additional facilities in Training Hall and Front office-Electrical Work-General Electrical Work
2026_HED_829865_1
HED/CEHED/TR/530/2024_6_1_1/1
Open Tender
Electrical Works
90 days
Kasaba-Kasargod
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹29,431
12 May 2026
22 Jan 2026
31 Jan 2026
22 Jan 2026
30 Jan 2026
22 Jan 2026
Electrical Work
OD4783/2024-2025:Supplying surface/suspended mounted smartbrite luminaire SM 270C LED 30S 6500 PSU WH Philips or equivalent
OD4785/2024-2025:Supply and installation of ultra HD smart LED TV 55'' 3 Hdmi Ports For Seamless Connectivity With External Devices | 1 X Usb-A Usb Ports To Connect Hard Drives Or Other Usb Devices |Wi-Fi | Bluetooth | Anynet+ (Hdmi-Cec)| Ethernet (Lan) Port| Rf In (Terrestrial / Cable Input / Satellite Input).. Preferred make Samsung, LG, Sony etc..
OD4786/2024-2025:Supply, installation, testing and commissioning of 230V AC, 50HZ ,3KVA IGBT based PWM technology microprocessor controlled double conversion true Online UPS(96 V CD or above) capable for automatic changeover from mains to UPS on mains failure and vice versa with built in isolation transformer of make APC/NUMERIC/GE or equivalent suitable to work with 8Nos 12V,100 Ah,rated tubular type battery bank C10 for UPS application suitable for 3 hours backup on full load with suitable metallic battery mounting rack .Single phase Input Voltage Range 160-300 V AC, Output Frequency-50 ±. 01Hz,Output voltage Range :230VAC ± 1% ,Output power rating:2400W/3000VA,Interface port:RS232 and com port,Front panel Display: LCD ,input power factor:0.99, input Current THD <10% at full load,Output Voltage THD < 3%(Linear Load),THD <5%(Non-Linear load),Overall efficiency >=90%,Overload capacity :1min @ 111%-130% of rated load,10 minut @ 105%-110% of rated load,Load power factor: 0.8 lag or better,Load crest factor : 3:1, Noise level: <50 dBA at 1 meter, Continuous Operating Temperature: 0-40 °C,Constant current & constant Voltage with optional Temperature compensated battery charging. Standards: EMC- EN 62040-2, Safety- EN 62040-1, Performance- IEC 62040-3, Certifications: BIS,OSHAS,CE,PeP,RoHS, ISO 9001 & ISO 14001 ,Warranty :3 years on site warranty from the date of installation of ups and 4 year for battery complete.
OD4787/2024-2025:Supply, installation, testing and commissioning of 230V AC. 50HZ , 3.5 KVA inverter having digital frequency control circuit with on load automatic changeover from mains to inverter circuit on mains failure and vise versa on restoration of mains supply . The unit shall have an in-built battery charger with solar charging option of suitable capacity having automatic cut off circuit on battery attaining full charge . The unit should also have overload trip with audio visual indication & automatic reset on removal of overload, LED indication for Mains ON, charging ON, Overload Trip & inverter ON and Output ON/OFF switch on the front panel .Preferred make LUMINOUS / APC /MICROTEK.
OD2745/2024-2025:Supply and installation of Inverter battery 12V 100 Ah tubular type conforming to ISO 9001:2008 and ISO 14001:2004 suitable for 3hours backup on full load .Preferred make of EXIDE / LUMINOUS / AMRON
90.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD2732/2024-2025:Supply of 3 core 1.5 sq mm copper conductor flat cable
5.2:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal/ coke and salt) as required
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
OD2738/2024-2025:Engaging labourers for dismantling the existing DB, electrical fittings, accessories etc., keeping the same safely and restoring the surface neatly. as per the instruction form the departmental officers at site . Beldar/coolie
OD2739/2024-2025:Engaging labourers for dismantling the existing DB, electrical fittings, accessories etc., keeping the same safely and restoring the surface neatly. as per the instruction form the departmental officers at site. Wireman
90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
OD2740/2024-2025:Supplying 16 W LED Tube with box type fixtures Essential LED tube 1200 mm 16W 840 T8 API Philips or equivalent
1.41:Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
OD2741/2024-2025:Supply and fix LED Bulk Head fitting 10W with Aluminium die-cast housing and polycarbonate optic materials including connection etc as required. The luminaire shall have IP66 protection, luminous flux 1100 lm, luminous efficiency 110 lumens/watt, cool daylight colour and 6500k colour temperature PHILIPS Endura LED Bulk Head model WT202W LED10S CW PSU S3 PC or equivalent
1.34:Supplying and fixing brass batten/ angle holder including connection etc. as required.
OD2742/2024-2025:Supply and fixing 7/9 W LED ,BC, lamp OSRAM or equivalent
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
OD4784/2024-2025:Scrapping and cleaning the surface and painting two coats of best quality synthetic enamel paint of approved color over two coat of epoxy based industrial primer on electrical panel including all cost.
OD4788/2024-2025:Supplying Round surface mounted PHILIPS ESSENTIAL LED plus 15 W or equivalent
1.38:Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
OD4791/2024-2025:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
OD4792/2024-2025:RJ 11 telephone jack
OD4793/2024-2025:Supply of Cat 6,1 meter patch cord
OD4794/2024-2025:Identifying cables, supply and crimping RJ 45/RJ 11 cable jack on the cable end and giving connection
OD4795/2024-2025:RJ 45 Frame
OD4796/2024-2025:CAT 6 RJ 45 computer data socket
OD4798/2024-2025:Supplying 16mm dia LED type Phase indication lamp(Red , Yellow & Green)
OD4799/2024-2025:Supply and installation of Panel surface mounting 96 sqmm LED Multi function meter to read V,A, kVA, kVAr, PPF and frequency suitbale for 415 volts, 50 Hz
OD4808/2024-2025:Supply and drawn 10 HDMI cable to connect NVR to LED TV.
OD68/2025-2026:Installation Testing and commissioning of 1 to 2 Tonne departmentallly supplied split type air conditioning unit in suitable location
OD69/2025-2026:Supply, Testing and commissioning of Wall hanging type Voltage stabilizer of Single phase 230V, ac, 50Hz,4000 VA suitable for 170 to 260V input voltage range preferred make of V- GUARD/ MICROTEK for 2 T Inverter AC
OD70/2025-2026:Supply of 2 Tonne, 230V, ac, 50Hz single phase 3 star rated full copper highwall split Inverter Air conditioner. Preffered make of (Voltas/Bluestar) with cordless remote
OD87/2025-2026:Supply of Single channel VHF wireless microphone
OD88/2025-2026:Supply of best quality mic cable
OD89/2025-2026:Supply of unidirectional dynamic wired mic. Preffered: AHUJA AUD 100 XLR
OD90/2025-2026:Supply and installation of 12U/600 Rack with Bracket wall mounting type Rack with 1Ph, 230V, 8A, 2U standard rack mount power distribution unit with 6 X 5A plug socket, Cantilever Shelf(3Nos), cable alley and fan Preferred make:Netrack or equivalent
OD103/2025-2026:Supply of XLR male connector
OD102/2025-2026:Supply of 6.35mm Phonoconnector
OD91/2025-2026:Supply of DPR125W Mixer recordable Amplifier with five Mic inputs, built-in MP3 recorder player and USB with large display, SD/MMC card reader, LCD supplied and separate remote
OD92/2025-2026:Supply of gooseneck microphone PGM 625 with microphone stand PGB 10 and stand APS 302Phantom power of following specifications, Frequency response: 50-16,000 Hz, Sensitivity-45 DB plus or minus 3 DB Impedance: 2000 ohm plus or minus thirty percent, Power required: 9-52 V Phantom supply
OD93/2025-2026:Supply of fully automatic servo motor type AC voltage regulator capacity 2KVA specially designed for audio equipment having over votage and under votage correction, short circuited protected, no waveform distortion, low noise operation, high overload capability Fail Safe Circuit Protection: Cuts off the power to connected equipment in case of component failure, Time Delay: 30 seconds maximum, Input Voltage Range: 180V to 265V,
OD95/2025-2026:Supply and installation of universal ceiling mounting clamp for projector including 10 m HDMI, 10m VGA and 10 m Power cable
OD96/2025-2026:Supply and installation of Projector maximum brightness 3300 Im Controller Portable XGA 3LCD including Remote Control, Power Cord, AV Cable . Epson EB-E01 or equvalent.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1393809.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_1393809.xls
BOQ • 0.34 MB
viewsbd.pdf
Tender Documents • 1.67 MB
Download all tender documents and submit your bid