| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹48.3 L+₹8.5 L (21.2%)Rejected-Technical 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | L2 | Rejected-Technical Not enlisted in appropriate category | |
| 3 | Rejected-Technical | - | Rejected-Technical Not enlisted in appropriate category | |
| 4 | Rejected-Technical | - | Rejected-Technical Not enlisted in appropriate category | |
| 5 | Rejected-Technical GALI NO 4 GAUSHALA ROAD VIKASH NAGAR RAMGARH CANTT RAMGARH JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | - | Rejected-Technical Not enlisted in appropriate category |
Tender Value
Refer Docs
EMD Value
₹78,500
Closing Date
24 Nov 2020, 6:00 pmClosed
CWE Ranchi
HQ CWE RANCHI MES DIPATOLI CANTT PO RMCH RANCHI - 834009
SPECIAL REPAIR TO 1600 KVA TRANSFORMER AGAINST BER AT 33 KVA MRS AND PROVN OF 100 KVA TRANSFORMER, ELECTRIC POLE ACSR CONDUCTOR FOR IHC JCOS ORS MD ACCN AT PRC UNDER GE RAMGARH CANTT
2020_MES_367689_4
80599/1307/E8
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
Ramgarh Cantt
Class D category b(iii)
7 documents required · 7 mandatory
₹500
Yes
GE Ramgarh
₹78,500
Yes
8 Jan 2021
2 Nov 2020
26 Nov 2020
2 Nov 2020
24 Nov 2020
10 Nov 2020
Amount
Supply, installattion, testing & commissioning of outdoor type step down 1600 KVA transformer complete with standard fittings, HT 33/11KV ON load tap changing system , HT 3 Phase, 1600 KVA capacity, Boltless core design, Class A insulation copper wound oil immersed, naturally cooled, oil natural -air natural with external cooling tubes delta connected on primary side (HV) and at ON load tap changing system on HT side to vary secondary voltage (HV) in accordance with vector group DYN- 11 with neutral brought out on secondary side (HV side) and having changing tap arrangements up to +5 % to -15% @ 1.25 % (OLTC) on HV side to be changed by means of ON load tap changer gear .the maximum temperature rise should not exceed 50/55 deg .C in HV winding when measured by resistance method after continuous full load run on an ambient temp 40 degree Celsius transformer shall be confirming to IS:2026 as amended up to date and shall comprises of following :- .
Three Nos porcelain bushing suitable for 33 KV on HV side, complete with copper rods, nuts and washers.
Four Nos porcelain bushing suitable for 11 KV on LV side, complete with copper rods, nuts and washers with cable end box.
Monogram plate.
Detachable cooling radiators with drain & air release plug, isolating valves and lifting lug at top & bottom.
Oil conservator with filter and drain plug.
Prismatic/transparent oil gauge.
De-hydrating breather with first fill of dehydrating agent (silica gel).
Thermometer pocket.
Air release plug.
Inspection cover
Lifting lugs for complete transformer
Top cover lifting lugs
Jacking lugs
Top filter valve
Instruction plate
Drain cum bottom filter valves
Earthing terminal and stud
On load tap changer with locking arrangement.
Rating and Diagram plate
Buchholz relay with alarm & trip contacts.
Bi directional roller wheel -04 Nos.
Marshalling box for termination of all alarm & trip controls of the transformer.
WTI (Winding temperature indicator) with alarm & trip contact
Oil surge relay.
Shut off valve for buchholz relay.
OTI (Oil temperature indicator) dial type of 150 mm with alarm and trip contact capillary type.
Two earthing terminals on tank cover to facilitate fixing of 50x6 mm galvanised iron earth strip for earthing of body.
First filling of new and unused transformer oil, IS-335 marked (Make: HP / Savita/Apar/Power Link filtered and tested upto 60 KV dielectric strength of 2.5 mm air gap between testing electrodes.
Note: Rate include following (i) cost of installation in existing plinth, connection with existing incomming and out going cable connections , control cable to circuit breakers , setting of relays as per New transformer rating and earthing connections to existing earth test points. Cost of setting of all protective relays in existing substation as per New transformer rating is deemed to be included in quoted rate.
(ii) Contractor shall submit the Manufacture Test certificate, PV (Factory Test sheets) before commencement of work and ensure the installation is as per OEM specifications and submit the Test results after instllation complete all specified and directed by Engineer in Charge and scope of work include factory Inspection by the rep of GE as nominated by him and Testing of SEI, from HQ Central command and cost thereof shall deemed to be included in the quoted rates. (iii) Any other items which are not mentioned above but are essential for smooth functioning of transformer shall also deemed to be included in the quoted rates. Make: ABB / Siemens/ ITE Gurgaon / Schneider / Crompton Greaves / GE / Indotech.
Supply, installation, testing and commissioning energy efficient transformer suitable for 100 kVA step down, outdoor, plateform mounted double wound copper, 3 phase ,50 cycles (50 Hz) AC, oil immersed, natural air cooled with external cooling tubes having no load voltage ratio 11000/433 volts ( corresponding to principal tapping) winding delta connected on primary side (HV) and star connected on secondary side (LV side) in accordance with vector symbol Dyn-11 (vector group - 11) with neutral brought out on LV side for earthing and having tapping on HV side for constant out put so as to alter/ vary secondary voltage by + 5 % to + 10 % in steps of 2.5 % to be changed by means of manually operated "off load" taps changing gear. The limit of temperature rise after continous full load run as specified in IS-2026 shall be suitably adjusted to suit the maximum ambient temperature of 55 Degree Centigrade in HV/LV windings and 40 Degree centigrade in oil as prevalling at site. The transformer shall be complete with the following fittings and accessories:-
Oil conservator tank with filling holes and cap, filter type drain valve and oil level gauge
Silicagel breather with connecting pipe, first fill of dehydrating agent and oil level scale/ gauge.
Shut off valve between the conservator and main tank.
Provn of 02 danger Notice plate 350x200x1.6mm vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with and including MS Clamps bolts and nuts.
Air release valve plug
One cable box on LV side ( Secondary) consisting of 04 Nos porcelain bushings with nuts, washers & bushing rods with 01 cable gland suitable for reception of taking out one 3 1/2 core, 95 Sqmm , LT 1100 Volts grade cable including gland joints complete all as specified.
01 No. 100 mm dial type thermometer vapour pressure type having range 0-120 degree centigrade with max temp indicator and resetting device inc max reading pointert washers etc.
Thermometer pocket on tank cover
04 Nos Plain Solid CI detachable rollers
Two Nos Earting terminals on tank cover to facilitate GI earth strip
Rating plate and terminal marking plate.
Extra bushing for neutral outside the cable box brought out on LV side.
First filling of oil conforming to IS and tested upto 40 KV dielectric strength
Lifting lugs
Oil drain valve with plug
3 Nos Poreclain HV bushing with arching horns on HV side suitable for 11 KV complete bushing rods , nuts and washers
Explosive vent
Note :- Any other items which are not mentioned above but are essential for smooth functioning of transformer shall also deemed to be included in the quoted rates.
Excavation, in trenches n.exc 1.5 m wide & n.exc 1.5 m in depth for laying cable/pipes etc and getting out in hard/dense soil, complete all as specified and as directed.
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick, complete all as specified and as directed.
Removing excavated materials (soil) to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the staring point, complete all as specified and as directed.
M & L for reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and as directed.
M & L reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx l80mm x 40mm complete all as specified and as directed.
M&L Sand filling in cable trenches for cable protection with clean dry sand unwashed incl gently punning in a layer of 15 Cm and 8 Cm (total 23 CM) in thickness all across the laid portion of LT Cable in trenches complete all as specified and directed. Note :- Punned thickness shall only be considered for payment
Supplying, laying or fixing, jointing and testing 11 KV (E) system , Crossed linked polyethylene ( XLPE) insulated, screened , PVC bedded, galvanised steel strip or wire armoured, electric power cables( heavy duty) ISI-7098 Mark, with aluminium conductor multi stranded of cross sectional area 95 sqmm 3 core, laid in trenches/ laid under floor or fixed naked with walls / on poles etc. complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks and pipe shall be measured and paid separately under appropriate items
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, two or more core, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of following size / cross sectional area , laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. including necessary Clamps, nuts , bolts, washers etc complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks and pipe shall be measured and paid separately under appropriate items
120 sqmm 3 ½ core
25 sqmm 4 core
Supply and fix cable end jointing kit for 11 KV grade cable for outdoor termination cold shrink push on type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core x 95 sqmm complete all as specified.
Supply and fix, danger notice plate of size 25 cm x 20 cm abd 1.6 mm thick mild steel sheet viteous enameled white, with letter, figures and conventional skull and bones in singal red colour and fixed with M.S clamps bolts and nuts of approved size for HT complete all as specified and as directed.
M & L for transformer platform for the size 3x3x1.5 after consisting of the following sequence.or as OEM instructions-(a) excn in trenches in any type of soil.(b) Removing of surplus materials.(c) Returning filling.(d) 150 mm thick PCC 1:4:8 as in mass concrete in foundation extending 150mm on both sides of wall.(e) 350mm thick of brick masnory built in CM 1:6, 450mm below GL and 945 mm above GL duly plastered in CM 1:4 on Exposed faces & Flush in same mortar as the work proceeds on faces in contact with soil(f) Rendering with finished surface neat cement slurry.(g) floor of 50mm hardcore over approved earth filling complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep, getting out watering and removing surplus soil to a distance n.exc 50m and making good surface complete all as specified.
M & L for loose filling with aggregate of size 40 mm graded of 20 cm thickness around at 4 pole/ 2 pole HT structure complete all as specified and as directed
M& L for Brickwork with subclass ‘B’ bricks, straight or curved on plan , exc 6 m mean radius built in CM 1:6 complete all as specified and as directed.
M & L for Rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed
Excavation in post holes (or similar holes) each not exc. 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exc. 25 cm, watering and removing surplus soil to a distance not exc. 50 metre and making good surfaces in soft / loose soil, complete all as specified and as directed.
M&L for plain Cement Concrete 1:3:6, Type C-2 of grade using 40mm graded stone aggregate in foundations, filling and mass concrete, etc. for embedding fencing posts, complete all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provission of binding wire complete all as specified and as directed.
Supply only for Chain link MS galvanisd fencing, any size or type complete all as specified and as directed.
M& L for Mild steel gate with framed work such as grills, gratings, etc. with ends of bars shouldered and/ or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work, portions framed and hung gates, including pintle hinges, stops, hand-made sliding bolts etc as conforming to Fe.290, Gde-E-165 complete all as specified and as directed.
Material & labour for preparation of new steel surfaces of any description over 10 cm width or girth not other wise described and applying two coats of synthatic enamel paint over one coat of red oxide primer complete all as specified and directed.
Earthing complete with galvanized iron earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge earth plate not less than 1.5m below GL using galvanised iron strip 32×6mm as earthing lead to earth plate electrode by means of nuts, bolts and washers made of galvanized iron or steel earth wire protected by 15 mm bore light grade GI pipe and connected for body earthing of feeder pillar box all as specified with & including PCC (1:3:6) type C1 pit and precast RCC (1:2:4) type B1, cover slab of size 300x300x50mm, with handle GI funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal and salt in alternate layer including necessary earth work on any type of soil and removal etc, complete all as specified and shown in electrical plate No 3 of SSR Part I and as directed. Note:- Earth wire up to 7.5 meter connected to earth point shall be deemed to be included in unit rate.
Supplying, installing, fixing, commissioning and testing of Air break gang operated triple pole switch a out door type of capacity 200 Amps AC mechanically operated mounted on polymer based insulators and steel frame with operating mechanism worked from ground level and polymer based Drop-out fuse set (set of 3 nos), mounted on insulators with steel frame with Expulsion fuse carriers and fuse element Upto 10 Amp complete with locking arrangements incl pad locks with key including connection to existing bus bar existing 2/4 pole structure with ACSR conductor of suitable rating complete suitable for 11KV, HT, 50 Hz complete all as specified and directed.
Supply, install, testing & commissioning LT panel board out door type CPRI approved ,CRCA sheet 3.15 mm thick suitable for outdoor powder coated , factory made weather and vermin proof, with cable entry from bottom 400 Amps aluminium bus bar conforming to IP- 65, as per CPRI approved in accordance with and including the following equipments including earthling stids and necessary earth work excavation and PCC (1:2:4) type B1 foundation complete all as directed and specified:- Incoming (i) MCCB FP 200 A, 16 KA-01 Nos, ICS 100 % of ICU or equivalent (as incoming), (ii) Digital volt, meter , 0-500 Volt -01 No (iii) Digital Ammeter , 0- 200 Amp -01 No (iv) 'RYB' indicator LED lamps- 03 Nos Out going (i) MCCB FP 160A, 10 KA-02 Nos (ii) Space for provision of 02 Nos MCCB 63 Amp 4 pole
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with earthing strip of size 32 x 6 mm thick all as specified and directed.
Raj Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .