| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC H NO 982 SECTOR 16 STREET NO 17 SARASWATI VIHAR DERABASSI DISTT SAS NAGAR PB 140507 | S A S NAGAR | PUNJAB | 140507 | L1 | Accepted-AOC L1 QUOTED | |
| 2 | L2₹25.2 L+₹6.3 L (33.3%)Rejected-AOC | L2 | Rejected-AOC L2 QUOTED | |
| 3 | L3₹31.0 L+₹12.1 L (63.9%)Rejected-AOC 368 PHASE 4 SAS NAGAR MOHALI 160059 PB | MOHALI | SAS NAGAR | PUNJAB | 160059 | L3 | Rejected-AOC L3 QUOTED | |
| 4 | L4₹36.1 L+₹17.1 L (90.5%)Rejected-AOC P O GARNAI VILLAGE LADHYALA MALHAR TEHSIL DISTT UDHAMPUR J K 182121 | UDHAMPUR | JAMMU AND KASHMIR | 182121 | L4 | Rejected-AOC L4 QUOTED |
| Sl No | Description | Qty | Unit | SUDESH ENTREPRISES L2 | jmv engineers L1 | m/s sushila devi L4 | Baba Engineers and Contractors L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Rendering 15 mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement in and including taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, and removal of rubbish outside MoD land for building upto 12.00m high, complete all as specified and directed by Engineer-in-Charge.
Note: No extra payment made to contractor for work in small patches as required at site/as directed. | 1,000 | SQUARE METRE | 100 ₹1,00,000 Lowest | 300 ₹3,00,000 | 230 ₹2,30,000 | 200 ₹2,00,000 |
| 2.00 | Two component elastomeric acrylic polymer modified cementitious waterproofing coating on brick level, Damp Proof Coating, having 100% elongation as per ASTM D412, resisting 5 bars hydrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging up to 1.2mm as per ASTM 4548.5. The coating shall have food grade certificate from laboratories like CFTRI. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing, etc. After coating will sprinkle sand on the coating then apply plaster on the coating, which is in contractor scope complete as per manufacturer specifications for building upto 12.00m high, complete all as specified and directed by Engineer-in-Charge.
Note: No extra payment made to contractor for work in small patches as required at site/as directed. | 620 | SQUARE METRE | 250 ₹1,55,000 Lowest | 350 ₹2,17,000 | 450 ₹2,79,000 | 1,300 ₹8,06,000 |
| 3.00 | Rendering 15 mm thick on brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement in and including taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, and removal of rubbish outside MoD land for building upto 15.00m high, complete all as specified and directed by Engineer-in-Charge.
Note: No extra payment made to contractor for work in small patches as required at site/as directed. | 300 | SQUARE METRE | 100 ₹30,000 Lowest | 200 ₹60,000 | 230 ₹69,000 | 225 ₹67,500 |
| 4.00 | Rendering 10 mm thick in cement mortar (1:3), as on concrete surfaces (such as top & bottom of chajjas, beams, balcony ceiling ,roof slab ceiling etc.) finished the surfcae even and smooth without using extra cement in and including taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, and removing of rubbish outside MoD land for building upto 12.00m high, complete all as specified and directed by Engineer-in-Charge.
Notes: (i) No extra payment made to contractor for work in small patches as required at site/as directed.
(ii) Serialwise allotment of space will be provided to the contractor for execution of work. | 100 | SQUARE METRE | 100 ₹10,000 Lowest | 200 ₹20,000 | 500 ₹50,000 | 200 ₹20,000 |
| 5.00 | Preparing Existing Concrete Surfaces and making it clean, even and sound. Cutting and opening cracks to a depth of 10x10 mm V or U Shape by mechanical means. Cleaning all the dirt and loose particles by air pressure and wetting crack to attain SSD condition, filling the crack using Repair Polymer modified cement mortar and using Repair Polymer over pipe and Internal side of concrete followed by filing high strength non shrink grout for a gap of up to 20mm (between pipe and concrete) before treating the surface with Waterproofing layer. Supplying and applying fiber reinforced elastomeric liquid waterproofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with Sun Reflectivity Index (SRI) of 105 on top of roof in four coats @ 2 Kg/sqmt to be reinforced, having minimum elongation of 350%, tensile strength 2.9Mpa and shall have crack bridging ability of up to 2.5mm and shall resist 10bars of hydrostatic pressure, reduces surfaces temperature up to 10 degree Celsius also IGBC certified (Indian Green Building Council) Certificate will be provided by company. The system consists of self-priming with 33% water dilution followed by two undiluted coats of Damp Proof, the fiber mesh of 40 to 50 GSM must be sandwich between 1st and 2nd coat of Damp Proof. (dry film thickness of complete application/system not less than 500 microns).
for building upto 12.00m high, complete all as specified and directed by Engineer-in-Charge.
Note: No extra payment made to contractor for work in small patches as required at site/as directed. | 150 | SQUARE METRE | 800 ₹1,20,000 | 520 ₹78,000 | 500 ₹75,000 Lowest | 1,400 ₹2,10,000 |
| 6.00 | One coat of primer @ 1 ltr per 100 sqft diluted with 100 % by water to be applied using an airless spray machine of with a flow rate of 2L per minute having a pressure of 3300 PSI. Allow 4-6 hrs to dry the surface for painting of subsequent coats, After priming two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additives, with heat Reflectant property which can reduce the painted surface temp. by 5 degree and gives excellent protection against UV attack with VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1L / 60 sqft diluted with water as per manufacturer instructions applied over priming coat with airless spray machine of paint application with a flow rate of 2L per minute having a pressure of 3300 PSI. Allow 4-6 hrs to dry the surface in both the coats of paint for building upto 12.00m high, complete all as specified and directed by Engineer-in-Charge.
Note: Colours/Shade shall be approved by GE. | 1,870 | SQUARE METRE | 150 ₹2,80,500 | 70 ₹1,30,900 Lowest | 200 ₹3,74,000 | 80 ₹1,49,600 |
| 7.00 | Putty of average thickness 1 mm over the plastered @ 1kg per sq. mtr. after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust by skilled labour. Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with a capacity of mixing 40kg putty in single go. The putty mixer should have variable speed functioning for preparation of smooth and lump free putty. M&L for one coat of primer @ 1 ltr per 200 sqft diluted with 100% by water to be applied using an airless spray machine of with a flow rate of 2L per minute having a pressure of 3300 PSI. Allow 4-6 hrs to dry the surface for painting of subsequent coats., M&L for applying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 100 ft. The spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard-to-reach areas and penetration of distemper on the surface , complete all as specified and directed by Engineer-in-Charge.
Notes: (i) Colours/Shade shall be approved by GE.
(ii) Serialwise allotment of space will be provided to the contractor for execution of work. | 300 | SQUARE METRE | 190 ₹57,000 | 100 ₹30,000 Lowest | 200 ₹60,000 | 120 ₹36,000 |
| 8.00 | Complete removal of existing treatment by scrapping and sanding with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of diameter of 7"/9" using a 80 grit sanding paper to make the surface free from dust, loose paint etc. by skilled labour complete all as directed, after sanding, one coat of primer @ 1 ltr per 100 sqft. diluted with 100 % by water to be applied using an airless spray machine with a flow rate of 2L per minute having a pressure of 3300 PSI. Allow 4-6 hrs to dry the surface for painting of subsequent coats.M&L for two coat water based acrylic smooth exterior emulsion of approved colour with silicon additives, with heat Reflectant property which can reduce the painted surface temp. by 5 degree and gives excellent protection against UV attack with VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1L / 60 sqft diluted with water as per manufacturer instructions applied over priming coat with airless spray machine of paint application with a flow rate of 2L per minute having a pressure of 3300 PSI. Allow 4-6 hrs to dry the surface in both the coats of paint for building upto 12.00m high, complete all as specified and directed by Engineer-in-Charge.
Note: Colours/Shade shall be approved by GE. | 1,780 | SQUARE METRE | 190 ₹3,38,200 | 100 ₹1,78,000 Lowest | 200 ₹3,56,000 | 100 ₹1,78,000 Lowest |
| 9.00 | Complete removal of existing treatment by scrapping and sanding with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of diameter of 7"/9" using a 80 grit sanding paper to make the surface free from dust, loose paint etc. by skilled labour complete all as directed., M&L for touch up putty application wherever required over the old painted wall/ceiling @ 1kg per sq. mtr. Mix the putty powder by adding water as per manufacturer instructions and mix it withputty mixer with a capacity of mixing 40kg putty in single go. The putty mixer should have variable speed functioning for preparation of smooth and lump free putty. M&L for one coat of primer @ 1 ltr per 200 sqft diluted with 100% by water to be applied using an airless spray machine of with a flow rate of 2L per minute having a pressure of 3300 PSI. Allow 4-6 hrs to dry the surface for painting of subsequent coats, M&L for applying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 100 ft. The spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard-toreach areas and penetration of distemper on the surface , complete all as specified and directed by Engineer-in-Charge.
Notes: (i) Colours/Shade shall be approved by GE.
(ii) Serialwise allotment of space will be provided to the contractor for execution of work. | 6,911 | SQUARE METRE | 160 ₹11,05,760 | 70 ₹4,83,770 Lowest | 219 ₹15,13,509 | 100 ₹6,91,100 |
| 10.00 | Preparation of old painted steel or Iron surfaces of any description over 10cm width or grith not otherwise described and applying one coat synthetic enamel paint for building upto 15.00m high, complete all as specified and directed by Engineer-in-Charge.
Notes: (i) Colours/ Shade shall be approved by GE
(ii) Serialwise allotment of space will be provided to the contractor for execution of work. | 400 | SQUARE METRE | 120 ₹48,000 | 70 ₹28,000 | 60 ₹24,000 | 35 ₹14,000 Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
6 Jan 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Chandigarh
GE (AF) Chandigarh, Air Force Station Chandigarh-160003
SMART PERIODICAL SERVICES TO OFFICE BUILDINGS IN DOMESTIC AREA AND IN BLOCKS OF BRAR ENCLAVE CHANDIGARH UNDER GE (AF) CHANDIGARH.
2025_MES_744756_1
GE (AF)/CHD/T-54/2025-26
Open Tender
Civil Works
Item Rate
183 days
Chandigarh
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE (AF) Chandigarh
₹90,000
Yes
17 Feb 2026
16 Dec 2025
13 Jan 2026
16 Dec 2025
6 Jan 2026
30 Dec 2025
16 Dec 2025 - 23 Dec 2025
Rendering 15 mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement in and including taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, and removal of rubbish outside MoD land for building upto 12.00m high, complete all as specified and directed by Engineer-in-Charge. Note: No extra payment made to contractor for work in small patches as required at site/as directed.
Two component elastomeric acrylic polymer modified cementitious waterproofing coating on brick level, Damp Proof Coating, having 100% elongation as per ASTM D412, resisting 5 bars hydrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging up to 1.2mm as per ASTM 4548.5. The coating shall have food grade certificate from laboratories like CFTRI. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing, etc. After coating will sprinkle sand on the coating then apply plaster on the coating, which is in contractor scope complete as per manufacturer specifications for building upto 12.00m high, complete all as specified and directed by Engineer-in-Charge. Note: No extra payment made to contractor for work in small patches as required at site/as directed.
Rendering 15 mm thick on brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement in and including taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, and removal of rubbish outside MoD land for building upto 15.00m high, complete all as specified and directed by Engineer-in-Charge. Note: No extra payment made to contractor for work in small patches as required at site/as directed.
Rendering 10 mm thick in cement mortar (1:3), as on concrete surfaces (such as top & bottom of chajjas, beams, balcony ceiling ,roof slab ceiling etc.) finished the surfcae even and smooth without using extra cement in and including taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, and removing of rubbish outside MoD land for building upto 12.00m high, complete all as specified and directed by Engineer-in-Charge. Notes: (i) No extra payment made to contractor for work in small patches as required at site/as directed. (ii) Serialwise allotment of space will be provided to the contractor for execution of work.
Preparing Existing Concrete Surfaces and making it clean, even and sound. Cutting and opening cracks to a depth of 10x10 mm V or U Shape by mechanical means. Cleaning all the dirt and loose particles by air pressure and wetting crack to attain SSD condition, filling the crack using Repair Polymer modified cement mortar and using Repair Polymer over pipe and Internal side of concrete followed by filing high strength non shrink grout for a gap of up to 20mm (between pipe and concrete) before treating the surface with Waterproofing layer. Supplying and applying fiber reinforced elastomeric liquid waterproofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with Sun Reflectivity Index (SRI) of 105 on top of roof in four coats @ 2 Kg/sqmt to be reinforced, having minimum elongation of 350%, tensile strength 2.9Mpa and shall have crack bridging ability of up to 2.5mm and shall resist 10bars of hydrostatic pressure, reduces surfaces temperature up to 10 degree Celsius also IGBC certified (Indian Green Building Council) Certificate will be provided by company. The system consists of self-priming with 33% water dilution followed by two undiluted coats of Damp Proof, the fiber mesh of 40 to 50 GSM must be sandwich between 1st and 2nd coat of Damp Proof. (dry film thickness of complete application/system not less than 500 microns). for building upto 12.00m high, complete all as specified and directed by Engineer-in-Charge. Note: No extra payment made to contractor for work in small patches as required at site/as directed.
One coat of primer @ 1 ltr per 100 sqft diluted with 100 % by water to be applied using an airless spray machine of with a flow rate of 2L per minute having a pressure of 3300 PSI. Allow 4-6 hrs to dry the surface for painting of subsequent coats, After priming two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additives, with heat Reflectant property which can reduce the painted surface temp. by 5 degree and gives excellent protection against UV attack with VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1L / 60 sqft diluted with water as per manufacturer instructions applied over priming coat with airless spray machine of paint application with a flow rate of 2L per minute having a pressure of 3300 PSI. Allow 4-6 hrs to dry the surface in both the coats of paint for building upto 12.00m high, complete all as specified and directed by Engineer-in-Charge. Note: Colours/Shade shall be approved by GE.
Putty of average thickness 1 mm over the plastered @ 1kg per sq. mtr. after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust by skilled labour. Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with a capacity of mixing 40kg putty in single go. The putty mixer should have variable speed functioning for preparation of smooth and lump free putty. M&L for one coat of primer @ 1 ltr per 200 sqft diluted with 100% by water to be applied using an airless spray machine of with a flow rate of 2L per minute having a pressure of 3300 PSI. Allow 4-6 hrs to dry the surface for painting of subsequent coats., M&L for applying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 100 ft. The spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard-to-reach areas and penetration of distemper on the surface , complete all as specified and directed by Engineer-in-Charge. Notes: (i) Colours/Shade shall be approved by GE. (ii) Serialwise allotment of space will be provided to the contractor for execution of work.
Complete removal of existing treatment by scrapping and sanding with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of diameter of 7"/9" using a 80 grit sanding paper to make the surface free from dust, loose paint etc. by skilled labour complete all as directed, after sanding, one coat of primer @ 1 ltr per 100 sqft. diluted with 100 % by water to be applied using an airless spray machine with a flow rate of 2L per minute having a pressure of 3300 PSI. Allow 4-6 hrs to dry the surface for painting of subsequent coats.M&L for two coat water based acrylic smooth exterior emulsion of approved colour with silicon additives, with heat Reflectant property which can reduce the painted surface temp. by 5 degree and gives excellent protection against UV attack with VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1L / 60 sqft diluted with water as per manufacturer instructions applied over priming coat with airless spray machine of paint application with a flow rate of 2L per minute having a pressure of 3300 PSI. Allow 4-6 hrs to dry the surface in both the coats of paint for building upto 12.00m high, complete all as specified and directed by Engineer-in-Charge. Note: Colours/Shade shall be approved by GE.
Complete removal of existing treatment by scrapping and sanding with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of diameter of 7"/9" using a 80 grit sanding paper to make the surface free from dust, loose paint etc. by skilled labour complete all as directed., M&L for touch up putty application wherever required over the old painted wall/ceiling @ 1kg per sq. mtr. Mix the putty powder by adding water as per manufacturer instructions and mix it withputty mixer with a capacity of mixing 40kg putty in single go. The putty mixer should have variable speed functioning for preparation of smooth and lump free putty. M&L for one coat of primer @ 1 ltr per 200 sqft diluted with 100% by water to be applied using an airless spray machine of with a flow rate of 2L per minute having a pressure of 3300 PSI. Allow 4-6 hrs to dry the surface for painting of subsequent coats, M&L for applying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 100 ft. The spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard-toreach areas and penetration of distemper on the surface , complete all as specified and directed by Engineer-in-Charge. Notes: (i) Colours/Shade shall be approved by GE. (ii) Serialwise allotment of space will be provided to the contractor for execution of work.
Preparation of old painted steel or Iron surfaces of any description over 10cm width or grith not otherwise described and applying one coat synthetic enamel paint for building upto 15.00m high, complete all as specified and directed by Engineer-in-Charge. Notes: (i) Colours/ Shade shall be approved by GE (ii) Serialwise allotment of space will be provided to the contractor for execution of work.
Preparation of old painted wooden surfaces of any description over 10cm width or grith not otherwise described and applying one coat synthetic enamel paint , complete all as specified and directed by Engineer-in-Charge. Notes: (i) Colours/ Shade shall be approved by GE (ii) Serialwise allotment of space will be provided to the contractor for execution of work.
Notes for item No. 1 to 11 : (i).Quoted rate shall deemed to be includedthe cost for necessary scaffolding , ladders, cradles etc,for the height of building mentioned in respective item of this BOQ including removing nails, making good holes, cracks etc removing furnitures, cub boards, washing floors, floor and wall tiles,cleaning glasses, joinerys, electric fittings, wiring, conduits etc of drops, splashes and living premises clean and tidy upto entire satisfaction of Engineer-in-Charge, (ii) All safety measures for the safety of workers shall be ensured by contractor before execution of work. Insurance of workers shall be got done by contractor before execution of the work and the cost for the same shall be deemed to be included in rate quoted by contractor.
Note for item no 5 to 9 : The work for periodical services shall include the following and the rates quoted by the bidders shall deemed to be included these aspects in his quoted rate for respective item :- (a) The work pertaining to periodical services shall be executed by the contractor as per MoU from authorised applicator through manufacturer of the materials like Exterior Emulsion paint, putty etc after approv
Rolled Sections Fe 410-W (Gde-E-250)quality-A as in framing for cladding, glazing and the likes fixed with angle cleats and connecting plates, etc, in and including dismantling structural steel frame work, complete all as specified and directed by Engineer-in-Charge.
Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc., complete all as specified and directed by Engineer-in-Charge.
Preparation of new or previously untreated steel surfaces of any description , not otherwise described over 10 cm width or girth and applying two coats of synthetic enamells paint over one coat of red oxide primer,complete all as specified and directed by the Engineer in Charge. Note for item No:14 Colours/ Shade shall be approved by GE Notes for item No:12 to 14: (i) All safety measures for the safety of workers shall be ensured by contractor before execution of work. Insurance of workers shall be got done by contractor before execution of the work and the cost for the same shall be deemed to be included in rate quoted by contractor. (ii) Quoted rate shall deemed to be included the cost of necessary scaffolding for building upto 15.00m high.
Stainless steel letter/ Number 30cm high and 7.5cm wide, fixed to MS sheet, complete all as specified and directed by Engineer-in-Charge.
Brass Embelem 50 cm High Oval Shape, complete all as specified and directed by Engineer-in-Charge.
Sheet glass 4 mm thick, ordinary quality and glazing with oil putty or wooden bead in squares not exceeding 0.5 Sq. m in each pane including fixing with glass pins to hold glass in position upto 12.00 mtr height of building in and including Hacking out old broken glass panes of any thickness, size ,quality or description from wooden frames , glazed with putty or fixed with beads ,complete all as specified and directed by Engineer-in- Charge. Notes : (i) All safety measures for the safety of workers shall be ensured by contractor before execution of work. Insurance of workers shall be got done by contractor before execution of the work and the cost for the same shall be deemed to be included in rate quoted by contractor. (ii) Quoted rate shall deemed to be included the cost of necessary scaffolding for building upto 12.00m high. (iii) Serialwise allotment of space will be provided to the contractor for execution of work.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
BOQ_833924.xls
BOQ • 0.55 MB
Tender54.pdf
Tender Documents • 1.51 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .