Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹22.8 L+₹1.8 L (8.65%)Rejected-Finance 9 SHUBHASH BHAWAN RAJENDAR MARG MOUNT ABU 307 501 | MOUNT ABU | SIROHI | RAJASTHAN | 307501 | L2 | Rejected-Finance Other Than Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹43,000
Closing Date
29 Dec 2021, 6:00 pmClosed
GE (AF) CHILODA
GE (AF) Chiloda, Lekawada Patia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
PROVISION OF POWER CABLE AND DISTRIBUTION BOX WITH HARDSTANDING, WOODEN DOORS/ WINDOWS/ CUPBOARD PARTITION AND MISC WORK, TEXTURE PAINT AND SPECIAL REPAIR/ REPLACEMENT OF MAST LIGHTS, SIGNAGE BOARDS WITH LED LIGHTS AT VARIOUS LOCATIONS OF HQ SWAC COM
2021_MES_487855_2
8971/21-22/E8
Open Tender
Civil Works
Item Rate
180 days
VSN
AS PER NIT AND TENDER DOCUMEMNTS
7 documents required · 7 mandatory
₹500
GE (AF) CHILODA
₹43,000
Yes
12 Feb 2022
10 Dec 2021
31 Dec 2021
10 Dec 2021
29 Dec 2021
17 Dec 2021
Amount
S&F 2nd class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specoified and as directed.
S&F 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, both face is covered with decorative face veneer with lipping/ frame to match, commercial type on both sides complete all as specified and as directed.
M&L for 12mm thick plywood with veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on both faces; fixed with screws to timber frame work complete all as specified and as directed.
M&L for 18/ 19mm thick prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination, fixed with screws to timber frame work complete all as specified and as directed.
M&L for 12mm thick prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination, fixed with screws to timber frame work complete all as specified and as directed.
S&F anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
S&F 125mm butt hinges, extruded brass, with mild steel hinge pin, bright polished and fixed, type C-21 complete all as specified and as directed.
S&F 75mm butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and as directed.
S&F brass handles of size 150mm, fabricated type polished bright complete all as specified and as directed.
S&F brass handles of size 100mm fabricated type polished bright complete all as specified and as directed.
S&F 150mm brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified and as directed.
S&F brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified and as directed.
S&F 150mm floor door stopper of brass body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed.
S&F 5.5mm thick sheet glass, ordinary quality and glazing with oil putty in square n. exc. 0.5 Sqm in each pane including moulding with framing complete all as specified and as directed.
S&F 5.5mm thick sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 Sqm in each pane including fixing in aluminium frame complete all as specified and as directed.
M&L for french polishing on wooden surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick joint free, area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick joint free, area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm,as in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick backing plaster of wall tiles in CM (1:4) complete all as specified and as directed.
M&L for glazed ceramic digital dark and light coloured tiles in vertical surfaces of size 450mm x 300 x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 10mm thick backing plaster in CM (1:4) complete all as specified and as directed.
M&L for 18-20mm thick Granite (of any type) tiles machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing including 20mm thick screed bed in CM (1:6) complete all as specified and as directed.
M&L for 18-20mm granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing including 15mm thick backing plaster in CM (1:4) complete all as specified and as directed.
Demolition of cement concrete in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for 100mm thik PCC (1:4:8) type D2 (using 40mm graded stone aggregates) as in subase of flooring complete all as specified and as directed.
M&L sand filling under floors as cushioning including watering and consolidation complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block, any shape and size confirming to IS : 15658-2006 of 60mm thickness, M-35 Grade complete all as specified and as directed.
M&L for preparation of old surfaces of wall and applying 3mm thick wall care putty complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of old surfaces of external wall and applying Texture Painting of approved shade, approved base coat and top coat as per manufacture instructions using hand/ roller brush etc. complete all as specified and as directed by Engr-in-Charge.
Surfaces excavation n. exc. 30cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and as directed.
Removing excavated material n. exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and as directed.
Demolition of brick masonry work built in cement mortar or cement lime mortar including removal of debries out side MD land, complete all as specified and as directed.
M&L for moorum/ red bajri filling in floors or pavings, laid in layers n. exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
M&L for hardcore of gauge n. exc. 63 mm, broken stone or boulders deposited, spread and levelled in layers n. exc. 15 cm thick, watered and rammed to a true surface with 8 to 10 ton roller compacted complete all as specified and as directed by Engr-in-Charge.
M&L for cement concrete (1:4:8) type D2 (using 40mm graded stone aggregates) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block of approved shape and size 80mm thickness, with minimum compressive strength of 40 N/Sqmm (M-40 Grade) without correction factor for chamfering, made in rubber moulds with 0.5mm thick scratch proof lacquer coating on top surface, with white cement and pigment, conforming to IS : 15658-2006 complete all as specified and as directed.
M&L for road side kerb with factory made precast cement concrete block of mix (1:3:6) type C1 (using 20mm graded stone aggregate) n. exc. 100mm in width and set in CM (1:4) complete all as specied and as directed by Engr-in-Charge.
M&L for cement concrete (1:2:4) type B2 (using 40mm graded stone aggregates) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for cement concrete (1:3:6) type C2 (using 40mm graded stone aggregates) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for brickwork with fly ash bricks, straight or curved on plan exc. 6m mean radius, built in CM (1:6) complete all as specified and as directed.
M&L for 5mm thick rendering in cement mortar (1:4) (as second coat), over and including 10mm thick rendering in cement mortar (1:6) (as first coat) on stone/ fly ash brick masonary/ PCC block masonry wall surface, including supply mixing liquid water proofing compound in second layer only as per manufacturers instructions, finished the surface even and smooth without using extra cement complete all as specified and as directed.
M&L for complete removal of existing treatment of old surface including brooming down/ steel wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts and trading oil and greasy spoutes and cleaning with water on wall complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of plastered wall surface including pilaster/ cornices etc. and applying two coats of acrylic emulison (exterior weather coat) paint of any tint as approved over one coat of primer applied as per manufacturer's instruction complete all as specified and as directed by Engr-in-Charge.
Supply, install, testing & commissioning outdoor type LT feeder panel box compartmental type, lockable fabrication with dimension 800mm(H) x 500mm(W) x 500mm(D) made by 3.15mm thick sheet CRCA approved weather proof design framed on angle iron (40mmx40mmx6mm) double door front and rear openable both side opening shutters duly painted two coat with siemens gray color, cable entry with glands, foundation /grouting on & including PCC as per site requirement, including indicator lamps voltmeter and amperemeter with one set of Aluminium Bus bar 200 Amp Cap and fixing with one incoming MCCB 100 Amps, 4 pole 25 KA - 01 No, outgoing MCCB 63 Amps, 4 pole, 16 KA - 02 Nos. and MCB SPN 40 Amps -01 No. and making all incoming outgoing electrical cable connections complete all as specified and as directed by Eng-in-Charge.
Supply and laying of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm, 3.5 Core complete all as specified and as directed by Eng-in-Charge. Note:- Excavation/ earth work will be measured and paid separately.
Supply and laying of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm, 4 Core complete all as specified and as directed by Eng-in-Charge. Note:- Excavation/ earth work will be measured and paid separately.
Supply and fixing of steel tubular swaged poles with two coat of aluminium paint ovar a coat of red oxide zinc chrome prime in externally exposed to view portion and black bituminous painting to intenal surface and portion embeded in concrete including marking of MES pole No. in black paint complete with cast iron base plate, finial tapper plug, bolts, nuts and screws as specified type 410 SP-31 (9 mtr long) complete all as specified and as directed by Eng-in-Charge. Note:- Excavation/ earth work/ PCC will be measured and paid separately.
Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/ loose soil for taking up/ laying cable/ pipe etc. complete all as specified and as directed.
Returning, filling in trenches, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose soil complete all as specified and as directed.
Supply and laying burnt brick old size sub class 'B' laid in trenches abutting each other with a gap not exceeding 10mm, vertically over the cable for cable protection complete all as specified and as directed.
S&F GI tubing 40mm dia light grade in protection of cable of difference size laid in trench under road/ foot path or fixed on pole with necessary clamps with bolts etc. complete all as specified and as directed.
Labour only for boring under road/ drain by manual method for inserting the light grade pipe GI tubing up to 80mm dia cable protection complete all as specified and as directed by Engineer-in-Charge.
S&F 1.5 Sqmm, 3.0 Core PVC insulated, unsheathed multistranded copper conductor flexible cable 1100 Volts grade from junction box to street light fitting complete all as specified and as directed by Engr-in-Charge.
S&F PVC box of outside size 350mm x 250mm x 150mm and inside size 300mm x 200mm x 105mm including 4 Nos. of bus bar strip of aluminium of size 25mm x 4mm suitable for 440 Volts of suitable Amps rating including 1 No. MCB SPN, 6 to 32 Amps, 250 Volts with 'C' Curve, to be fixed on pole with clamp complete all as specified and as directed.
S&F LED street light fitting 70/ 72 Watt 230 V, AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impactand corrosion resistant including thermal management in multiple optics complete with IP 65/ 66 protection complete all as specified and as directed.
M&L for earthing complete in repairs with galvanised steel earth electrode 60cm x 60cm x 6mm burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised earth lead as GI strip of 32mm x 6mm dia by means of bolts, nuts, check nuts and washer etc. made of galvanised iron and connected to earthing test point all as shown in electrical plate No. 3 of SSR Part-I 2009 and as specified or indicated and testing on completion including excavation/ earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 40mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete all as specified and as directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) necessary excavation work is included in this item.
M&L for PCC (1:2:4) type B1 (using 20mm graded stone aggregates) as in coping of pole complete all as specified and as directed.
S&F street light bracket made out of 40mm light grade GI tubing minimum 1.2 mtr ling with suitable adapter to suit the opening of street light on one end alongwith integrated fabricated adapter round cup type with 4 Nos. studs on outer side to fix the bracket on top of existing steel tubular pole one way, with necessary MS clamps with one coat of red oxide and two coats of aluminium paint upon fabricated adapter including nut, bolt, washers complete all as specified and as directed by Engineer-in- Charge.
S&F in repair 100 Watt LED flood light with pressure die-cast aluminium housing, complete with all accessories, energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP-66 flood light with high power LEDs as light source, suitable for highlighting architectural facade highmast and general purposelighting W Turo Floodlight luminaires with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 Protection fixed in existing clamp and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and as directed by Engineer-in-Charge.
Taking down unserviceable flood light from high mast and S&F 195 W flood light system lumen 23500 lumen, CCt 5700 K, CRI/ SDCM 70 < 5, Class-1 electrical insulation, IP-66, IK-08, Class B serviceability, mounting via shaped bracket aiming scale angle, universal installation, Efficiency 120 Lm/ W, Surge 4 kv internal and 10 kv external, fixed output driver High power LED pressure dia cast Housing/ Anti dust exposed Lens, THD ≤ 10% (at full load), Exposed lens Optics polycarbonates, Optical (AWB, SWB, AMB, SMB, NB) Life L70B50 @ Hrs @ 35 degree ambient, BIS approbation, Tambient 35 degree, Driver protections 440V (p2p) protection for 8 hrs, high cut off @ 325 ± 15 V, auto restart, Dimension 538mm x 62mm x 243mm and weight 7 Kg (nominal) operating voltage 120-277V complete all as specified and as directed.
Taking down unserviceable cable and S&F 2.5 Sqmm, 5 Core, PVC insulated, round sheathed multistranded copper conductor flexible cable1100 Volts grade from junction box to High Mast light fitting complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable MCB and S&F MCB, TPN, 415 Volts, 40 Amps capacity complete all as specified and as directed by Engineer-in-Charge.
Re-winding of 1.5 HP capacity induction motor and including removing old burnt copper wire as per existing gauge and insulated paper, varnishing including cleaning/ greasing alongwith chain as existing size and length including connection of electrical wiring complete all as specified and as directed by Engineer-in-Charge.
Taking down old unserviceable Gear from High Mast pole and Repair/ servicing of Gear system for drum movement and fixing as existing position including all connection complete all as specified and as directed by Engineer-in-Charge.
Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electrical power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm, 4 Core complete all as specified and as directed.
S&F electronic timer for high mast light fix in panel including all connections complete all as specified and as directed.
S&F of internally illuminated LED based with double/ single sided sliding sheet opening arrangement for easy maintenance mandatory/ information signage of various sizes made out of 4.0mm thick glare free poly carbonate sheet at front and back (except is single sided where 2mm aluminium is provided on back). The body shall be fabricated from 2.0mm thick powder coated anodized aluminium profile having minimum width of 150mm and supported by 63mm frangible aluminium legs with MS die cast base plate at as per ICAO norms. Light source shall be highly luminous, long life typical 50,000 Hrs type 11 Nos LEDs of 0.5 Watt or equivalent (Osram/ Philips/ Nichia/ Edison) assembled on each PCB of minimum size 700mm x 20mm x 2mm for boards having height 800mm or more. Efficiency of LED shall have delivered minimum output 80 lumens per watt and colour temperature should be more than 5000 Kelvin with proper heat dissipation. These aluminimum PCBs should be placed across the length of the board to ensure uniform distribution of light across the board. The sinage boards with length varying from 800mm to 3000mm shall be suitable for operation on series circuit at variable current from 2.8 Amps to 6.6 Amps (brightness of the signage should be constant with current variation) including supply and installation of suitable capacity/ wattage electronic converters.
All the signage shall have letters and symbols made by computerized cutting of vinyl and pasting on the polycarbonate sheet from inside/outside of the sign face of required color as per ICAO. (Alternate array of LED on front and back in double sided boards)
(a) Double sided (i) K / ↑ IAF APRON K 2.5 x 0.85 = 2.125. (ii) ← M K / K M → 2.225 x 0.85 = 1.9125. (iii) 0.5 K 2.5 x 0.85 = 2.125. (iv) M IAF APRON ↑ / M 2.90 x 0.85 = 2.4650. (v) ↖ IAF APRON I ↖ K / F → 2.90 x 0.85 = 2.4650.
Supply, installation testing and commissioning of operational guidance signage of various sizes at various location at operational area of Comn Flt Ahmedabad. The signages should be intalled in (1:2:4) grade cement concrete of 400mm x 400mm x 500mm (for legs) and a total base of 150mm thick which extends all around the board with the distance of 1500 mm (front, back and both the dises). The concrete base and leg foundation should be on the same level and 20-25 mm above the ground level complete all as specified and as directed. Note:- Measurement shall be of plan area of concrete base.
Haritwal traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .