Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹1.0 Cr+₹44.3 L (73.1%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹1.2 Cr+₹59.1 L (97.5%)Rejected-Finance NALAKATH HUB AREECODE MALAPPURAM 673639 | MALAPPURAM | KERALA | 673639 | L3 | Rejected-Finance L3 | |
| 4 | Rejected-Technical 19 195 A 1 ATC BUILDING MOOLEPADAM NAGAR ROAD HMT JN KALAMASSERY P O KOCHI 683104 | KOCHI | ERNAKULAM | KERALA | 683104 | - | Rejected-Technical TECHNICALLY DISQUALIFIED |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
31 Dec 2019, 5:00 pmClosed
MANAGER(E-Tender)
Manager (E-tender) STEEL INDUSTRIALS KERALA LTD. ATHANI P.O THRISSUR- 680 581
Augmentation and Enhancement of the STP at Kumarakom, Kottayam District
2019_SILK_330095_2
SILK/PEED/S-3452/2019-20/
Open Tender
Miscellaneous Works
Item Rate
60 days
Kumarakom
As per tender documents
5 documents required · 5 mandatory
₹2,950
online
₹50,000
Yes
28 May 2020
23 Dec 2019
2 Jan 2020
23 Dec 2019
31 Dec 2019
23 Dec 2019
23 Dec 2019 - 31 Dec 2019
Amount
AUGMENTATION AND ENHANCEMENT
Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved (15.60)
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.(15.56)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size(5.1.2)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to the floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)(5.2.2)
Centering and shuttering including strutting, propping etc. and removal of form for all heights :Suspended floors, roofs, landings, balconies and access platform (5.9.3 )
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (5.9.2)
Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).(5.3)
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more(5.22.6)
Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster(13.9.1)
12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)(13.7.2)
6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)(13.16.1)
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work(13.60.1)
Supplying and fixing C.I cover with frame (light duty) 610 x 610 mm internal dimensions, total weight of cover and frame to be not less that 38 kg(weigh of cover 23 kg and weight of frame 15 kg)( od114977/2019_2020)
Providing sleeve hole for 110mm diameter GI piping lines (Puddle flanges) in exisiting 200 mm depth of RCC walls(LMR)
Supply and installation of Pumpout pumps with accessories including electrical charges(LMR)
5 HP SP3 LM 3ph Pump make:(Kirloskar,lubi or equvalent) as approved by engineer in charge
3 Ph Motor for running 5HP PUMP make:(Kirloskar,lubi or equvalent) as approved by engineer in charge
2" Brider hose of ISI Marked as approved by engineer in charge
2" Lovejoy coupling of ISI Marked as approved by engineer in charge
2" C.I butterfly valve of ISI Marked as approved by engineer in charge
2" C.I disc NRV valve of ISI Marked as approved by engineer in charge
1/2" S.S Needle Valve of ISI Marked as approved by engineer in charge
6" Pressure Guage of ISI Marked as approved by engineer in charge
2" GI Pipe of ISI Marked as approved by engineer in charge
2" GI Flange of ISI Marked as approved by engineer in charge
2" GI Bend of ISI Marked as approved by engineer in charge
Supply of 2.5 sqmm 3 core copper armoured cable of ISI Marked as approved by engineer in charge.
cable gland
Motor starter for 5 hp pump of ISI Marked as approved by engineer in charge.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Supply and installlation of Feed pump with accessories including electrical charges (LMR)
1 Hp Grinder Pump make:(Kirloskar,lubi or equvalent) as approved by engineer in charge
1 1/2" C.I butterfly Valve of ISI Marked as approved by engineer in charge
1 1/2" C.I disc NRV of ISI Marked as approved by engineer in charge
1/2" S.S Needle brass Valve of ISI Marked as approved by engineer in charge
6" Pressure Guage of ISI Marked as approved by engineer in charge
1 1/2" brider Hose of ISI Marked as approved by engineer in charge
1 1/2" Gi flange of ISI Marked as approved by engineer in charge
1 1/2" Gi Bend of ISI Marked as approved by engineer in charge
Supply of 2.5 sqmm 3 core armoured cable of ISI Marked as approved by engineer in charge
Cable gland,
copper wire for earthing
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Supply and installlation of Filter feed pump with accessories including electrical charges(LMR)
KDS 225++ 2 Hp Pump with motor make:(Kirloskar,lubi or equvalent) as approved by engineer in charge
1 1/2" C.I butterfly Valve of ISI Marked as approved by engineer in charge
2" C.I butterfly Valve of ISI Marked as approved by engineer in charge
1" brass Valve of ISI Marked as approved by engineer in charge
1/2" S.S Needle Valve of ISI Marked as approved by engineer in charge
6" Pressure guage of ISI Marked as approved by engineer in charge
1 1/2" C.I disc NRV of ISI Marked as approved by engineer in charge
2" Gi Pipe of ISI Marked as approved by engineer in charge
1 1/2" Gi Pipe of ISI Marked as approved by engineer in charge
1 1/2" GI Flange of ISI Marked as approved by engineer in charge
2" Gi Flange of ISI Marked as approved by engineer in charge
1 1/2"Gi Bend of ISI Marked as approved by engineer in charge
2" Gi Bend of ISI Marked as approved by engineer in charge
Supply of 2.5 sqmm 3 core armoured cable of ISI Marked as approved by engineer in charge
cable Gland
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Supply and installation of Sludge pump with all accessories including electrical charges (LMR)
1 Hp SPOM Pump make:(Kirloskar,lubi or equvalent) as approved by engineer in charge
1 1/2" C.I butterfly Valve of ISI Marked as approved by engineer in charge
2" C.I butterfly Valve of ISI Marked as approved by engineer in charge
1 1/2" C.I disc NRV of ISI Marked as approved by engineer in charge
1/2" S.S needle Valve of ISI Marked as approved by engineer in charge
6" Pressure Guage of ISI Marked as approved by engineer in charge
1 1/2" Gi Pipe of ISI Marked as approved by engineer in charge
2" Gi Pipe of ISI Marked as approved by engineer in charge
1 1/2" Gi Flange of ISI Marked as approved by engineer in charge
2" Gi Flange of ISI Marked as approved by engineer in charge
1 1/2" Gi Bend of ISI Marked as approved by engineer in charge
2" Gi Bend of ISI Marked as approved by engineer in charge
Supply of 2.5 sqmm 3 core copper armoured cable of ISI Marked as approved by engineer in charge
Cable Gland
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Supply and installation of Air blower with motor with all accessories including electrical charges (LMR)
BB 42 Air Blower with Motor (Make:Kay/Rootech/Blowvacc ) ,as approved by engineer in charge
3" C.I disc NRV of ISI Marked as approved by engineer in charge
6" Pressure Guage of ISI Marked as approved by engineer in charge
1/2" S.S Needle Valve of ISI Marked as approved by engineer in charge
3" Gi Pipe of ISI Marked as approved by engineer in charge
2" Gi Pipe of ISI Marked as approved by engineer in charge
3" C.I butterfly Valve of ISI Marked as approved by engineer in charge
2" C.I butterfly Valve of ISI Marked as approved by engineer in charge
Supply of 2.5 sqmm 3 core Copper armoured cable of ISI Marked as approved by engineer in charge
Cable Gland
copper wire for earthing
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Supply and installation of Pressure Sand Filter & Carbon filter with media and accessories.(LMR)
136x72 FRP Filters of ISI Marked as approved by engineer in charge
1 1/2" - 1" pebbles
1" - 3/4" Pebbles
1/2" - 1/4" Pebbles
3/4" - 1/2" Pebbles,
Activated Carbon
2" Astm pipe of ISI Marked as approved by engineer in charge
1" Astm pipe of ISI Marked as approved by engineer in charge
2" Astm Flange of ISI Marked as approved by engineer in charge
2" Astm Elbow of ISI Marked as approved by engineer in charge
2" Astm Tee of ISI Marked as approved by engineer in charge
2"x1 Astm Reducer of ISI Marked as approved by engineer in charge
2"x1/2" Astm Reducer of ISI Marked as approved by engineer in charge
2" Valve of ISI Marked as approved by engineer in charge
1" Astm Valve of ISI Marked as approved by engineer in charge
1/2" S.S Needle Valve of ISI Marked as approved by engineer in charge
6" Pressure Guage of ISI Marked as approved by engineer in charge
Supply and installation of Dozing system with dozing tank and accessories - Dozing Pump with 100 Ltr Dozing Tank (Make :Edoze/UKL) as approved by engineer in charge.(LMR)
Supply and installation of Electrical Control Panel with all accessories as required.(LMR)
2 x 1.4 Mtr sizeControl Panel Board
63 Amp 3 ph Isolation Switch
Neutral Link
5 mtr Mcb & contactors mounting channel
20 amp 3 ph MCB
10 amp 2 pole MCB for Voltage control
contactors
Auxyliary contactors
2.5 mm cable connector
4 mm cable connectors
On & Off Delay Timer
Ferrools ( numbering & alphabetical )
nuts & Blots & screws
4 mm 2.5 mm & 1.5 mm wire lugs ( ring type & pin type )
440v voltmeter
Ammeter
Green Indicator
Red indicator
Yellow indicator
combined socket unit
light with switch ( inside th panel board )
Copper Busbar box + control wiring accessories
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes.( Passage with Ladder - Ms Material with Scafolding Ladder ,Platform etc)(10.16.1)
MBBR media and diffusers - MBBR Media 22mm x 15mm, , 6 Nos. Fine Bubble 2.5" x 39" Diffusers(LMR)
Supply and installation of Aeration grid -with all accessories as required(LMR)
3" Astm Pipe of ISI Marked as approved by engineer in charge
3"x1" Astm Reducer of ISI Marked as approved by engineer in charge
3" Astm Tee of ISI Marked as approved by engineer in charge
3" Astm Elbow of ISI Marked as approved by engineer in charge
1" Astm Pipe of ISI Marked as approved by engineer in charge
1" Astm FTA of ISI Marked as approved by engineer in charge
Fabrication Charges of ISI Marked as approved by engineer in charge
Internal wiring and lighting -
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor singlecore cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthingthe point with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable etc. as required.
Group A(1.10.1)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire(1.14.1)
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire(1.14.2)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
2 x 1.5 sq. mm(1.17.2)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessedconduit as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc . as required.
6 Module (200 mmX75 mm)(1.27.4)
8 Module (125 mmX125 mm) (1.27.5)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.(1.32)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providingand fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.(1.31)
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junctionbox/ wooden block including connections etc. as required.(1.33)
Supplying and fixing following modular switch/ socket on the existing modular plate&switch box includingconnections but excluding modular plate etc. as required.
5/6 A switch(1.24.1)
3 pin 5/6 A socket outlet(1.24.4 )
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.(1.25)
supply and Fixing of 150mm sweep Light Duty Exhaust fan in plastic body with self opening lowers working on 230V single phase A/C..standard make as approved by the site engineer.(LMR)
supply and Fixing of 1200 mm sweep- 5 star rated Ceiling fan, complete with 300mm downrod, canopies, shackles and blades working on 230 /240 AC.standard make as approved by the site engineer.(LMR)
Supplying and installation of LED tube light fitting suitable for single 20 W with lampholder.(Make:Philips/Crompton) (LMR)
Supply and installation of 9W LED bulb. (Make: Philips/Crompton) (LMR)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
16 way, Double door(2.3.4)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.
Single pole(2.10.1)
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Earthing with G.I. earth pipe 2.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required(LMR)
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required
2.65 mm copper conductor (12 SWG)(90.16.1.2)
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 25 sq mm with factory made clamp(90.12.41.20)
Supply & Erection of Vertical/Horizontal type M.S cable trays and cable supports fabricated out of M.S angles (ISA) and M.S Flats with sufficient width and spacing between successive cross members and supported at adequate spacing.The cable trays and supports shall be painted with 2 coats of Zinc chromate primer and 2 coats of enamel paint.(LMR)
Skid Assembly - Concrete Foundation & Steel Bar skid Fabricated in required size for fixing Ultra Filteration system(LMR)
Supply and installation of Membrane Housing - 280mm x 1830mm 100kd 81 M2 , 3 port with PPGF End Caps, of ISI Marked as approved by engineer in charge (LMR)
Supply and installation of Pump 10M3/Hr, (make:CRI,Kirloskar or equivalent ) of ISI Marked as approved by engineer in charge (LMR)
Supply and installation of Pump 20M3/Hr, (make:CRI,Kirloskar or equivalent ) of ISI Marked as approved by engineer in charge (LMR)
Supply and installation of solinoid Valves - 2"of ISI Marked as approved by engineer in charge (LMR)
Supply and installation of Micro Filter 21"of ISI Marked as approved by engineer in charge (LMR)
Supply and installation of Coupling (LMR)
Supplying and fixing of Dozing Tank - 100 Ltr of ISI Marked as approved by engineer in charge (LMR)
Supplying and fixing of Dozing pump - FE A 105 of ISI Marked as approved by engineer in charge(LMR)
Supplying and fixing of Back wash tank - 20 KL of ISI Marked as approved by engineer in charge (LMR)
Fittings & other Accessories - ASTM Pipes, Valves ,Flanges,couplings etc of ISI Marked as approved by engineer in charge (LMR)
Supplying and fixing Rota Meter of ISI Marked as approved by engineer in charge (LMR) (0 - 12000lph)
Supply and installation of Electrical Control Panel with all accessories as required.(LMR)
2 x 1.4 Mtr sizeControl Panel Board
63 Amp 3 ph Isolation Switch
Neutral Link
5 mtr Mcb & contactors mounting channel
20 amp 3 ph MCB
10 amp 2 pole MCB for Voltage control
contactors
Auxyliary contactors
2.5 mm cable connector
4 mm cable connectors
On & Off Delay Timer
Ferrools ( numbering & alphabetical )
nuts & Blots & screws
4 mm 2.5 mm & 1.5 mm wire lugs ( ring type & pin type )
440v voltmeter
Ammeter
Green Indicator
Red indicator
Yellow indicator
combined socket unit
light with switch ( inside th panel board )
Copper Busbar box + control wiring accessories
Supply and installation of Softner - 4" T/B 3072 with Resin 220 NA Indion , Salt injection ( Regeneration ) system, salt solution tank of ISI Marked as approved by engineer in charge(LMR)
Fittings & other Accessories for softner - ASTM Pipes, Valves ,Flanges,couplings etc required for Softne of ISI Marked as approved by engineer in charge (LMR)
RAISING THE FLOOR LEVEL OF EXISTING PUMP ROOM
Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved(15.6)
Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)(15.2.1)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)(4.1.8)
Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge(50.2.25.1)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1/2:3 (cement : 11/2 coarse sand : 3 graded stone aggregate 20 mm nominal size)(4.1.2)
Centering and shuttering including strutting, propping etc. and removal of form for all heights :Foundations, footings, bases of columns, etc. for mass concrete (5.9.1)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate(11.3.1)
Floor painting with floor enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work(13.66.1)
Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15 cm in : CM 1:6 ( 1 cement : 6 coarse sand ) etc complete(50.6.1.7)
12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)(13.7.2)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer(13.43.1)
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work(13.60.1)
Supplying at site:Welded steel wire fabric of required width having rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer (Priming & painting to be paid for separately)(16.15)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture .(13.62.1)
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.(16.68)
NEW OPERATOR ROOM, WASH ROOM AND A ROOM FOR RELOCATED FILTER PRESS
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared (2.31)
Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth(2.33.2)
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil (2.8.1)
Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge (50.2.25)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) (4.1.8)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) (7.1.1)
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete (50.6.1.8)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size (5.1.2)
Centering and shuttering including strutting, propping etc. and removal of form for all heights :Lintels, beams, plinth beams, girders, bressumers and cantilevers (5.9.5)
Centering and shuttering including strutting, propping etc. and removal of form for all heights :Suspended floors, roofs, landings, balconies and access platform(5.9.3)
Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).(5.3)
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more (5.22.6)
Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth for 10 cm thick wall in CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete (50.6.3.1)
6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) (13.16.1)
12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand) (13.7.2)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate (11.3.1)
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.(11.37)
Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.(11.36)
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work (13.60.1)
Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece (10.5.2)
Item Shifted to head 14 as item 14.74. Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (10.25.2)
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (10.1)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes. (10.16.1)
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (12.50)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture . (13.62.1)
Providing and applying crystalline mortar by mixing in the ratio of 4.5 : 1 (4.5 parts crystalline mortar : 1 part water) for the treatment of faulty construction joints, cracks, tie rod holes and spalled & honeycombed surface of RCC underground structures like basement, water tanks, bridge deck etc. to ensure water tightness. The crystallie mortar shall conform to the EN 1504-3 having compressive strength Class R4 (?45 MPa) and adhesive bond strength Class R3 (?1.5 MPa). The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakageFor patching of tie rod holes, prepared tie rod hole surface and then primed the area with integral crystalline slurry @0.070kg/sqm and while the surface is tacky repair and then filled the tie rod holes with crystalline [email protected] per hole. The crystalline mortar should be tightly rodded into tie rod holes or packed tightly (For 25x25x25 mm tie rod hole, use 0.040kg to fill the hole). (22.25.2)
Supplying and fixing Aluminium panneled door of size 1.0mx2.10m of 8mm thk Novaoan board panels including all as per the instruction and specification cmpte. (LMR)
Supplying and fixing Aluminium window of size 1.50mx1.50m sliding window of 4mm thk clear glass panels including all fittings etc complete as per the instruction and specification complete (LMR)
Supplying and fixing fiber Reinforced Panel door of size 0.70mx2.10mx25mm thick etc complete(LMR)
Supplying and installing ready made PVC Septic tank below 15 flush capacity etc complete as per direction (LMR)
Plumbing Works
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. (2.8.1)
Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall (50.18.9.19.1)
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow (50.18.9.22.1)
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall (50.18.9.14.1)
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2 (50.18.8.2.2)
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge Concealed work, including cutting chases and making good the wall etc. 15 mm pipe 10kgf/cm2 (50.18.8.1.2)
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 (50.18.9.9.1)
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :18.32.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 (18.32)
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lid each (17.2.2)
Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. (50.17.1.4)
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap (17.7.4)
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40 mm dia (17.28.2.2) each
Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design. (17.30)
Providing and fixing PTMT grating of approved quality and colour.Circular type 100 mm nominal dia (18.58.1.1)
Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately).(18.14 )
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 18.18.2 20 mm nominal bore each 327.05
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter (18.22.1)
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore (18.51.1)
Providing and fixing C.P. brass bib cock of approved quality conformingto IS:8931 :15 mm nominal bore(18.49.1)
Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. (50.17.1.1)
Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. (50.17.1.2)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable ocking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(18.48 )
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of Rectangular shape 453x357 mm (17.32.2)
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter (18.22.1)
Water connection charges to KWA(LMR)
Electrification Works
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor singlecore cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthingthe point with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable etc. as required.
Group A(1.10.1)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire(1.14.1)
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire(1.14.2)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
2 x 1.5 sq. mm(1.17.2)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessedconduit as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc . as required.
1 or 2 Module (75 mmX75 mm)(1.27.1)
6 Module (200 mmX75 mm)(1.27.4)
8 Module (125 mmX125 mm) (1.27.5)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.(1.32)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providingand fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.(1.31)
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junctionbox/ wooden block including connections etc. as required.(1.33)
Supplying and fixing following modular switch/ socket on the existing modular plate&switch box includingconnections but excluding modular plate etc. as required.
5/6 A switch(1.24.1)
3 pin 5/6 A socket outlet(1.24.4 )
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.(1.25)
supply and Fixing of 200 mm sweep Light Duty Exhaust fan in plastic body with self opening lowers working on 230V single phase A/C..standard make as approved by the site engineer.(LMR)
supply and Fixing of 1200 mm sweep- 5 star rated Ceiling fan, complete with 300mm downrod, canopies, shackles and blades working on 230 /240 AC.standard make as approved by the site engineer.(LMR)
Supplying and installation of LED tube light fitting suitable for single 20 W with lampholder.(Make:Philips/Crompton) (LMR)
Supply and installation of 9W LED bulb. (Make: Philips/Crompt(LMR)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
16 way, Double door(2.3.4)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.
Single pole(2.10.1)
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Earthing with G.I. earth pipe 2.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required(LMR)
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required
2.65 mm copper conductor (12 SWG)(90.16.1.2)
Supplying and fixing of 1/2 hp motor pump with all accessories are included Make:(crompton / v-guard)(LMR)
Supply and installation of C.C.T.V Camera with UPS, DVR (LMR)
Supply and installation of Hitvision 2 MP bullet High resolution night camera
Supply and installation of DVR,UPS Complete as required
Supply and laying Cabling of CCTV Camera
TRANSDOT PRIVATE LIMITED
Meena Mamu
NALAKATH INFRASTRUCTURE LLP
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_461833.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .