Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹41,481Accepted-AOC | ₹41,481 | 1 | Accepted-AOC LOWEST |
| 2 | 2₹42,081Rejected-Finance | ₹42,081 | 2 | Rejected-Finance NOT LOWEST |
| Sl No | Description | Qty | Unit | MUTTATH AGENCIES L1 | Ramani Solar L2 |
|---|---|---|---|---|---|
| 1.00ELECTRIFICATION. ( List of materials used for the work approved by the DLTCE under LSGD Kottayam is attached as separate document) | |||||
| 1.00 | 90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm | 20 | metre | 80 ₹1,600 | 100 ₹2,000 |
| 1.00 | 1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm | 20 | metre | 110 ₹2,200 | 120 ₹2,400 |
| 1.00 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch | 1 | each | 250 ₹250 | 250 ₹250 |
| 1.00 | 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) | 1 | each | 100 ₹100 | 100 ₹100 |
| 1.00 | 90.6.5.9:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 0.75 sq mm | 10 | metre | 50 ₹500 | 50 ₹500 |
| 1.01 | 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply | 9 | each | 3,000 ₹27,000 | 3,000 ₹27,000 |
| 1.01 | OD49710/2025-2026:70 W LED Flood light output > 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor >0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD <10%, power factor >0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) ( Crompton/hovels, Philips, Lukker} | 2 | each | 1,800 ₹3,600 | 1,800 ₹3,600 |
| 1.01 | OD49711/2025-2026:Supply , fitting of 60 W LED bulb for street light fittings ( Orient , colours or equallant make ) | 3 | each | 650 ₹1,950 | 650 ₹1,950 |
| 1.01 | OD49713/2025-2026:Charges for Dismantling the existing damaged Ceiling fan, light fitting and fitting new in same position as required | 1 | Job | 4,281 ₹4,281 | 4,281 ₹4,281 |
Tender Value
₹41,481
EMD Value
₹1,037
Closing Date
25 Jul 2025, 3:30 pmClosed
AE, Pala Municipality
Office of the Assistant Executive Engineer, Pala
Annual Plan-PALA MUNICIPALITY Project No-149/25-KOTTARAMATTOM BUS STAND RENOVATION -General Electrical Work
2025_LSGD_776565_4
LSGD/CELSGD/2025-2026/1
Open Tender
Electrical Works
90 days
Pala Municipality
Please refer Tender documents.
11 documents required · 11 mandatory
₹335
₹1,037
26 Mar 2026
16 Jul 2025
28 Jul 2025
16 Jul 2025
25 Jul 2025
16 Jul 2025
Amount
ELECTRIFICATION. ( List of materials used for the work approved by the DLTCE under LSGD Kottayam is attached as separate document)
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
90.6.5.9:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 0.75 sq mm
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
OD49710/2025-2026:70 W LED Flood light output > 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor >0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD <10%, power factor >0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) ( Crompton/hovels, Philips, Lukker}
OD49711/2025-2026:Supply , fitting of 60 W LED bulb for street light fittings ( Orient , colours or equallant make )
OD49713/2025-2026:Charges for Dismantling the existing damaged Ceiling fan, light fitting and fitting new in same position as required
Ramani Solar (BID ID -2261796)
Bidder Name
MUTTATH AGENCIES
Ramani Solar
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf