Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 CrAccepted-AOC | ₹3.1 Cr | L1 | Accepted-AOC Lowest Bid Accepted |
| 2 | L2₹3.1 Cr+₹88,028.80 (0.28%)Rejected-Finance FLAT NO 304 SN TOWERS JAGANNADHAPURAM JUNCTION AKKAYYAPALEM VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | ₹3.1 Cr+₹88,028.80 (0.28%) | L2 | Rejected-Finance Not Being Lowest Bidder |
| 3 | L3₹3.3 Cr+₹17.4 L (5.61%)Rejected-Finance M S VIJAYA VINAYAKA INFRA DOOR NO 39 33 62 1 4 PLOT NO MIG 95 96 SAMYAM ENCLAVE FLAT NO 101 VUDA COLONY MADHAVADHARA MARRIPALEM VISAKHAPATNAM 530018 | VISAKHAPATANAM | ANDHRA PRADESH | 530018 | ₹3.3 Cr+₹17.4 L (5.61%) | L3 | Rejected-Finance Not Being Lowest Bidder |
| 4 | L4₹3.3 Cr+₹18.5 L (5.98%)Rejected-Finance MIG 1 12 GULLALAPALEM VUDA COLONY SRIHARIPURAM MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530011 | ₹3.3 Cr+₹18.5 L (5.98%) | L4 | Rejected-Finance Not Being Lowest Bidder |
| 5 | L5₹3.3 Cr+₹19.0 L (6.13%)Rejected-Finance DOOR NO 50 53 2 5 FLAT NO 504 SRI SAI VENKATESHWARA RESIDENCY NE LAYOUT SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | ₹3.3 Cr+₹19.0 L (6.13%) | L5 | Rejected-Finance Not Being Lowest Bidder |
| Sl No | Description | Qty | Unit | Mahamaruti Constructions L5 | VIJAY VINAYAKA INFRA L3 | MURALI KRISHNA ASSOCIATES L2 | JMR INFRAS L1 | S A R CONSTRUCTIONS L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | SCHEDULE 'A' PART-I [B/R Works]:
M & L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces duly mixed with and including water proofing compound as per manufacturers instructions, finished even and smooth with out using extra cement complete all as directed | 3,542 | SqM | 255 ₹9,03,210 | 257 ₹9,10,294 | 270 ₹9,56,340 | 153 ₹5,41,926 Lowest | 200 ₹7,08,400 |
| 2.00 | M & L for providing and injecting chemical emulsion for post construction anti-termite treatment along the external wall below concrete or masonry apron using chemical emulsion CHLOROPYRIFOS 20 EC at 1% concentration at 2.25 litres per linear running metre including drilling and plugging holes with cement mortar (1:2) to match with the existing surface complete all as specified and directed by Engineer-in-Charge. | 116 | RM | 42 ₹4,872 | 33 ₹3,828 Lowest | 144 ₹16,704 | 100 ₹11,600 | 100 ₹11,600 |
| 3.00 | M & L for providing and injecting emulsion for post construction anti-termite treatment under existing floors using emulsion CHLOROPHYRIFOS 20 EC at 1% concentration at the rate of one litre per each hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar (1:2) to match the existing floor complete all as specified and directed by Engineer-in-Charge. | 258 | SqM | 129 ₹33,282 | 99 ₹25,542 Lowest | 234 ₹60,372 | 100 ₹25,800 | 225 ₹58,050 |
| 4.00 | M & L for providing and injecting chemical emulsion for post construction anti-termite treatment at points of contact of wood work by chemical emulsion CHLOROPYRIFOS 20 EC at 1% concentration at the rate of 0.5 litre per each hole by drilling 6mm dia holes at a downward angle of 45 Degree at 150mm centre to centre complete all as specified and directed by Engineer-in-Charge. | 1,080 | RM | 42 ₹45,360 | 33 ₹35,640 Lowest | 144 ₹1,55,520 | 100 ₹1,08,000 | 100 ₹1,08,000 |
| 5.00 | M & L for Providing light weight AAC block bats concrete 1:3:6 mix [1 part of cement : 3 parts of coarse sand : 6 parts of AAC block bats of size 40-60mm] mixed with and including approved water proofing compound as per manufacturers instructions as in filling in sunken floors, well rammed and compacted as required including demolition of existing concrete complete all as specified and directed by the Engineer-in-Charge:-
Notes:
[a] The AAC Block bats shall confirm to relevant IS and all necessary tests shall be caried out before incorporating the same in the work.
[b] Care shall be taken prior to filling, that all pipes passing through sunken portion are pressure tested by maintaining pressure for 24 hours and junctions of pipes passing through walls, slabs are well grouted and sealed. Necessary testing shall be carried out by ponding water for required depth and maintaining continusously for 72 hours and any leakage found shall be immediately rectified without any extra cost.
[c] Rate quoted by the contractor shall be deemed to include for the cost of working at all levels, leads and heights. | 57 | CuM | 5,999 ₹3,41,943 | 6,456 ₹3,67,992 | 4,500 ₹2,56,500 | 1,800 ₹1,02,600 Lowest | 2,500 ₹1,42,500 |
| 6.00 | M & L for filling Polymer modified non shrinking slurry with CEBEX 100 of Fosroc or equivalent chemical for sunken floors for toilets by drilling holes to a depth of 60mm and 20mm dia at 1m interval and applying 2mm thick brush bond over the concrete surfaces by mixing acrylic emulsion NITO BOND of Fosroc or equivalent with brush bond powder and water and testing the same for 48 hours with complete filling within the sunken floor as per manufacturers technical specifications complete all as directed. | 531 | SqM | 159 ₹84,429 | 100 ₹53,100 Lowest | 450 ₹2,38,950 | 450 ₹2,38,950 | 250 ₹1,32,750 |
| 7.00 | M & L for 40mm thick, PCC 1:2:4, type B-1, using 20mm graded stone aggregate as in flooring, finished even and smooth without using extra cement complete all as specified and directed. | 323 | SqM | 299 ₹96,577 | 250 ₹80,750 | 216 ₹69,768 | 180 ₹58,140 Lowest | 180 ₹58,140 Lowest |
| 8.00 | M & L for Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or
otherwise not exc 100 Sqcm superficial are of work complete all as specified and directed | 2,484 | PER CM DEPTH | 44 ₹1,09,296 | 20 ₹49,680 | 63 ₹1,56,492 | 20 ₹49,680 | 10 ₹24,840 Lowest |
| 9.00 | S & F Unplasticized PVC pipes 50mm bore of pressure rating 10 kgf/Sqcm complete all as directed | 41 | RM | 400 ₹16,400 | 559 ₹22,919 | 180 ₹7,380 | 300 ₹12,300 | 50 ₹2,050 Lowest |
| 10.00 | M & L for rendering 15mm thick in CM 1:3 on fair faces of brick work or concrete surfaces duly mixed with and including water proofing compound as per manufacturers instructions, finished even and smooth with out using extra cement complete all as specified and directed. | 531 | SqM | 260 ₹1,38,060 | 257 ₹1,36,467 | 270 ₹1,43,370 | 180 ₹95,580 Lowest | 200 ₹1,06,200 |
Tender Value
₹4.9 Cr
EMD Value
₹5.6 L
Closing Date
7 Nov 2025, 6:00 pmClosed
Col Shinde SS, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
SPECIAL REPAIRS TO BUILDING NO. P-7E EKATA AT NAVAL PARK NORA UNDER GE NB VISAKHAPATNAM
2025_MES_734393_1
82602/E8
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
As per NIT
9 documents required · 9 mandatory
₹2,000
Garrison Engineer Naval Base
₹5.6 L
Yes
10 Mar 2026
9 Oct 2025
10 Nov 2025
9 Oct 2025
7 Nov 2025
31 Oct 2025
9 Oct 2025 - 16 Oct 2025
Amount
SCHEDULE 'A' PART-I [B/R Works]: M & L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces duly mixed with and including water proofing compound as per manufacturers instructions, finished even and smooth with out using extra cement complete all as directed
M & L for providing and injecting chemical emulsion for post construction anti-termite treatment along the external wall below concrete or masonry apron using chemical emulsion CHLOROPYRIFOS 20 EC at 1% concentration at 2.25 litres per linear running metre including drilling and plugging holes with cement mortar (1:2) to match with the existing surface complete all as specified and directed by Engineer-in-Charge.
M & L for providing and injecting emulsion for post construction anti-termite treatment under existing floors using emulsion CHLOROPHYRIFOS 20 EC at 1% concentration at the rate of one litre per each hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar (1:2) to match the existing floor complete all as specified and directed by Engineer-in-Charge.
M & L for providing and injecting chemical emulsion for post construction anti-termite treatment at points of contact of wood work by chemical emulsion CHLOROPYRIFOS 20 EC at 1% concentration at the rate of 0.5 litre per each hole by drilling 6mm dia holes at a downward angle of 45 Degree at 150mm centre to centre complete all as specified and directed by Engineer-in-Charge.
M & L for Providing light weight AAC block bats concrete 1:3:6 mix [1 part of cement : 3 parts of coarse sand : 6 parts of AAC block bats of size 40-60mm] mixed with and including approved water proofing compound as per manufacturers instructions as in filling in sunken floors, well rammed and compacted as required including demolition of existing concrete complete all as specified and directed by the Engineer-in-Charge:- Notes: [a] The AAC Block bats shall confirm to relevant IS and all necessary tests shall be caried out before incorporating the same in the work. [b] Care shall be taken prior to filling, that all pipes passing through sunken portion are pressure tested by maintaining pressure for 24 hours and junctions of pipes passing through walls, slabs are well grouted and sealed. Necessary testing shall be carried out by ponding water for required depth and maintaining continusously for 72 hours and any leakage found shall be immediately rectified without any extra cost. [c] Rate quoted by the contractor shall be deemed to include for the cost of working at all levels, leads and heights.
M & L for filling Polymer modified non shrinking slurry with CEBEX 100 of Fosroc or equivalent chemical for sunken floors for toilets by drilling holes to a depth of 60mm and 20mm dia at 1m interval and applying 2mm thick brush bond over the concrete surfaces by mixing acrylic emulsion NITO BOND of Fosroc or equivalent with brush bond powder and water and testing the same for 48 hours with complete filling within the sunken floor as per manufacturers technical specifications complete all as directed.
M & L for 40mm thick, PCC 1:2:4, type B-1, using 20mm graded stone aggregate as in flooring, finished even and smooth without using extra cement complete all as specified and directed.
M & L for Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise not exc 100 Sqcm superficial are of work complete all as specified and directed
S & F Unplasticized PVC pipes 50mm bore of pressure rating 10 kgf/Sqcm complete all as directed
M & L for rendering 15mm thick in CM 1:3 on fair faces of brick work or concrete surfaces duly mixed with and including water proofing compound as per manufacturers instructions, finished even and smooth with out using extra cement complete all as specified and directed.
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 10mm thick in cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth and applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m, laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sq.m reinforced with polyester non-woven fabric of weight not less than 150 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion and finishing the surface with aluminium paint @ 0.1 Lit/Sqm complete including taking down existing Roof Treatment of any description complete all as specified and directed by the Engineer-in-Charge
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 10mm thick in cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth and applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m, laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sq.m reinforced with polyester non-woven fabric of weight not less than 150 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including taking down existing Roof Treatment of any description complete all as specified and directed by the Engineer-in-Charge
M & L for PCC 1:2:4, Type B-0, using 12.5mm graded stone aggregate as in roof padding / roof kerbs laid to slopes as directed finished the surfcaes even and fair without using extra cement complete all as specified and directed.
M&L for providing roof cooling ceramic tiles of size 300 x 300 mm, 7 to 8 mm thick, conforming to IS 15622, set and jointed in cement slurry and pointed flush with epoxy mortar to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:3 complete all as specified and as directed. [Note: The colour/ shade/ design of tiles shall be as approved by GE.]
M & L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement including taking down cement plaster on brick work or stone masonry walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as directed.
M & L for preparation of newly plastered surfaces of walls by using vaccume based sanding machine, removal of nails and applying two coats of Acrylic Washable Distemper by using auto roller/ airless sprayer over one coat of alkali resistant primer on wall surfaces over two or more coats of Cement based Wall Care Putty on walls by using multipurpose mixture for proper mixing of putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces complete all as specified and as directed. [Note:- The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicators before commencement of the work to GE for approval.]
M & L for Complete removal of existing treatment of any description from old surfaces surfaces by using vaccume based sanding machine, removal of nails and applying two coats of Acrylic Washable Distemper by using auto roller/ airless sprayer over one coat of alkali resistant primer on wall surfaces over two or more coats of Cement based Wall Care Putty on walls by using multipurpose mixture for proper mixing of putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces complete all as specified and as directed. [Note:- The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicators before commencement of the work to GE for approval.]
M & L for rendering 5mm thick in CM 1:3 on fair faces of ceiling surfaces, finished even and smooth with out using extra cement complete all as directed.
M & L for preparation of newly plastered surfaces of ceiling by using vaccume based sanding machine, removal of nails and applying two coats of Acrylic Washable Distemper by using auto roller/ airless sprayer over one coat of alkali resistant primer on wall surfaces over two or more coats of Cement based Wall Care Putty on walls by using multipurpose mixture for proper mixing of putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces complete all as specified and as directed. [Note:- The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicators before commencement of the work to GE for approval.]
M & L for preparation of old decorated surfaces of ceiling by brooming down, brushing and applying two coats of oil bound distemper complete all as spcified and directed.
M & L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directetd.
M & L for preparation of old decorated surfaces of walls by brooming down, brushing and applying two coats of white wash complete all as spcified and directed.
M & L for preparation of old painted steel surfaces of any description, not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint complete all as directed.
M & L for preparation of old painted brick / stone / concrete surfaces of any description, not otherwise described not exc 10cm in width or girth and applying two coats of synthetic enamel paint complete all as directed.
M & L for preparation of newly plastered surfaces of walls/ceiling and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over priming coat of exterior primer applied @ 0.90 litre/ 10sqm complete all as directed
M & L for complete removal of existing treatment, preparation of surfaces of walls/ceiling and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over priming coat of exterior primer applied @ 0.90 litre/ 10sqm complete all as directed
Demolition of Unreinforced Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M & L for double charged, vitrified coloured ceramic tiles 10mm thick (square/rectangular), area of each tile exceeding 0.42 Sqm but not exceeding 1.0 Sqm, as in floors set and jointed neat with epoxy grout and masking tape shall be put before putting the epoxy grout, (3mm joint filling shall be done using 3mm thick PVC spacers) grout shall be througly cleaned immediatlely and pointed in white or coloured to match the shade of the tile and laid over and including screed bed or bedding layer in CM 1:6, 15 mm thick complete all as specified and as directed.
M & L for rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement including taking down cement plaster on brick work or stone masonry walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as directed.
M & L for 25mm thick, PCC 1:2:4, Type B-0, using 12.5mm graded stone aggregate as in levelling course complete all as specified and as directed.
S & F in repairs Decorative type Stainless Steel Curtain Rod of 20 mm dia including PVC rings @ 100 mm centre to centre with suitable SS brackets to match with curtain rod complete all as specified and as directed.
Supplying and fixing of 20mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings fixed in walls / ceiling or laying in floors including taking down old GI tubing of 15mm dia complete all as specified and directed. [Note: Quoted rate is deemed to include for cutting chases, pinning in. making good to facings and pointing in cement mortar 1:3 wherever required as per site condition]
Supplying and fixing of 25mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings fixed in walls / ceiling or laying in floors including taking down old GI tubing of 20mm dia complete all as specified and directed. [Note: Quoted rate is deemed to include for cutting chases, pinning in. making good to facings and pointing in cement mortar 1:3 wherever required as per site condition]
Supplying and fixing of 40mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings fixed in walls / ceiling or laying in floors including taking down old GI tubing of 25/32mm dia complete all as specified and directed. [Note: Quoted rate is deemed to include for cutting chases, pinning in. making good to facings and pointing in cement mortar 1:3 wherever required as per site condition]
Supplying and fixing of 75mm bore (inner dia) CPVC pipes with CPVC Schedule 80 pipes & plain CPVC Schedule 80 fittings including all plain brass treaded fittings fixed in walls / ceiling or laying in floors including taking down old GI tubing of 75mm dia complete all as specified and directed. [Note: Quoted rate is deemed to include for cutting chases, pinning in. making good to facings and pointing in cement mortar 1:3 wherever required as per site condition]
S & F in repairs gun metal, globe or gate valves, 20mm bore with iron wheel head, screwed both ends for iron pipe and fixed suitable for CPVC pipes complete all as specified and as directed.
S & F in repairs gun metal, globe or gate valves, 40mm bore with iron wheel head, screwed both ends for iron pipe and fixed suitable for CPVC pipes complete all as specified and as directed.
S & F in repairs gun metal, globe or gate valves, 90mm bore with iron wheel head, screwed both ends for iron pipe and fixed suitable for CPVC pipes complete all as specified and as directed.
M & L for Cutting holes into or through brick walls built in cement mortar or otherwise not exc 150 Sqcm superficial area of work and making good in CM 1:3 or PCC 1:2:4, type B-1 complete all as specified and directed
M & L for Cutting holes into or through brick walls built in cement mortar or otherwise exc 400 Sqcm but not exc 0.1 Sqm superficial area of work and making good in CM 1:3 or PCC 1:2:4, type B-1 complete all as specified and directed
M & L for Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise exc 500 Sqcm but not exc 0.1 Sqm superficial area of work complete all as specified and directed
M & L for Cutting holes into or through Stone walls built in cement mortar or otherwise exc 400 Sqcm but not exc 0.1 Sqm superficial are of work and making good in CM 1:3 or PCC 1:2:4, type B-1 complete all as specified and directed
M & L for Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise exc 250 Sqcm but not exc 500 Sqcm superficial are of work complete all as specified and directed
S & F 160mm bore PVC (SWR) soil, waste and vent pipes, single socketed in any length with rubber ring joints fixed to walls or laid in sunken floors including dismantling of old CI pipes 150mm dia complete all as specified and directed.
S & F 110mm bore PVC (SWR) soil, waste and vent pipes, rain water pipes single socketed in any length with rubber ring joints fixed to walls or laid in sunken floors including dismantling of old CI/PVC pipes 100mm dia complete all as specified and directed.
S & F 110mm PVC (SWR) WC connector with Lip ring
S & F 110 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door complete all as specified and as directed.
M & L for 110mm bore PVC (SWR) bends any radius with access door complete all as specified.
M & L for 110mm bore PVC (SWR) branch piece double, (Double Y) equal or unequal with access door complete all as specified.
M & L for 160mm bore PVC (SWR) branch piece double, (Double Y) equal or unequal with access door complete all as specified.
S & F 110 mm bore PVC [SWR] Vent cowl complete all as specified and as directed.
S & F 75mm bore PVC (SWR) rain water pipes single socketed in any length with rubber ring joints fixed to walls or laid in sunken floors including dismantling of old pipe complete all as specified and directed.
M & L for 75mm bore PVC (SWR) bends any radius with access door complete all as specified.
M & L for 75mm bore PVC (SWR) branch piece double, (Double Y) equal or unequal with access door complete all as specified.
S & F 50mm bore PVC (SWR) rain water pipes single socketed in any length with rubber ring joints fixed to walls or laid in sunken floors including dismantling of old pipe complete all as specified and directed.
M & L for 50mm bore PVC (SWR) bends any radius with access door complete all as specified.
M & L for 50mm bore PVC (SWR) branch piece double, (Double Y) equal or unequal with access door complete all as specified.
M&L for PVC (SWR) Multi floor trap of 75mm of 75 mm dia outlet with 304 grade stainless steel square flat cut floor grating 125mm x 125mm with cockroach trap with or without hole as per requirement of site and as directed by Engineer-in- charge including jointing with solvent cement complete all as specified and as directed.
S & F in repairs 32mm bore Brass chromium plated bottle trap for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified
Taking down chowkats or frames with shutters (without taking off shutters from the frame) not exc 1.5 Sqm each complete all as specified and directed.
S & F factory made single rebated Wood Polymer Composite [WPC] solid door/ window / ceosetory windows & other Frames/ Chowkhats of size 65mm x 100mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms), fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with properties of termite / borer proof, water/ moisture proof and fire retardant, fixed in position complete all as specied and as directed.
S & F factory made single rebated Wood Polymer Composite [WPC] solid door/ window Frames/ Chowkhats of size 65mm x 150mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms), fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with properties of termite / borer proof, water/ moisture proof and fire retardant, fixed in position complete all as spefied and as directed upto G+3rd storey complete all as specified .
S&F wood plastic composite (WPC) factory made door shutter of 30 MM thickness made out of single pieces extruded WPC (wood plastic composite) profile with homogenous fine celluar structure made with plastic and wood powder having solid structure which is ECO friedndly with lacquar coated to give surface added strength & protectionand high grade UV resistance and with heat fire reardant will be hung and screws withdrawl strength 1800N (face) & 900 N (edge) minium compressive strength of 50N/MM2 E=900 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof water/moisture proof and fore retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star counter sunk S S screw of size 10mm dia and 100mm long all as per direction of Engr-in-Charge
M & L for Cutting holes in brick walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required [Depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall exc half brick not exc one brick thick]
S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) for window and ventilator shutters, side hung type without sash bars, with powder coating minimum 50 micron thick aluminium sections of weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays, hinges, handles, locks, etc complete all as specified
S & F Stainless steel Butt hinges, 100mm size medium weight complete all as specified and directed.
S & F extruded aluminium alloy handles fabricated type anodised of size 150mm complete all as directed.
S & F Aluminium anodised barrel Tower Bolt of size 200 mm size of extruded section complete all as specified and as directed.
S & F in repairs 15mm bore bib tap fancy type Chromium plated capstan head, screwed down, screwed for 15mm dia bore iron pipe complete all as specified and directed. [Make shall be Jaquar of Cat Part No. ACN-CHR-5041N or its equivalent]
S & F fancy type Chromium plated two way bib taps, cast copper alloy, with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule with flanges complete all as specified and directed. [Make shall be Jaquar of Cat Part No. KUP-35041PM or its equivalent]
S & F in repairs PVC connection 15mm size with PTMT nuts of length 600mm complete all as directed.
S & F in repairs Brass Chromium plated shower rose 125mm with or without swivel joints, including fixing to steel pipe or union complete all as directed
S & F in repairs brass chromium plated tubular towel rail, 20mm dia, 'D' type, 60cm long between flanges complete all as directed
S & F in repairs PVC body cabinet box mirror of size 350x450x100mm in PTMT alloy of approved pattern and design complete all as directed. [Make shall be PYAYAG of Cat Part No. 551 or its equivalent]
M & L for coloured joint free Non skid Ceramic tiles 7 to 8 mm thick light shade (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including 15mm thick screed bed in CM 1:6 including dismantling existing tiling including cement mortar bedding (but not backing) and removing rubbish of the premises complete all as specified and directed. Notes: [a] The colour/ shade/ design of tiles shall be as approved by GE. [b] The tile joint shall be kept as 3mm using tile spacers and masking tape shall be provided before applying of the epoxy grout and the surplus grout materials shall be thoroughly cleaned immediately.
M & L for coloured Glazed ceramic tiles of size 600x300x7-8mm thick as in vertical surfaces such as skirtings, dados and risers of steps, etc. set and jointed in neat cement slurry and pointed in white or colour cement to match with shade of tiles laid over and including 10mm thick backing coat in CM 1:4 including dismantling existing tiling including cement mortar bedding (but not backing) and removing rubbish of the premises complete all as specified and directed.
S & F in repairs Vitreous China Wash Down Water Closet [Pedestal pattern] of size 560x440x395mm or nearest size, White, including flush pipe of polyethylene of low or high density of PVC, 32mm dia, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. including brackets and connections to pipe and flush pipe including plastic water closet seat back closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and 'P' or 'S' trap including 10 Ltr capacity PVC valveless, syphonic action type flushing cistern, low level, white with inlet, ball valve, float and handle including brackets complete all as specified and as directed.
S & F in repairs soap dish holder fixed to plugs with chromium plated brass screws complete all as directed. [Make shall be Jaquar of Cat No. ACN-1131N or its equivalent]
S & F in repairs toilet Paper holder with flap Recessed Type (Stainless steel) fixed to wall with chromium plated brass screws complete all as specified and directed. [Make shall be Jaquar of Cat Part No. ACN-1153S or its equivalent]
S & F in repairs Vitreous China Ware Wash Hand Basin, White, Flat Back of size 550mm X 400mm, 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible Waste Pipe, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. complete all as specified and as directed.
S & F in repairs 15mm dia fancy type, CP Stop valve, screwed down, high pressure, with crutch or butterfly handle, concealed type with long shank and cup screwed both ends for iron pipe or for unions and fixed complete all as directed.
S & F in repairs 15 mm bore fancy type Chromium plated stop valves, cast copper alloy, with crutch or butterfly handle, screwed down high pressure for iron pipe complete all as specified and directed.
S & F in repairs vitreous china squatting pan of orissa pattern of size 580x440mm colour to match the existing surface with P or S trap front or back with integral foot rest including connection to trap and to flushing pipe anti syphon pipe etc complete all as specified and directed.
S & F in repairs 40mm dia PVC flexible waste pipe, 750mm long fixed to wash hand basin or sink complete all as directed
S & F Sawn neck Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with or with out lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as directed. [Make shall be JAQUAR of Cat No. CQT 23167B or its equivalent]
S & F Chromium plated Sawn cast copper alloy, mixer valve for Hot and Cold water connections with an arrangement for shower and one tap complete all as directed. [Make shall be JAQUAR or its equivalent]
S & F in repairs 15mm bore, Chromium plated Health faucet with 1.2m long Spirochrome flex & wall Hook complete all as directed.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement including dismantling existing SS railing complete all as directed
M & L for brick work in half brick thick walls using Fly Ash bricks straight or curved on plan to any radius built in Cement Mortar 1:4 including 2 Nos of 8mm dia bars at every fourth course of brick work complete all as specified and directed.
M & L for rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement including taking down cement plaster on brick work or stone masonry walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as directed.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc including removing rubbish complete all as specified and directed.
M & L for 18mm to 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and walls, etc and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over and including 15mm thick screed bed or bedding layer in Cement Mortar 1:6 including dismantling old stone slabs of any description complete all as specified and as directed. [Note: Single stone slab shall be used for entire Width and Length of Steps, Window Cills, Cooking Platform etc. and joints shall match with the flooring. The edges of treads shall be bull nosed / half rounded.]
M & L for RCC 1:2:4, type B-1 using 20mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Use and waste of steel formwork to soffits of suspended slabs rough finished surfaces of concrete flat complete all as specified and directed.
M & L for mild steel TMT bars 10mm dia and over, as in reinforcement cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including Mild Steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
Taking down cement plaster on brick work or stone masonry walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as directed.
Dismantling of detachable built in cup board in kitchen room of any description fixed with nails in any position complete all as directed
S & F HDPE / PVC loft water storage tank Rectangular shape with closed top 250 litres capacity, hoisted and fixed in position including 20mm dia PTMT ball valve including taking down old tank complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as directed
M & L for 18 mm thick factory made ready to install, non toxic, lead & cadmium free, single extruded, water proof, fire retardent and with excellent screw holding capacity , solid HDHMR board, one side decorative acrylic choice lamination and other side balancing white as in cupboard shutter, fixed to frame including liping the cut edges with same material finish complete all as specified and directed.
M & L for Decorative Acrylic laminate 1 mm thick (+5%) of surface finish, colour and pattern as approved, fixed by machine / heat pressed by approved adhesive as per manufacturers instructions complete all as directed
S & F in repairs stainless steel basket of size 475mmx500mmx100mm of grade SS-304 with external width 475mm as in kitchen drawers (for Cuttlery basket, Cup and saucers etc) modular type made out of stainless steel 4mm dia wire at 30mm c/c and fixed to 18mm thick PVC board with 0.9mm thick decorative laminate approved shade fixed on both sides with all fixing accessories complete all as specified and directed.
S & F in repairs stainless steel basket of size 475mmx500mmx200mm of grade SS-304 with external width 475mm as in kitchen drawers (Plain wire basket) modular type made out of stainless steel 4mm dia wire at 30mm c/c and fixed to 18mm thick PVC board with 0.9mm thick decorative laminate approved shade fixed on both sides with all fixing accessories complete all as specified and directed.
S & F in repair stainless steel (manual type) sliding/telescopic channel of length 20" (500mm) with 3 Nos of holding ball of load carrying capacity 45-50 Kg of 202 grade steel, width 45mm including necessary fixing arrangement complete all as specified and directed.
S & F in repairs cold rolled nickel plated steel O crank soft closing concealed hinge (15-22mm) including necessary fixing arrangement to shutter complete all as specified and directed.
S & F in repairs stainless steel ventilator/ grill of size 100mmx100mm for cupboard shutter including necessary fixing arrangement to shutter complete all as specified and directed.
S & F in repairs stainless steel modular kitchen handle, 100mm long with necessary fixing arrangement complete all as specified and directed.
S & F in repairs Sink with drainage board made of stainless steel 1 mm thick (SS-304) kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915 mm x 460 mm bowl size 410 mm x 330 mm x 160 mm complete all specified and directed
Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 Sqm but not exc 4.0 Sqm each complete all as specified and directed.
S & F factory made uPVG white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+0.2mm). Window profile with hollow section with multi chamber. Frame (112mm x 60mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose.)
Cutting openings through walls built in cement mortar for door, window and other openings or enlarging existing openings, etc., or cutting out defective masonry for underpinning including providing, fixing and removing, shoring, cleaning and stacking stone and removing surplus to store and rubbish off the premises complete all as specified and directed
M & L for Forming jambs, etc., to openings for new work built in in Cement mortar 1:4 including cutting, toothings and properly bonding into old work, including facing and pointing (if necessary) to match existing work, complete all as directed
M & L for Making good under cills (or over arches, lintels and bressummers) including all pinning as necessary new work built in CM 1:4 complete all as directed
M & L for RCC 1:2:4, type B-1, using 20mm graded stone aggregate as in cast in lintels upto 1.5m span, copings, bed blocks for hold fasts, bed plates, roof kerbs and similar work including weathering, slightly rounded or chamfered angles and throating, as directed including necessary form work complete all as specified and directed.
S & F 4.8mm thick sheet glass, ordinary quality and glazing with oil putty fixed to aluminium windows in squares not exceeding 0.5 Sqm in each pane including hacking out old broken glass complete all as specified and directed.
S & F 4.8mm thick sheet glass, ordinary quality and glazing with oil putty fixed to aluminium / UPVC windows in squares exceeding 0.5 Sqm in each pane for fixing in UPVC windows complete all as specified and directed.
S & F anodised aluminium grill (anodised transperant or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design / pattern with approved standard section and fixed to the existing window frame with CP brass / stainless ateel screws @ 200mm c/c including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as directed by the Engineer-in-Charge.
Taking down shutters exc 1.0 Sqm but not exc 2.0 Sqm each complete all as specified and directed.
M & L for 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified
S & F mild steel work as in Bands, straps, hold fasts, stiffners for fencing posts, struts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M & L for Preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described, and treated with tar or coal tar black paint complete all as specified and directed
S & F 35mm thick, factory made Second Class Hard Wood, Glazed and Skeleton Shutters, open rebated and prepared to receive glass, gauze, etc., divided into squares and rebated sash bars any numbers, edges of framing plain, chamfered or round ed, fitted with cut beads for securing glass, etc., sizes of members of shutters as specified in SSR Part – I and fitted to Chowkats complete all as specified and as directed.
S & F in repairs Stainless steel Butt hinges, 100mm size medium weight complete all as specified and directed.
S & F 2nd class hardwood Small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours; articles n exc 200 Cu. Cm each complete all as directed.
S & F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staples complete all as specified and directed.
S & F in repairs stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staples complete all as specified and directed.
S & F Aluminium anodised barrel Tower Bolt of size 150 mm size of extruded section complete all as specified and as directed.
S & F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as directed.
S & F extruded aluminium alloy handles fabricated type anodised of size 100mm complete all as directed.
S & F mild steel framed work such as grills, grating, etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to FE 290, Gde E-165 complete all as specified and as directed
M & L for preparation of new or previously untreated steel surfaces of any description, not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
S & F 4.0mm thick sheet glass, ordinary quality and glazing with oil putty fixed to aluminium / UPVC windows in squares exceeding 0.5 Sqm in each pane for fixing in UPVC windows complete all as specified and directed.
S & F new night latch of size 100x67x26mm, 7 levers of make GODREJ or equivalent
S & F floor door stopper of aluminium body and tongue anodised with hand drawn steel spring fixed in flooroverall length of cover plate 150mm complete all as specified and as directed.
S & F Aluminium 'Double U' channels for sliding purpose of cupboard shutters complete all as directed
S & F Continuous (piano) hinges, Stainless steel, bright finish or electrogalvanised width of flap 30mm (when open)
S & F 18mm thick Plywood, grade BWR, type BB, fixed with fevicol and nails fixed to timber frame work complete all as specified
S & F 12mm thick Plywood, grade BWR, type BB, fixed with fevicol and nails fixed to timber frame work complete all as specified
S & F 0.9mm thick decorative laminate type-1 of surface finish, colour and pattern as approved fixed with approved adhesive complete all as directed
S & F Bearing rollers for sliding of dressing table glass shutters complete all as directed
S & F Magnetic catch PVC body 25 to 40mm size for cup board shutters complete all as directed
S & F Hasp and staple, 125mm size aluminium, including bolt to hinge plate and fixed with screws complete all as directed
S & F in repairs 1st class hard wood beads, straight (any size) for glazed or gauzed joinery, renewed including mitreds, etc complete all as directed.
M & L for Machine cut kota stone slab flooring 20 to 25mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including 15mm thick screed bed in CM 1:3 complete all as specified and directed.
S & F Machine cut kota stone slab 20 to 25mm thick as in vertical surfaces such as skirting, dado and pillars, etc laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including 10mm thick backing coat in CM 1:4 complete all as specified and directed.
Dismantling mild steel structural steel work of any description from any position complete all as specified and as directed
M & L for providing Glass dividing strips 3mm thick, 38mm wide insereted in position complete all as directed
M & L for Cement mortar skirting in two layers comprises of 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished with 5mm thick in CM 1:3 finished even and smooth with out using extra cement complete all as specified and directed.
M & L for 75mm thick, PCC 1:3:6, type C-2, using 40mm graded stone aggregate as in plinth protection laid to slope in panels including joints filled with mastic filling and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
S & F Rolled mild steel work as in Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. Including cleats, brackets, etc. conforming to Fe-410-W (Gde-E-250) quality-B Complete all as directed
S & F rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed
M & L for Cutting holes into or through cement concrete slabs, for embedding balusters of stair case, etc. reinforced or otherwise exc 100 Sqcm but not exc 250 Sqcm superficial are of work complete all as specified and directed
M & L for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
M & L for 100mm thick, PCC 1:4:8, type D-2, using 40mm graded stone aggregate as in sub base of floors, and finishing the surfaces complete all as specified and directed.
M & L for 100mm thick, PCC 1:2:4, type B-1, using 20mm graded stone aggregate as in flooring and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ for thickness of concrete slab 100mm complete all as directed
M & L for providing Precast RCC 1:2:4, Type B-1, using 20mm graded stone aggregate as in Landings, Cover Slabs [for manholes etc], Chullah Hoods, Chajjas, Water Troughs, Mangers, Shelves and similar articles with plain faces set in cement mortar 1:4 complete all as specified and as directed.
Supply and installation of non returnable packer 8mm dia and drill hole should be 10mm dia for epoxy grouting including necessary cleaning of holes in position including necessay form work and safety measures complete all as directed
M & L for providing grouting with MONOPOL & KP 250/HP250 injection grout for cracks caused by srtuctural destress such as shear cracks, flexural cracks, tensile cracks should be injected with low viscocity epoxy resin including necessay form work and safety measures complete all as directed
M& L for drilling and fixing PVC nozzles for cementitious polymeric grout in case it is noticed that the beams, columns or slab elements have honey combing inside after removal of loose concrete material, it is necessary to inject POLYMER MODIFIED CEMENT GROT in the honey combed areas. Same methodology is used to inject construction including necessay form work and safety measures complete all as directed
M& L for drilling holes in concrete with suitable equipment as approved in columns, beams, slabs, walls, etc to the required depth as directed by the Engineer-in-Charge to facilitate the anchoring of reinforcement bars into the core concrete, including working platforms, equipmemnt, machines, skilled manpower, etc complete all as directed.
M & L for surface prepartion on concrete shall be free from dust, loose materials, surface contamination and materials which reduce bond or prevent suction or wettting by repair materials. Delaminated, weak, damaged and deteriorated concrete adhere necessary sound concrete shall be removed by suitable means. Substrate shall be saturated surface dry (SSD) with no standing water. Rusting, scales, motor concrete, dust and other loose materials on Steel reinforcement shall be removed by blast cleaning or other means of mechanical abrasion and the reinforcement shall be fully exposed and then apply a cement based epoxymodified three-component anti corrosive coating and bonding for rebar corrosion protection system complete all as directed
Supply & providing extra reinforcement at the area where corrosion has gone above 25% with proper over lapping and fixing using welding or lapping or dowel or anchoring system and placing in position at all hights & depths of high strength deformed weldable quality reinforcement bars of grade Fe-415 or Fe-500 higher grade conforming to IS:1786 (latest version) cutting, bending, welding to required shape and length binding with 16 SWG black soft annealed binding wire welding if required to form a rigid cage and placing with proper cover block, supports, chairs, spacers complete all as directed. [Note: No extra payment will be admissible if reinforcement provided is of higher grade]
M & L for rendering 10mm thick in CM 1:3 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement complete all as directed.
M & L for providing water proofing membrane for columns where Jacketing done Dekguard PU two coats on the repaied concrete surface including necessay form work and safety measures complete all as directed
Excavation in trenches not exc 1.5m wide and depth for foundations, laying of cables, pipe etc n.exc 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as directed
M & L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. (Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.)
Removing excavated material /soil to a distance exc 5 Km but not exceeding 15 Km and depositing where directed complete all as specified and directed
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel [½ round or ¾ section] in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required for 100 mm dia of pipe complete all as specified and as directed.
M & L for concrete bed to drain pipes of size 150 mm bore packing under and haunching against the sides of pipes after they are laid and tested in cement concrete, Type C2, 1:3:6, using 40mm graded stone aggregate complete all as specified and as directed.
Removing the retrieved building materials out side MD land to a distance upto 15.00 Km complete all as specified and as directed by Engineer-in-Charge.
M&L for applying food grade epoxy coating treatment to water tank on inside surface after proper surface preparation carry out cementitious injectionb grouting at leakage points using plasticized expansive grout admixiture treatment of construction joints using polymer modified mortar prepared by using SBR Latex screed modifier cum bonding agent application of polymer modified vatta/fillet at floor-wall grout application of one coat of epoxy/PU primer and two coats of solvent free food gradeepoxy resin coating @ 200 microns DFT IN 2 coats etc complete including all tools and tackless as per manufacturer's specification food grade epoxy coating shall be having elongation 100% adhesive bond strength b- >1 Mpa Pot lift of 30 min @ 30 C and cured film shall be non toxic and shall meets the requirements of IS:9833:1981. Note The contractor shall furinished 10 years warrant for hthe coating application shall be carried out by approved applicator of manufacture and as per recommended by manufacturer. (Actual applied area of epoxy coating shall be measured for payment.)
Providing and applying two part acrylic polymer modified cementitoius elastomeric waterproof caoting having minium 1 N/mm2 tensil strength at minium 1.5mm thickness DFT and shall cover 2.2Kg/Sqm. The coating shall have an elongation of a minium 0. 80% when tested as per ASTM D412 resisting S bars hydrostatic pressure as per DIN 1048 & having crack bridging ability of up to 2mm through surface preparation by mechanical means to level and plain the surface of walls & floors of the toilet areas all cracks and crevices to filled and made good to receive waterproofing coating treatment the coating shall cover all the floor area the wet area ( Toilet) and be applied over on to the of verticall walls for a hight of 4 feet above the floor the periphery of the toilet floor shall be additionally reinforced with an extra third coat of the coating with a fiber band sandwhiched between the first and the second coat which shall also done around protrusions )pipes) for plumbing purpos the last coat when by approved applicator of manufacture and as per recommended by manufacturer. (Actual applied area of epoxy coating shall be measured for payments all as specified and as directed )
M&L preparing new steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of aluminum paint over a coat red oxide zinc chrome primer
M&L for following :- (a) Removing plaster & finishes all around the coloumn slabs & beams ( on all four sides description of cloumn to full hight three sidescription of beam to entire span bottom of alab to area as directed). (b) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible). (c) Removal of cover concrete with under cutting of up to a depth of 20mm beyond reinfocrement around foll circumference & full length of bar where directed. ( concrete shall be stripped to an extent concrete substrate is exposed). (d) Cleaning exposed concrete substarte by using water jet. (e) Removing visible rust along the length og reinforcement using hand tools as approved.the Engr-in-charge may order sand blasting if rust is approved). (f) Any other work as directed by Engr-in-chagre to present clean surface for determination of type of repair to be carried out complete all as specified and directed. (g) Quoted rate is deemed to be inclusive for use and remeoval of formwork as required
M&L for providing rust proof/anti corrosive treatment to bars :- (a) Clenaing of all exposed bars (new & old) around. (b) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufacture. (c) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars alround new & old as recommended by the manufacture. Note :- Anti corrosive treatment shall be continuous espcially in the regions where pitting imperfections etc were present on the surfces of the bars. it is important that the rear portions of re bars ( those towards the concrete substrate) should not be left without coating including use and removal of formwork as required
M & L for providing PMM (Polymer Modified cementitious Mortar 30mm thick as under:- (a) Dry sub strate surface and free of debris & dust (b) Appying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible ( in case pin holes are still visilbe after a coat a second coat shall be applied to ensure absence of pin holes). (c) Immediately after application of exopy bond as above apply PMM (polymer modified cementiitous mortar) of 30mm thickness. (d) PMM surface to bemoist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed. (e) Quoted rate is deemed to be inclusive for use and remeoval of formwork as required
M & L for providing PMM (Polymer Modified cementitious Mortar 40mm thick as under:- (a) Dry sub strate surface and free of debris & dust (b) Appying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible ( in case pin holes are still visilbe after a coat a second coat shall be applied to ensure absence of pin holes). (c) Immediately after application of exopy bond as above apply PMM (polymer modified cementiitous mortar) of 30mm thickness. (d) PMM surface to bemoist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed. (e) Quoted rate is deemed to be inclusive for use and remeoval of formwork as required
M & L for repair to cracks in structural members as under:- i) Opening of crack by making a 'V' notch/groove of size 12mm x 12mm over the entire length of the crack as identified by the Engr-in-charge. (ii) Cleaning 'v' notch/groove of all dust/debris/loose material (iii) Drilling hole of 16mm dia and about 40mm deep along the length of crack @ (300 mm c/c or thickness of structural member whichever is less) Note: In case length of crack is found less than 300 mm then min 2 holes shall be drilled. (iv) Inserting 12 mm dia flexible PVC one way injection nipple in the hole drilled above and fixing the nipple with the help of fast setting epoxy putty. (v) Seal the surface around the nipple and the area of crack between successive nipples polymer modified mortar to ensure that there is no leakage from any gap. (vi) Allow the polymer modified mortar to cure for 24 hours and ensure that firmly fixed in postion. (vii) Cleaning nipple one by one commencin from the top to bottom in case of column and one by one in alternate direction incase of beam/slab using blow compressed air followed by water injection. An Ensuring that there is no obstruction in free flow of grouting materials complete all as specified and directed. (viii) Injecting" resin with very low viscosity monomer by mixing resin and hardener in proportions recommended by manufacturer by using injection gun equipped with pressure gauge & valves for controlling of flow of compressed air & resin. Note: Pressure shall be in the range of 1-2 kg/sqm and shall be done in nipples one by one as per order recommended by manufacturer. Mixing of resin and hardenere shall be mixed in small quantities so as it is consumed with in 30 minutes. Before use mixer shall be stirred thoroughly. (ix) Allow entire effected surface to cure for 24 hours. (x) Cutting out projected parts of the nipple & seal the hole in the nipple with epoxy putty as recommended by manufacturer. (xi) Quoted rate is deemed to be inclusive for use and remeoval of formwork as required
M&L for Providing & Pouring Micro concreting M-40 grade :- (i) Dry concrete substrate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound concrete substrate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above pour Micro concreting M40 grade, Make: MasterEmaco S46T of BASF or equivalent FOSROC/SIKA using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc,. Adding of aggregates will be permitted only as per manufacturer's recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labour charges for mixing, pouring concrete, cost of tools, lead & lift of materials, transportation etc., to carry out the complete work complete all as specified and directed. Note: The cost of micro concrete M-40 grade & Epoxy bond coat is included in this item including use and removal of formwork.
M&L for Drilling & chemical anchoring of new rebars/stirrups :- (i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under:- 8 mm dia bar - drilling length 80 to 100 mm Note: Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar (Master flow 935 of BASF or equivalent FOSROC/SIKA) with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete. (The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item) and including use and removal of formwork
SCHEDULE 'A' PART-II [E/M Works]: M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area) 1100V grade drawn through and including PVC conduit of size 20mm dia medium grade including accessories fixed on wall/floor/roof, etc including provision of flush type metal GI boxes with modular cover plates, provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan point / Bell point controlled by one, one way switch including taking down old point wiring with fixtures and fittings complete all as specified and directed. [Note: Quoted rate is deemed to be inclusive for cutting through wall, chasing, pinning in making good to the disturbed surfaces whrever required]
All as per item No. 185 above but suitable for one light point controlled by two 02 way switches
All as per item No. 185 above but suitable for one 5/6 Amps socket outlet point controlled by one switch on the same board
All as per item No. 185 above but suitable for one 5/6 Amps socket outlet point controlled by one switch on independent board
All as per item No. 185 above but point wiring with PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 2.5 Sqmm (nominal area) suitable for one 15 Amps power point on independent board complete all as specified and directed.
All as per item No. 185 above but point wiring with PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 4.0 Sqmm (nominal area) suitable for power point on independent board complete all as specified and directed. [For AC & Cooler points]
S & F Telephone jack deluxe with shutter line with metal box
S & F Computer / LAN Jack Cat 6 with shutter with metal box
S & F TV Socket outlet with metal box
S & F modular switch single pole, 1 way, 6 Amps, 1 module
S & F modular switch single pole, 2 way, 6 Amps, 1 module
S & F modular bell push flush type 6 Amps, one way, 1 module
S & F modular switch 1 way, 16 Amps, 1 module single pole
S & F modular socket outlet, 6 Amps, 2/3 pin combined 2 module
S & F modular socket outlet, 6/16 Amps, 2/3 pin combined 2 module
S & F modular electronic fan regulator, socket type, 2 module complete all as specified and directed.
S & F ceiling rose, 3 terminals, PVC/ polycarbonate, isolated body complete all as specified and directed
S & F Calling bell, ding dong AC, 230 Volts, single pole
S & F in repairs 4 module PVC SRCD with two pin and earth plug and socket complete with one MCB, SP, 20 Amps, 240 volts, 10 KA complete all as specified and directed.
M & L for sub main wiring with 2 runs of single core 1100 volts grade, PVC insulated, unsheathed, FRLS copper conductor cable of size 2.5 Sqmm, drawn through and including 20mm dia concealed PVC conduit and conduit accessories including provision of 1 run of 2.5 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring complete all as specified and directed. [NOTE: 3 runs of 2.5 Sqmm copper wire and 1 run of PVC conduit shall be measured as one unit length.]
M & L for sub main wiring with 2 runs of single core 1100 volts grade, PVC insulated, unsheathed, FRLS copper conductor cable of size 4.0 Sqmm, drawn through and including 20mm dia concealed PVC conduit and conduit accessories including provision of 1 run of 4.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring complete all as specified and directed. [NOTE: 3 runs of 4.0 Sqmm copper wire and 1 run of PVC conduit shall be measured as one unit length.]
S & F in repairs MCB DB, TPN, 4 Way, 415 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wall complete all as specified and as directed.
S & F in repairs MCB, TPN, 63 Amps, 415 Volts, 10 KA, C series
S & F in repairs MCB DB, SPN, 8 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wall complete all as specified and as directed.
S & F in repairs MCB, SPN, 32 Amps, 240 Volts, 10 KA, C series
S & F in repairs MCB, SP 6 to 32 Amps, 240 Volts, 10 KA, C series
S & F in repairs LED tube light fittings, retro bar professional WH 5700K to 6200K, 1x20 W of cool white comprising of batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs LED tube light fittings, mirror type with high out put diffuser 2 feet long of 10 Watts of cool white wall mounted batten with all accessories internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs Building Security light LED type of minimum 3500 Lumens new generation energy saving & environmental friendly long life made up of Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 32mm dia GI light grade pipe of 1.5m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs LED Bulb, 9 Watts Lumen > 900, Luminous afficacy >100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra, IP 20 rated, fixed in and including Lamp holder, PVC/Polycarbonate type with back plate complete all as directed
S & F in repairs stationary louvers for exhaust fans of 300mm sweep made out of powder coated aluminium anodised sheet of minimum 1mm thick with non removable blades fixed permanently at 450 angle for protection from rain including providing aluminium wire mesh forr bird protection complete all as directed
S & F in repairs 20mm dia Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. Complete all as directed
Taking down existing Ceiling Fan of any description and capacity from its original position and refixing the same in position after repairs to buildings after carrying out necessary servicing, cleaning, greasing including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of suitable size, replacement of minor spares such as capacitor, canopy, cotter pin, rubber bushes, nuts & bolts, washers and spray painting with one coat of synthetic enamel paint of approved colour duly filling the cavities with filler complete all as specified and as directed.
Taking down existing Exhaust Fan of any description and capacity from its original position and refixing the same in position after repairs to buildings after carrying out necessary servicing, cleaning, greasing including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of suitable size, replacement of minor spares and spray painting with one coat of synthetic enamel paint of approved colour duly filling the cavities with filler complete all as specified and as directed.
M & L for Overhauling of Geysers of 25 Lit capacity of any make by dismantling geyser by removing from its original position by disconnecting electric connection, inlet & outlet water supply connections, detecting the leakage by removing the copper vessel and rectifying by soldering, testing, refixing in position including spray painting with two coats of synthetic enamel paint over a coat of zinc chrome primer after filling cavities with filler and replacement of minor spares such as heating element, thermostat, Plug top, indication lamp, PVC connection for Hot & Cold water, etc complete all as directed
Supply and Laying LT XLPE insulated, PVC sheathed, bedded, galvanised steel strip or wire armoured, heavy duty, electric power cables of size 4 core 16 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct / road crossing / fixed on poles / walls and connecting up with suitable glands, lugs, nuts and bolts and testing on completion including taking out old unserviceable cable complete all as specified and directed by the Engineer-in-Charge.
Taking down existing Energy meter three phase from its original position and refixing the same in position after repairs to buildings after carrying out necessary servicing, cleaning including making up connections complete all as specified and as directed.
Taking down existing smoke detector / manual call point / control panel from its original position and refixing the same in position after repairs to buildings and finishes after carrying out necessary cleaning including making up connections complete all as specified and as directed.
Taking down existing 2 core 1.5 Sqmm control cable from its original position and refixing the same in position after repairs to buildings and finishes complete all as specified and as directed.
Earthing complete with Galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected with GI earth strip 32x6mm as earth lead by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including taking out old perished earth pits complete all as directed. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS angle iron frame 40x40x6mm, RCC 1:2:4 type B-1 cover 40mm thick with 8mm dia steel reinforcement bars at 150mm c/c both ways, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 40mm dia, earthing lead upto 7.5m including providing charcoal or coke and common salt in alternate layers of 15cm compacted thickness all around the electrode complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.]
S & F in repairs 4mm dia galvanised iron Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as directed
S & F in repairs Aluminium strip 25 x 3.15mm for lightning conductor with saddles and fixing screws etc. for roof conductors and down conductors laid in trench/ floor including necessary clamps, nuts, bolts, and hylem sheet block complete all as directed
S & F in repairs Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
S & F Test terminal box of size 175x150x100mm made out of 2mm thick hot dip galvanised sheet drilled and screwed including 4 Nos 25mm long hexagonal head screwed with test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw complete all as directed
S & F integral LED aviation light of Min 10 Watts single head type comprising of aluminium housing with polycarbonate enclosure complete all as directed
S & F 3 core copper conductor cable of size 2.5 Sqmm complete all as directed Notes: [i] Tenderers to note that scope of work under some of the above items shall be executed in the buildings of varying heights upto 11 floors. Provision of necessary scaffolding & ensuring safety measures as directed by the GE are deemed to be included in the unit rates quoted by the Contractor. Quoted rates are also include for Washing floors, cleaning glass, joinery, electric fittings, wiring, etc. of drops and splashes and leaving premise, clean and tidy. Tenderers are advised to visit the site of work prior to submit their bid online. No extra claim whatsoever on account of height of buildings is admissible at later stage. [ii] All the debris obtained from demolition / dismantling and taking down shall be removed from the site and disposed out side MD land upto a distance of 15 Km. Tenderers quoted rates under relevant items are deemed to include for this aspect also and nothing extra shall be paid in this regard.
MURALI KRISHNA ASSOCIATES (BID ID -3476489)
VIJAY VINAYAKA INFRA (BID ID -3476376)
S A R CONSTRUCTIONS (BID ID -3476580)
Mahamaruti Constructions (BID ID -3476255)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.65 MB
BOQ_822327.xls
BOQ • 0.48 MB
82602tender.pdf
Tender Documents • 1.78 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .