| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-Finance NOT AVAILABLE | L1 | Accepted-Finance Eligible | |
| 2 | L2₹2.0 L+₹680 (0.34%)Rejected-Finance | L2 | Rejected-Finance Not Eligible | |
| 3 | L3₹2.1 L+₹9,720 (4.89%)Rejected-Finance | L3 | Rejected-Finance Not Eligible |
| Sl No | Description | Qty | Unit | Roop chand L2 | RAMESH KUMAR L1 | Shyam Lal Sharma L3 |
|---|---|---|---|---|---|---|
| 1.00 | Providig and fixing of 3.00HP Submersible pump set (water field) of standard make such as Kirlosker/KSB/Crompton/Sabar/BS /Angel/Falcon confirming to ISI Code 8034-1976 with up to date ammenments. the pump set should be capable of handling 70 meter head with (+)10% (-)15% head range and it should be operational with 240 V single phase AC supply. Discharge should be 1.0 liter/ sec. in all leads and lifts.
Total Head = 150 Meter , Discharge = 2.00 LPS | 2 | Per Set | 36,500 ₹73,000 Lowest | 37,000 ₹74,000 | 36,500 ₹73,000 Lowest |
| 2.00 | Providing and fixing of starter (direct on line) of 3.00 HP of standard make such as L&T/MEI/Havels/AVON/Crompton/ Asian for above pump set with suitable capacity installed on a wooden switch board fixed on a wall capable of mounting a voltameter 0 to 300 volts capacity and ampere meter of capacity 0 to 150 ampere of standard make as per the satisfaction of Engineer-in-charge. | 2 | Each | 8,600 ₹17,200 | 9,050 ₹18,100 | 8,500 ₹17,000 Lowest |
| 3.00 | Providing and fixing of water proof PVC Cable 3 core, 2.5 mm as per IS-674-Part-II-1964 suitable for above pump set from starter to pump set subject to the approval of HPSEB authority as per the satisfaction of Engineer-in-charge. | 100 | Each | 300 ₹30,000 Lowest | 300 ₹30,000 Lowest | 320 ₹32,000 |
| 4.00 | Providing and fixing MS sheet box size (0.60x0.30x0.90mm fabrocated with angle irong of four legs mounted in cement concrete 1:3:6 for electric metred starter switch and other accessories with locking arrangement complete. | 2 | Each | 13,100 ₹26,200 | 11,000 ₹22,000 Lowest | 13,000 ₹26,000 |
| 5.00Providing laying , jointing and fixing 3 layer PPR(Polypropylene random copolymer) pipe UV stabilized and antimicrobial fusion welde, having thermal stability for hot and cold water supply including all PPR plain polypropylene random fittings complete to ISI 15801-2010 and testing of joint complete in all leads and lifts as per the direction of Engineer in charge ( Earth work in trenches will be extra) | ||||||
| 5.01 | a) 40mm dia | 86 | Rmt | 450 ₹38,700 Lowest | 500 ₹43,000 | 480 ₹41,280 |
| 6.00 | Providing and fixing MS Clamps to hold the pump set in the bore well including required bolt and nuts complete in all respect as per entire satisfaction of Engineer-in-charge. | 2 | Each | 650 ₹1,300 | 510 ₹1,020 Lowest | 680 ₹1,360 |
| 7.00 | Providing and fixing steel wire rope 6mm Thick for holding the column assembly and pump set in bore well to avoid falling of assembly and pum set in bore well including comlete arrangement of fastening etc.complete in all respect as per the direction of Engineer-In.Charge. | 120 | Rmt | 110 ₹13,200 | 90 ₹10,800 Lowest | 150 ₹18,000 |
Tender Value
₹2.0 L
EMD Value
₹4,000
Closing Date
18 Aug 2025, 5:00 pmClosed
Executive Engineer
Jal Shakti Division Kullu
SH Replacement of damaged submersible pump due to land slide above borewell near Jia ward No 4 on NH SDF 2024 1197
2025_HPIPH_111817_1
3817-67 Shatiban
Open Tender
Civil Works
Item Rate
60 days
Jia
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Executive Engineer
₹4,000
10 Sept 2025
7 Aug 2025
19 Aug 2025
8 Aug 2025
18 Aug 2025
8 Aug 2025
Amount
Providig and fixing of 3.00HP Submersible pump set (water field) of standard make such as Kirlosker/KSB/Crompton/Sabar/BS /Angel/Falcon confirming to ISI Code 8034-1976 with up to date ammenments. the pump set should be capable of handling 70 meter head with (+)10% (-)15% head range and it should be operational with 240 V single phase AC supply. Discharge should be 1.0 liter/ sec. in all leads and lifts. Total Head = 150 Meter , Discharge = 2.00 LPS
Providing and fixing of starter (direct on line) of 3.00 HP of standard make such as L&T/MEI/Havels/AVON/Crompton/ Asian for above pump set with suitable capacity installed on a wooden switch board fixed on a wall capable of mounting a voltameter 0 to 300 volts capacity and ampere meter of capacity 0 to 150 ampere of standard make as per the satisfaction of Engineer-in-charge.
Providing and fixing of water proof PVC Cable 3 core, 2.5 mm as per IS-674-Part-II-1964 suitable for above pump set from starter to pump set subject to the approval of HPSEB authority as per the satisfaction of Engineer-in-charge.
Providing and fixing MS sheet box size (0.60x0.30x0.90mm fabrocated with angle irong of four legs mounted in cement concrete 1:3:6 for electric metred starter switch and other accessories with locking arrangement complete.
Providing laying , jointing and fixing 3 layer PPR(Polypropylene random copolymer) pipe UV stabilized and antimicrobial fusion welde, having thermal stability for hot and cold water supply including all PPR plain polypropylene random fittings complete to ISI 15801-2010 and testing of joint complete in all leads and lifts as per the direction of Engineer in charge ( Earth work in trenches will be extra)
a) 40mm dia
Providing and fixing MS Clamps to hold the pump set in the bore well including required bolt and nuts complete in all respect as per entire satisfaction of Engineer-in-charge.
Providing and fixing steel wire rope 6mm Thick for holding the column assembly and pump set in bore well to avoid falling of assembly and pum set in bore well including comlete arrangement of fastening etc.complete in all respect as per the direction of Engineer-In.Charge.
Roop chand (BID ID -543670)
Shyam Lal Sharma (BID ID -543733)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .