Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC | ₹1.6 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.6 Cr+₹1.5 L (0.98%)Rejected-AOC | ₹1.6 Cr+₹1.5 L (0.98%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹1.6 Cr+₹1.6 L (1.00%)Rejected-Finance | ₹1.6 Cr+₹1.6 L (1.00%) | L3 | Rejected-Finance Quoted Higher Rate |
| 4 | L4₹1.6 Cr+₹3.6 L (2.25%)Rejected-Finance 00 BALITIKURI BALITIKURI NASKARPARA HOWRAH WEST BENGAL 711113 | HOWRAH | WEST BENGAL | 711113 | ₹1.6 Cr+₹3.6 L (2.25%) | L4 | Rejected-Finance Quoted Higher Rate |
| 5 | L5₹1.7 Cr+₹8.5 L (5.36%)Rejected-Finance | ₹1.7 Cr+₹8.5 L (5.36%) | L5 | Rejected-Finance Quoted Higher Rate |
Tender Value
Refer Docs
EMD Value
₹5.6 L
Closing Date
6 Jan 2021, 2:00 pmClosed
Superintending Engineer, K. H.E.C., P.W.D.
Superintending Engineer, K. H.E.C., P.W.D.
Construction of proposed for TERTIARY CARE CANCER CENTRE at College of Medicine Sagore Dutta Hospital Kamarhati Kolkata External Electrical Installation Works including SITC of 2000KVA Sub Station
2020_WBPWD_308114_1
WBPWD/SEKHEC/KNHED/NIQ11/20-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
180 days
TERTIARY CARE CANCER CENTRE
Please refer Tender documents.
5 documents required · 5 mandatory
₹5.6 L
Superintending Engineer, K.H.E.C., P.W.D.
18 Feb 2021
8 Dec 2020
8 Jan 2021
9 Dec 2020
6 Jan 2021
18 Dec 2020
14 Dec 2020
Amount
SUB-HEAD - SUB STATION WORK
SITC OF 6.6 KV VCB PANEL & 6/0.415 KV TRANSFORMERS & MAIN PANEL
Supply & Delivery Indoor-type, floor mounted,metal clad, single tier, fully compartmentalized,free standing, 6.6 kV VCB Panel with 3 Nos VCBs (1 Incomer + 2 Outgoing), totally enclosed and fully interlocked , horizontal drawout, horizontal / vertical isolation type breaker as per IS 13118, as ammended upto date and as per detail specification attached ( uploaded in the specification section) , suitable for use on 6 KV, 3 Phase,50 Hz AC supply to energise TWO 1000KVA Dry Type Transformers. [ Make : ABB / Siemens / CGL].
Supply & Delivery of Cast Resin Dry Type 6KV/415V 1000 KVA, 3 Phase,50Hz, Dyn11,copper wound, Class F insulation associated with winding temperature indicator/controller,having cable end box in the HV & LV sides and all accessories and conforming to IS 11171-1985 & IS - 2026 with latest modification (if any) & CBIP Specification and as per detail specification attached ( uploaded in the specification section) [ Make: ABB/Voltamp ( Vadodara)/CGL ].
Installation & commissioning of the above 6.6 kV VCB Panel with P.T & all the accessories, incl. carriage, by placing in position, assembling, lining up, levelling and checking all instruments, relays, correctly set according to requirement.
Installation & commissioning of 6 KV/ 415 volt, 1000 KVA distribution transformer incl. carriage to the substation building within a lead of 30mtr by placing in position and fixing after leveling fitting all components, connecting, checking & set of all instrument, relays according to requirement as instructed by the EIC incl. S&F base channels etc.
SITC of floor mounted Indoor type extensible cubical MV switchboard suitable for use in 3rd party SCADA compatible earthernet network , fabricated by CPRI approved panel maker having compartmentalized design, fabricated out of 14 SWG ( 2.0 mm ) nominal thickness CRCA sheet steel,front and back openable, hinged, single shuttered, with incoming ACBs & Outgoing ACB/MCBS/SFU and all accessories as per size, design & drawing to be approved by EIC and conforming to IS with latest modification and as per detail specification attached ( As in the specification section) [ I/C : ACB 1600A(min-65KA)-2 nos, B/C - ACB 1600A(min-65KA) , O/G SEC-1 : ACB 800A, 65kA - 3 nos (1 no for Riser 1 , 1 no for LINAC, 1 no spare) ( MCCB 36kA: 400A - 3 nos (1 no forCT Scan + MRI, 1 no spare, 1 no for capacitor bank), 125A - 1 nos (Pump Room) , 63A - 2 nos (1 no Sub station, 1 no Compound Light] O/G SEC-2 : ACB 800A,65kA - 3 nos (1 no for Riser -II , 1 no for AC, 1spare) ( MCCB36kA : 400A - 2 nos ( 1 no. for capacitor bank , 1 no spare), MCCB - 250A - 2 nos (Fire Fighting & Spare) ], 125A - 1 nos (Spare) , 63A - 1 nos (Spare]
Supply & Drawing 1.1 KV Grade 7 Core 1.5 sq.mm PVC Armoured Copper Cable from Transformer WT relay to VCB WT relay for Power & Control Supply as per direction of EIC
Supply & delivery, Installation, Testing & Commissioning of AUTOMATIC POWER FACTOR CORRECTION PANEL (300 KVAR) and conforming to IS with latest modification and as per detail specification attached ( uploaded in the specification section) to be installed at HT Substation Building.
Making testing arrangement and submitting the test report for high voltage testing of specified voltage incl. checking & testing of all HT / LT equipments by authorized firm of Directorate of Electricity & commissioning the installation after obtaining the Approval of Directorate of Electricity.The scope shall be also included the necessary approval from Authority also.
Supply & fixing 75x45 mm "C" channel having length of 2 mtr. each channel incl. nuts, bolts and washer etc.
Submission of a Sub-station drawing (Computer autocad generated & printed in all sheet quarduplicate)showing H.T & LT cable duct single line power diagrams EI layout system equiment neutral earthing etc. enter plan as per direction and satisfication of E.IC.
SUB HEAD - HT/ LT CABLING IN SUBSTATION
Supplying of 6.6KV (UE) Grade XLPE Aluminium conductor, PVC sheathed, armoured cable conforming to IS 7098:1988/1554:1988/ 5831:1984/ 3961:1967/ 3975:1970/ 10810:1984 / 3975:1970 /8130:1984/ 3961:1967/ 10418:1982 / 10810:1984 as amended upto date, in respect of component materials and tests, and as per the approved makes list attached herewith, earthed system of following size.[ From Supplier HT Gear to Consumer HT Gear and to Transformer]. [ Make : As per approved make list]
3 Core x 300 Sq.mm
Laying of 1 No. 6.6/11KV (UE) Grade XLPE Aluminium conductor, PVC sheathed, armoured cable confirming to IS 7098, of earthed system of following size in the existing Masonary tranch as per GS.
3 Core x 300 Sq.mm 6.6KV/11KV XLPE HT cable
Making heatshrinkable joints indoor type to the ends of the following XLPE HT cable at the transformer end as well as at the VCB ends supplying with necy. jointing kits (Raycham), sockets, sleeves, anti-corrossive paste, wires, solders, jointing compounds, rubber sheets etc. incl. supplying of necy. tools & tackeles for crimping the end sockets, soldering irons & making of glands at the both end of the cable as per directions of EIC
3 Core x 300 Sq.mm 6.6KV/11KV XLPE HT cable
Supply & Delivery of 1.1 KV grade XLPE/PVC insulated. PVC sheathed, steel Armoured Al. conductor Cable of the following size, and conforming to IS: 7098(Part-I):1988/1554(Part-I):1988/ 5831:1984/ 3961(Part-I):1967/ 3975:1970/ 10810:1984 / 3975:1970 /8130:1984/ 3961:1967/ 10418:1982 / 10810:1984 as amended upto date, in respect of component materials and tests, and as per the approved makes list attached herewith.
4 Core 400 Sq.mm [from Transformer to Main Panel]
Single Core 400 Sq.mm [from Main Panel to Rising Main]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
4 Core 400 Sq.mm
Single Core 400 Sq.mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
4 Core 400 Sq.mm
Single Core 400 Sq.mm
Laying of the following size of the cable as per requirement and as per direction of the EIC.
4 Core 400 Sq.mm
Single Core 400 Sq.mm
S&F 50X6 Angle suport for cable trench and cable including clamping
SUB-HEAD - EARTHING
S& laying 240 sq. mm. single core multistrand PVC insulated flexible Cu wire in suitable size of PVC flexible pipe (reinforced) from nutral earth busbar to transformer nutral point as required (for Transformer /Generator neutral earthing) including compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry & Socketing both sides by Cu Socket. [ 4 run x 10 mtrs x 2 set = 80 mtrs]
Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level as per detail specification attached ( uploaded in the specification section) [ FOR TRANSFORMER NEUTRAL AND DG SET EARTHING ]
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe
Extra treatment of soil by using salt & charcoal for plate electrode as to G.S.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 65 mm x 8 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Supplying & fixing earth busbar of Copper flat 65 mm x 10 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with brass bolts, nuts, washers, spacing insulators etc. as required
Insulating the 65 x 8 mm M.S. flat & 65 x 10 mm Copper flat incl. S&F black heat shrink PVC sleeves etc. The PVC tube sleeve to be inserted on the GI flat and heat shrinked by heating apparatus by skilled technician carefully without damaging the PVC sleeve as per direction of the EIC
SUB HEAD - ( SAFETY EQUIPMENT )
Providing & fixing danger plates made of mild steel at least 2mm thick & vitreous enameled white on both sides & with inscription in signal red colour on front side as required.
a) High Voltage - size 250mm x 200mm
b) Medium Voltage - size 200mm x 150mm
Providing and fixing carbon dioxide (CO2) type fire extinguishers conforming to IS 15222-2002 and cylinders fully charged of following capacity(4.5 Kg ) [Make - Fire Shield/ Ceasefire]
Excavation of soil ( Soft Soil) for installation of Earth Electrode and filling & ramming.
Supply and fixing of foam fire extinguishers conforming to IS 4989-2006, Portable type 9 lit capacity hanged on wall with bracket complete as required. [Make - Fire Shield/ Ceasefire]
Supply and fixing safety instruction chart in word duly framed with 5mm thick glass as required (approx. Front area 1.20 sq.mt.)
Providing of set of 4 nos. 9.5 litre capacity GI bucket painted in post office red colour with prior coat of red-oxide paint and written with white paint 'FIRE' and mounted on MS angle iron frame with bracket and suitable base of appropriate size & capacity I/c filling sand etc.
Providing First Aid Box as approved by St. John Ambulance Brigade / Indian Red Cross conforming to IS 13115-1991.
Supply and fixing shock treatment chart duly mounted on a wooden frame with 5mm thick glass as reqd. (approximate front area 1.20 sq.metre).
Providing of rubber mat 2 mtrs Length x 1 m. wide and 12mm thick to withstand 15 KV dielectric strength as per IS 15652-2006.
Providing of rubber mat 2 mtrs Length x 1 m. wide and 6mm thick to with stand 3.3 KV dielectric strength as per IS 15652-2006.
S&F 11kv grade Rubber Hand Gloves.
S/F of 860 mm wide and 8 mm thick M.S checker plate including painting for covering the trench.
SUB HEAD : DISTRIBUTION WIRING
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
6-32A SP MCB
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.
40 A DP Isolator
63A FP Isolator
Supply & Delivery of 1.1 KV grade XLPE/PVC insulated. PVC sheathed, steel Armoured Al. conductor Cable of the following size, and conforming to IS: 7098(Part-I):1988/1554(Part-I):1988/ 5831:1984/ 3961(Part-I):1967/ 3975:1970/ 10810:1984 / 3975:1970 /8130:1984/ 3961:1967/ 10418:1982 / 10810:1984 as amended upto date, in respect of component materials and tests, and as per the approved makes list attached herewith.
4 Core 25 Sq.mm
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish
From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
4 Core 25 Sq.mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
4 Core 25 Sq.mm
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (As per approved make list) partly in 20mm size PVC rigid conduit 'FR' (As per approved make list) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed
Average run 8 mtr
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC (As per approved make list) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish
On Board
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the 13/19/25/32/40/50 mm dia 3mm thick polythene pipe and GI fish wire embeded in wall and making necy. connection as required and mending good damages to original finish.
3 x 22/0.3 (1.5 sqmm)
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC
Finishing of the PVC insulated Cu wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
1.5 sqmm cu wire
2.5 sqmm cu wire
4 sqmm cu wire
6 sqmm cu wire
S&D of 240V Single industrial box (thick ness of box should not be less than 22 SWG) type luminaire with CRCA body (Make :- Philips -TMC 501P 1xT-LED22W P3241/ Equivalent product of Crompton/Wipro having similar specification in all respect). incl S&D 1x 18 watts 4 ft LED tube lamp (Make:- Philips, Cat - Mas LED tube 1200 mm 18W865 T8 I 2100 Lumen PC Body/ Equivalent product of Crompton/Wipro having similar specification in all respect)
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type 125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Supply & Fixing 240 V, 2 nos 6A, plug socket with separate 2 nos 6 A Piano key type switch on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board complete with 3 nos suitable size copper bar with holes (for Ph,N & E) fixied on bakelite/Hard rubber insulator over the MS welded chairs and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board complete with 3 nos suitable size copper bar with holes (for Ph,N & E) fixied on bakelite/Hard rubber insulator over the MS welded chairs and bakelite/ perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & delivery of 250 volt. 48" (1200 mm) sweep A.C. Ceiling fan having safety wire , P2 type capacitor incl. down rod, canopy & fan blades etc. complete with all accessories (without regulator) & having Double Ball Bearing & Low Noise. [Make - Crompton HB+ or HS+/Orient Energy star/Usha Striker/Make of Similar specification As per Approved Make List]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Supply & Fixing Socket type fan regulator (Step type) on suitable chair in sheet metal box with cover incl. making housing for regulator knob by cutting cover & making necy. connections etc. as per direction of the EIC.
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)
S & F 240 V. 300 mm. (12") Dia of A.C. Exhaust Fan (EPC Electrical Pvt. Ltd. - Heavy Duty) incl. cutting hole on wall, S&FGI sheet (20 SWG) metal cowl with MS flat iron frame and GI wire mesh on wall with necy. bolts, nuts, (6mm diax62mm long), washers etc. as per direction of the EIC.
Supply of Exhaust fans size 9"( 225mm ) Speed 1370 RPM complete with all accessories. (Make - E.P.C. Electrical Pvt. Ltd., Heavy Duty)
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
40 mm dia
SUB HEAD : Fittings & Fixture
Supply & delivery 250 volt. 16" metal body & Blade wall Bracket Fan complete with all accessories.
Supply & delivery of 250 volt. 56" (1400 mm) sweep A.C. Ceiling fan having safety wire , P2 type capacitor incl. down rod, canopy & fan blades etc. complete with all accessories (without regulator) & having Double Ball Bearing & Low Noise. [Make: Crompton Aura, / Orient Gratia/Make of Similar specification as per Approved Make List]
Supply & delivery of 250 volt. 48" (1200 mm) sweep A.C. Ceiling fan having safety wire , P2 type capacitor incl. down rod, canopy & fan blades etc. complete with all accessories (without regulator) & having Double Ball Bearing & Low Noise. [Make - Crompton HB+ or HS+/Orient Energy star/Usha Striker/Make of Similar specification As per Approved Make List]
S&D of 240V Single industrial box (thick ness of box should not be less than 22 SWG) type luminaire with CRCA body (Make :- Philips -TMC 501P 1xT-LED22W P3241/ Equivalent product of Crompton/Wipro having similar specification in all respect). incl S&D 1x 18 watts 4 ft LED tube lamp (Make:- Philips, Cat - Mas LED tube 1200 mm 18W865 T8 I 2100 Lumen PC Body/ Equivalent product of Crompton/Wipro having similar specification in all respect)
S&D of 240V Twin industrial box (thick ness of box should not be less than 22 SWG) type luminaire with CRCA body (Make :- Philips -TMC 501P 2xT-LED22W P3241/ Equivalent product of Crompton/Wipro having similar specification in all respect). incl S&D 2x 18 watts 4 ft LED tube lamp (Make:- Philips, Cat - Mas LED tube 1200 mm 18W865 T8 I 2100 Lumen PC Body/ Equivalent product of Crompton/Wipro having similar specification in all respect)
S& D of 230V 15watt LED recessed luminaries circular type corresponding (make-Philips cat no-DN194BED15S-6500PSU WH S1/Equavalent product of Crompton/Wipro having similar specification in all respect) for false cellig as per direction of EIC.
S& Dof 230V 120 watt LED recessed luminarieshighbay light fittings (make-Philips cat no-LED 145SCWPSUGRFGWBXTFCLV1 /Equavalent product of Crompton/Wipro having similar specification in all respect) on surface ceiling as per direction of EIC.
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board
SUB HEAD : LIGHTNING CONDUCTOR
S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. complete duly grouted on the parapet etc. in CC mortar ( 4:2:1)
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works:
Length upto 0.5 Mtr
Length above 0.5 Mtr
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required
Making soldered joints between conductors and down pipes/other metallic objects for 14 SWG GI (Hot Dip) wire including supply of necessary 4 SWG GI (Hot Dip) wire, jointing materials and painting with 2 (two) coats of bituminous paint
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Extra for treatment of soil by using salt & charcoal or coke for plate electrode
Connecting the equipments body to earth busbar incl. S & F 40 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc.
Supply & Installation of LED Sign Board
LED Signage: Designing, Fabrication, Supply, Installation, Testing & Commissioning of Outdoor LED Signage (Approximate Size:20' Length X 5' height) in English/ Bengali (letters given and approved by concerned department) for letters with following specifications
(a) The box for the signage will be fabricated in Aluminum Square tube of size 25 mm. X 25 mm. of 16 gauge complete with necessary priming and painting. The front of the box will be covered with 3 mm. thick Aluminium Composite Panel (ACP) sheets of the entire board. The board to be fixed in front of canopy by providing required support and Angle Bracing. The complete installation will be water, vermin and dust insulated and protected.
(b) Letter Description: Approx 9" x 5" size (or as per direction of the EIC as per actual requirement) of letters made of Aclrylic Sheet with male female attachment, on router cut ACP Sheet of front incl. all accessories as required.
(c) LED Illumination & Power Supply:High Bright, High Wave length closed type waterproof white LED modules (0.72 W or Higher) mounted on interior side of female part of letter with power wire running back to a central power area having required capacity Power Transformer of primary phase voltage 230 V and requir converter-filter to adequately drive the whole LED modules without Flicker.
(d )Internal Electrical Wiring will be done by Halogen Free Flame Retardent HRFR compound insulated (Unsheathed) 1.5 Sq.mm. copper flexible cable through interior conduit and Electrical Raceway.
Erection the above sign board with three nos. 40x40x6mm MS angle iron bracket the support on the back side rigidly grouted on suitable muffing which are making on the roof to avoid the uprooting by wind pressure and painting as per direction of EIC
Scaffolding arrangement for working outer wall of building by bamboo, ropes and wooden planks etc. and shifting of scaffolding materials after completion of work.
SUB HEAD : COMPOUND ILLUMINATION
Fixing only outdoor / street light typeLED light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting.
SITC of road lighting luminaire ( IP 65 ) with peanut lens and high power LED and to ensure uniform distribution, higher spacing between poles and maintenance free system and system lumen output will be minimum 110 lumen/w suitable for use with 230Volt 50Hz AC supply etc as required.
(i) Philips Model No. BRP 340 LED 138 CW HO SLC S1 PSU GR / or equavalent product of Crompton/Wipro having similar specification in all respect)
Supply and Fixing SMC Junction Boxes of dimention (250x200x105)mm with IP 67 protection (Sintex / Hensel )make for compound light. With 4 pole terminal stud and 6A 10KA C curve SP MCB Legrand make. On wall
Supply & Delivery of 1.1 KV grade XLPE/PVC insulated. PVC sheathed, steel Armoured Al. conductor Cable of the following size, and conforming to IS: 7098(Part-I):1988/1554(Part-I):1988/ 5831:1984/ 3961(Part-I):1967/ 3975:1970/ 10810:1984 / 3975:1970 /8130:1984/ 3961:1967/ 10418:1982 / 10810:1984 as amended upto date, in respect of component materials and tests, and as per the approved makes list attached herewith.
2 Core 4 Sq.mm
Laying on Wall / surface with Saddles / clamps. Laying of following cable on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
(i) Upto 2 core 25 sqmm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
2 Core 4 Sq.mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
2 Core 4 Sq.mm
Connection from loop box to fittings by S&L of following 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire through 13 mm dia polythene pipe (As per approved make list). 3 x 1.5 sqmm
S & F 415V 63A Timer controller for out side light or compound light in SS double door 4-way TPNDB enclosure with S&F following electrical accessories & front door locking arrangement with all connection incl. earthing attachment on wall as per direction of EIC :- i) 63A TPNMCB --- 1 No ii) 24 Hr programmable Digital/Analog Timer ---- 1 No iii) 4 pole power contractor with 1 NO +1 NC additional contact block ---- 1 set iv) 20A Auto-Off-Bipass SPDT toggle switch ---- 1 No. vi) Two nos. On & Off push bottom switch.
Supplying and fixing 415V, 160 A TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc
Terms and condition
The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules
Defect Liability period 1 (One) Year
(Rates should be Quoted inclusive of all taxes & duities and L.W.C. @ 1% as applicable)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .