Name of Work : CONSTRUCTION OF BOYS HOSTEL BUILDING WITH CANTEEN BUILDING
FOR TRIBAL DEVELOPMENT AT JAMNAGAR.
BILL OF QUANTITIES
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
1 Excavation for foundation in Dense or Hard soil incl. 595.00 Cum. 161.07
sorting out and stacking of useful materials and
disposing of the excavated stuff with all lead and lift.
2 Excavation for foundation in Hard Murrum incl. 606.00 Cum. 273.44
sorting out and stacking of useful materials and
disposing of the excavated stuff with all lead and lift.
3 Excavation for foundation in Soft Rock not requiring 473.90 Cum. 304.35
blasting incl. sorting out and stacking of useful
materials and disposing of the excavated stuff up to
all lead and lift.
4 Providing and laying cement concrete 1:2:4 (1- 110.00 Cum. 3791.11
Cement : 2- Coarse sand : 4- graded stone
aggregates 20 mm nominal size) and curing
complete excluding cost of formwork in Foundation
5 Pro. & laying controlled cement concrete M-250 and 406.00 Cum. 4836.89
curing complete inclu. the cost of form work and
foundation, footings, base of column and mass
6 Providing and laying Controlled cement concrete M 108.00 Cum. 8022.86
250 and curing complete including the cost of
formwork and excluding cost of reinforcement for
reinforced concrete work in Column FOR all Floor.
7 Providing and laying Controlled cement concrete M 149.00 Cum. 6075.15
250 and curing complete including the cost of
formwork and excluding cost of reinforcement for
reinforced concrete work in Plinth Beam .
8 Providing and laying Controlled cement concrete M 161.00 Cum. 6440.27
250 and curing complete including the cost of
formwork and excluding cost of reinforcement for
reinforced concrete work in Beam for all floor.
9 Providing and laying Controlled cement concrete M 240.00 Cum. 6766.69
250 and curing complete including the cost of
formwork and excluding cost of reinforcement for
reinforced concrete work in Slab for any thickness
10 Providing and laying controlled cement concrete 157.50 Cum. 4674.06
M.250 and curing complete excluding the cost of
formwork and reinforcement for reinforced concrete
work in GRADE Slab
11 Providing and laying Controlled cement concrete M 30.00 Cum. 7308.36
250 and curing complete including the cost of
formwork and excluding cost of reinforcement for
reinforced concrete work in Stair Case for all floor.
12 Providing and laying Controlled cement concrete M 40.00 Cum. 6519.98
250 and curing complete including the cost of
formwork and excluding cost of reinforcement for
reinforced concrete work in Lintel for all Floor.
1 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
13 Providing and laying Controlled cement concrete M 3.00 Cum. 7277.05
250 and curing complete including the cost of
formwork and excluding cost of reinforcement for
reinforced concrete work for chhajja for all floors.
14 Providing and laying Controlled cement concrete M 3.00 Cum. 13174.44
250 and curing complete including the cost of
formwork and excluding cost of reinforcement for
reinforced concrete work for V & H Fins for all
15 Providing and laying Controlled cement concrete M 16.00 Cum. 6276.14
250 and curing complete including the cost of
formwork and excluding cost of reinforcement for
reinforced concrete work in wall caps/ coping.
16 Providing and laying cement concrete 1:4:8 (1- 331.00 Cum. 2910.82
cement : 4-Sand : 8-Crust stone aggregate 40mm
nominal size) & curing complete excluding cost of
formwork in foundation and plinth.
17 Providing Thermo Mechanical treated bar FE-500D 160700.00 Kg. 77.52
Steel Reinforcement for R.C.C. work including
bending, binding and placing in Position complete
18 Filling available excavated earth (excluding 612.00 Cum. 137.47
rock) in trenches. plinth, sides of foundations
etc. in layers not exceeding 20cm. in depth
consolidating each disposited layer by ramming
19 Filling in foundation and plinth with murrum or 2120.00 Cum. 304.59
selected soil in layers of 20cm. thickness including
watering, ramming and consolidating etc.
20 Filling in plinth with sand under floors including 194.00 Cum. 489.28
watering ramming, consolidating and dressing
21 Carrying out plinth treatment to post construction / 1336.00 Sqm. 124.35
existing structure by spraying chemical solution for
termite control treatment including labour and
material consistment with I.S.I specification. Using
Chlordene and Chiorpurfiles 20 EC. As Per
6131_paret-II Concentration Weight one percent is
recommended i.e one litre 20 EC chemical emulsion
with 19 liter give 1 % concentration inclusive of one
litre chemical emulsion application at the rate of
Litre chemical / Sqm of surface is recommended as
22 Brickwork using common burnt Clay building bricks 192.00 Cum. 4310.73
having crushing strength not less than
kg./Sq.Cm. in foundation and plinth in Cement
Mortar 1:5. (1- Cement : 5 -fine sand).
23 Brickwork using common burnt Clay building bricks 497.00 Cum. 4618.05
having crushing strength not less than
kg./Sq.Cm. in super structure in Cement Mortar 1:5.
(1- Cement : 5 -fine sand) for all floor.
24 Half brick masonry in common brunt clay 417.00 Sqm. 704.80
building bricks having crushing strength not less
than 35 Kg/Sq.Cm. in Cement mortar 1:4 ( 1-
Cement : 4 -coarse sand ) in Super structure for all
2 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
25 Providing and laying 25mm polished kota stone slab 1267.00 Sqm. 1019.39
flooring over 20mm (Average) thick base of cement
mortar 1`:6 (1-cement:6-coarse sand) or L.M. 1:1.5
laid over and jointed with grey cement slurry
including rubbing and polishing etc comp.
26 Providing and laying polished kota stone slab 25mm 84.00 Sqm. 1171.39
thick in risers of steps,skirting Dedo and pillars laid
on 10mm thick cement mortar 1:3 (1-Cement :
coarse sand) and jointed with gray cement slury
mixed with pigment to match the shade of slab
including rubbing and polishing etc. complete.
27 Providing and laying Ceamic GVT tiles 600 x 600mm 37.00 Sqm. 1592.77
10mm thick mett finished in flooring laid on a bed of
20 mm thick cement mortar 1:3 (1-cement : 3-coarse
sand ) finishing with flush pointing etc complete.
28 Providing and laying 300 x 600mm ceramic wall tiles 284.00 Sqm. 1618.02
with digital prints with matt/glassy finished with
3mm Horizontal grooves filed with coloured epoxy
grouting 8mm thick in skirting and dedo on a bed of
10mm thick cement mortar 1:3 (1-cement : 3-coarse
sand ) colours, shade and design to be approved by
29 Providing and laying 300 x 300mm Anti Skid Ceramic 85.00 Sqm. 1558.43
10mm thick mett finished in flooring laid on a bed of
20 mm thick cement mortar 1:3 (1-cement : 3-coarse
sand ) finishing with 3mm thick groove epoxy
coating etc complete.
30 Providing and laying 300 x 450mm GVT Vitrified wall 452.00 Sqm. 1583.68
tiles with digital prints with matt/glassy finished with
3mm Horizontal grooves filed with coloured epoxy
grouting 8mm thick in skirting and dedo on a bed of
10mm thick cement mortar 1:3 (1-cement : 3-coarse
sand ) colours, shade and design to be approved by
31 Providing and laying white glazed tiles 6mm thick in 6.00 Sqm. 964.47
flooring treads of steps and landing laid on a bed of
12mm thick cement mortar 1:3 (1-cement: 3-coarse
sand) finished with flush pointing in white cement.
32 Providing and laying white glazed tiles 6mm thick in 30.00 Sqm. 1091.96
skirting, risers of steps and dedo on a bed of 10mm
thick cement plaster 1:3 (1-cement: 3-coarse sand)
and jointed with white cement slurry)
33 Providing and fixing 18mm thick black granite stone 430.00 Sqm. 3174.43
in Jambs & sills for window over 10mm (Average)
thick base of cement mortar 1:3 (1-cement : 3-
coarse sand) laid over and jointed with grey cement
slurry including rubbing and polishing etc.
34 Providing & laying both side POLISHED KOTAH 96.00 Sqm. 851.43
STONE SHELVES to C.B. with making the grooves in
the walls and fixing the kotah stone finishing the
same with cement mortar 1:2 etc. complete.
3 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
35 Providing and fixing sandwich type platform of 75cm 9.00 Sqm. 8769.83
wide and 75cm high from finished floor level using
25mm thick kotah stone slab as a base and 18mm
thick mirror polished full round edged granite slab
on top , 25mm thick mirror polished /kotah stone
supports of 75cm wide at 45cm C/C or as directed
including providing /Granite side 'Patta' of 30cm
wide on three sides of the platform and S.S. Kitchen
Sink of size 610x460x200mm of Nirali or equilant
brand as per detailed drawing and as directed.
36 Providing and fixing sandwich type platform of 75cm 18.00 Sqm. 8500.16
wide and 75cm high from finished floor level using
25mm thick kotah stone slab as a base and 18mm
thick mirror polished full round edged granite slab
on top, 25mm thick mirror polished /kotah stone
supports of 75cm wide at 45cm C/C or as directed
including providing / Granite side 'Patta' of 30cm
wide on three sides of the platform as per detailed
drawing and as directed.
37 Providing and laying 50mm thick cement concrete 1069.00 Sqm. 347.14
flooring 1:2:4 (1-cement : 2-coarse sand : 4-graded
stone aggregate 20mm nominal size) laid in one
layer and finished with a floating coat of neat
38 Providing and mixing water proofing materials in 390.00 Per Bag 49.25
cement mortar in proportion recommended by the of
manufacturer. Kgs
39 Providing and laying broken China Mosaic Flooring 1018.00 Sqm. 779.69
for Terrace using 12mm to 20mm broken pieces of
glazed tiles to be laid over cement mortar 1:3 to
plain or slope and to be tempered to bring mortar
crème out upto surface using white cement
including rounding off junctions and extending them
up to 15cm. along the wall, clearing with water and
oxalic acid etc. as directed.
40 Providing and fixing 35 mm thick Flush door shutters 47.00 Sqm. 4616.28
, solid core construction with frame of first class
hardwood with cross board and face veneer or
plywood face panels with both side 1 mm thick
laminated sheet including Indian Teak Wood Frame
12 x7 cm size including Screw, Khili, SS hinges,SS
handle , megnate, stopers etc including Colour(One
coat of primer and two coat of enamel paint) of
Frame and edges of flush door shutter for D3
41 Providing and fixing 35 mm thick Flush door Double 24.00 Sqm. 6844.77
shutters , solid core construction with frame of first
class hardwood with cross board and face veneer or
plywood face panels with both side 1 mm thick
laminated sheet including Indian Teak Wood Frame
12 x7 cm size including Screw, Khili, SS hinges,SS
handle , megnate, stopers etc including Colour(One
coat of primer and two coat of enamel paint) of
Frame and edges of flush door shutter for D2
4 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
42 Providing and fixing FRP of 28mm thick Fibre Glass 76.00 Sqm. 1560.32
shutter with 1.5 to 2.0 mm thick fire retardent grade
FRP skin in depressed panel design having extra
reinforcement on sides & edges & in Gel coat finish.
The core of the shutter is to be filled up with injected
retardent grade polyurethane foam done in situ
alongwith embedded wooden pieces for stiffening &
also taking hinges & fintures. The whole FRP frame
& shutter is to be water proof ,weather proof,
termite proof & resistance to mild acid/alkali. Rates
are to be inclusive of S.S hinges with necessary
screws & alluminium S.S fixtures & fastenings &
fastener sleeve.
43 Providing and fixing colour anodized aluminum 74.00 Sqm. 3804.67
sliding three track window having frame bottom
section size 124mm x 51mm Of Jindal Section
& side and top section size 124 x 41mm of Jindal
section 20837 including shutter frame size 71 x
30mm of Jindal section 20993 with sliding type three
shutters with 5mm thick transparent tinted float
glass and one shutter for mosquito net of wire gauge
including rubber beading PVC virgin, heavy type
handle, bearing, fixture and fastening etc. including
all labour and material etc. complete.
44 Providing and fixing colour anodized aluminum 33.00 Sqm. 4388.59
sliding Two track window of Jindal Series E (30mm)
or equivalent having frame bottom section size
82.8mm x 38mm x 2mm Of Jindal Section 20878 &
side and top section size 82.8 x 38mm x 2mm of
Jindal section 20877 including shutter frame size
x 30mm of Jindal section 21675 with sliding type two
shutters with 5mm thick transparent tinted float
glass with rubber gasket , air lock strip and finishing
joint with transperant silicon sealent , heavy type
handle, bearing, fixture and fastening etc. including
all labour and material etc. complete.
45 Providing & fixing coloured anodized aluminium 17.00 Sqm. 2548.23
sectional louvered ventilator with frame size
63x38.10mm & 1.80mm thick ground glass and
coloured anodized aluminium louvers fixtures and
hold fasting etc. complete.
46 Structural steel work ( Confirming to IS 4923-1997) 21312.00 Kg. 131.82
riveted, bolted or welded in builtup for all type
sections, in framed work, including cutting, hoisting,
fixing in position and applying a priming coat of
approved steel primer all complete as per the
structural designs and directions of Engineer in
charge.Column ( 122 x 61 x 3.6mm )
47 Providing and fixing Colour coated corrugated /semi 395.00 Sqm. 765.35
corrugated Galvalume sheet 0.50 mm thick roofing
fixed with GI "J" or "L" hooks bolts and nets 8mm
dia with bitumen washing filled with white lead
complete excluding cost of purlins, rafters and
48 Providing 15mm thick cement plaster in single coat 2668.00 Sqm. 174.17
on Rough (Similar)side of single or half brick walls
for interior plastering upto floor two level and
finished even and smooth in Cement mortar 1:4 (1-
cement :4-sand) for all floor.
5 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
49 Providing 20mm thick water proof cement plaster 339.00 Sqm. 327.24
for sunk in single coat on brick concrete wall for
interior plastering upto floor two level finished even
and smooth (ii) Cement Mortar 1:3 (1-Cement:3-
sand) and mixing water proofing materials of
approved brand and manufacture in cement mortar
in proportion recommended by the manufacturer for
50 Filling in foundation and plinth with brick Bats. 11.00 Cum. 625.47
Chhara in layers of 20cm. thickness including
watering, remming and consolidating etc.
51 Providing 10mm thick cement plaster in single coat 1660.00 Sqm. 173.11
on ceiling and sofits of stair cases for interior
plastering upto floor two level and finished even and
smooth in Cement mortar 1:3 (1-cement:3-sand) For
52 20mm thick sand faced cement plaster on walls upto 3313.00 Sqm. 323.21
height 10 metres above ground level consisting of
12mm thick backing coat of C.M. 1:3 (1-cement : 3-
sand) and 8mm thick finishing coat of C.M. 1:1 (1-
cement : 1-sand) etc. complete.
53 Applying Two Coats of Birla or Asian Acrylic Lappy 4328.00 Sqm. 40.59
(Putty) and two coats of primer of approved brand
and manufacture on New Wall Surface to give an
even shade including thoroughly brushing the
surface free from mortar dropping and other foreign
matter and sand papered smooth.
54 Wall painting (two coats) with plastic emulsion paint 4328.00 Sqm. 86.37
of approved brand and manufacture on undecorated
wall surface to give an even shade including
throughly brushing the surface free from mortar
droppings and other foreign matter and sand
papered smooth.
55 Finishing Wall with Weather Proof Exterior Emulsion 3313.00 Sqm. 122.13
Paint on Wall Surface (Two Coats) to give an
required shape even shade after thoroguhly
brushing the surface to remove all dirt, and remains
of loose powdered materials etc. complete
56 Providing and fixing stainless steel railing having 31.00 Rmt. 5807.50
hand rail 850mm height and of 50mm dia and
baluster 32mm dia at 90 cm C/C and 4 horizontal
pipe of 19mm dia at required spacing as per design
and SS having 304 grade and 18 guage pipe
including fastening, hold fast, clumps, coach bolts
57 Providing and fixing stainless steel railing at 850mm 32.00 Rmt. 2090.70
height and of 50mm dia SS pipe with support of
horizontal pipe as 15mm dia at required spacing as
per design and SS having 304 grade and 15 guage
pipe including fastening, hold fast, clumps, coach
bolts for fixing to wall including touching finishing to
wall etc complete.
6 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
58 Providing and fixing frame type CB shutter of 18mm 36.00 Sqm. 5226.75
thick water proof plywood with 1.00mm ISI quality
1.0mm lamination for outside of frame and
cupboard and 0.80mm thick lamination to inside of
cupboard including necessary , hydraulic type S.S.
hinges , fixtures , fastenings of standard quality S.S.
with locking arrangement etc complete as per detail
drawing and as directed by Engineer-in-charge.
59 Providing and fixing cupboard with aluminum pipe 14.00 Sqm. 9292.00
frame of size 50x25mm filled with non-teak wood
and 18mm thick water proof plywood shutter with
nos of SS basket two of size 18" x 20" x 4" , two of
size 18"x 20" x 6" and two of size 18" x 20" x 8" with
necessary intranal arragement front plywood
necessary telescopic channels for drawers and
remaining part of two shutter including 1.00mm
thick laminated sheet for outer face and 0.8mm
sheet for inner face and with 20x20cm teak wood
beading including necessary S.S. hinges and S.S.
fixtures etc complete.
60 Providing and fixing box type cupboard for 8.00 Sqm. 7549.75
wardrobe including frame work with 19mm thick
water proof plywood rear side with 8mm thick
water proof plywood and shutter with 19mm
plywood with necessary drawers of same materials
with 1.00mm thick lamination sheet for outside and
0.80mm thick laminated sheet for inside work.
including cost of all heavy type stainless steel
fittings, sliding channels , locking arrangements for
shutter and drawers including teak wood beading
etc complete as per design and drawings.
61 Providing and fixing 5mm thick glass mirror machine 9.00 Sqm. 2544.19
cut belveled edge mounted on wall with special type
wall touch SS mirror bracket fixing with necessary
62 Providing and fixing wash down water closet 21.00 No. 9408.15
(European type Wall hung) Jaquar Vignette wall
hung size of 615 x 400 x 363mm with Hydraulic seat
cover with inlet & outlet gasket, CI chair brackets
including concealed type Metropole flush valve
40mm concealed body 100mm square plate of
Jaquar or equivalent quality with Health flow set etc.
63 Providing and fixing special type wash basin on 14.00 No. 6742.76
counter top of size 610x460mm of CERA or
equivalent quality including pillar tap, Stop cock
64 Providing erecting and fixing Tripal layer ISI water 10000.00 Liter. 12.12
tank of required capacity each with all necessary
fittings , tank cover and as required connection etc.
complete on terrace
65 Providing and fixing 15mm dia Jaguar or equivalent 10.00 No. 801.94
regular body stop cock etc complete.
66 Providing and fixing Heavy type lang body bib tap of 94.00 No. 1103.93
Jaguar or Equivalent quality of 15mm dia etc
67 Providing and fixing heavy type Push type bib tap of 11.00 No. 1277.65
Jaguar or equivalent quality of 15mm dia etc.
7 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
68 Providing and fixing concealed center point to wall 250.00 Rmt. 447.72
ceiling & floor CPVC (SDR 13.5) PIPE having
National Sanitation Foundation (NSF) seal for
potable water of 40mm dia. nominal bore tube
fittings and clamps including making good the wall,
ceiling and floor etc. complete.
69 Providing and fixing Stainless steel Heavy Type 21.00 No. 1150.39
Brass Towel Rack 600mm considering & 12mm dia
rod and one 20mm dia rod including 3 to 4 pegs
including C.P. Brass Brackets etc complete
70 Providing and fixing Stainless steel Heavy Type 3.00 No. 348.45
Napkin Ring etc complete
71 Providing and fixing concealed center point to wall 54.00 Rmt. 170.35
ceiling & floor CPVC (SDR 13.5) PIPE having
National Sanitation Foundation (NSF) seal for
potable water of 15mm dia. nominal bore tube
fittings and clamps including making good the wall,
ceiling and floor etc. complete.
72 Providing laying and jointing in true line and level 114.00 Rmt. 72.64
15mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water
including fittings as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the help
of clamp at every two metre C/C or shall be
concealed as directed including necessary fittings
etc. including testing of pipe and joints and fixing the
same with adhesive solvent, including cost of all
73 Providing laying and jointing in true line and level 135.00 Rmt. 91.83
25mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water
including fittings as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the help
of clamp at every two metre C/C or shall be
concealed as directed including necessary fittings
etc. including testing of pipe and joints and fixing the
same with adhesive solvent, including cost of all
74 Providing laying and jointing in true line and level 186.00 Rmt. 148.11
40mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water
including fittings as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the help
of clamp at every two metre C/C or shall be
concealed as directed including necessary fittings
etc. including testing of pipe and joints and fixing the
same with adhesive solvent, including cost of all
75 Providing and fixing to wall, ceiling and floor 100.00 Rmt. 794.18
galvanized mild steel tubes (Medium grade) of the
50mm nominal bore, tube fittings and clamps
including making good the wall, ceiling and floor.
76 Providing and fixing PVC pipe of 6 Kg / F / Sq.M. 246.90 Rmt. 356.53
Water pressure polythene pipe of 90mm inside dia.
high density complete including fixing by clamps to
wall including making good the wall ceiling and floor
8 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
77 Providing, laying and jointing in true line and level 539.00 Rmt. 897.78
110mm dia U.P.V.C. SWR Type B-Pipe conforming
to IS 13592-1992 with one end plain and other end
socketed with rubbering & fitting conforming to IS :
14735-1999 of approved make for drainage system
pipe line, pipe shall be jointed with each other with
rubber lubricant, pipe shall be fixed on wall using of
PVC clamp of the size 160mm diameter x 210mm
length x 196mm high at every 2000mm center to
center or shall be concealed in walls as directed
including necessary fittings such as bends, shoes
etc. including testing of pies and joints and jointed
with adhesive solvent cement including cost of all
78 Providing, laying and jointing in true line and level 130.00 Rmt. 834.38
160mm dia U.P.V.C. SWR Type B-Pipe conforming
to IS 13592-1992 with one end plain and other end
socketed with rubbering & fitting conforming to IS :
14735-1999 of approved make for drainage system
pipe line, pipe shall be jointed with each other with
rubber lubricant, pipe shall be fixed on wall using of
PVC clamp of the size 160mm diameter x 210mm
length x 196mm high at every 2000mm center to
center or shall be concealed in walls as directed
including necessary fittings such as bends, shoes
etc. including testing of pies and joints and jointed
with adhesive solvent cement including cost of all
79 Providing and fixing 25mm dia Gun metal check or 18.00 No. 420.63
non-return fully way wheel valve.
80 Providing and fixing 40mm dia Gun metal check or 13.00 No. 663.42
non-return fully way wheel valve.
81 Providing and fixing 50mm dia Gun metal check or 2.00 No. 1878.60
non-return fully way wheel valve.
82 Supplying and fixing standard quality (Kranti or 1.00 No. 7105.35
equivalent) 50mm dia water meter with flange, nut
bolt etc. complete.
83 Providing and fixing PVC SWR Nahni Trap IS 14735 66.00 No. 588.26
for drain with jali of the 75mm nominal diameter of
self cleansing design with C.I. Scrwed down or
hinged grating including the cost of cutting and
making good the walls.
84 Providing and fixing S.W. gully trap with C.I. grating 8.00 No. 1292.19
brick masonry chamber and water tight C.I. cover
with frame of 300mm x 300mm size (inside) with
standard weight wtih Square mouth traps size of
100mm x 100mm size P type
85 Constructing brick masonry chamber for 45.00 No. 3417.70
underground C.I. Inspection chamber and bends
with briocks having croshing strength not less than
35Kg. Cm2 in C.M. 1:5 C.I. cover with frame (Light
duty) 455mm x 610mm intenal dimensions total
weight of cover with frame to be not less than 38Kg.
(Wt. of cover 23 Kg.) and Wt. of frame 15Kg. )
(R.C.C. top slabe with 1:2:4 mix (1-cement :2- coarse
sand :4-graded stone aggregate 20mm size)
foundation concrete 1:5:10 inside plaster 15mm
thick with cement mortar 1:3 finished smooth with a
floating coat of neat cement on walls and bed
concrete etc. complete with Inside dimensions
455mmx 610mm and required depth for single pipe
9 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
86 Supplying and fixing reinforced concrete heavy duty 219.00 Rmt. 659.99
nonpressure pipes with collars for culverts carrying
heavy traffic as per IS 458-1991 specifications
including setting the pipes in C.M. 1:2 watering and
laying (to level or slopes) of class NP3 of Internal
87 Constructing brick masonry chamber for 18.00 Sqm. 2596.71
underground Inspection chamber and bends with
bricks having croshing strength not less than 35Kg.
Cm2 in C.M. 1:5 foundation concrete 1:5:10 inside
plaster 15mm thick with cement mortar 1:3 finished
smooth with a floating coat of neat cement on walls
and bed concrete etc. complete.(i) Inside
dimensions 455mmx 610mm and 650mm deep for
single pipe line.
88 Providing and fixing pre-cast Rubber Dye / steel Dye 424.00 Sqm. 707.54
inter locking concrete block 60mm thick with grade
of concrete M300 pnumatic compressed / vibrated
mechanically and as per approved design
Confirming to IS 15658 : 2006 including 35 mm Sand
layer for levelling and filling the joint with sand in
proper line and level as per guidlines of IRC : SP 63-
2018 etc. Complete.
89 Providing and fixing Pre-Cast Concrete Kerb Stone 80.00 Rmt. 410.41
of gray cement based concrete block 30cm. length,
30cm. height and 15cm. thick of M-250 Grade
concrete as per approved design and including
excavation for fixing in proper line and level, filling
the joint with C.M. 1:3 (1-Cement : 3-Fine Sand) etc.
90 Providing and constructing and junction chamber of 20.00 No. 2588.63
size 0.45x0.45x0.45 mt. including necessary
excavating 23 Cum. brickwall, beding CC 1:2:4, top
RCC slab, 15mm thick plaster and connection of rain
water pipes as per detail drawings and as directed
by engineer – in – charge.
91 Providing filter chamber of brick work in C.M. 1:5 of 1.00 No. 13948.10
size 2.06mt X 1.21 mt x 1.20mt and excavation
dimension of 2.66x1.81x1.35mt including C.C. 1:2:4
bed concrete of 0.15mt thick including brick work in
C.M. 1:5 for 23cm thick wall including 15mm thick
cement plaster inside and out side and 10 cm thick
RCC 1:2:4 top over with CRS steel and manhole
cover with frame of minimum weight of 35 Kg and
filling filter material Kapchi and sand as per detailed
92 Providing recharging pit of size 1.20mt dia and 1.00 No. 42356.37
1.20mt Depth of water logging with excavation filling
the pir with brick bats & sand in layerincluding
macking 300mm dia bore dpeth of 4.5mt & filling
bricks bats as per drawing as directed.
93 Providing and fixing Sign board on Alluminium 9.00 Sqm. 3467.33
Composite Pannel 4 mm thick and letter with sticker
sheet including fixing etc complete.
10 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
94 Providing and fixing special type clamping system 30.00 No. 213.11
made out from C patti, Z patti, L Clamp , U clamp
with Nut/ Bolt and washer as suitable arrangement
for water supply and plumbing system like Drainage
Line , Rain Water line and supply line for Hot and
Cold water etc line fitting from GF to 2nd Floor
required as per site condition for fixing etc
complete. (A) 15 to 40mm dia Pipe
95 Providing and fixing special type clamping system 30.00 No. 242.40
made out from C patti, Z patti, L Clamp , U clamp
with Nut/ Bolt and washer as suitable arrangement
for water supply and plumbing system like Drainage
Line , Rain Water line and supply line for Hot and
Cold water etc line fitting from GF to 2nd Floor
required as per site condition for fixing etc
complete. (B) 50 to 65mm dia pipe
96 Providing and fixing special type clamping system 50.00 No. 275.73
made out from C patti, Z patti, L Clamp , U clamp
with Nut/ Bolt and washer as suitable arrangement
for water supply and plumbing system like Drainage
Line , Rain Water line and supply line for Hot and
Cold water etc line fitting from GF to 2nd Floor
required as per site condition for fixing etc
complete. (C) 75 to 110mm dia pipe
97 Drilling of 215mm dia bore hole in over burden 200.00 Rmt. 551.46
strata (alternative layer of lime stone and yellow
stridly formation) by DTH regi. up to required depth
including fixing of 175/180 dia ERW/PVC pipe if
required drilling by 165mm dia bore hole in hard
rock strata DTH drilling method up to all depth.
98 Earthwork for embankment including breaking 1098.00 Cum. 182.14
clods, dressing with all lead and lift and including
watering rolling and consolidation of subgrade in
layers at O.M.C. to required dry density including
filling the depression which occur during the
process using power roller 8T to 10T.(E) From
Borrow area within all lead.
99 Providing and laying compacted W.B.M. 150mm 128.00 Cum. 1246.34
thick of grade-II in two layers each of 75mm thick of
machine crushed BT metal of size 40mm to 63mm
with using 13% stone screenings of 13.2mm size and
7% stone dust as filler including spreading watering
and consolidation by vibratory roller etc. comp. in
100 Providing and casting in situ controlled trimix 171.00 Cum. 7070.00
cement concrete M-250 for average 200mm thick
road work laid as directed including adding super
platisizer admixture of IS make and providing and
laying M.S. side rail of road thickness with
necessary nut bolts plates fixing as per width
applying plate vibrator (electric or diesel) on
channel compressor with vacuum dewatering
system by using all necessary equipments and
materials and machinery such as running screed
vibrator on prelaid M.S. channel for leveling
,Vacume pump, floating and power towelling etc
with filling the joints with bitumen as directed etc
11 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
101 Painting lines, deashes, arrows, letters etc on 44.00 Sqm. 59.17
roads, Air fields and like in two coats with road
marking paint, brushing including cleaning the
surface of all dirt, dust and other foreign matter for
102 Distance Informatory/ Destubatuib sign :Providing 2.00 No. 18254.19
and fixing sing boards made out of 2mm aluminium
sheet; size 180 x 120cms. rectangle as as per the
design of IRC-67-1977 pre treated with phospheting
process & acid etching; coated with one coat of
epoxy primer and two coats of best quality epoxy
paint; reflectorised with retro refiective sheeting as
per latest M.O.S.T. Specifications; Letters and
numerals should be as per IRC-30-1968, 3.1m long
(2 nos) stand post and frame fabricated from
suitable size iron angle of 50 x 50 x 5mm 75 x 75 x
6mm as required; painted with best quality epoxy
coatings in black and white bends. the details of
symbol or inscription / numerals for each board shall
be as per the instruction of engineer in charge. The
fixing at site shall be in 1:2:4 CC block of size 45 x
x 60cms. for each leg. including excavation curing
etc. complete under the supervision of engineer in
charge.(B)High Intensity Grade.
103 Providing and fixing cattle trap of required size and 12.00 Sqm. 9072.83
design by providing GI pipes 50mm dia at 10 cm c/c
including providing “c" chanels 100x50x6x6mm size
including necessary excavation 10 CM thick CC
1:2:4 for foundation complete CC wall of CC 1:3:6
with cement plaster 15mm thick in CM 1:4 etc.
complete as directed by Engineer – in – Charge.
104 Providing and fixing RBT fencing with punched tape 293.00 Rmt. 365.62
concertina upto 3 m height of wall with angle iron ‘Y’
shaped 40 x 40 x 5mm placed 2.4 m or 3.00 m apart
and with 6 horizontal R.B.T. reinforced barbed
wire,stud tied with G.I. staples and G.I. clips to
retain horizontal, including necessary bolts or G.I.
barbed wire tied to angle iron, all complete as per
direction of Engineer-in-charge, with reinforced
barbed tape(R.B.T.) / Spring core (2.5mm thick)
wire of high tensile strength of 165 kg/ sq.mm with
tape (0.52 mm thick) and weight 43.478 gm/ metre.
(Cement concrete for fixing angle will be paid under
105 Preparing the existing land /soil and removal of 2221.00 Sqm. 24.74
unserviceable soil, stone ,unwanted vegetation and
disposing of the same as directed.
106 Preparing the land by filling fertile/ selected garden 2221.00 Sqm. 77.77
soil, including leveling & fine dressing and mixing
manure/bio tech fertilizer/ fertilizer and termite
treatment as per requirement.
107 Plantation of carpet type lawn including labour 2221.00 Sqm. 57.57
materials , watering and growing etc. as per
instruction of EIC.
108 Plantation of flower bed with selected flower plant 223.00 Sqm. 232.30
including planting the same at 45 CM apart and
growing the same including as per instruction of
109 Planting of hedge with selected hedge plant like 387.00 Rmt. 154.53
Golden , Duranta, Red Bhaji or selected plant @
CM apart as per instruction of EIC.
12 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
110 Planting of selected shrubb trees like Ticoma, 200.00 No. 64.64
Nerium or other selected plant including preparing
pit of size 30 x 30 x 30 CM and filing with selected
garden soil including manure, fertilizer and as per
instruction of EIC.
111 Providing Three plants having minimum 2.00 mt. 50.00 No. 64.64
hight and healthy growth of various kinds as like
peltroform, Gulmahore, Karanj, Ambla, Rain tree,
Sapparni, Cherry, Cryjeliya, Spethodiya, Paras
Pipala, Garmali, Neem, Borsalli, Kadam, Buch,
Chanpo, Asopalav and as suggested etc.
112 Providing tree plants having minimum 2.00 mt height 20.00 No. 1742.25
and health growth of bottle palm tree, Cycus palm
and other palm tree planting including 30 x 30 x
Cm. pit filling with selected garden soil including
manure, fertilizer as per instruction of EIC.
113 Providing and fixing Precast Garden three seater 20.00 No. 3484.50
bench size of 4.50 Feet with back rest as per
Design drawing including fixing on site as EIC
114 Constructing hexagonal Gazebo by using necessary 3.00 No. 225836.00
excavation for foundation of MS. Structure framing
brick work , plaster work & weather proof paint and
1mm thick Galvalume Sheet roofing as per required
shape, Kotah Stone flooring , kotah stone slab type
55cm wide seating arrangement with necessary
support of 25mm thick kotah stone vertical support
and in centre 120cm dia kotah stone table with four
nos vertical support with finished edge and in
periphery 0.60mt height wall with required pattern
with including plaster and exterior paint etc
complete for all required material , labour etc work
carried out as per drawing & instruction by EIC.
115 Supply & Installing of ABC Type - 6 Kg, Capacity 20.00 No. 2846.18
Fire Extinguisher as per IS -2171 ISI - mark , with
necessary Fittings etc. complete.
116 Supply & Installing of Gas Co2 Type–4.5 Kg.. 20.00 No. 6736.70
Capacity Fire Extinguisher as per IS And ISI - mark
, with necessary Fittings etc. complete.
Total of Civil Items (A) Rs.
(B) Electrical Work
117 Point wiring for Light / Bell with 2-1.5 sq.mm & earth 313.00 Pt. 410.06
wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV
grade FRLS PVC insulated multi strand copper wires up to
10 mtr length , in below type of pipe erected with 6A
Modular type switch / bell push & accessories and earth
continuity of following type, erected on PVC /
Metallic/Wooden box, single mounting base frame
covered with textured/metallic/white front plate modules
erected on / in wall / ceiling as per pipe erected, with
necessary Lamp holder/ceiling rose / H.D.Connector as
directed.(j) in existing pipe erected concealed in
wall/ceiling complete Cat III
13 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
118 Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 79.00 Pt. 556.51
sq.mm (Green) both are of .ISI marked 1.1 KV Grade
FRLS PVC insulated multi strand copper wires up to
mtr length, in below type of pipe erected with 6A Modular
type switch and hum free EME step type electronic fan
regulator mounted and accessories with earth continuity
of following type erected on PVC / Metallic/Wooden box,
single mounting base frame covered with
textured/metallic/white front plate modules erected on /
in wall / ceiling as per pipe erected. with necessary
ceiling rose / H.D.Connector as directed. (j) in existing
pipe erected concealed in wall/ceiling complete cat-III
119 Point wiring for Individual Plug with & earth wire of 1.5 3.00 Pt. 425.21
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS
PVC insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected complete with
Modular type switch & 5 pin Plug erected on PVC /
Metallic/Wooden box covered with appropriate front plate
modules erected on / in wall / ceiling as per pipe erected
with following type of accessories. [I] For 6A Plug and 6 a
switch with 2-1.5 sq.mm Cu. Wire from nearby
switchboard/mcb db board (j) in existing pipe erected
concealed in wall/ceiling complete cat-III
120 [III] For 16A Plug and 16 amp switch with 2-4 sq.mm Cu. 43.00 Pt. 702.96
Wire with 2.5 sq.mm ( green) earthing wire from mcb d b
board. (j) in existing pipe erected concealed in
wall/ceiling complete Cat. III
121 Point wiring for on board Looped Plug with 6A Modular 98.00 Pt. 257.55
type switch & 5 pin socket erected on PVC /
Metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate modules
erected on / in wall / ceiling with following type
accessories cat-III
122 Point wiring for Two Way Controlled Light Point with 2-1.5 4.00 Pt. 514.09
sq.mm & earth wire of 1.5 sq.mm (green) both are of .ISI
marked 1.1 KV grade FRLS PVC insulated multi strand
copper wires erected in below type of pipe with 6A
Modular type switches and following type of accessories
erected on PVC / Metallic/Wooden box, single mounting
base frame covered with textured / metallic/white front
plate modules erected on / in wall / ceiling as per pipe
erected. with necessary batten/angle holder or ceiling
rose or H.D.Connector as directed. (j) in existing pipe
erected concealed in wall/ceiling complete cat-III
123 Providing following type of Modular Type Accessories 80.00 Ea. 25.25
mounted with PVC / metallic/Wooden box, single mounting
base frame covered with textured / metallic/white front
plate , modules erected with necessary connections as
per site situation directed by Engineer In charge (7) Blank
Plate Single cat-III
124 Providing and erecting ISI mark Medium class RIGID PVC 3204.00 Mtr. 24.24
PIPES of following size complete to be erected on/in wall
or ceiling erected with necessary PVC fittings & Junction
boxes fixed with adhesive solution & Clamps with
following dia of pipes, in approved manner as directed (a)
126 Providing and erecting Mains with 1.1 KV grade FRLS 55.00 Mtr. 46.46
PVC insulated ISI marked stranded Copper conductor
wire in following type of pipe to be erected concealed in
/flushed on wall/ceiling, with 1.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green
colour for earth continuity of following size (E) in existing
pipe (a) 2 wire 1.5 sq. mm
14 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
127 (E) in existing pipe (b) 2 wire 2.5 sq. mm 1888.00 Mtr. 62.62
128 providing and erecting Mains with 1.1 KV grade FRLS PVC 200.00 Mtr. 86.86
insulated ISI marked stranded Copper conductor wire in
following type of pipe to be erected in / on wall / ceiling
with 2.5 sq. mm copper conductor FRLS PVC insulated
stranded wire of green colour for earth continuity of
following size (E) in existing pipe (a) 2 wire 4 sq. mm
129 (E) in existing pipe (b) 2 wire 6 sq. mm 15.00 Mtr. 121.20
130 (E) in existing pipe (h) 4 wire 6 sq. mm 296.00 Mtr. 240.38
131 providing and erecting Mains with ISI marked, 1.5KV 16.00 Mtr. 12.12
grade electrolyte multi stranded, annealed copper
conductor with heat resistant PVC insulated conforms to
IS 694, IEC - 227 erected in existing pipe of following size
(Specifically for control panel, relays, power switchgears,
motor starters & control wiring) with required size of
copper lugs, nuts and bolts if required. (a) One wire
132 (e) One wire 6.00 sq. mm 108.00 Mtr. 56.56
133 (h) One wire 25.00 sq. mm 14.00 Mtr. 236.34
134 (i) One wire 35.00 sq. mm 8.00 Mtr. 300.98
135 Supplying and erecting Flexible PVC insulated multi 183.00 Mtr. 46.46
strand multi core 1.1 kv grade ISI marked copper wires of
following size to be erected as directed.(e) 1.50 Sq.mm
core round PVC sheathed
136 Providing & erecting Switch board for Computer or 89.00 Ea 1133.22
electric apparatus consisting of following modular type
accessories mounted with PVC / Metallic
concealed/open box with single mounting base frame
covered with textured/metallic /white front plate, modules
erected with necessary connections as directed 1 no.
6A/16A universal plug-switch combined. 3 nos. 6A Switch
3 nos. 6A 5 pin Plug
For Modular Type Accessories cat-III
137 Supplying and erecting LED indoor fittings with LEDs of 226.00 Ea 373.70
wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,
with housing used as a heat sink shall be made of thick
sheet Steel conforming to IS: 513/CRCA/ aluminium die
cast powder coated and high U.V. & corrosion resistance
with diffuser with company mark/name 160V to 270V,
Power Factor more than 0.9, THD < 15%,CCT 3000 K to
6500K,Luminaire efficacy> 85 lumens/watt ,LED driver
efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates) (NOTE:
Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may select
any wattage capacity between the ranges shown.) (A)
Tube Light with integral driver (iv) 22 Watts, Surge -
2KV,IP-20, conventional 4 feet cat-III
138 Supplying and erecting LED street light / Flood light 24.00 Ea 5976.17
fittings with High power White LEDs wattage of 3 Watt and
above assembled on single MCPCB, efficiency more than
130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with
company mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K
to 5700K,Uniformity ratio >0.45, Luminaire efficacy>
lumens/watt . LED driver efficiency > 85 %.( fittings
required LM-79 & LM-80 certificates)(NOTE: Below
description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) (A) Street
Light (IP-65), Surge protection -4KV integral and ,Light
must have 440VAC line supply with over-voltage
protection. (iii) 90 watts cat-III
15 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
139 (B) Flood Light (IP-65), Surge protection -4KV integral 3.00 Ea 7266.95
and ,Light must have 440VAC line supply with over-
voltage protection. (iv) 100 to 120 watts cat-III
140 (B) Flood Light (IP-65), Surge protection -4KV integral 10.00 Ea 9647.52
and ,Light must have 440VAC line supply with over-
voltage protection. (vi) 200 watts cat-III
141 (C) Post Top Lantern LED fitting comprises of finish cast 2.00 Ea 4819.72
aluminum spigot and spun aluminum canopy fixed with
opal polycarbonate, pipe arrangement for vertical
mounting driver and accessories wired upto terminal
block.IP 65 (ii)40W Cat iii
142 Pproviding and erecting Approved make Four pole 4.00 Ea 6173.12
moulded case circuit breaker having breaking capacity
ICU of 25 KA. at 415 V,having normal current rating up to
63 A to 100A. with Fixed thermal & magnetic release
suitable to work on A.C. supply 50 c/s. with all internal
connections, spreader tinned copper & complete erected
in existing 16 G.M.S. housing. ICS=100% of ICU only Cat
143 Pproviding and erecting Approved make Four pole 4.00 Ea 6790.43
moulded case circuit breaker having breaking capacity
ICU of 25 KA. at 415 V,having normal current rating up to
63 A to 100A. with Fixed thermal & magnetic release
suitable to work on A.C. supply 50 c/s. with all internal
connections, spreader tinned copper & complete erected
in existing 16 G.M.S. housing. ICS=100% of ICU only Cat
III Note:-1 Add Rs. 10% extra for housing/Encloser of
MCCB for Item No 3-4-1 to 3-4-12 (The Enclosures should
be used of same company of MCCBs to be used)
144 Providing and erecting Approved make Earth fault Relay 2.00 Ea 4687.41
suitable to mount with inter connection suitable to
following size of moulded case circuit breaker having CT
ratio & MCCB rating as following along with shunt trip
220V AC. with all internal connections & complete
erected in existing M.S.housing.. (1) 63 A -100 A , CT
145 Supplying & erecting approved make Four Pole 415V 1.00 Ea 4785.38
change over switch interior for panel mounting with
operating mechanism A.C.23 duty confirming to IS for
(B)63 A Cat-III
147 Supplying and erecting triple pole & neutral 440V / 500V 1.00 Rn. Mtr 1961.42
panel mounting Copper Busbars with four equal Nos. of
electrolyte bus having current density not more than
Amp. / sq.mm (Rated current / cross section area) duly
wrapped with colour insulating tape for phase sequence
of following current carrying capacity, erected with
necessary bus bar supports /insulators, main cable
socket to each bar, erected in existing cubical panel with
necessary connections. (A) Suitable for 100 Amp.
148 providing and erecting Miniature circuit breaker single 39.00 Ea 270.68
pole 2A system and having breaking capacity 10 KA to be
erected in existing box. confirming to IS 8828/1996 with
ISI Mark Cat iii
149 providing and erecting Miniature circuit breaker single 142.00 Ea 112.11
pole 10 A to 25A suitable to operate on 240 V A.C. system
and having breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996 with ISI Mark cat-
150 Providing & erecting 240 V MCB double pole switch for 2.00 Ea 278.76
lighting Load (B Curve) having 10 KA breaking capacity &
confirms to IS : 8828 in existing box having following
capacity (A) 32 Amp. cat-III
151 (B) 40 Amp. cat-III 9.00 Ea 295.93
16 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
152 Providing & erecting 415V MCB Four Pole Switch for 25.00 Ea 638.32
Lighting Load (B curve) having 10KA breaking capacity &
confirms to IS :8828 in existing box having following
capacity (b) 40 Amp. Cat iii
153 Providing & erecting 415 V MCB Four Pole for Motor & 4.00 Ea 595.90
Inductive Load (C Curve) having 10KA breaking capacity
& confirms to IS :8828 in existing box having following
capacity (a) 32 Amp. cat-III
154 Sheets steel powder coated enclosure suitable for 26.00 Ea 176.75
incorporating One/Two nos. MCB
155 Providing and erecting Sheet Steel powder coated MCB 4.00 Ea 629.23
distribution board - flush / surface mounted fitted with
busbar, neutral link, earth bar and DIN rail, Conforms to
IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs should be used of
same company of MCB to be used) suitable for (A) single
phase incoming and horizontal single phase outgoing (b)
sheet steel double door (IP-43)(i)4 way
156 (A) single phase incoming and horizontal single phase 1.00 Ea 1680.64
outgoing (b) sheet steel double door (IP-43)(v) 16 way
157 (B) three phase incoming and single phase horizontal type 5.00 Ea 2339.16
outgoing Per phase isolation type (PPI) (b) sheet steel
double door (i)4 way
158 (B) three phase incoming and single phase horizontal type 4.00 Ea 2913.85
outgoing Per phase isolation type (PPI) (b) sheet steel
double door (ii)6 way
159 providing and erecting Approved make RCCBs 24.00 Ea 1969.50
conforming to IS: 12640 and having sensitivity of 30 mA
and Short Circuit withstand capacity of 10 KA and
suitable for operation on single phase 240 V,50Hz. having
characteristic of quick action & tripping with all advance
feature & do not incorporate any electronic component.
for following Max. rating erected as directed (i)
Amps.DP Cat III
160 (ii) 40Amps. DP Cat-III 28.00 Ea 2235.13
161 Providing and erecting metallic vitrified danger notice 2.00 Ea 69.69
board as per language suggested by engineer incharge
for MEDIUM VOLTAGE installation to be erected as per IS-
162 Providing and erecting required size Copper strip for 8.00 Kg 794.87
earthing of H.T. OCB / ACB/ Transformer, LT panel board,
Motors etc. using copper clamp.
163 Providing and erecting Annealed bare Copper wire 8 to 12 6.00 Kg 794.87
17 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
164 Supplying & erecting earth pit of minimum bore 7.00 Ea 4591.46
dia.150mm size approved make Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-1987
made of corrosion free hot dipped G.I.Pipes having Outer
pipe dia of 50mm having 80-200 Micron galvanising, Inner
pipe dia of 25 mm having 200-250 Micron galvanising,
connection terminal dia of 12mm with constant ohmic
value surrounded by highly conductive compound with
high charge dissipation suitable for following type of
applications with chamber and heavy duty cover.
(A)(approved make OEM has to submit test certificate
including value of earth resistance of installation duly
stamped and signed by agency and officer Incharge has
to ensure the value of earthing resistane mentioned in
test Certificate) & having back filling compound of (B)
Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm /
meter testing as per IEC 62561-2017, Voltage drop:- <
volt at no load & dry form, Sulphar content:- <2%(C) Back
fill Compound :- Earthing compound should be capable to
retain moisture for long time Necessary test report must
be submitted by Agency. (a) For Electrical Installation up
to 440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
165 Providing & erecting weather proof, dust & vermin proof, 2.50 Sq. Mtr 14902.55
floor mounted front operated indoor type cubical panel
board necessary IP-42 and above protection as per
approval from engineer incharge made from 14 SWG thick
CRC M.S. sheet for outer body & doors, 16 SWG thick
CRC M.S.sheet for internal partitions with necessary
accesories , supporting angles/ flats channel including
cutting, bending, drilling, welding, riveting with internal
partitions & cable alley as per requirements & instruction
of engineer-in-charge with erection of supplied switch
gears, BUSBARS, suitable size of inter connecting PVC
copper wire / copper-aluminium strips, rubber grommets,
rib, bakelite control fuses/MCB for measuring
instruments, earth bus & earth bolts, foundation flange -
bolts-base Plates, sufficient nos. of hinged doors, handles
with locking arrangement and rubber gasket, heavy duty
end terminal connection, danger notice board,necessary
ventilation,earthing strip complete. The Panel shall be
painted with epoxy powder coating. (The rates excludes
the cost of switchgears, bus bars, inter connecting mains
& Copper Aluminium strips, meters, Fuses etc. The
dimension shall be measured excluding base beams) The
panel shall be supplied with following approved
manufacturers with following size. (B) The standard
companies switch gear shall be used and only
manufacturers at CPRI approved factory (i) with 350mm
166 Providing , erecting , fabricating the M.S. structure as per 190.00 Kg 77.77
requirement on site incorporating proper size of M.S.
angles,square,round, flats, bars, channels, sections
complete with cutting, welding, grinding & finishing duly
painted with one coat of red oxide with erection on site as
per direction of engineer in charge with necessary
grouting, cementing, plastering & finishing complete.
167 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured 214.00 Mtr. 126.25
cable Aluminium conductor for 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe of
following size of cables. (C) 2 core 10 Sq. mm
18 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
168 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured 196.00 Mtr. 220.18
cable multistrand Aluminium conductor for 1.1 KV. to be
laid on wall with necessary clamps or in existing trench /
pipe of following size of cables (B) 3 1/2 core 35 Sq. mm (
16 Sq. mm 1/2 core)
170 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured 474.00 Mtr. 126.25
cable multistrand / Solid Aluminium conductor for 1.1 KV.
to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables (B) 4 core 6 Sq.
171 Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured 134.00 Mtr. 153.52
cable multistrand Aluminium conductor for 1.1 KV. to be
laid on wall with necessary clamps or in existing trench /
pipe of following size of cables (A) 4 core 16 Sq. mm
172 Making trench in soft soil of suitable width of 90 cm deep 631.00 Mtr. 55.55
for laying cable or locating the fault all over the run and
back filling the same and making the surface as normal
173 Supplying following size of Light duty “A” Class G.I . Pipe 42.00 Mtr. 300.98
& erecting as directed by Engineer-in-charge. (B) 50 mm
174 Providing & laying approved make Double walled 907.00 Mtr. 62.62
corrugated pipes (DWC) of polyethylene(conforming to IS
14930 II )with necessary connecting accessories of same
material at required depth in existing trench for laying of
cable. below ground / road surface for enclosing cable
(A)50 mm outer dia
175 Providing and, fixing heavy duty flange type brass cable 7.00 Ea 38.38
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables. (B) 2 to 4 core 6 Sq. mm
176 (C) 2 to 4 core 10 Sq. mm 3.00 Ea 38.38
177 (D) 2 to 4 core 16 Sq. mm 2.00 Ea 47.47
178 Providing and, fixing heavy duty flange type brass double 9.00 Ea 75.75
compression type cable gland with rubber ring for PVC
insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables.(B) 3 & 1/2
core 35/50 Sq. mm
179 Solder less crimping type Aluminium lugs conforming to 17.00 Ea 15.15
IS suitable for cable of following size evenly crimped with
high pressure tool & connected to switchgear terminals
with brass/cadmium plated nut bolts in an approved
manner. (C) 16/25 Sq.mm.
181 Solder less crimping type Copper lugs conforming to IS 8.00 Ea 8.08
suitable for cable of following size evenly crimped with
high pressure tool & connected to switchgear terminals
with brass/cadmium plated nut bolts in an approved
manner. (A) 1.5/2.5 to 6 Sq.mm
182 Providing & erecting Approved make Power Saving 50 79.00 Ea 1948.29
Watt Ceiling Fan with double ball bearing ISI mark with
Condenser 230 volt A.C. 50 Hz 1200 mm sweep complete
having 3blades with aluminium blades with , canopy &
cm. down rod erected with earthing.(Make shall be
approved by Engineer in charge))
183 Supplying and erecting 19 / 20 mm. nominal bore Medium 40.00 Mtr. 108.07
Class M.S. Pipe down rod erected duly painted for fan
complete with proper insulation without leakage and
184 Supplying & erecting fan hook box of 10 mm M.S. round 79.00 Ea 108.07
bar bounded to the RCC bars up to 50mm length each
side and pierced through a 16 Gauge M.S. box / Heavy
Duty PVC box complete erected concealed in Ceiling with
necessary finishing.
19 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
185 Providing 2.5mm.thick laminated acrylic sheet to cover 79.00 Ea 18.18
the fan hook or Fan box.
186 Supplying & erecting approved make low noise 29.00 Ea 1703.87
decorative exhaust fan having square frame ABS body
with inbuilt lowers & square frame. 200mm with 1350RPM
187 Supply of approved make FRP Pole having following 12.00 Ea 14059.20
specifications: FRP Light Pole made by CNC filament
winding machine using thermoset resin polyester/epoxy
resin system) having minimum 62% glass content. The
pole should be in one piece and tapered round in shape,
having smooth finish and should be totally free from
corrosion as well as non conductive & shock proof Pole
should be provided with FRP Anchor Base and it should
be heavy duty, or MS Material duly painted with Epoxy
paint.Pole should be flame retardant as per IS 6746. Resin
used shall be UV resistance and pigmented. A highly
weather resistant polyurethane coating shall be applied
to the pole after applying suitable primer system that
ensures proper adhesion of the paint. Minimum coating
thickness shall be 80 to 100 micron. Deflection of the pole
shall not exceed more than 10% of the length of pole for
the given load“ Pole should be generally made as per the
dimensional data, performance criteria and some
interchangeability features of poles as per standard ANSI
C 136.20 latest version or ASTM D 4923/01 including
cable termination box with necessary accessories . The
size of pole and type of installation with foundation as per
manufacturer details and site requirement are as below
.(1) Suitable for base plate mounting single arm Bracket.
[H] Overall length of 6 Mtr. Average Thickness: 7.5mm
Top/ Bottom OD Dia A/F 89mm ± 2mm approx. approx.
Weight of Pole 32 kg approx. (Without Base) Anchor Base
(Size 300X300 & 18mm Th.)
188 (2) Suitable for base plate mounting Double arm Bracket. 6.00 Ea 14894.47
[C] Overall length of 6 Mtr. Average Thickness: 8mm.
Top/ Bottom OD Dia A/F 114/174 mm ± 2mm approx.
approx. Weight of Pole 38 kg approx. (Without Base)
Anchor Base (Size 300X300 & 18mm th.)
189 Providing FRP arm bracket of having 2 sets of suitable 12.00 Ea 2551.26
SS304 hardware for fixing the brackets & spread of
Mtr(Suitable for 89 to 114 mm pole top dia) (A) Single arm
190 (B) Double arm bracket 6.00 Ea 3933.95
191 Supplying & erecting approved make SMC press 5.00 Ea 476.72
moulded composite FRP. loop-in, loop-out approx. 2mm
thick box complete with Bakelite connector strip
5way(3P+N+E),DIN rail for mounting mob & hinged doors
as per requirement having locking arrangements with
mounting clamp with nuts, bolts & washers suitable for
erection on pole with cable clamps& earth bolt of
following size of box.(C)150mm x 125mm x 100mm [deep]
192 Supplying & erecting approved make Digital time switch 1.00 Ea 3168.37
having lithium cell 6 years operative and operate battery
backup 1 channel day clock with 14 memory programme,
suitable to operate on 240V + 5%, 16A with, floating
contacts Minimum switching setup time 1 minimum & LCD
display. Also comprised permanent ON/OFF switching.
Programming switches & housed in fire proof
thermoplastic enclosure & transparent cover erected as
required with necessary connection erected as directed.
20 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
193 Supplying & erecting power contactor ,AC3 duty for time 1.00 Ea 2782.55
switch complete erected as per direction Cat III (D)
pole 440V 40 Amp.
194 Providing & erecting water cooler having storage 4.00 Ea 55893.40
capacity 150 Ltr. & cooling capacity 150 Ltr.per hour @
an ambient temp of 45˚ C. The outlet temp. of the water
should drop by 15˚C within a hour, The water cooler
should be comprising of hermetically sealed compressor,
fan motor, condensing unit, water tank surrounded by
evaporating, coil, thermostats, relay etc.complete with
necessary inlet & outlet connection. The body of water
cooler will be made from Stainless Steel.
195 Supplying & erecting 5 stage single reverse osmosis 4.00 Ea 29187.99
water purification system with M.S. powder coated frame,
prefilter housing with 'O' ring presediment filter GAC
filter, carbon filter suitable buster DC pump capacity
psi, mention with 40 psi inline type post carbon filter auto
low & high pressure switches with following size of
storage tank & LPH capacity & erected as directed [C]
Ltr / Hr with 150 psi 2 nos booster pump
196 Supplying and erecting horizontal / vertical mounting type 21.00 Ea 11455.42
storage water heater with copper container housed in
M.S./S.S./ABS body insulated with glass wool/puff
complete with heating elements,adjustable thermostats
300C to 850C, indicating lamp, safety valve, fusible plug,
etc.complete erected with coach bolts, nuts. washers &
cementation (C)25 Ltr. with 2 KW. heating element
Premium Category (Racold,A.o.Smith,Venus)
197 Providing & Erecting new water level Sensor for 50 Ltr. 4.00 Ea 864.56
198 Supplying and erecting approved make panel mounting 2.00 Ea 1275.63
type Digital Voltmeter having 3 digits LED display, 0 to
750 AC Volts range erected on existing panel board with
all connection, wiring etc .with manufacturers calibration
199 Supplying and erecting approved make panel mounting 2.00 Ea 1558.43
type Digital Ammeter having 3 digits LED display,
external CT operated, calibrated for 0 to 1000 Amps
suitable to operate on 500 Volt AC , erected on existing
panel board with all connection, wiring etc .with
manufacturers calibration certificate.
200 Supplying and erecting Ammeter / Voltmeter selector 4.00 Ea 317.14
switch for 3 phase AC Supply 500 V on existing panel
board with necessary connections.
201 Providing & erecting L.T. Current Transformer with bar 6.00 Ea 274.72
primary 50/5 to 1000/5 ratio 15 VA burden erected in
existing CRCA box duly secured with insulating materials
connected to the meter
202 Supplying and erecting approved make suitable panel 6.00 Ea 43.43
indicator LED type lamp, lens cover, complete erected
with necessary connections.
203 Providing & erecting open well horizontal mono block 2.00 Ea 18746.61
pump set with cast iron body, complete for three phase
submersible motor having[D] For 5 HP 3 phase open well
horizontal mono block pump set suitable for 1350 LPM to
310 LPM @ 10 to 42 Mtr head suitable for 50/65 mm dia
delivery pipe Cat-II
21 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
204 Supplying & erecting approved make motor control 3.00 Ea 7722.46
cubical panel (Direct - on - line) made from 16 G. CRCA
sheet duly epoxy powder painted inside and outside with
hinged doors and locking, arrangement consisting of
suitable size of ON- OFF isolator (AC - 3/23duty) main
fuses, single phasing preventer, indicating lamps for R- Y -
B phases, overload relay, Automatic water level
controller, Ammeter, Voltmeter each with two way
selector switch incoming, wires duly socket crimped,
main contactor & overload relay, start - stop push
buttons, to be erected on angle iron frame grouted on
wall as directed. The isolator, overload relay & contactors
will be of L & T, Siemens or BCH make only. (A) DOL up to
205 S.I.T.C. submersible pump set suitable for bore of 100 1.00 Ea 22374.53
mm. dia. or more having three phase motor capacity not
more than 5 H.P. with following capacity Lifting and
Lowering taken extra. (B) (16 stage) 140 to 180 LPM
discharge at 96 to 69 mtrs. head respectively suitable for
50mm dia. delivery pipe Cat III
206 Lowering of submersible motor pump set at the depth of 1.00 Per Job 2568.43
following ,complete with required. Nos. and size of casing
pipes erected by means of proper chain pulley block &
pipe wrenches after checking of threads of each pipe with
coupling to take the load of the pump set and pipe
assembly filled up with water (B) Above 60 mtrs. and Up
207 Providing and erecting ISI marked PVC insulated PVC 160.00 Mtr. 146.45
Sheathed Flat flexible Submersible copper cable
approved make of following Size.(C) 3 Core x 4 Sq. mm
208 Providing Water proof straight Joint in PVC insulated flat 3.00 Ea 189.88
flexible copper cable by using insulating material, water
proofing material, & making the joint complete. (A) Up to
209 Supplying of following size of HEAVY UPVC column pipe 96.00 Rn. Mtr 359.56
with coupler and wire lock [B] 50 mm dia
210 Supply of following size of TOP & BOTTOM accessories 1.00 Per Set 1489.75
i.e. Adaptor set (CI) long, pump guard set, starter pipe
Rubber ring for submersible pump & UPVC column pipe
as directed by Engineer - in - charge with necessary
plumbing as desired. [D] 50 mm dia
211 Supplying and erecting, commissioning and testing of 1.00 Ea 675844.53
Diesel Generating set confirming to IS: 4722:1968 &
BS:5514 having continuous rating, 3 phase, 415 volts,
cycles A.C. supply comprising of a totally enclosed
air/water cooled diesel engine with multi-cylinders
developing suitable BHP not less than following capacity
at 1500 RPM with 10% overload for one hour in 24 hours
with standard accessories like fly wheel, lubricating oil
cooler, "A" class governor, heavy duty fuel wheel and
lubricating oil filter, oil bath air filler, lubricating oil
pressure gauge, end exhaust manifold, standard set of
tools with adjustable spanners, screw drivers, cylinder
head to cover, joint cylinder head to exhaust, element
lube oil filter, 12 / 24 volts electric starting equipment
complete with standard heavy duty battery, dynamo, cut-
outs, ammeter, necessary wiring, pressure gauge, starter
etc and heavy duty Residential type exhaust silencer
(With DEF System) and vertical hot air duct both
22 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
logged with asbestos rope, save oil trays, exhaust piping
of required length, standard wall/floor mounted fuel with
level indicator and piping and drip proof alternator, self
excited, self regulated, screen protected, with excitation
system, capable of delivering the rated system output at
415 volts, 3 phase, 0.8 PF, 50 Hz, 4 wire, running at
RPM, conforming to IS-4722- 1968 with voltage regulation
+/- 5% of rated voltage from no load to full load. Both the
engine and alternator fitted on a common fabricated steel
base plate with antivibration mounting engine and
alternator both connected to each other by flexible flange
coupling and with floor/wall mounted control panel box
comprising of voltmeter ammeter, selector switches,
ACB / MCCB / MCB of adequate capacity, indicator lamps
duly wired with HRC fuses. The alternator & control panel
shall be connected with provided suitable capacity
armoured cable and complete with Acoustic enclosure
(canopy) made out of 16 SWG CRCA Sheet, sound
absorbing material Rockwool of 64 density & 100 mm
conforming to IS:8183 / PU Foam of 40 Density - at least
40 mm. The resin bonded rockwool covered from inside
the canopy by perforated sheet with 3/4 mm holes, sound
level not more than 75 dB at a distance of 1 mtr, as per
PVCT norms.DG set should have in built fuel tank capacity
of minimum 8 hrs of continous running capacity on full
load . Erection, commissioning and satisfactory testing as
per requirement with first filling of fuel (minimum up to the
80% of fuel tank capacity), oil, etc. with guarantee /
Warrantee of complete system for Two years. & with
obtaining all necessary certificate from Electrical
Inspector. The Capacity and Ratings of DG sets are as
below. (As per new CPCB4+ Emission norms Engine With
- Turbo Charger, EGR (Exhaust Gas Recirculation), CRS
(Common Rail Fuel System), DOC (Diesel Oxidation
Catalyst), SCR (Selective Catalytic Reduction), Integrated
wiring harness connected to ECU .) (I) Continuous Rating
of 62.5 KVA ,BHP not less than 76 BHP
212 AMF panel Providing & erecting approved make AMF 1.00 Ea 97320.57
control panel suitable for following size of 3 phase,
V., 50 cycles, A.C. diesel generating set complete of
scope as detailed below: 1) Power module: A pair of
electromechanically interlocked contactors (for mains &
generator) Overload relay for generator contactor
Neutral contactor for mains and generator Power socket
for connections.2) Control and metering module: Line
voltage monitor. Generator voltage monitor Ammeter
items attempt start facility. Air circuit
breakers/MCB/MCCB of suitable rating for auto/manual
operation. Auto/manual switch. Emergency stop push
buttons. Manual start push button. frequency meter.
Engine hour meter. Two earthing studs.3) Protection
module: The engine shutdown in the unlikely event of Low
lube oil pressure High cylinder head temperature. V belt
failure. 4) Indicators with alarm Load on generator.5)
Indicators Load on mains Engine fails to start .
Emergency stop battery charger. The AMF Panel of
following capacity (A) AMF Control Panel for 50/62.5 KVA
23 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
213 Supply, Installation, Testing & Commissioning of following 40.00 Per KW 42156.39
size of Grid Tied Solar Power Plant with
Solar Panels (ALMM approved): Frame Material :
Anodized Aluminum alloy Frame With Twin Wall Profile,
Front Cover : High Transmission Low-Iron Tempered
Glass (AR Coated), High efficency and positive power
tolerance Pmax: 0/+5, Module Efficiency should be
approx. 19.5%-22%, Normal operating temperature 45'C,
Junction Box with Waterproof IP67 & MC4 Compatible and
Enclosed with Bypass diodes, 100% Electroluminescence
test to ensure error free Modules, Thep. temp. co-efficient
of the PV module shall equal or better than -0.45%/degree
C. Solar PV modules of minimum fill factor 75% to be
used. Unit Production:- More than 4.5 Unit /kw /day
(Actual)(1Year Avg) With 10 year Product warranty and
year Linear Power Warranty includes all mechanical and
electrical parameters of the Solar panel. Modules must be
complied to the DCR(Domestic content requirements).
The Ration of AC to DC is 5:6 for the Installation capacity
which are given in AC KW.
Solar Inverter: MPPT Range: MPPT Range: 80-1000 V
Max efficiency: 97.5% - 98.9%, O/p Frequency: 50/60Hz,
Operating Altitude (m) ≤4000, O/p Power Factor: ~1, O/P
THDi: <3%, Operating Tempreture Range: -25~60°C,
Integrated protection of Inverter are Anti-islanding
Protection, Input Reverse Polarity Protection, Insulation
Resistor Detection, Ground fault protection, Residual
Current Monitoring Unit, Output Over Current Protection,
Output Short Circuit Protection, Output Over Voltage
Protection, PV array string fault Protection. Protection
Degree: IP65, User Interface LCD & APP, Datalogger &
Communication: GPRS / Wi-Fi.Integrated, Input Reverse
Polarity Protection Integrated, Insulation Resistor
Detection Integrated, Residual Current Monitoring Unit
Integrated, Output Over Current Protection Integrated,
Output Short Circuit Protection Integrated, Output Over
Voltage Protection Integrated, Protection Degree: IP65,
User Interface LCD & APP,Datalogger & Communication:
GPRS / Wi-Fi, Module Mounting Structure:
The mounting (Rectangular pipe / square pipe / circular
pipe) with requisite cross bars, nuts and bolts, etc. shall
be Hot deep galvanized with minimum 80micron coating.
The Rectangular / square /circular hollow pipe section
used for the structure should have a minimum thickness
of 2.0 mm. other than above, the material thickness
should be minimum 2.5 mm. A certificate of a structural
engineer certifying the strength and stability of the
mounting structure to withstand the weight and wind
speed of 150 km/hour throughout the life span of 25 years
of the system, shall be submitted by the vendors. Hot
Dipped Galvanized steel coils. suitable arrangement for
base plate for foundation , solar panel mounting, the
structure should be suitable for carry the load of solar
panel,wiring, sprinkler system etc. with necessary
foundation work/wall mount, j bolt, anchor fastner etc. the
nut bolt used for installtion of stucture should be (SS 304)
quality.The ground clearance of the bottom most edge of
solar panel shall not be less than 300 mm to 1200 mm or
as per site’s technical/feasibility requirement.
24 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
a. Column –The minimum section (thickness) should be
b. Rafter - The minimum section (thickness) should be
c. Purlin - The minimum section (thickness) should be
40MM * 40MM Balane of System with necessary
Swichgears (Suitabel size and protection of ACDB &
DCDB), inter connecting wiring, earthing system as per
the CEIG drawing approval, lightining arrester system as
per the CEIG drawing approval, all liasoning work with
various gov. dipartment like state nodal agency,DISCOM
& CEIG is included in agency scope (Excluding All
charges namely GEDA Application fees, Solar
connectivity Charges, Meter connectivity Charges, Meter
testing Charges and system stability/strenthning
charges.) (D) Grid Tied Solar Power System: 26 - 50 kW (3 -
Total of Ele Items (B) Rs.
Total of (A)+ (B) Rs.
Amount of my tender work out as under
I / We am/are willing to carry out the work at ………………………………………….. % above / below
Percent [should be written in figures and words] of the estimated rates mantioned above. Amount of
my/our tender works out as under
Estimated Amount Put to tender: Estimated Amount Put to tender:
Deduct % below Add % above
Net Rs. Net Rs.
In words : In words :
Signature of Contractor
Deputy Executive Engineer Executive Engineer
City (R&B) Sub Division Jamnagar (R & B) Division,
Jamnagar Jamnagar.
25 of 26 DTP of Tribal Hostel Bldg 06-26
Sr. Description of Item (With brief specification Quantity Unit Rs. In figure Amount
No. and reference to book of specifications)
1) The work shall be carried out as per Public Works Department Hand Book, I.S. Specification and
other specification of the Division or as Directed.
2) All the columns in Schedule should be filled in INK and the total of the entries in the last column
should be strike out by the Contractor under his Signature.
3) Rates should include clearance of site (Prior to commencement of work and its close) in all
respect and good for work under all conditions of site moisture weather etc.
4) The Contractor shall exhibit the details of works, Tenders amount and specification as per Govt.
Circular No. TD 32772 N. Dt. 26-4-78 and as per G.R. No. TNC-9-24-C, Dt. 18-11-91, as directed by
Engineer-in-Charge of the works, on board at site of the work.
5) Contractor shall even "NIL" percentage, if no deduction is offered.
6) Testing of materials shall be as per statement attached with the specification. The material shall
be tested in GERI Bill for the testing shall be paid by the Executive Engineer and 1% of amount put
to tender after deducting the cost of materials to be supplied by Department as per SCHEDULE
'A' at the sanctioned estimate rates from the Contractor in Running Bills. (As per G.R.No. (R&B)
TNC-1085/4/C Dt. 20-12-91 and modified ide (R&B) Deptt. Circular No. SSR/10000092-IB-12910-C
7) For R.C.C. Item where there is change of grade mix or charge as per actual mix design the
difference of cement consumption shall be deducted from rate of original item at the rate of star
rate mentioned in the tender.
8) 1% L.C. shall be deducted from the bill as per agreement.
9) GST will be paid extra as per Govt. Emendment.
10) GST and Income tax will be deducted at source while making payment of bills
Signature of Contractor
Deputy Executive Engineer Executive Engineer
City (R&B) Sub Division Jamnagar (R & B) Division,
Jamnagar Jamnagar.
26 of 26 DTP of Tribal Hostel Bldg 06-26
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1- GOVERMENT OF GUJARAT.pdf
Civil specification of Tribal Hostel Bldg 06-26.pdf
Drawing.pdf
E-Tender-12.pdf
index to specification.pdf
make list for ELE item.pdf
MOU Electric.pdf
price bid.pdf
SBD - Annexure - Const. of Boys Hostel Tribal Jamnagar.pdf
SBD of Tribal Hostel Bldg 06-26_11zon.pdf
Specification -Boys Hostel AND canteen Building of Tribal.pdf
Test Sch.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].