| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC MOTHER TERESA ROAD ZOO TINIALI GUWAHATI 781024 | GUWAHATI | KAMRUP METRO | ASSAM | 781024 | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.5 L+₹33,905 (5.50%)Rejected-Finance TUPKHANA PART 1 PO ARUNACHAL PS SILCHAR DIST CACHAR ASSAM 788025 | CACHAR | ASSAM | 788025 | L2 | Rejected-Finance L2 |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
29 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I AFS Kumbhirgram
AGE I AF Kumbhirgram Military Engineer Services PO Kumbhirgram Assam Pin 788109 Tele 03841282376
REPAIR REPLACEMENT MAINTENANCE OF COLLING APPLIANCES AT AF STN KUMBHIGRAM UNDER AGE I AF KUMBHIRGRAM
2020_MES_361697_1
8310/2020-21/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STATION KUMBHIRGRAM
As per NIT
8 documents required · 8 mandatory
₹500
Yes
AGE I AF Kumbhirgram
₹16,000
Yes
21 Sept 2020
17 Jul 2020
30 Jul 2020
17 Jul 2020
29 Jul 2020
17 Jul 2020
60 days
Amount
Taking down existing window type AC upto 1/1.5/2 TR from different location for servicing of complete Air conditioner including replacement of rubber mounting bush for compressor, bakelite connector, cleaning and washing of Air filter, suitable sized brass/copper lugs, small nuts bolts, screws, etc of suitable size and greasing of fan motor, checking of any leakage of gas/cooling coil/condenser unit/compressor unit etc, incl removal of rust/dust and re fixing the same after satisfactory testing complete all as specified and as directed.
All as per item No 1.00 here-in-before, but 1.5/2.0 TR split type Air Conditioner.
Supply and fix running capacitor 45 MFD +5% suitable for split/window type ACs including taking out of old unserviceable capacitor, complete all as specified and as directed. Make: Universal/Sarada/whirlpool/Tibcon
All as per item No 3.00 here-in-before but for capacity 45 MFD with 4.0 Mfd fan capacitor
All as per item No 3.00 here-in-before but for capacity 55 MFD with 6.0 mfd fan capacitor
Supply and fixing window/split type AC thermostat switch AC-230 Volt, single phase to match the existing one including taking out old unserviceable thermostats complete all as directed Make : INDFOSS/ RANUTROL/WHIRLPOOL/ANNAPURNA
Supply and fix magnetic controller assembly of any shape and type/model to suit the existing window/split A/Cs including taking out old unserviceable assembly, complete all as directed. Make : JKB/OM/BABA
Materials and labour for charging of gas R-22 for window/split type AC, complete all as specified and as directed.
Materials and labour for charging of gas R-134 A for Refrigerator, complete all as specified and as directed.
Supply and fix remote sensor circuit board for1.0/1.5 TR split type Air Conditioner including taking out old U/S PCB, complete all as specified and as directed.
Supply and fix remote sensor circuit board for 2.0 TR split type Air Conditioner including taking out old U/S PCB, complete all as specified and as directed (As per sample/As per Make of ACs).
Supply and fix capacitor 220 volts 6.0 MFD suitable for window/split type AC/Refrigerator/Water cooler. Make : UNIVERSAL/SARADA/BAJAJ/Whirlpool/Tibcon/
Supply and fix capacitor 220 volts 3.15/4.0 MFD suitable for window/split type AC.Make : UNIVERSAL/ SARADA /Whirlpool/JKB/Tibcon
Supply and fix capacitor 220 volts 1.5/2.0 MFD suitable for window/split type AC.Make : UNIVERSAL/ SARADA/JKB/Tibcon
Supply and fix in repairs foam for covering copper pipe for split type AC of internal dia 20 mm, complete all as specified and as directed.
Supply and fix in repairs foam for covering copper pipe for split type AC of internal dia 12 mm, complete all as specified and as directed.
Supply and fix in repairs copper pipe 12 mm dia for split type AC 1.5 /2 Ton, complete all as specified and as directed.
Supply and fix in repairs copper pipe 6 mm dia for split type AC 1.5/2 Ton, complete all as specified and as directed.
Supply and fix in repairs fan motor indoor unit of split type AC 1.5/2 Ton (As per sample), match to existing motor complete all as specified and as directed.
Supply and fix in repairs fan motor of window type AC 1.5 Ton (As per sample), complete all as specified and as directed.
Supply and fix thermatically sealed compressor with Refrigerant Gas suitable for 230 volts, AC, 50 Hz, suitable for upto 1/1.5 TR capacity window/split type AC. Make :- HITACHI/ CARRIER/ LG/TOSHIBA/Whirpool/GMCC
Supply and fix thermatically sealed protected compressor with Refrigerant Gas suitable for 230 volts, AC, 50 Hz, suitable for 2TR capacity split type AC. Make :- HITACHI/SAMSUNG/ CARRIER/LG/ TOSHIBA/Whirpool/GMCC
Supply and fix relay any type suitable for upto 310 Ltrs. capacity refrigerator including removing of old unserviceable relay any type complete all as specified and as directed. Make: Ranutrol/ Whirlpool or equivalent as approved.
Supply and fix thermostat switch suitable for refrigerator of any capacity including removing of old unserviceable thermostat switch ,complete all as specified and aRanutrol/ Whirlpool or equivalent as approved.INDFOSS/RANUTROL/SARADA or equivalent as approved
Supply and fix over load protector suitable for refrigerator upto 310 Ltrs capacity to match with the existing design and taking out of old unserviceable over load protector (OLP) , complete all as specified and directed. (Make : INDFOSS/RANUTROL/SARADA) or equivalent as approved
Supply and fix pigmy lamp holder & lamp case to match with the existing, suitable for refrigerator of any capacity including taking out of unserviceable lamp holder including lamp case, complete all as specified and directed (Make : INDFOSS/RANUTROL/SARADA) or equivalent as approved
Supply and fixing in replacement of Capillary pipe 3mm dia for use in Refrigerator and Air Condition of any type and make, complete all as specified and as directed.
Supply and fix thermatically sealed compressor with Refrigerant gas (R-134a), 230 volts, AC, 50 Hz, suitable for refrigerator of any capacity, complete all as specified and as directed. Make :- WHIRLPOOL/GODREJ/SAMSUNG/CARRIER/LG
Supply and fix running capacitor (25 MFD) to match with the existing water cooler including taking out unserviceable running capacitor, complete all as specified and as directed Make : UNIVERSAL/SARADA/RANUTROL
Supply and fix starting capacitor (60-80) MFD to match with the existing for 40/ 80 Ltrs capacity water coolers including taking out unserviceable starting capacitor, complete all as specified and as directed. Make : UNIVERSAL/SARADA/RANUTROL/WHIRLPOOL/TIBCON
Supply and fix relay 1022 suitable for 40/ 80 Ltrs capacity water coolers including taking out unserviceable relay , complete all as specified and as directed. Make : UNIVERSAL/SARADA/RANUTROL
Supply and fix OLP for 40/80 Ltrs capacity water cooler including taking out of unserviceable OLP, complete all as specified and as directed. Make : UNIVERSAL/SARADA/RANUTROL
Supply and fix thermostat switch for water cooler of any capacity including taking out unserviceable thermostat switch complete all as specified and as directed Make : UNIVERSAL/SARADA/RANUTROL/WHIRLPOOL/ ANNAPURNA
Supply and fix strainer round type of approved quality to match the existing water cooler/refrigerator including taking out of old unserviceable strainer, complete all as specified and as directed.
Supply and fix 32 mm dia, 100mm long drain pipe for water cooler to match with the existing pipe for any capacity of water cooler including taking down worn out drain pipe complete all as specified and directed.
Supply and fix self closing type bib tap of stainless steel for water cooler of suitable size to match with the existing tap including washers, etc complete all as specified and as directed
Supply and fix thermatically sealed compressor unit with refrigerant gas (R-134a) 230 volts, AC, 50 Hz, suitable for Deep Freezer of 200/300 ltr capacity , complete all as specified and as directed Make : UNIVERSAL/SARADA/RANUTROL/WHIRLPOOL/ ANNAPURNA Make: WHIRLPOOL/GODREJ/SAMSUNG/CARRIER/LG
Material and labour for repair of voltage stabilizer single phase AC 230 Volt, 5KVA capacity by replacing unserviceable circuit board, relay carbon brushes, control switches, indicator & voltmeter etc including one coat of synthetic enamel paint in existing colour, complete all as specified and as directed.
All as per item No. 42.00 here-in-before but 4/3.15 KVA capacity.
All as per item No. 42.00 here-in-before but 1/2 KVA capacity.
Supply and fix Metal Plug top, 3 pin, 20 Amp, 230 volts, (ISI marked), complete all as specified and as directed. Make: HAVELLS/L&T/LEGRAND
Supply and fix Metal Plug & socket , 3 pin, 20 Amp, 230 volts, (ISI marked) with 20 Amp SP MCB 'C' Curve complete all as specified and as directed. Make: HAVELLS/L&T/LEGRAND/ ANCHOR (PENTA)
Supply and fix PVC Plastic Pipe for drainage of waste water of Split AC with proper hooking on wall all as specified and as directed
Supply and fix plug top, 3 pin, 15 Amp, 230 Volts, (ISI marked), complete all as specified and as directed.Make: ANCHOR (PENTA)/MARU/HAVELLS
Supply and fix plug top, 3 pin, 5 Amp, 230 Volts, (ISI marked), complete all as specified and as directed. Make: ANCHOR (PENTA)/PLAZA/MARU/HAVELLS
Material and labour for taking down window type AC along with all accessories, including disconnecting and making good the existing wall and depositing the same to the store yard of AGE E/M, complete all as specified and as directed.
Material and labour for taking down split type AC along with out door unit and all accessories, including disconnecting and making good the existing wall and depositing the same to the store yard of AGE E/M, complete all as specified and as directed.
Material and labour for fixing window type AC incuding making hole in wall and making good surfaces including necessary clam nut and bolt,lugs and cleaning of unit, connecting and testing complete for two hours with entire satisfaction of Engr-in-charge, complete all as specified and as directed.
Material and labour for fixing split type AC incuding making hole in wall and fixing230mm long, 75mm bore PVC pipe and making good surfaces, including necessary clam nut and bolt,lugs and cleaning of indoor and out door unit, connecting and testing complete for two hours with entire satisfaction of Engr-in-charge, complete all as specified and as directed.
M/S R A ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .