Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.5 CrAccepted-AOC 32 9 EC ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | ₹42.5 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹43.2 CrRejected-Finance E 44 GROUND FLOOR SECTOR 36 GREATER NOIDA G B NAGAR UP | ₹43.2 Cr | L2 | Rejected-Finance Highest Rate Quoted by bidder |
| 3 | Rejected-Technical GROUND FLOOR SECTOR 15 PANCHKULA 2943 PANCHKULA 134109 INDIA | PANCHKULA | PANCHKULA | HARYANA | 134109 | - | - | Rejected-Technical Non Technically Qualified |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not Technically Qualified |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-Physical Document not submitted by the bidder. |
Tender Value
₹42.7 Cr
EMD Value
₹67.7 L
Closing Date
12 May 2025, 5:00 pmClosed
General Manager
Office of Chief General Manager, Construction Wing, Uttarakhand Peyjal Nigam, Kamla Nagar(Opp. ONGC Hospital), Dehradun
PROPOSED OFFICE BUILDING OF GRAMYA VIKAS VIBHAG, SAHASTRADHARA ROAD, DEHRADUN
2025_MDPEY_82598_1
1349/ Nivida(Garh)D.Dun/33 Dt 07-04-2025
Open Tender
Civil Works
540 days
SAHASTRADHARA ROAD
Please refer tender document
3 documents required · 3 mandatory
₹11,800
PM, Const.Unit, UKPJN, Dehradun
₹67.7 L
Dehradun
2 Jul 2025
9 Apr 2025
16 May 2025
9 Apr 2025
12 May 2025
12 Apr 2025
11 Apr 2025
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. :All kinds of soil.
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil
Open timbering over areas including strutting, shoring etc. complete. (Measurements to be taken of the face area timbered): Depth exceeding 1.5 m but not exceeding 3 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Disposal of Excavated earth/rock unserviceable, upto dumping zone near national highway distance upto 10km from site.
Diluting and injecting chemical emulsion (Chlorpyriphos/ Lindane E.C. 20% with 1% concentration), at the rate of one litre per hole at 300 mm c/c to all the horizontal and vertical surfaces of the excavations made for the foundation of the building, soil under floors, apron, back fill material and along all the faces of the walls for PRE-CONSTRUCTIONAL anti-termite treatment (including the cost of chemical emulsion) as per IS:6313 Part-II. (Plinth area of Building shall be measured for Payment)
P/L cement concrete - all works upto plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
P/L cement concrete - all works upto plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
P/L cement concrete - all works upto plinth level : 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
P/L cement concrete - all works upto plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 40 mm nominal size)
Providing and laying M-30 grade BMC/ RMC for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works upto plinth level
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. : All works upto plinth level: for foundation, Raft etc.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works above plinth level upto floor V level
P/L RCC M30 design mix for columns, pillars piers etc. All works above plinth level
P/L RCC M25 design mix in lintel beams and girders etc. All works above plinth level
P/L RCC M25 design mix for suspended floor, balconies etc. All works above plinth level
P/L RCC M25 design mix for Staircase etc. All works above plinth level
P/L RCC M25 design mix for Chajjas All works above plinth level
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for : intels, beams, plinth beams, girders, bressumers and cantilevers.
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for : Stairs, (excluding landings) except spiral-staircases
Weather shade, Chajjas, corbels etc., including edges
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters,butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform, with water proof ply 12 mm thick
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof. :Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars
Providing and filling in position, blown bitumen in expansion joints
Providing and fixing sheet covering over expansion joints with iron screws: Aluminium fluted strips 3.15 mm thick. 200 mm wide
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
P/F Pressed steel door frames manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, Profile C
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
P/F ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters A) 35 mm thick including ISI marked Stainless Steel butt hinges
Providing and fixing ISI marked Bright finished M.S. fitting for door windows. 250x16x5 mm sliding door bolts
Providing and fixing ISI marked Bright finished M.S. fitting for door windows. 250x10 mm Tower bolt
Providing and fixing ISI marked Bright finished M.S. fitting for door windows. 150x10 mm Tower bolt
Providing and fixing ISI marked Bright finished M.S. fitting for door windows. 125 mm handles
Providing and fixing ISI marked Bright finished M.S. fitting for door windows. 100 mm handles
hanging floor door stopper, Twin rubber stopper
200 Casement stays (straight peg type) with necessary screws etc. complete, weighing not less than 120 gms
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Providing and fixing 12 mm thick frameless toughened glass Fixed and door shutter of approved brand and manufacture, including providing and fixing Door handle, lock and stopper, top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge.
Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Three track three panels sliding door with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on two panels along with multi-point locking system, adjustable nylon rollers with SS 304 body. Using R3 series with frame (98 mm & above) x (40 mm & above) & both glazed and fly screen sash (30 mm & above) x (74 mm & above). (Height upto 2.5 metre).
Providing and fixing glazing in uPVC/aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm)
Filling the gap in between uPVC, aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete: Upto 5mm depth and 5 mm width
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete: Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides
Providing and fixing M.S. Tubular frames for Doors with rectangular/ L-Type sections, made of 2.0 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer: Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
Providing and fixing MS standard rolled steel glazed windows of required sizes side hung, top hung or fixed in position with CC block of size 15x10x10cm with all fittings.
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 12 mm mild steel U beading
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 5.5 mm thick glass panes
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi- etallic contacts, all complete to perform as per Specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.
Steel work in built up tubular ( round, square or rectanglar hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required : In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make,in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as pecified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete.
Cement plaster skirting 18 mm thick up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.
Extra for making chequers of approved pattern on cement concrete floors, steps, landing, pavements etc.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
52 mm thick C.C. flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4
Providing and fixing GI Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing ‘C’ wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of GI steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring ‘T’ with : GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holesand having NRC of 0.5, electro statically polyester powdercoated of thickness 60 microns (minimum), including factory painted after bending and perforation.
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.
P/F corrugated G.S. sheet roofing i/c vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia. 1.00mm thick with zinc coating not less than 275gm/m
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gm/m²
P/F 15 cm wide 45 cm over all semi circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc. 0.63 mm thick with zinc coating not less than 275gm/m
Providing and fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Rockwool conforming to IS: 8183,density 48 kg/ m3, 50 mm thick, wrapped in 200 G Virgin Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building.
P/L integral cement based treatment for water proofing Using rough kota stone on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course, Joints sealed and grouted with cement slurry mixed with water proofing compound. 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.
Providing and laying integral cement based treatment for water proofing Using rough Kota stone on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) -
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand)
6 mm cement plaster 1:3 (1 cement: 3 fine sand)
12mm C.P. finished with a floating coat of neat cement in cement mortar 1:4( 1 cement : 4 fine sand)
20 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
Applying priming coat : With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water tinnable priming coat with cement primer
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarsesand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :
Providing gola 75x75 mm in cement concrete (1:2:4).
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm
P/L 110 mm dia UPVC soil waste pipe with pressure 6kg/CM2 for sewer.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms
P/F Upvc nahani trap 110x110mm dia
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
P/F Upvc terminal guard 110 mm dia
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 45 cm length
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 110 mm bend
P/F Upvc door bend 110 mm dia.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 32 mm dia
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming toIS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 110x110x110 mm tee
P/F white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 225 mm
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 110 mm bend
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 110 mm Shoe
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 110x110x110 mm tee
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete (1:2:4).
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm dia
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): 20 mm dia
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): 25 mm dia
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): 32 mm dia
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 15 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 20 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 25 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 32 mm dia nominal bore
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
Providing and fixing PTMT grating of approved quality and colour. 100 mm nominal dia
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore
Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 25 mm nominal bore
Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 20 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore 15mm nominal bore
Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms
Excavation in Soil with Dozer with lead upto 100 metres (Excavation for road way in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 metres (average lead50 metres), including trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections.)(70 % Total Excavation)
Excavation in Ordinary Rock with Dozer with lead upto 100 metres (Excavation for roadway in ordinary rock by deploying a dozer, 80 HP including cutting and pushing the cut earth to site of embankment upto a distance of 100 metres ( average lead 50 metres ), trimming bottom and side slopes in accordance with the requirements of lines, grades and cross sections.) Ordinary rock (20 % Total Excavation)
Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal within all lifts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections. Mechanised Hard rock (10 % Total Excavation)
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 Earth filling
Concrete with cement, coarse sand and 40 mm gauge stone ballast in proportion 1:4:8 in foundations and floors including supply of all material, labour and T&P etc. required for proper completion of the work. as per drawings and technical specifications Clause 802, 803, 1202 & 1203
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203, Random rubble masonry In cement mortar (1:4)
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Hand Packed stone filling in back of wallls including cost of all materials, royality, T&P etc. complete as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications)
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Concrete with cement, coarse sand and 40 mm gauge stone ballast in proportion 1:4:8 in foundations and floors including supply of all material, labour and T&P etc. required for proper completion of the work. as per drawings and technical specifications Clause 802, 803, 1202 & 1203
Granular Sub-base with Well Graded Material By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. For Grading I Material
Cement Concrete (PCC M-30) Pavement:- Construction of Un-reinforced, Cement concrete pavement, thickness as per design, over a prepeared sub base with 43 grade cement or any other type PCC Grade M-30, coarse and fine aggregates conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less then 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (Steel channel, laying and fixing of wedges, steel plates including levelling the formwork and laying and fixing of 125 micron thick polythene film, as per drawing), spreading the concrete with shovels, rakes, compacted using needle, and plate vibrators, finished in continuous operation and curing of concrete slabs for 14 days, using curing compound where specified and water finishing to lines and grade as per drawings and technical specifications.
Providing and filling in position, blown bitumen in expansion joints.
Laying Cement Concrete Pipe NP3 (burried conduits) on first class bedding of granular material including fixing collar with cement sand mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonary work in head wall and parapets. 300 mm dia.
Providing and Laying of Interlocking Concrete Block Pavements of M-40 Grade having thickness 80 mm as per drawings and Technical Specification Clause 1504.
Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408) Using Concrete Mixer
Painting Two Coats on New Concrete Surfaces Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701
P/F in position pre cast RCC manhole cover and frame of required shape and of approved quality. Rectangular shape 600x450mm internal dimensions
Providing MS foot rest including fixing in manholes with 20x20x10cm cement concrete blocks 1:3:6 as per standard design. (i) with 20x20mm square bar
Providing MS foot rest including fixing in manholes with 20x20x10cm cement concrete blocks 1:3:6 as per standard design. (i) with 20x20mm square bar
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All types of soil 300 mm dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin- charge.
Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia,conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia.
Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts f required size complete. 150 mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I): 150 mm dia.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation oncrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing and filling sand of grading zone V or coarser grade, allround the CPVC pipes in external work : 20 mm diameter pipe
Providing and filling sand of grading zone V or coarser grade, allround the CPVC pipes in external work : 25 mm diameter pipe
Providing and filling sand of grading zone V or coarser grade, allround the CPVC pipes in external work : 32 mm diameter pipe
Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material rmeasurements and disposal of nserviceable material as directed, within a lead of 50 m :Ordinary rock : Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 150 mm dia. R.C.C. pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 150 mm dia. R.C.C. pipe
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame o f 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With Sewer bricks conforming to IS : 4885
Constructing brick masonry M.H. in C.M. 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with C.M. 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in C.C. 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90X80X45 cm i/c C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With Sewer bricks conforming to IS : 4885
Extra for depth for manholes : Size 90x80 cm- With Sewer bricks conforming to IS : 4885
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length. Sal wood
Installation / carving work on solid sal wood for traditional uttarakhand hilly area design
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Supply & Installation of Saint Gobain Roof shingles sheet, Hip & ridge over RCC slopi roof plastered surface, all complete as per direction of the Engineer in-charge.
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of Roof sheet or tiling with cement mortar (which will be paid for separately.
Stone work in plain ashlar in super structure upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : One face dressed : White sand stone
Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge.
Applying breathable, non-reactive, antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-Incharge (The rate is inclusive of all materials & labours involved except scaffolding).
Cleaning of exposed concrete, Brick, Stone surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge.
Supply & installation of 28 mm WPC Jali of size 7'x3' Complete with Scafolding & Fixing as per approved Design.
Wet Riser for fire fighting Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automaticoperation and consisting of following, complete in allrespects, as required (a) Horizontal type, multistage, centrifugal, split casingpump of cast iron body & bronze impeller with stainlesssteel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operationon 415 volts, 3 phase 50 Hz, AC supply with IP 55protection for enclosure, horizontal foot mounted typewith Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered 2280 LPM at 70 mtrs Head
Supplying, installation, testing and commissioning ofdiesel engine driven main fire pump suitable forautomatic operation and consisting of following,complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast ofiron body and bronze impeller with stainless steel shaft,mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thickaluminium sheet cladding, residential silencer,instruments and protection as per standard specification, stop solenoid for auto stop in the event offault with audio indications, painted with post office redcolour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plasteredand with anti vibration pads. 2280LPM at 70 mtrs Head
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 LPM at 56 mts head
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainlesssteel shaft, mechanical confirming to IS : 1520Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation,conforming to IS-325 .M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as requiredSuitable cement concrete foundation duly plastered and with anti vibration pads. 900 lpm at 35 m Head
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 150mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including,Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthatic enamel paint of required shade complete as required : 25 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including,Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthatic enamel paint of required shade complete as required : 32 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including,Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthatic enamel paint of required shade complete as required : 40 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including,Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthatic enamel paint of required shade complete as required : 50 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including,Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthatic enamel paint of required shade complete as required : 65 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including,Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthatic enamel paint of required shade complete as required : 80 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including,Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthatic enamel paint of required shade complete as required :100 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including,Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthatic enamel paint of required shade complete as required : 150mm dai
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including,Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthatic enamel paint of required shade complete as required : 200mm dai
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gasketsconforming to IS 13095 of following sizes as required : 40mm
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gasketsconforming to IS 13095 of following sizes as required : 50mm
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gasketsconforming to IS 13095 of following sizes as required : 65mm
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gasketsconforming to IS 13095 of following sizes as required : 80mm
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gasketsconforming to IS 13095 of following sizes as required : 100mm
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required 80mm
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required 100mm
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required 150mm dai
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required 200mm dia
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 200 mm
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 80mm
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 100mm
1Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 50mm dai
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.80mm 200mm
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required Stainless Steel (Grade 304)
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 mtrs
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required Stainless Steel (Grade 304)
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required 4 way-150 mm dia M.S. Pipe
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Pendent Sprinkler
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Upright Sprinkler
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Horizontal Side wall
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Concealed sprinkler
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 100mm
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/ sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasketetc of follwing sizes as required : 100 mm
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 700mm
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1000mm
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1200mm
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1500mm
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required
Design and construction of 200 KL (2 Part) capacity, RCC Under Ground Tank, Pump Room with suitable foundation Considering Seismic forces, including supply of all materials, labour, T&P etc. as required for proper completion of work. The earthquake resistant design must be in conformity with IS:456, IS:1893, IS:13932 & IS:13920 (latest versions). RCC work for water retaining portion should be not less than M-25 (design mix). The work will include submission of detailed design & drawings and Vetting before starting of the work, as per direction of client /employer.
Providing and fixing carbon-di-oxide fire extinguishers trolley mounted with all accessories internal discharge tube,high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:2878 Finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. Capacity 22.5 Kg.
Providing and fixing Carbon-di-oxide Fire Extinguishers consisting of welded M.S cylindrical body, squeeze lever discharge valve fitted with internal discharge tube. 30cms long high pressure discharge hose. Discharge nozzle,suspension bracket, confirming to IS:934 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge. (CCOE Nagpur Approved clynders) Capacity 4.5 Kg.
Providing and fixing of ABC type (Stored Pressure) Fire Extinguisher I.S.I marked & T.A.C.approved complete in all respect. 4 kg. capacity
Providing & fixing carbon steel Fire man axe with rubber insulated handle tested to 20000 volts.
Providing and fixing Mechanical foam ( AFFF) Fire Extinguisher I.S.I marked & T.A.C.approved complete in all respect. Capacity 9 Ltr.
Providing and Fixing of self illuminated /auto glow Exit signs printed on photoluminescent sheet containing self illuminated base chemical,of appropriate size not less than 400x150mm,suspended from ceilling or fixed to the walls with accessories as riquired and as directed at site.
Fixed clean agent gas based fire supression units 30 kg with 30 metrs Heat sensitive pipe Cease fire brand
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required 4 zone
Supplying, installation, testing & commissioning of response ndicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required
Supplying, installation, testing & commissioning ofceiling/wall mounted loud speaker, 3/1.5 Watt in ABSenclosure complete as required
Supplying, installation, testing & commissioning of digitalaudio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required.
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of intelligent aspiration detector for area coverage of minimum 5000 sq.ft. complete as required
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Supplying, installation, testing & commissioning of addressable phone control module complete as required.
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
Supplying, installation, testing & commissioning of fire fighter phone jack complete as required.
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zonebutton paging station) with seamless integration facility withmain fire alarm panel for voice evacuation complete as required.
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Supplying and drawing of cable Fire Retardant PVC insulatedcopper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required speaker cable Two pair, 2-core, 1.5 sqmm
Supplying and drawing of cable Fire Retardant PVC insulatedcopper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required speaker cable Four pair, 2-core, 1.5 sqmm
Auditorium Work ACOUSTICAL TREATMENT CEILING: Micro-perforated (3x3sqmm perforations) Gypsum board false ceiling for absorption: Providing & fixing perforated Gypsum false ceiling , as marked in the drawings, consisting of GI perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending GI intermediate channels of size 45mm (0.9mm thick with 2 flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angles of width 25mm x 10mm x 0.55mm thick fixed to soffit with GI cleats and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clips and in a direction perpendicular to the intermediate channel at 300mm c/c. Finished in 12.5mm thick micro-perforated gypsum board, 1200mm x 2400mm, with 3mm dia square perforations. The board shall have an overlay of 50mm thick, 1000 GSM polyester wadding, appropriately covered with FGT tissue (in the case of glasswool/ rockwool). The ceiling to be finished with 2 or more coats of mat type plastic emulsion paint after proper jointing & making surface smooth. Approved make of gypsum perforated board: Knauf Danoline/ Absound Overseas micro perforated/ Saint gobin -Quattro board.
Stage suspension Grid: Providing & fixing MS suspension grid system over stage for hanging stage services made of 2 nos 40x40x5mm MS angles welded back to back with 50x12x12mm thk studs as MS spacers sandwiched between the MS angles so as to maintain 12mm gap between MS angles, the welded angles to be placed @ 1200mm c/c in one direction and 40x5mm thick MS Tee @ 600mm c/c in other direction. The MS grid to be suspended from the roof structure by means of MS flat suspender of 50x6mm thick MS flats @ 1200mm c/c in both directions. All MS members to be painted with a coat of red oxide primer & 2 or more coats of black enamel paint.
Fibril acoustical tiles in stage ceiling: Providing and fixing Fibril black acoustical tiles of size 1200x600x25 mm, to be installed over existing MS suspension grid. Which will comprise of NRC 0.80. Approved make: Absound Overseas/Herra Design/Acoustic India.
ACOUSTICAL TREATMENT WALL PANELING: HDF based sound slats paneling for rear wall, side walls, proscenium & stage front (for LF absorption): Providing and fixing Wood melamine finish HDF based sound slat panels with lineal perforations on walls.The panels shall be with melamine laminate finish of size 2430mm x 128mm x17mm with 4mm slats at 28 mm pitch, Toungue and Groove edges for seamless mounting having density of 750 to 800kg/m3 . The back of the panels are perforated with 10mm diameter circular holes with a nonwoven fabric covering of 0.2mm for providing Sound absorption via the acoustic impedance method.Panel is to be fixed on GI framework as recommended by the manufacturer with screw fixed horizontal / vertical to wall at every 600mm c/c in tongue & groove system on GI studs 48x36x34mm framework. The cavity of framework should be inserted with 50mm thick, 1000 GSM polyester wadding appropriately covered with FGT tissue (in the case of glasswool/ rockwool).. Approved makes: Anutone/Absound Overseas/Acoustic India Inc
Acoustical paneling on rear & side walls (for HF absorption): Providing and fixing Acoustical Wall paneling with Compressed polyester fibre nonwoven 10mm thick panels with a density of 200kg/m3, of size1200mmX600mm with an NRC of 0.80 to 0.85 . The panels to be pasted with approved construction adhesives over 9mm thick perforated ply (minimum 20% perforations). The 9mm thick perforated ply shall be fixed over GI framing consisting of 48x36x34x0.5mm thick GI Studs wall channels & floor channels @ 600mm c/c with filling of 50mm thick 1000GSM thermally bonded polyester wadding. The insulation to be supported from the back by covering the frame with 19mm mesh GI wire netting. Approved Make : Acoustic India/ Absound Overseas/AMF.
Stage Walls treatment : Providing and fixing 20mm thick black fibril wood wool panels having density of 400kg/cum, fixed over a framework of GI channels consisting of 48x36x34mm GI Stud wall channels & floor channels @ 600mm c/c, filled with 50 mm thick 500GSM thermally bonded polyester wadding to be held in position with 19mm GI wire netting. Approved Make : Herra Design/ Acoustic India/ Absound Overseas.
Providing & fixing 100x15mm thick Polished teak wood skirting at the bottom of wall paneling. The skirting shall be fixed over 12mm thick commercial ply to match the level of paneling.
STAGE FLOORING Providing and fixing 90x20mm thick, in random length, Maple wood planks flooring with tongue & groove joints ,fixed to pine wood joist of size 72 x 48 mm at 230-300 mm c/c in one direction , pine wood joists to be resiliently supported on 75x50 mm rubber pads. The cavity of framing shall be filled with 50mm thick rock wool insulation of density 48kg/cum. Polishing of flooring on exposed surface: In horizontal/vertical plane (Rate for flooring shall include providing additional framework required for housing microphone and power outlet junction boxes.
Providing and fixing second class teak wood lipping/moulded beading or taj beading of size 50x50mm fixed with wooden adhesive of approved quality and screws/nail on external edges of stage .The work shall be executed as per drawings ,specifications & instructions of engineer in charge.
SOUND REDUCING DOORS Entry/exit doors for the auditorium 77mm thick, acoustic doors consisting of fire resistant materials & peripheral seals all around . The door to be laminated with 1mm thick laminate. The Door shutter frames to be of klin dried chemically treated second class teak wood. The door shutter frame to be lapped with 12mm thick BWR ply duly treated for fire retardance. Make : Global Fire/ Navair/ Absound Overseas.
Chowkhats for the doors in second class teak wood of size 125x 75mm duly fire treated.
Providing and fixing panic bars for the doors with double/single leaf with all necessary parts. Make: Geze/Dorma/Doorwin
Providing and fixing Hinges (Steel with bal bearings ) of size 125 X 32mm fixed with steel drive all screws of 35mm. Make: Doors, Ozone, Dorma
Providing and fixing external trim with locking arrangement & handle for panic bars double/single leaf with all necessary parts. Make: Geze/Dorma/Doorwin
Providing and fixing heavy duty door closers of load capacity of 100-120kg with all necessary parts. Make: Doors/Dorma/Godrej
Providing and fixing machine tuffed loop pile high low scroll nylon carpet effective pile height 6mm, total pile weight not less than 850 gm/sqm. secondary backing action back 55 gms/sqm. In rolls of 3.66 mtr. width as per size, shade, design and direction of Engineer-in-charge and as per manufacturer's specifications. The sample may be approved by the Engineer-in-charge before start of the work. The surface area will be measured for payment. The carpet to be bakced with 6mm thick PU underlay. Approved make: Absound Overseas, Birla Transasia, CCIL.
STAGE LIGHTING SYSTEM High quality 54x3W LED PAR Light used as a Effect Light, Spot Light and Strobe Light etc. with below specifications: • Lamp: 54 X 3W RGBW LED (12R+18G+18B+6W) • Max. Power consumpsion: 160W • Power supply: 100-230V AC, 50/60Hz • Power cable: 3 core 1.5 sq. mm. copper PVC insulated • Channels: 8 Channel DMX-512 • Beam angle: 25° • LUX @ 2m: 11,000 • Control mode: DMX,Manual and Master Slave • Dimming: 0 - 100% • Function: strobe, dimming, sound active and Master slave. • Housing: Diecast aluminium with black epoxy polyster powder coated • Power and DMX: Loop in and loop out • Dimension: W 220 x L 240 x H 335mm • Weight: 2.9 Kg • Certification: CE Make: Leksa, New Age
150W CE Certified LED Moving Head light with technical specifications as below: • Voltage : AC100V-240V, 50/60Hz • Lamp :150W LED • Channel :12 /16 channels • Pan scanning : 540° • Tilt scanning : 270° • Color Wheel 1 : color wheel (10 colors + open, rotating in directions and rainbow effect) • Color Wheel 2 :Rainbow color wheel including 6 colors • Gobo Wheel : 13 gobos (lncluding 4 glass gobos) + open • Prism: 8-facet prism with clockwise andanti-clockwise rotation • Dimmer: 0%-100% linear dimmer • Foggy: 0%-100% linear foggy • Touch screen with 180° reversed available and four press buttons • Dimentions : H: 425 x W 310 x D 295 mm • Gross Weight : 20KG • Certification: CE Make: Leksa, New Age
High quality 200W LED Profile Spot Light used as a Spot Light and high-contrast gobo projection Light. Other Technical specifications as below: • Lamp Power : 200W COB LED • Power Supply : AC 110-230V, 50Hz. • CRI : >90 • Colour Temperature : 3200K • Focus : Manual Focus • Beam Angle : 19° • Control : DMX, Autorun and Master/Slave • Shutter arrangements : Beam shapping shutter or plastic gobo projection assembly. • Lux Level - 20,375 lux @ 2 Mtr with beam angle 19°,3200K • Dimming : 0 - 100% dimming • Protection Rating : IP20 • Body Color : Black • Weight : 7.50Kg • Dimentions : W 300 x L 700 x H 310 mm. Make: Leksa, New Age
High quality LED 2x2 blinder matrix Light is used in Entertainment applications, Night club, Fashion shows, Film, Band performances, Discotheque, Stage performance , TV studio and large-scale show etc fixture with advanced COB LED technology with below specifications:- • Power Consumption: 400W • Power Supply: 100-240 AC, 50-60Hz • Light Color: Single color warm white (3200K) • LEDs Qty : 4 pieces • Channel: 4/8 channel • Lifetime: Over 50,000 hours • Beam Angle: 30 degree • Control mode: DMX512,Master/Slave, Auto Run, Sound active. • Dimmer: 0~100% linearly adjustable • LUX: 8270 LUX @ 2m • IP Grade: IP20 • Dimension: 117 x 350 x 382 mm • Net Weight: 7 kgs • Certification: CE Make: Leksa, New Age
High Quality 20x15W RGBWA 5 in 1 LED Wash Light fixture with below specification details. • Light Source : 20 x 15W RGBWA 5 in 1 LEDs • Operating Voltage : 100-240VAC, 50-60 Hz • Power: 300W Max • IP Rated IP20 /IP 65 • Beam angle : 45°/30° • DMX Channels : 5/9 • Operating Modes : DMX512 / Manual / Color Preset • Dimmer : 0-100% linear adjustment • Operating Modes DMX, Master/Slave, Color Preset • Housing Cast aluminum housing with natural cooling system • Power cable & DMX cable In-out looping cables • Dimension: 360 x 210 x 350 mm • Net Weight: 7.4 kgs Make: Leksa, New Age
Supply and fixing of LED Exit Light with battery back up. Make: Prolite, Bajaj
MS Pipe Class B dual barrel 40NB powder coated with Matt black finish, 2.2 mm wall thickness Pipe should have under gone 7 tanks chemical treatment process and rusto cleaned.
Fixed FOH light bar, length 18 Mtrs made using 40NB dual barrel with perforated Cable tray undergone through 7 tank process with various chemical treatment to keep them rust free, duly powder coated with Matt black texture finish and provided with suitable suspender and clamps.
Providing and fixing fabric wings on stage made of FR treated black cotton fabric stitched with pleats, fixed to ceiling frame with pivoted arrangement. Make: Nexgen/RSWM/Banswara Syntax
Main Valance fixing arrangement using 40NB Pipe 2mm thick, 23 mtr in length MS pipe, coated with matt black texture finish with mounting brackets to suspend the arrangement.
SUPPLY INSTALLATION TESTING AND COMMISSIONING of FRONT CURTAIN made out of FR Treated approved colour velvet cloth with horizontal sliding arrangement complete with fixing rails, brackets, sliding arrangements & motorised operation complete with runners, master runners, pullies, 3mm steel wire rope, 1HP motor (Crompton) 2nos. air breaker contactors (L&T/SIEMENS), 2 nos. micro switches for auto stop, 3nos. push buttons for forward, reverse and stop positions. The curtain should be draped to half area when in closed position. Minimum overlap at centre should be 900mm and should be stitched in double gathering. App size 21000x9000. Make of fabric: Banswara, Reliance, Raymonds, Nexgen.
Providing & fixing of the Border frills out of Fire retardant Crape black colour ( weight not less than 290 gms/sqm Make: Nexgen/RSWM/Banswara Syntax)) fabric in 1:2 gathers & acessories like cotton dori eyelets of brass complete hung from the ceiling suspension grid complete.
P/f of the cyclorama for the stage by fixing 35x35x5mm MS angle on the wall with MS angle hold fasts secured to the walls & 40mm dia 14G MS pipe welded to it as per the drgs. Further 40mm dia pipe welded to it at 600 centres vertically at an angle of 45 deg. & finally welding 40 mm dia pipe horzontally to it. The pipe to be supported away at 200mm centers by MS pipe.(MS framework payable separately) Further welding to it 12mm dia MS hooks welded both (top ,bottom & sides). The cyclorama frame to be supported by MS angle hold fasts of 35x35x5mm on the wall at 1200mm centers. Finally fixing PVC perforated screen, cyclorama cloth as per approved sample & fixing by cotton dori 10mm thick complete.
Installation hardwares such as clamps, connectors, glands, lugs, ferruels, welding rods etc.
MS perforated trays of size 40 mm X 75 mm X 40 mm, duly powder coated with matt black texture finish paint along with clamping arrangement.
MS perforated trays of size 40 mm X 150mm X 40 mm, duly powder coated with matt black texture finish paint along with clamping arrangement.
Grid mount photo isolator DMX Amplifier unit 1 DMX input and 8 isolated output with following specifications: • Power Supply: 90-240V AC, 45-63Hz. • Control: DMX 512 protocol, • Control Signal input: 5 pin XLR female, • Size: 482 x 44 x 128mm , • Weight: 2Kg.with splitter bracket. Make: Leksa, New Age
Digital Lighting Console with 1024 DMX channels • 1024 Channels. • 96 Fixtures. • 96 Dimmer Control Channels. • Time control of scenes: Fade in/out, LTP slope • Channels for each fixture 40 primary + 40 fine tune • LCD display with back light • 60 Scenes/Playbacks • 600 Scene step • 10 Scenes to run simultaneoulsy • Shape generato: Shapes of Dimmer, Pan/Tilt, RGB, CMY, Color, Gobo, Iris and Focus • Master slider - Global, playback, fixture • USB Memory - FAT32 supported Make: Leksa, New Age
M.S. Pipe Ladders to be provided on sides of the Stage to be fixed on the existing GI pipe or top grid. Made of 50mm x 25mm MS pipe complete as required size 1200x600. CUSTOM BUILT
PVC Copper unarmoured flexible FRLS insulated multicore cable 1100V grade confirming to IS694 size 3cx2.5 sq mm. Make: Polycab.
DMX signal cable for DMX network. Make: Dlink / Canara / Polycab.
16Amp sockets and swiches with MS boxes.
PVC conduits for wiring
Installation, testing and commissioning of Stage lighting & furnishing system including training to technical staff.
SOUND REINFORCEMENT AND VIDEO PROJECTION SYSTEM Supply Installation Testing and Commissioning of powered 15" Main Speakers (Left & Right) Frequency Range (-10dB): 50Hz-20kHz Power capacity: upto 1000W Maximum SPL: >120dB To include mounting accessories and connectors In case if OEM is giving Passive array speakers than supporting Class D amplfiiers to be added from Same OEM with indivudal speakers driven in Biamplified mode with minimum headroom 3dB. Make: EV/BOSE/ Music Group / Harman /Eqvt approved by Engineer in Charge
Subwoofer system: Supply Installation Testing and Commissioning of powered 18" subwoofer (Left and Right) Frequency Range(-10dB): 35Hz-200Hz Power: upto 1500W Maximum SPL: >110dB To include mounting frame, accessories and connectors In case if OEM is giving Passive array speakers than supporting Class D amplfiiers to be added from Same OEM with indivudal speakers driven in Biamplified mode with minimum headroom 3dB. Make: EV/BOSE/ Music Group / Harman /Eqvt approved by Engineer in Charge
FIILLERS: Supply Installation Testing and Commissioning of powered 12" Filler Speakers Frequency Range (-10dB): 50Hz-20kHz Power capacity: upto 1000W Maximum SPL: >120dB To include mounting accessories and connectors In case if OEM is giving Passive array speakers than supporting Class D amplfiiers to be added from Same OEM with indivudal speakers driven in Biamplified mode with minimum headroom 3dB. Make: EV/BOSE/ Music Group / Harman /Eqvt approved by Engineer in Charge
STAGE MONITORS: Supply Installation Testing and Commissioning of powered 8" Stage Monitors Frequency Range (-10dB): 50Hz-20kHz Power capacity: upto 1000W Maximum SPL: >100dB To include mounting accessories and connectors In case if OEM is giving Passive array speakers than supporting Class D amplfiiers to be added from Same OEM with indivudal speakers driven in Biamplified mode with minimum headroom of 3dB. Make: EV/BOSE/ Music Group / Harman /Eqvt approved by Engineer in Charge
GREEN ROOM, CONTROL ROOM and BALCONY SPEAKERS : Supply Installation Testing and Commissioning of powered two way 5"-6" Speaker pair Frequency Range (-10dB): 60Hz-20kHz Peak Power capacity>160W Maximum SPL: >110dB Mic/Line Input and Link output To include Wall mounting accessories and connectors Make: EV/BOSE/ Music Group / Harman Eqvt approved by Engineer in Charge
Supply of Control room headphones Wired around the ear headphones for monitoring Frequency Reposnse - 25Hz to 20KHz Make: AKG/Audiotechnica/Shure /Beyerdynamic or Eqvt approved by Engineer in Charge
MICOPHONES: Supply Installation Testing and Commissioning of Wired vocal microphone Cardoid or hypercardoid pattern dynamic microphone Make: AKG/Audiotechnica/Shure / Beyerdynamic or Eqvt approved by Engineer in Charge
Supply Installation Testing and Commissioning of Wired instrument microphone Cardoid or hypercardoid pattern dynamic microphone. Make: AKG/Audiotechnica/Shure/Beyerdynamic or Eqvt approved by Engineer in Charge
Supply Installation Testing and Commissioning of Wireless Handheld microphone To include 1 handheld microphones, 1 receiver with power supply, 1 charger for handheld transmitter, Antenna, cables etc. No. of simultaneous Frequencies per band should be minimum 12 per band Make: AKG/Audiotechnica/Shure /Beyerdynamic or Eqvt approved by Engineer in Charge
Supply Installation Testing and Commissioning of Lapel Microphone set To include 1 lapel microphones, 1 receiver with power supply, 1 body pack transmitter, 1 charger for body pack transmitter, Antenna, cables etc.No. of simultaneous Frequencies per band should be minimum 12 per band Make: AKG/Audiotechnica/Shure /Beyerdynamic or Eqvt approved by Engineer in Charge
Supply Installation Testing and Commissioning of 18" gooseneck cardoid/ hypercardoid pattern dynamic microphone To include mounts, connectors and cables Make: AKG/Audiotechnica/Shure /Beyerdynamic or Eqvt approved by Engineer in Charge
Supply Installation Testing and Commissioning of Active DI box To include mounts, connectors and cables Make: Klark technik/BSS or Eqvt approved by Engineer in Charge
Supply of microphone stand with boom - Floor standing Make: Custom/Eqvt approved by Engineer in Charge
Supply of microphone stand with boom - Table top Make: Custom/Eqvt approved by Engineer in Charge
CONTROL SYSTEM Supply Installation Testing and Commissioning of 24-Input 4/2-Bus Mixer with 10 Microphone Inputs, 4 stereo inputs,8 Compressors, EQs, Multi-FX Processor with LCD display, Wireless Option,built-in stereo USB/Audio Interface. Make: Music group, Harman, Yamaha
Supply Installation Testing and Commissioning of dual 31 band Graphic Equaliser Features: Auto gain control, delay control Make: Behringer/dbx/Eqvt approved by Engineer in Charge
Supply Installation Testing and Commissioning of Loudspeaker management system Inputs: 2, Outputs: 6 with RS232/RS485 control and Cascading feature Features: Auto gain control, delay control Make: EV/BOSE/QSC/ Music Group / Harman Eqvt approved by Engineer in Charge
Speaker cables 14AWG shielded twisted pair copper cable. Make: Belden/Sommer / Gotham /Eqvt approved by Engineer in Charge
Signal cables 20AWG shielded twisted pair copper cable Make: Belden/Sommer / Gotham /Eqvt approved by Engineer in Charge
Snake cables - 12 core 24AWG shielded twisted pair copper cable Make: Belden/Sommer / Gotham /Eqvt approved by Engineer in Charge
Microphone cables 24AWG shielded twisted pair copper cable Make: Belden/Sommer / Gotham /Eqvt approved by Engineer in Charge
Providing and fixing miscellaneous Connectors for audio/video system. Make: Neutrik/Amphenol/Switchcraft Eqvt approved by Engineer in Charge
Supplying and fixing 28U AV rack with power bar.
Supply installation testing & commissioning of lazer technology, minimum 7500 lumens projector with WUXGA resolution of 1920 x 1200 with contrast ratio of 2400:1 ; with standard lens only. Make: Digital Projection, Barco , NEC.
Supply Installation Testing and Commissioning of Motorised Projection Screen Remote operated Image Size:19'X12' Gain: >1 Make: Grandview/ Da-Lite/Draper Eqvt approved by Engineer in charge
Supply Installation Testing and Commissioning of LED 42" Display for Green rooms With 2 HDMI inputs Accessories:Including Remote control, Wall mount or ceiling mount and other accessories etc Make: LG/Panasonic/Sony/Eqvt approved by Engineer in charge
Supply Installation Testing and Commissioning of DVD/Bluray player Region compatibility: compatible with indian region Media supported: With 7.1 facility BD-rom, DVD-R/RW, DVD+R/RW,CD, USB memory, External Hard drive (FAT32/NTFS) Video and Audio formats: WMV, WMA, WAV, AVI, MP3, MP4, MPEG, AAC and other common formats Output Terminals: HDMI, 3.5mm mini audio jack To include cables and connectors Make: Sony, Philips or eqvt
Supply Installation Testing and Commissioning of HDMI Video Matrix Switcher 2 in 6 out Make: Extron/Kramer/Wyrestrom / Aton/Eqvt approved by Engineer in charge
Supply Installation Testing and Commissioning of VGA to HDMI converter Make: Extron/Eqvt approved by Engineer in charge
Supply Installation Testing and Commissioning of HDMI to VGA converter Make: Extron/Eqvt approved by Engineer in charge
Supply Installation Testing and Commissioning of Shielded CAT6 cables Make: Extron/Kramer/ Amp / Belden Eqvt approved by Engineer in charge
Supply Installation Testing and Commissioning of HDMI cables 20meters each Make: Extron/Kramer/Wyrestrom Eqvt approved by Engineer in charge
Supply Installation Testing and Commissioning of HDMI cables 10meters each Make: Extron/Kramer/Wyrestrom Eqvt approved by Engineer in charge
Supply Installation Testing and Commissioning of HDMI cables 5 meters each approved by Engineer in charge. Make: Extron/Kramer/Wyrestrom Eqvt
Supply Installation Testing and Commissioning of HDMI audio de-embedder Make: Extron/Kramer/Wyrestrom Eqvt approved by Engineer in charge
Supply Installation Testing and Commissioning of Floor boxes - 1 HDMI + Audio Make: Custom/Eqvt approved by Engineer in charge
Supply Installation Testing and Commissioning of Floor boxes - Audio With 2 microphones Make: Custom/Eqvt approved by Engineer in charge
Supply Installation Testing and Commissioning of Floor boxes for Power With 3 power points. Make: Custom/Eqvt approved by Engineer in charge
Audio & Video system programming and commisioning charges.
ELECTRICAL WORK Wiring for light point/ fan ponit/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed mediumclass PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Supplying and fixing of following ways surface/ recess mounting, Vartical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. 4Way (4+12), Double door
Supplying and fixing of following ways surface/ recess mounting, Vartical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. 8Way (4+24), Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6way 4+18 Double Door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral Single pole and neutral
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral Triple pole and neutral
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nutbolt & spring washer spaced at 50mm)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
P/F Hexagonal MS sheet fan box for ceiling fan clamp od internall dia 140mm, 73mm height top lid of 1.5mm thick MS sheet with its top surface hacked, MS clamp shall be made of 12mm dia MS bar bent to shape as per standard design.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 module
Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS PVC insulated, PVC sheathed copper conductor cable direct on the wall with PVC clips etc. as required.
Heigh Bay LED Light 100 W Ceiling mounting type Acentech AB_HB_100
36/40 W LED Batten tube Surya 40W6500K LED
300mm Bajaj propeller type ventlating fan with bird screen Freshee 300mm
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 3742019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
LED 12 W Recess mounting Down Lighter Phillips DN296B
36W 2x2 LED panel Crompton CGCEL Panel luminary
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supply,Installation, testing and commissioning of 400mm wall fan with fastners, connection etc. as required.
Supply,Installation, testing and commissioning of Air Circulator wall fan S Storm 2 Crompton make with fastners, connection etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Design, Fabrication, Supply, Erection,Testing and commisioning of Powder coated Main Distribution Panel fabricated out of 14 guage CRCA sheet steel in cubical, compartmentallised, FRLSee standing floor /wall mounted, dust and vermin proof, with reinforcement of suitable size angle iron, channel, T -iron or flats as required. Cable gland plates shall be provided on top as well as bottom of the panels. Panels shall be treated with all anti-corrosive process before painting as per specification. Panels shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with earth bus and lifting hooks as required in case of large panels.Approval shall be taken for each panel before fabrication. (All hardwares like nuts and bolts used shall be Galvanized and Zinc passivated with CT PTs , Multifunction Meter,required Operating Handels and Mech. Interlocking fot Bus coupler MCCB Building LT Panel as per specification with 2 nos of TP&N 1000 amps BUS Bar Sections one for Essential Panel and one for Non Essential INCOMER 800 A, FP, MCCB ,50 KA - 3 No One as Bus Coupler. OUTGOINGS Outgoing - 400 amp 50 KA FP MCCB -12 no.,Outgoing - 125 amp 36KA FP MCCB-2 nos 250 amps 36 KA FPMCCB 2 nos &Outgoing - 100 Amp 30KA FP MCB- 4nos.
Design, Fabrication, Supply, Erection,Testing and commisioning of Powder coated Main Distribution Panel fabricated out of 14 guage CRCA sheet steel in cubical, compartmentallised, FRLSee standing floor /wall mounted, dust and vermin proof, with reinforcement of suitable size angle iron, channel, T -iron or flats as required. Cable gland plates shall be provided on top as well as bottom of the panels. Panels shall be treated with all anti-corrosive process before painting as per specification. Panels shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with earth bus and lifting hooks as required in case of large panels.Approval shall be taken for each panel before fabrication. (All hardwares like nuts and bolts used shall be Galvanized and Zinc passivated with CT PTs , Multifunction Meter,required Operating Handels and Mech. Interlocking fot Bus coupler MCCB Building LT Panel as per specification with TP&N 300 amps BUS Bar INCOMER 400 A, TP, MCCB ,35 KA - 1 No. OUTGOINGS Outgoing - 200 amp 36 KA FP MCCB -1no.,Outgoing - 125 amp 36KA FP MCCB-1 &Outgoing - 100 Amp 30KA FP MCB- 3nos.
Providing Gyser (water Heater) 15 Liter Capacity. 5 Star Candes
S/F single pole blanking plate in the existing MCB DB complete etc. as required. (4 no. /MCBDB)
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. For AC
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate One Module for modular switches in recessincluding supplying and fixing Cat-6 Data Information Outlet, crimpling, connection, testing etc. as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 cable run
Supplying installation testing commissioning of 24 Port, Gigabit Data switch Dlink with 2 U rack , cable maneger etc as reqd.
10W LED Batten Wipro Garnet D631065 Polycarbonate 6500K
Supplying and fixing 8 way, Double Door single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supply of 18W Inverter LED pr batten with backup 8 hrs
Providing and fixing of 100 amps 30 KA Four pole rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required
10 W LED Bulkhead Kinjal 10WLED Plastic
Providing and fixing 200 amps 36 KA breaking capacity Four pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I.bolts, nuts, chuck nuts and spring washers etc. complete as required.
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
Transportation of Rig machine, camp equipage, connected T&P and necessary material, tubewell assembly pipe etc. required for drilling upto site of work including loading, unloading, erection and levelling of Rig machine in all respect.
Supply and fixing of suitable Casing shoe of EN-24 Steel for 200 mm dia casing pipe as per requirement of ODEX Attachment complete in all respect.
Drilling of 200 mm dia bore by rig machine in alluvial boulders, Pebbles, rocky stone, sticky clay etc by ODEX system including lowering, welding of casing/perforated pipe from ground level to 80 mts BGL
Drilling of 200 mm dia bore by rig machine in alluvial boulders, Pebbles, rocky stone, sticky clay etc by ODEX system including lowering, welding of casing/perforated pipe from 80 m to 150 mts BGL
Supply and lowering of M.S ERW (Fincut) 200 mm nominal dia casing pipe 6.0 mm thick duly properly beveled at 450 at both end [as per IS 3589/4270 ]( Plain pipe)
Supply and lowering of M.S ERW (Fincut) 200 mm nominal dia casing pipe 6.0 mm thick duly properly beveled at 450 at both end [as per IS 3589/4270 ] slotted / perforated pipe
Supply and lowering of M.S ERW (Fincut) 125 mm nominal dia casing pipe 5.4 mm thick duly properly beveled at 450 at both end [as per IS 3589/4270 ]( Plain pipe)
Supply and lowering of M.S ERW (Fincut) 125 mm nominal dia casing pipe 5.4 mm thick duly properly beveled at 450 at both end [as per IS 3589/4270 ] slotted / perforated pipe
Supply and fixing of suitable Casing shoe of EN-24 Steel for 200 mm dia casing pipe as per requirement of ODEX Attachment complete in all respect.
Development of tube well by air compressor, including erection,running of compressor and yield testing through "V" notch
Development of tube well by OP unit including providing of OP unit pump set, lowering & lifting of pump set, T&P at site running of O.P unit and yield test of TW at "V" notch
Chemical & bacteriological test of water
Hydrogeological survey of site
Supply of Submersible pump-set of 100 lpm cold and clear water against a total head of 150 m with suitable capacity motor to operate on 415±10% Volts, 3 Phase, 50 C/S A.C. Supply complete.(one no.as spare)
Supply of 4 Sq. mm PVC insulated 3- core submersible cable.
MCCB 63 Amp. with enclosure box with combinable polycorbonate insulated material suitable for shock proof, rust proof corrossion proof material and class-II safe IP 65.
Supply of jointing material such as lugs, tapes etc.
Double loop earthing of all electrical equipments including supply of G.I.earth strips (25mm X 5mm), G.I.earth Plates (600mm x 600mm x 6mm), G.I.Boxes,funnel,pipe etc as required as per latest I.E.Rules will be carried out by the contractor including digging of pits, filling of charcoal and salt in pitss complete in all respect (As per I.E.Rules)
Supply of Main Piping & Valves comprising of following:- 50 mm dia MS column pipe assembly having thickness 4.5 mm both ends threaded duly socketed etc. complete.
Supply of Main Piping & Valves comprising of following:- 50 mm dia C.I. D/F sluice valve with hand wheel PN-1.5
50 mm dia C.I. D/F Reflux valve PN-1.5
M.S.D.F. bend 90º × 50 mm dia - 2 Nos. 50 mm dia M.S.D.F. distance piece 2 mtrs. length - 1 No. 50 mm × 50 mm × 50 mm M.S.A.F.Tee - 1 No. 50 mm dia. MSDF distance piece 3.0 mtr. Long.- Ventury (50 x 32 mm) - 1 No.2 Nos.50 mm dia MS DI clamp heavy duty - 1 Set. M.S.T/W Cap (50 x 200 mm) - 1 No. Nuts, bolts, rubber / fiber packing for jointing above pipes & specials - 1 set.
Supply of following tools required for maintenance of pumping plants. Ring spanner set - 1 Set Screw drivers - 2 Nos. Pliers - 1 No. Hammeres - 1 No. Pipe wrench 14" - 1 No. Screw wrench - 1 No.
Supply of chain pulley block of 2 ton capacity 4.5 mtrs. lift complete with travelling trolley.
Supply of rubber resistance sheet of size 1 m × 2 m × 0.025 m.
Painting of entire installation with 2 coats of super enamel paint as per direction of Engineer-In-Charge of works.
Terminal equipment at consumer end including HT cables, CT PT , meter cubicle etc. 1 sets For independent feeder terminal equipment at sending end including swithch gear, ht cables, ct pt, meter cubicle etc 1 sets.Over Head 11 KV Line Cost Security Deposit for Rs. 1000/KW for 650KW
Supplying,installation,testing and commisioning of 650 Kva 11kV/0.433 kV outdoor Package type compact substation equipments comprising HT Panel, Transformers, HT cable, Bus trunking from Transformer to LT Panel, LT Panel, Automatic Power factor correction panel, Active Harmonic Filters,TVSS (Transient Voltage suppression system), SPD (Surge protection system), Essential panel,Earthing,required inter-connections, substation safety euipments including LT cabling from sub station to the buildings fed by the sub station. ( LT Paneel comprising of 1600 amps 4 pole ACB 1 no, 800 amps 50 KA FPMCCB 2 nos & 630 amps 50 KA FPMCCB- 1 no.)
S/F XLPE insulated screened PVC beded galvanized steel strip of wire armoured electric power cable (heavy duty) with aluminium conductor 11KV greds cross sectional area 300 sqmm as per diected by engineer-in-charge. For metering eqpt.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe FRLSom earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Supplying and making end temination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium couductor cable of 1.1 KV grade as required. 2x6
Supplying and making end temination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium couductor cable of 1.1 KV grade as required. 4x16
Supplying and making end temination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium couductor cable of 1.1 KV grade as required. 3.5x35
Supplying and making end temination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium couductor cable of 1.1 KV grade as required. 3.5x70
Supplying and making end temination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium couductor cable of 1.1 KV grade as required. 3.5x95
Supplying and making end temination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium couductor cable of 1.1 KV grade as required. 3.5x120
Supplying and making end temination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium couductor cable of 1.1 KV grade as required. 3.5x185
Supplying and making end temination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium couductor cable of 1.1 KV grade as required. 3.5 x 240 sq. mm
S/M OUTDOOR cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: upto 300 sq. mm
supplying and making indoor cable end termination with heatshrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core,300 sq.mm, XLPE aluminiumconductor cable of 11 KV grade as required :
S/E of three piece nonlinear resistor type lighting arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharege current rating of 5 KV and complete with galvanised clamping arrangenment, G.I. bolts, nuts, washers etc. as required.
6 meter GI octegonal pole single arm with loop in box Bajaj
Erection of Octagonal street light pole of 6 to 8 meter length in RCC 1:2:4 foundation including excavation, refilling, Reinforcement etc. as per Pole Manufacture design.
Supplying and fixing 60W LED streetlight made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP66 protection complete with all accessaries.
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade aluminium conductor armored of following size in the existing RCC/ HUME/ METAL pipe as required. 2x6 sq.mm
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade aluminium conductor armored of following size in the existing RCC/ HUME/ METAL pipe as required. 2x16 sq.mm
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade aluminium conductor armored of following size in the existing RCC/ HUME/ METAL pipe as required. 4X16 Sq.mm.
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade aluminium conductor armored of following size in the existing RCC/ HUME/ METAL pipe as required. 3.5x35 Sqmm
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade aluminium conductor armored of following size in the existing RCC/ HUME/ METAL pipe as required. 3.5x70 Sqmm
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade aluminium conductor armored of following size in the existing RCC/ HUME/ METAL pipe as required. 3.5x95 Sq.mm
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade aluminium conductor armored of following size in the existing RCC/ HUME/ METAL pipe as required. 3.5x120 sq.mm
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade aluminium conductor armored of following size in the existing RCC/ HUME/ METAL pipe as required. 3.5x 185 Sq.mm
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade aluminium conductor armored of following size in the existing RCC/ HUME/ METAL pipe as required. 3.5x240 Sqmm
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade aluminium conductor armored of following size in the existing RCC/ HUME/ METAL pipe as required. 3.5x300 sq.mm
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 80mm (Civil DSR)
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 110mm
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 150mm
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required 300mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 160mm
Supply, Installation, testing and commissioning of Salient Type DG set, AMF Panel, bus ducting/ cables from DG set to Essential Panel, Synchronising Panel if reqd., DG set Enclosure room sound insulation, ventilation, smoke exhaust, Earthing of DG set System, control cabling, fuel Tank piping,exhaust chimney and piping,as per CPCB norms, civil works connected with DG sets, including foundation etc. as reqd.
Supply ,installation testing and commissioning of MiniSpace 13 Pessenger (884Kg) lift having contract speed of 1.5 m/s serving for different floors (B+G+5) 7 floors, Type(MRL) Machine room less with gearless traction having + /- 5% landing accuracy, speed 1.5 mps, 7 levels with a total travell of 25.2 mtrs,(approx.) with 7 stops and all opening all on one side, with VAVF cotroller,having ARD with Dry MF batterirs, Microprocessor based simples slective collective with attendent operations,415 V 50 Hz 3 phase 4 wire power, with power operated centre opening horizontal sliding stainless steel scrach free car and landing doors, infra red curtain and one hour fire rating, with overload waring indiactor, concealed luminary with LED light, axial pressure ceiling fan, . with voice annoucement system. etc as required.
Supplying, installation, testing and commissioning of online 3 phase UPS System with 30 minutes back up including batteries, interconnecting cables, battery racks etc 50 KVA
Supply installation ,testing & commissioning of Lighting Automation including Occupancy Sensors
Supplying, installation, testing and commissioning of IP based EPABX System comprising of Core switches & L2 switches with 10 G, 10 Giga SFP modules, Industry Standard Appliance Server, Cloudbased, enterprise-grade UC Solution, MID/ENTRY Level IP/SIP Phone with, Dual 1 Gig Ports, Racks, CAT 6A cable, Patch Panels, OFC etc
Supply,Installation,Testing&Commissioning of modular type City Multi Heat Pump Mitsubishi VariableRefrigerantFlow/ Variable Refrigerant Volume System Outdoor units suitableforcooling andheating,having all hermetically sealed invertertype Scroll Compressor(s), minimum two compressors for above14HPmodules, microprocessor based Controller, top discharge type condensing unit(s) ,withR410A Refrigerant, vibration isolators, withsuitable foundationetc. complete asrequired. Theunitshalldeliver the rated capacity at AHR IConditionsandworkevenat 50°C ambienttemperature without tripping. The unit shall be suitable to workon 400V+/-10%, 3Phase, 50Hz AC powersupply.Theunit shall be filled with first charge of the refrigerant and ready for use as required.The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 .
Supply,installation,testingandcommissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/ dynamicallybalancedblower, multispeedmotor, coilsection with DX Coppercoil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports,vibrationisolation, cordless remote control etc., suitable for operation on singlephase230V±10%,50Hz AC supply, complete,asrequired. The unit shall have automatic force shutdown provision in caseof fire on receiving signal fromBMSSystem. The cooling capacity of indoorunit will be at air inlet conditionsof27DegreeCDBand19Degree CWB temperature. 1 TR
Supply,installation,testingandcommissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/ dynamicallybalancedblower, multispeedmotor, coilsection with DX Coppercoil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports,vibrationisolation, cordless remote control etc., suitable for operation on singlephase230V±10%,50Hz AC supply, complete,asrequired. The unit shall have automatic force shutdown provision in caseof fire on receiving signal fromBMSSystem. The cooling capacity of indoorunit will be at air inlet conditionsof27DegreeCDBand19Degree CWB temperature. 1.6 TR
Supply,installation,testingandcommissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/ dynamicallybalancedblower, multispeedmotor, coilsection with DX Coppercoil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports,vibrationisolation, cordless remote control etc., suitable for operation on singlephase230V±10%,50Hz AC supply, complete,asrequired. The unit shall have automatic force shutdown provision in caseof fire on receiving signal fromBMSSystem. The cooling capacity of indoorunit will be at air inlet conditionsof27DegreeCDBand19Degree CWB temperature. 4 TR
Supply,installation,testingandcommissioning of following minimum capacity 4-way flow VRV/VRF High wall Type Indoor unit equipped with synthetic washable media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeedmotor, coilsection with DX Coppercoil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports,vibrationisolation, cordless remote control etc., suitable for operation on singlephase230V±10%,50Hz AC supply, complete,asrequired. The unit shall have automatic force shutdown provision in caseof fire on receiving signal fromBMSSystem. The cooling capacity of indoorunit will be at air inlet conditionsof27DegreeCDBand19Degree CWB temperature. 1 TR
Supply,installation,testingandcommissioning of following minimum capacity 4-way flow VRV/VRF High wall Type Indoor unit equipped with synthetic washable media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeedmotor, coilsection with DX Coppercoil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports,vibrationisolation, cordless remote control etc., suitable for operation on singlephase230V±10%,50Hz AC supply, complete,asrequired. The unit shall have automatic force shutdown provision in caseof fire on receiving signal fromBMSSystem. The cooling capacity of indoorunit will be at air inlet conditionsof27DegreeCDBand19Degree CWB temperature. 1.45 TR
Supply,installation,testingandcommissioning of following minimum capacity 4-way flow VRV/VRF High wall Type Indoor unit equipped with synthetic washable media pre-filter, fan section with low noise fan/ dynamically balanced blower, multispeedmotor, coilsection with DX Coppercoil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports,vibrationisolation, cordless remote control etc., suitable for operation on singlephase230V±10%,50Hz AC supply, complete,asrequired. The unit shall have automatic force shutdown provision in caseof fire on receiving signal fromBMSSystem. The cooling capacity of indoorunit will be at air inlet conditionsof27DegreeCDBand19Degree CWB temperature. 2 TR
Supply,Installation,testing and commissioning including vaccumiazationandNitrogentesting of following nominalsizes of soft/hard drawn copper refrigerant piping for VRV/VRFsystem, complete with fittings, with suitablea djustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/withClass-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquidlines,allaccessories as per specifications etc. as required : 6.4mmdia(OD)(Softdrawn)with tube thickness 1.2mm with19mmthick insulation
Supply,Installation,testing and commissioning including vaccumiazationandNitrogentesting of following nominalsizes of soft/hard drawn copper refrigerant piping for VRV/VRFsystem, complete with fittings, with suitablea djustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/withClass-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquidlines,allaccessories as per specifications etc. as required : 9.5mmdia(OD)(Softdrawn)with tube thickness 1.2mm with19mmthick insulation
Supply,Installation,testing and commissioning including vaccumiazationandNitrogentesting of following nominalsizes of soft/hard drawn copper refrigerant piping for VRV/VRFsystem, complete with fittings, with suitablea djustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/withClass-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquidlines,allaccessories as per specifications etc. as required : 12.7mmdia(OD)(Softdrawn)with tube thickness 1.2mm with19mmthick insulation
Supply,Installation,testing and commissioning including vaccumiazationandNitrogentesting of following nominalsizes of soft/hard drawn copper refrigerant piping for VRV/VRFsystem, complete with fittings, with suitablea djustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/withClass-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquidlines,allaccessories as per specifications etc. as required : 15.86 mmdia(OD)(Softdrawn)with tube thickness 1.2mm with19mmthick insulation
Supply,Installation,testing and commissioning including vaccumiazationandNitrogentesting of following nominalsizes of soft/hard drawn copper refrigerant piping for VRV/VRFsystem, complete with fittings, with suitablea djustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/withClass-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquidlines,allaccessories as per specifications etc. as required : 19mmdia(OD)(Hard drawn)with tube thickness 1.2mm with19mmthick insulation
Supply,Installation,testing and commissioning including vaccumiazationandNitrogentesting of following nominalsizes of soft/hard drawn copper refrigerant piping for VRV/VRFsystem, complete with fittings, with suitablea djustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/withClass-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquidlines,allaccessories as per specifications etc. as required : 31.8mmdia(OD)(Harddrawn)withtubethickness1.62mmwith19mm thick insulation
Supply,Installation,testing and commissioning including vaccumiazationandNitrogentesting of following nominalsizes of soft/hard drawn copper refrigerant piping for VRV/VRFsystem, complete with fittings, with suitablea djustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/withClass-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquidlines,allaccessories as per specifications etc. as required : 38.1mmdia(OD)(Harddrawn)withtubethickness1.62mmwith19mm thick insulation
Supply,Installation,testing and commissioning including vaccumiazationandNitrogentesting of following nominalsizes of soft/hard drawn copper refrigerant piping for VRV/VRFsystem, complete with fittings, with suitablea djustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/withClass-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquidlines,allaccessories as per specifications etc. as required : 41.27mmdia(OD)(Harddrawn)withtubethickness1.62mmwith19mm thick insulation
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. Remark Solar inverter has 6 yr warranty, Solar panel have 10 yr warranty, AMC is required after 6 yr, 1 Array will have 10 panel connected in series, Connection 1 array have 10 panels in series 240 volts DC, 10 amp, Connection 10 array output in parallel 240 volts 100 amp DC, Connection output 2 parallel array in series 480 volts 100 amp.
SITC of Solar Pathway light with panel , Battry and 20 w LED light
Supply installation testing and commissioning of Carrier 1.5 Ton 3 Star High wall Split AC (Hot and Cold) CarrierR (Carrier & Superia 365) including initial charging etc. as reqqd.
Supply installation testing and commissioning ofHitachi 2 Ton 3 Star High wall Split AC (Hot and Cold)HitachiR (MODEL NO- RMOG324HDXA) Carrier including initial charging etc. as reqqd.
Supply installation testing and commissioning of Voltas 3 Ton 5 Star Ceiling Mounted Split AC (Cassette AC - Hot and Cold)VoltasR (VOLTAS ICAS 36VH)including initial charging etc. as reqqd.
Supplying and installing 4 MP IP CCTV Bullet camera,CP Plus.
Supplying and installing 4 MP IP CCTV Dome camera,CP Plus.
POE Acess Switch 24 Port
D-Link 6U Rack Enclosures Networking/Server Rack with cable management and Connectors etc. as reqd. D-LinkR (NWR-6U-5045-GR)
64 Input and 4 Output Channel Video Recorder For Cctv SystemSparshR (SR-NP3232F5H-H(E)(D)(P))
Sony 82 cms LCD Panel monitor.
FES 8 Ports Managed PoE+ Layer 2 Access Switch FESR (FES-GS-1010P)
HT HDMI1.4 Cat.6 10.2 Hdmi Extender IHTR (IHT-HDMI-E60NTS (60Mtrs))
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 cable run
LISHA ENGINEERS PRIVATE LIMITED (BID ID -380020)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ.xls
BOQ • 0.77 MB
Tenderdocument.pdf
Tender Documents • 2.59 MB
Download all tender documents and submit your bid