Name of Work: Rate Contract of Miscellaneous Electrical Installation/Repairing Work at
East and West side of Riverfront Premises of Sabarmati Riverfront Development
Corporation Ltd. (Limit Up to Rs.30 Lacs).
Item No Description Unit Rate without GST
PART A SITC Items
Point wiring for Light / Fan/ Bell/ Primary Point with 2-
1.5 sq. mm & earth wire of 1.5 sq. mm (green) both
are of ISI marked 1.1 kv grade FRLS PVC
insulated multi strand copper wires upto max length of
10 mt, in below type of pipe erected with 6A Tissino
1 Type ISI marked flush type switch / bell push and
accessories erected on Metal / PVC/ Wooden Box
covered with 3 mm thick PC(Polycarbonate) /Acrylic/
Laminated sheet. with necessary Lamp holder/ceiling
rose /H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling Pt
(c) with oval conduit / PVC casing capping double
lock type erected flushed on wall/ceiling complete Pt.
(e) in existing pipe erected flushed on
wall/ceiling complete Pt
(j) in existing pipe erected concealed in wall/ceiling
Point wiring for independent PLUG with
following size mains earth wire of 1.5 sq.mm
(green) both are of ISI marked 1.1 KV grade
FRLS PVC insulated multi strand copper wires upto
10 mt length, in following below of pipe erected
2 complete with ISI marked 3 / 5 Pin socket and
tissino type switch erected with earth continuity
connection erected on Metal / PVC/ Wooden box
covered with 3 mm thick PC (Polycarbonate) /
Acrylic / Laminated sheet.
[A] For 6 amp plug and 6 amp switch with 2-
(A) sq. mm Cu. Mains from near by
switchboard/db board upto 6 mt.
(a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling Pt.
(c) with oval conduit /PVC casing capping double
lock type erected flushed on wall/ceiling complete Pt.
(e) in existing pipe erected flushed on
wall/ceiling complete Pt.
(j) in existing pipe erected concealed in wall/ceiling
[B] 6/16A Plug and 16 amp switch with 2-2.5 sq.
mm Cu. Mains from mcb db boards.
(a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling Pt.
(c) with oval conduit /PVC casing capping
double lock type erected flushed on wall/ceiling Pt.
(e) in existing pipe erected flushed on
wall/ceiling complete Pt.
(j) in existing pipe erected concealed in wall/ceiling
[C] 6/16A Plug and 16 A switch with 2-4 sq.mm Cu.
Mains with 2.5 sq.mm (green) earthing wire
(a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling Pt.
(c) with oval conduit /PVC casing capping double lock
type erected flushed on wall / ceiling complete Pt.
(e) in existing pipe erected flushed on
wall/ceiling complete
(j) in existing pipe erected concealed in wall/ceiling
Point wiring for on board looped PLUG with
tissino type single pole ISI marked Switch and Socket
3 erected with necessary connections erected on
wooden /Metal/ PVC Box covered with 3 mm thick
PC(Polycarbonate) /Acrylic sheet for open /
[A] wiring for following size.
[B] For 16 Amp. Pt.
Point wiring for secondary light point with 2-1.5
sq.mm & earth wire of 1.5 sq.mm (green) both are of
ISI marked 1.1 KV grade FRLS PVC insulated multi
strand copper wires, in below type of pipe to be
erected complete with earth continuity and necessary
connection with primary light with accessories erected
4 on Metal / PVC / wooden box covered with 3 mm
thick PC (Polycarbonate) / Acrylic sheet for open /
concealed wiring. with necessary Lamp holder /
ceiling rose / H.D. Connector as directed.
Note:- Maximum up to 6 mtrs length, excess will
be considered as Mains for Secondary Point.
(a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling Pt.
(c) with oval conduit /PVC casing capping
double lock type erected flushed on wall/ceiling Pt.
(e) in existing pipe erected flushed on
wall/ceiling complete Pt.
(j) in existing pipe erected erected concealed in
wall/ceiling complete Pt.
Point wiring for Two Way Controlled Light Point with
2-1.5 sq.mm & earth wire of 1.5 sq.mm (green)
both are of ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires up to 10 mtr
length, in following type of pipe to be erected
concealed in / flushed on wall / ceiling complete with
6A Tissino Type ISI marked accessories with earth
continuity erected on Metal / PVC / Wooden box
covered with 3 mm thick PC(Polycarbonate) /
Acrylic sheet with necessary Lamp holder/ceiling rose
/ H.D. Connector as directed.
(a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling Pt.
(c) with oval conduit /PVC casing capping
double lock type erected flushed on wall/ceiling Pt.
(e) in existing pipe erected flushed on
wall/ceiling complete Pt.
(j) in existing pipe erected erected concealed in
wall/ceiling complete Pt.
Point wiring for Light /Bell with 2-1.5 sq.mm & earth
wire of 1.5 sq.mm (Green) both are of ISI marked
KV grade FRLS PVC insulated multi strand copper
wires up to 10 mtr length , in below type of pipe
erected with 6A Modular type switch / bell push &
accessories and earth continuity of following type,
6 erected on PVC / Metallic/ Wooden box, single
mounting base frame covered with textured/
metallic /white front plate modules erected on / in
wall / ceiling as per pipe erected, with necessary
Lamp holder/ceiling rose / H.D.Connector as
(a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling
(c) with oval conduit /PVC casing capping
double lock type erected flushed on wall/ceiling
(e) in existing pipe erected flushed on
wall/ceiling complete
(j) in existing pipe erected concealed in
wall/ceiling complete
Point wiring for FAN with 2-1.5 sq.mm & earth wire
of 1.5 sq.mm (Green) both are of .ISI marked
KV Grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length, in below type of
pipe erected with 6A Modular type switch and hum
free EME step type electronic fan regulator mounted
and accessories with earth continuity of following type
7 erected on PVC / Metallic / Wooden box, single
mounting base frame covered with textured /metallic /
white front plate modules erected on / in wall / ceiling
as per pipe erected with necessary ceiling rose /
H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling
(c) with oval conduit /PVC casing capping
double lock type erected flushed on wall/ceiling
(e) in existing pipe erected flushed on
wall/ceiling complete
(j) in existing pipe erected concealed in
wall/ceiling complete
Point wiring for Individual Plug with & earth wire
of 1.5 sq.mm (Green) both are of ISI marked
KV grade FRLS PVC insulated multi strand copper
wires up to 10 mtr length, in below type of pipe
erected complete with Modular type switch &
8 pin Plug erected on PVC / Metallic / Wooden box
covered with appropriate front plate modules erected
on / in wall / ceiling as per pipe erected with following
type of accessories.
[I] For 6A Plug and 6 A switch with 2-1.5 sq.mm
(I) Cu. Wire from nearby switchboard/mcb db board
(a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling
(c) with oval conduit /PVC casing capping
double lock type erected flushed on wall/ceiling
(e) in existing pipe erected flushed on
wall/ceiling complete
(j) in existing pipe erected concealed in
wall/ceiling complete
[II] For 16A Plug and 16 amp switch with 2-2.5
sq.mm Cu. Wire from mcb db board.
(a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling
(c) with oval conduit /PVC casing capping
double lock type erected flushed on wall/ceiling
(e) in existing pipe erected flushed on
wall/ceiling complete
(j) in existing pipe erected concealed in
wall/ceiling complete
[III] For 16A Plug and 16 amp switch with 2-4 sq.mm
(III) Cu. Wire with 2.5 sq.mm (green) earthing wire
from mcb d b board.
(a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling
(c) with oval conduit /PVC casing capping
double lock type erected flushed on wall/ceiling
(e) in existing pipe erected flushed on
wall/ceiling complete
(j) in existing pipe erected concealed in
wall/ceiling complete
Point wiring for on board Looped Plug with 6A
Modular type switch & 5 pin socket erected on PVC /
Metallic/Wooden box, single mounting base
9 frame covered with textured/ metallic/ white
front plate modules erected on / in wall / ceiling with
following type accessories
Providing following type of Modular Type
Accessories mounted with PVC /metallic/Wooden
box, single mounting base frame covered with
10 textured / metallic/white front plate, modules
erected with necessary connections as per site
situation directed by Engineer In charge.
(1)One No. SP 6 Amp.
(2) One No 5 pin plug
(4) TV Co-axial Socket outlet
(5) Electronic hum Free steps EME Fan
(6) Fuse units 10Amp. or 16 Amp.
(7) Blank Plate Single
(8) Computer RJ-45 socket
(9) 16 Amp. SP one way switch
(10) 6/16Amp. Universal socket
(11) 6 Amps. Bell Push
(12) 6Amp. / 16 Amp. Two Way switch
(13) 6A/10A/16A/20A/25A/32A Single pole Modular
(14) 6A/ 10A/ 16A/ 20A/ 25A/ 32A Double Pole
Modular MCB Switch
(15) 32 Amps. DP switch with Indicator
(16)32 amp DP main switch Oparating with energy
(18) 13 Amp. International Modular Socket
(19) Modular Indicating Call Bell
(22)16/20/25 Amp. Modular Starter for Motor / A.C.
(24) Batten Holder/Angle Holder with modular
frame with metal ring. Ea
Providing & erecting following type of Modular Type
11 Accessories with necessary connection. As desired
by Engineer In charge
(1) 6 Amp. SP one way switch Ea
(2) 16 Amp. SP one way switch Ea
(3) 6/16Amp. Universal socket Ea
(4) 6 A socket Ea
(5) LAN cable connector with ferule Ea
Providing and erecting ISI mark Medium class RIGID
PVC PIPES of following size complete to be
erected on/in wall or ceiling erected with necessary
PVC fittings & Junction boxes fixed with adhesive
solution & Clamps with following dia of pipes, in
approved manner as directed
Providing & erecting PVC Corrugated Flexible
Conduit with required nos. of coupling, PVC
bushes, Check-nuts etc. complete of following sizes.
Supplying & erecting UPVC Mini trunking (PVC
Casing-n-Capping) having double-locking
arrangement with grooves, trunking of size not below
12.5 mm in height as per IS with accessories
of PVC/Resin polypropylene not below 1.8 mm
thick duly sealed in joint & erected on wall / ceiling
of following size .
Providing and erecting Mains with 1.1 KV
grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of
15 pipe to be erected concealed in /flushed on
wall/ceiling, with 1.5 sq. mm copper conductor FRLS
PVC insulated stranded wire of green colour for
earth continuity of following size
(A) With medium class Rigid PVC pipe and
(a) 2 wire 1.5 sq. mm Mtr.
(b) 2 wire 2.5 sq. mm Mtr.
(c) 3 wire 1.5 sq. mm Mtr.
(d) 3 wire 2.5 sq. mm Mtr.
(e) 4 wire 1.5 sq. mm Mtr.
(f) 4 wire 2.5 sq. mm Mtr.
(C) With oval conduit / PVC casing capping
double lock type
(a) 2 wire 1.5 sq. mm Mtr.
(b) 2 wire 2.5 sq. mm Mtr.
(c) 3 wire 1.5 sq. mm Mtr.
(d) 3 wire 2.5 sq. mm Mtr.
(e) 4 wire 1.5 sq. mm Mtr.
(f) 4 wire 2.5 sq. mm Mtr.
(E) (E) in existing pipe
(a) 2 wire 1.5 sq. mm Mtr.
(b) 2 wire 2.5 sq. mm Mtr.
(c) 3 wire 1.5 sq. mm Mtr.
(d) 3 wire 2.5 sq. mm Mtr.
(e) 4 wire 1.5 sq. mm Mtr.
(f) 4 wire 2.5 sq. mm Mtr.
providing and erecting Mains with 1.1 KV
grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type
16 of pipe to be erected in / on wall / ceiling with 2.5 sq.
mm copper conductor FRLS PVC insulated stranded
wire of green colour for earth continuity of following
(A) with medium class Rigid PVC pipe and
(a) 2 wire 4 sq. mm Mtr.
(b) 2 wire 6 sq. mm Mtr.
(C) with oval conduit / PVC casing capping
double lock type
(a) 2 wire 4 sq. mm Mtr.
(b) 2 wire 6 sq. mm Mtr.
(E) (E) in existing pipe
(a) 2 wire 4 sq. mm Mtr.
(b) 2 wire 6 sq. mm Mtr.
providing and erecting Mains with ISI marked, 1.5KV
grade electrolyte multi stranded, annealed copper
conductor with heat resistant PVC insulated
conforms to IS 694, IEC - 227 erected in existing
17 pipe of following size (Specifically for control panel,
relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and
bolts if required.
(f) One wire 10.00 sq. mm Mtr.
(g) One wire 16.00 sq. mm Mtr.
(h) One wire 25.00 sq. mm Mtr.
(i) One wire 35.00 sq. mm Mtr.
(j) One wire 50.00 sq. mm Mtr.
(k) One wire 70.00 sq. mm Mtr.
(l) One wire 95.00 sq. mm Mtr.
(m) One wire 120.00 sq. mm Mtr.
(n) One wire 150.00 sq. mm Mtr.
Providing & Erecting approved make following size of
TV Co-axial flexible cable comprising inner
conductor of solid bare copper insulated with Foam
18 PE & Secondary conductor made of poly -
Aluminium film bonded Al. Braids @ suitable
coverage overall sheathed with black PVC
(c) RG - 6 CCS Mtr.
(d) RG - 11 CCS Mtr
Supplying & erecting approved make Telephone
Cable electrolytic copper conductor PE insulation
twisted in two pairs & wrapped with FRLS PVC tape
& sheathed with FRLS PVC or HFFR outer Jacket
20 suitable for telephone wiring & confirming to C-DOT
erected in existing pipe of following size of
conductors & nos.of pairs. With necessary
[A] Conductor Size 0.5 mm
(1) One Pair Mtr.
(2) Two Pairs Mtr.
(3) Three Pairs Mtr.
(4) Five Pairs Mtr.
(5) Ten Pairs Mtr.
(6) Twenty Pairs Mtr.
(b) Armoured [Jelly Filled]
(1) Ten Pairs Mtr.
(2) Twenty Pairs Mtr.
(3) Fifty Pairs Mtr.
(4) One Hundred Pairs Mtr.
Supplying & erecting approved make LAN
19 cable of following size in existing pipe as per
[C] CAT - 6 Mtr
[D] CAT - 6 e Mtr
Providing & erecting main Distribution (MDF)
20 indoor type, back mounted frame as per DoT
standard approved with krone strips
(a) Suitable for 10 pair Ea.
(b) Suitable for 20 pair Ea.
(c) Suitable for 50 pair Ea.
(d) Suitable for 100 pair Ea.
(e) Suitable for 200 pair Ea.
Providing & Erecting 6 core fibre optic SM
21 9/125um double sheath, CSTA, Unitube, Rmtr.
Outdoor cable (per m)
Providing & Erecting following Shock proof tissino
type accessories erected on 3 mm thick PC
(Polycarbonate) sheet in PVC/ Metal/Wooden Box.
erected on wall/ ceiling.
(2) One no 3/5 pin 6 A Socket Ea.
(3) One no Single pole 16 A Switch Ea.
(4) One no 6/16 A Universal Socket Ea.
(10) Jack type tissino Telephone outlet Ea.
(11) Tissino type Neon ‘Indicator Lamp’ Ea.
(12) Tissino type TV antenna socket Ea.
(13) Tissino type 10A/16A Kitkat fuse Ea.
(14) Electronic Hum free EME Socket Type Steps Ea.
Providing & erecting Switch board for Computer or
electric apparatus consisting of following items in
single board erected on PVC / Metal / Wooden board
concealed / open with 3 mm thick PC
23 (Polycarbonate) / Acrylic sheet erected as directed
1 no. 6A/16A universal plug-switch combined. 3 nos.
6A Switch 3 nos. 6A 5 pin Plug
For Tissino Type Accessories Ea.
Providing & erecting Switch board for Computer or
electric apparatus consisting of following modular
type accessories mounted with PVC/ Metallic
concealed/ open box with single mounting base
24 frame covered with textured/ metallic/ white front
plate, modules erected with necessary connections
as directed 1 no. 6A/16A universal plug-switch
combined. 3 nos. 6A Switch 3 nos. 6A 5 pin Plug
For Modular Type Accessories
Hanging bed switch / Bell push 5A erected on existing Ea.
26 Providing & erecting ISI marked 3 pin plug top.
(a) for 5/6 A., 240 V Ea.
(b) for 15/16A, 240 V Ea.
Supplying & erecting Approved make call bell
indicator with buzzing sound and Red light
indicating lamp with Red light button to attend the
call suitable for 240 v 50 c/s supply to be
28 Call bell / Buzzer,250 volts, complete erected. Ea.
Call bell gong type suitable for 230 volts, 50 c/s. Ea.
29 AC supply complete Erected
Decorative call bell Ting-tong box type 250 volts Ea.
complete erected
Supplying & erecting Electronic Type Cordless Call
Bell erected on PVC/Metal board having portable
31 bell push working on D.C. & bell on 230V A.C. Ea.
supply with cells / battery
Providing & erecting insulated socket 3P+N+E with Ea.
32 Plug16A rating which is comprised of Four pole MCB
slot and insulated socket IP40 cat-III
Providing & erecting insulated socket 3P+N+E with Ea.
Plug 32A rating which is comprised of Four pole
MCB slot and insulated socket IP40 cat-III
Approved make High pressure sodium vapour
34 lamp, Tubular/Elliptical type 70W. 230/240/250V.
erected, if required.
Approved make High pressure sodium vapour
35 lamp, Tubular/Elliptical type 150W, 230/240/250V,
erected , if required
Approved make High pressure sodium vapour
36 lamp, Tubular/Elliptical type 250W, 230/240/250V,
erected , if required
Approved make High pressure sodium vapour
37 lamp, Tubular/Elliptical type 400W,
230/240/250V, erected , if required
Erection & connection charges for 16A / 32 A DP
(a) on existing wooden block / A.I. frame Ea.
(b) on polished wooden block. Ea.
(c) on angle iron frame duly painted with Red Ea.
Providing Approved make Triple Pole Cast Iron
39 Clad Switch & rewirable Fuse with neutral link
415/500 V confirming to IS
Erection & connection Charges For 16A/32A TP
(a) on existing wooden block / A.I.frame Ea.
(b) on polished wooden block. Ea.
(c) on angle iron frame duly painted with Red Ea.
Providing Approved make Triple Pole Metal / Iron
42 Clad Switch & Fuse with neutral link 415/500
V confirming to IS
Erection & connection Charges for 63A/100A TP
(a) on existing wooden block / A.I.frame Ea.
(b) Erection on angle iron frame duly painted with Ea.
Providing Approved make Triple Pole Metal Clad
Switch Fuse Unit 415/500 V. with HRC fuse of
suitable load and neutral link confirming to IS.
Providing and erecting Approved make Four pole
moulded case circuit breaker having breaking
capacity ICU of 25 KA. at 415 V, having normal
current rating up to 25 A to 100A. with Fixed thermal
& magnetic release suitable to work on A.C. supply
50 c/s. with all internal connections, spreader tinned
copper & complete erected in existing 16 G.M.S.
housing. Cat-III
Providing and erecting Approved make Four pole
moulded case circuit breaker having breaking
capacity ICU of 35 KA. at 415 V. having normal
current rating 125A with Fixed thermal & magnetic
46 release suitable to work on A.C.supply 50 c/s. with all Ea.
internal connections, spreader tinned copper &
complete erected in existing 16 G.M.S. housing.
Providing and erecting Approved make Four pole
moulded case circuit breaker having breaking
capacity ICU of 35 KA. at 415 V. having Normal
current rating 200A. with variable Thermal & magnetic
47 release suitable to work on A.C.supply 50 c/s. with all Ea.
internal connections, spreader tinned copper &
complete erected in existing 16 G.M.S.housing
Providing and erecting Approved make Four pole
moulded case circuit breaker having breaking
capacity ICU of 35 KA. and above at 415 V . having
normal current rating 250A. with variable thermal &
48 magnetic release suitable to work on A.C.supply 50 Ea.
c/s. with all internal connections, spreader tinned
copper & complete erected in existing 16 G.M.S.
providing and erecting Miniature circuit breaker single
pole 6A to 25A suitable to operate on 240 V
49 A.C. system and having breaking capacity
KA to be erected in existing box. confirming to IS
8828/1996 with ISI Mark
Providing & erecting 240 V MCB double pole
switch for motor & inductive load (C Curve)
50 having 10 KA breaking capacity & confirms to IS
: 8828 in existing box having following
(A) 6 to 32 Amp.
Providing & erecting 415 V MCB Four Pole for Motor
& Inductive Load (C Curve) having 10KA breaking
capacity & confirms to IS :8828 in existing box having
following capacity
(a) 6 to 32 Amp.
Providing & erecting 415 V MCB three Pole for Motor
& Inductive Load (C Curve) having 10KA breaking
capacity & confirms to IS :8828 in existing box having
following capacity
(a) 6 to 32 Amp.
Providing and erecting Sheet Steel powder
coated MCB distribution board - flush / surface
mounted fitted with busbar, neutral link, earth bar
and DIN rail, Conforms to IS 8623-1 & 3, IEC
53 61439-1 & 3 without MCB to house appropriate nos.
of MCBs. (The DBs should be used of same
company of MCB to be used) suitable for
(A) single phase incoming and horizontal single
(b) sheet steel double door (IP-43)
(B) three phase incoming and single phase
horizontal type outgoing Per phase isolation type
(b) sheet steel double door
Providing and erecting Sheet Steel powder
coated Vertical MCB distribution board (VTPN) - flush
/ surface mounted double door (IP54) fitted with
insulated copper busbar, isolated neutral link, earth
bar and DIN rail, confirming to IS 13032 and BS 5486-
1986,IP-54 suitable for 63/100 AMP TPN MCCB +
RCCB as incomer and three phase outgoing as per
following .(The DBs should be used of same
company of MCB to be used)
(A)4 way outgoing Ea.
(B)6 way outgoing Ea.
(C)8 way outgoing Ea.
(D)12 way outgoing Ea.
Providing and erecting Sheet Steel powder
coated Vertical MCB distribution board (VTPN) flush /
surface mounted double door (IP54) fitted with
copper insulated busbar, isolated neutral bar, earth
bar and DIN rail, Conforms to IS 8623-1 & 3, IEC
55 61439-1 & 3, suitable for 250 AMP TPN MCCB +
RCCB as incomer and three phase outgoing as
per following. (The DBs should be used of same
company of MCB to be used)
(A)4 way outgoing Ea.
(B)6 way outgoing Ea.
(C)8 way outgoing Ea.
(D)12 way outgoing Ea.
providing and erecting Approved make RCCBs
conforming to IS: 12640 and having sensitivity of
mA and Short Circuit withstand capacity of 10 KA
and suitable for operation on single phase 240 V,
56 50Hz. having characteristic of quick action &
tripping with all advance feature & do not incorporate
any electronic component. for following Max. rating
erected as directed
(ii) 40Amps. DP
(iii) 63 Amps. DP
Providing and erecting Approved make RCCBs
conforming to IS:12640 and having sensitivity of
mA and Short Circuit withstand capacity of 10 KA
and suitable for operation on 3 phase and neutral
57 415V, 50Hz. having characteristic of quick action &
tripping with all advance feature & do not incorporate
any electronic component for following Max. rating
erected as directed.
(ii) 40Amps. FP
(iii) 63 Amps. FP
(iv) 100 Amps. FP (100 mA Sensitivity)
Providing and erecting busbar chamber
confirming to IS-375 fabricated from 16 G.M.S. sheet,
dust & vermin proof having hinged door with rubber
gasket and necessary busbar supports with
COPPER busbar having current density not more
than 1.6 Amp. / sq.mm (Rated current / cross section
58 area) duly wrapped with colour insulation tape for
phase sequence, three phase & neutral each
suitable for following current capacity with
necessary painting mounted on wall or pedestal
frame of required size with necessary connections.
(A) Suitable for 63/100 Amp. capacity Rn.Mtr
Providing and erecting required size HOT deep
Galvanised iron strip for earthing of H.T. , OCB/ ACB/
59 Transformer LT panel board, Motors etc. using proper Kg.
Providing and erecting required size Copper strip
for earthing of H.T. OCB / ACB/
60 Transformer, LT panel board, Motors etc. using Kg.
Providing and erecting Annealed bare Copper wire
Providing and erecting HOT deep Galvanised iron
62 strip wire 8 to 16 SWG. Kg.
Supplying & erecting earth pit of minimum bore
dia.150mm size approved make Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-
1987 made of corrosion free hot dipped G.I. Pipes
having Outer pipe dia of 50mm having 80-200
Micron galvanising, Inner pipe dia of 25 mm having
200-250 Micron galvanising, connection terminal dia
of 12mm with constant ohmic value surrounded by
highly conductive compound with high charge
dissipation suitable for following type of applications
63 with chamber and heavy duty cover. (approved make
OEM has to submit test certificate) & having back
filling compound of (B) Inner chemical (CCM
Compound)- Resistivity:- 0.2 / meter testing as per
IEC 62561-2017, Voltage drop:- < 1 volt at no load &
dry form, Sulphar content:- <2%(C) Back fill
Compound:- Earthing compound should be
capable to retain moisture for long time
Necessary test report must be submitted.
(a) For Electrical Installation up to 440V in
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
(b)For Electrical installation up to 11 KV in
Length of Pipe : 2.00 mtrs
Back filling Compound :1 no. Bag of 25 Kg.
(c) For Electrical Installation covering Transformer
Neutrals, Lightning arrester Earthing, A.C.Plant &
Sensitive Computer System (like Automation,
SCADA) i.e independent Earthing in normal soil. Ea.
Length of Pipe : 3.00 mtrs
Back filling Compound :2 nos Bags of 25 Kg.
Supplying & erecting in earthpit of minimum bore
dia. 225mm size approved make Safe Earthing
Electrode consisting Pipe-in-Pipe Technology as
per IS 3043-1987 made of corrosion free hot
dipped G.I.Pipes having Outer pipe dia of 80 mm
having 80-200 Micron galvanising, Inner pipe dia of
40 mm having 200-250 Micron galvanising,
65 connection terminal dia of 14 mm with constant
ohmic value surrounded by highly conductive
compound with high charge dissipation suitable for
following type of applications with chamber and
heavy duty cover.(approved make OEM has to
submit test certificate including value of earth
resistane of installation.
[A] For electrical installation up to 440 V Length of
Back filling compound - 1 Nos. of Bag of
[B] For Electrical installation up to 11 KV
located in other than normal soil i.e. Soft Rock,
Marshy Soil etc. Ea.
-Length of Pipe : 2 mtr
-Back filling Compound :1 no. Bag of 25 Kg.
[C] For Electrical Installation covering Transformer
Neutrals, Lightning arrester Earthing, A.C.Plant &
Sensitive Computer System (like Automation,
SCADA) i.e. independent Earthing located in other
than normal soil i.e. Soft Rock, Marshy Soil etc.. Ea.
-Length of Pipe : 3 Mtrs.
-Back filling Compound :2 nos Bags of 25 Kg.
Supplying & erecting funnel type earthing
having earth plate of following size burred in
specifically prepared earth pit 3 mtr. below ground
with 40 kg. charcoal and salt with alternate layers of
charcoal & salt, 20mm.dia. G.I. pipe with Funnel with
a wire mesh for watering & bricks masonry block, C.I.
Cover complete as per para 7.3 of IS 3043 with
64 necessary length of double Galvanised Iron / copper
earth wire No 6 SWG bolted with lug to the plate and
covered in 12 mm dia. G.I. pipe 2.5 mtr long complete
connected to the nearest switch gear with end socket
as per direction & duly tested by earth tester
confirming to IS (As per drawing) with following
(A) With 30 x 30 x 0.35 cms: C.I. earth plate Ea.
Supplying and erecting LED indoor fittings with LEDs
of wattage 0.2 Watt to 0.5 Watt assembled on
single MCPCB, with housing used as a heat sink
shall be made of co- extruded polycarbonate
channel with diffuser part in needed opal finish with
company mark/name 160V to 270V, Power Factor
more than 0.9, THD < 15%, CCT 3000 K to 6500K,
Luminaire efficacy > 85 lumens/watt,LED LED driver
65 efficiency > 85 % (fitting required LM-79 & LM-80
Certificates) (NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity
between the ranges shown.)
(A) Tube Light with integral driver
(i) 5-10 Watts, Surge-2 KV, IP-20, conventional 1 to
(ii) 18-20 Watts, Surge - 2KV, IP-20, conventional
Supplying and erecting led lamps with following
wattage capacity of 220 to 240 voltage, minimum
15000 burning hours life, 500V in built-surge
66 protection, Polycarbonate diffuser, mounting suitable
for E14 / E27 / B22 lamp holders, pf >=
(A) LED Lamps integral type, with PC diffuser
suitable LAMP holder
(i) 2 to 3 watts
(ii) 5 to 8 watts
(iii) 10 to 15 watts
(iv) 16 to 20 watts
(v) 21 to 30 watts
Supplying and erecting LED indoor fittings with LEDs
of wattage 0.2 Watt to 0.5 Watt assembled on single
MCPCB, with housing used as a heat sink shall be
made of thick sheet Steel conforming to
IS:513/CRCA/ aluminium pressure die cast powder
coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with
company mark/name 160V to 270V, Power Factor
more than 0.9, THD < 15%, CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens / watt, LED driver
efficiency > 85% ( fitting required LM-79 & LM-80
Certificates) (NOTE:Below description have shown
ranges of Wattage capacity of LED fittings. The
Engineer incharge may select any wattage capacity
between the ranges shown.)
(A) Square/ Circular shaped Surface / Recessed
Mount Downlight with provision for spring loaded
mounting clips complete.IP20
(i) 5-9 watts,Surge-2 KV
(ii) 11-15 watts, Surge-2 KV
(iii) 16-20 watts, Surge-2 KV
(iv) 22-24 watts, Surge-2 KV
(B) LED Panel Light with provision for Plane front
frame with translucent cover fixed to housing
(i)up to 8 Watts,4" x 4", Surge-2 KV
(ii) 10 watts, 4" x 4", Surge-2 KV
(iii) 12-15 watts, 6" x 6", Surge-2 KV
(iv) 18 to 20 watts, 8" x 8", Surge- 2 KV
(v) 24 watts, 12" x 12" , Surge-2 KV
(vi) 36 watts, 24" x 24", Surge- 2KV
(vii) from 45 to 48 watts, 24" x 24", Surge-2 KV
Supplying and erecting LED street light / Flood light
fittings with High power White LEDs wattage of
Watt and above assembled on single MCPCB,
efficiency more than 130 lm/w and corrosion free
High pressure die cast aluminum housing with
smooth finish powder coated and heat sink
extruded aluminium with diffuser and Polycarbonate
optics/ lenses, with toughened glass with company
mark/name engraved or embossed 160 to 270 V,
68 Power Factor more than 0.95, THD < 10 %, CCT
3000 K to 5700K, Uniformity ratio >0.45, Luminaire
efficacy >100 lumens/ watt LED driver efficiency >
85 %.( fittings required LM- 79 & LM-80 certificates)
(NOTE: Below description have shown ranges of
Wattage capacity of LED fittings. The Engineer
incharge may select any wattage capacity
between the ranges shown.)
(A) Street Light (IP-65), Surge protection -4KV
integral and ,Light must have 440VAC line
supply with over-voltage protection.
(i) above 36 to 47 watts
(ii) above 48 to 59 Watts
(iii) Above 60 to 89 watts
(iv) above 90 to 119 watts
(v)above 120 to 159 watts
(vi)above 160 to 199 watts
(vii)above 200 to 250 watts
(B) Flood Light(IP-65), Surge protection - 4KV integral
and Light must have 440VAC line supply with over-
voltage protection.
(i) above 36 to 47 watts
(ii) above 48 to 59 Watts
(iii) Above 60 to 89 watts
(iv) above 90 to 119 watts
(v) above 120 to 159 watts
(vi) above 160 to 199 watts
(vii) above 200 to 250 watts
(C)Post Top Lantern LED fitting comprises of finish
cast aluminum spigot and spun aluminum canopy
fixed with opal polycarbonate, pipe arrangement for
vertical mounting driver and accessories wired upto
terminal block. IP
Supplying & erecting XLPE(IS:7098)(I)-88 ISI
69 unarmoured copper cable 1.1 KV grade to be
erected as directed of following size.
(A) 2 core 2.5 Sq. mm Mtr.
(B) 2 core 4 sq.mm Mtr.
(C) 2 core 6 Sq. mm Mtr.
(D) 2 core 10 Sq. mm Mtr.
(E) 3 core 2.5 Sq. mm Mtr.
(F) 3 core 4 Sq. mm Mtr.
(G) 3 core 6 Sq. mm Mtr.
(H) 3 core 10 Sq. mm Mtr.
(I) 3 core 16 Sq. mm Mtr.
(J) 4 core 2.5 Sq. mm Mtr.
(K) 4 core 4 Sq. mm Mtr.
(L) 4 core 6 Sq. mm Mtr.
(M) 4 core 10 Sq. mm Mtr.
(N) 4 core 16 Sq. mm Mtr.
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium conductor
70 for 1.1 KV. to be laid on wall with necessary
clamps or in existing trench / pipe of following size of
(A) 3 core 2.5 Sq. mm Mtr.
(B) 3 core 4 Sq. mm Mtr.
(C) 3 core 6 Sq. mm Mtr.
(D) 3 core 10 Sq. mm Mtr.
(E) 3 core 16 Sq. mm Mtr.
(F) 3 core 25 Sq. mm Mtr.
(G) 3 core 35 Sq. mm Mtr.
(H) 3 core 50 Sq. mm Mtr.
(I) 3 core 70 Sq. mm Mtr.
(J) 3 core 95 Sq. mm Mtr.
(K) 3 core 120 Sq. mm Mtr.
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Aluminium conductor for
71 1.1 KV to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables
(A) 3 1/2 core 25 Sq. mm ( 16 Sq. mm 1/2 Mtr.
(B) 3 1/2 core 35 Sq. mm (16 Sq. mm 1/2 Mtr.
(C) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm Mtr.
(D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 Mtr.
(E) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 Mtr.
(F) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 Mtr.
(G) 3 1/2 core 150 Sq. mm ( 70 Sq. mm 1/2 core) Mtr.
(H) 3 1/2 core 185 Sq. mm ( 95 Sq. mm 1/2 core) Mtr.
(I) 3 1/2 core 240 Sq. mm( 120 Sq. mm 1/2 Mtr.
(J) 3 1/2 core 300 Sq.mm ( 150 Sq. Mm 1/2 Mtr.
(K) 3 1/2 core 400 Sq.mm ( 185 Sq. mm 1/2 core) Mtr.
(L) 3 1/2 core 500 Sq.mm ( 240 Sq. mm 1/2 core) Mtr.
(M) 3 1/2 core 630 sq. mm (300 sq.mm 1/2 core) Mtr.
Providing & laying approved make Double
walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with
72 necessary connecting accessories of same material
at required depth in existing trench for laying of
cable. below ground / road surface for enclosing
(A)50 mm outer dia Mtr.
(B)63mm outer dia Mtr.
(C))90 mm outer dia Mtr.
(D)120 mm outer dia. Mtr.
Providing & laying approved make ISI marked Rigid
PVC pipe having 6Kg / cm2 (Class-3) to be erected
73 at road crossing on or floor as directed for laying of
cable. The pipes as following size of dia & weight
(A) 40 mm inner Dia. (1.68 Kg / 6 RMT) Mtr.
(B) 50 mm inner Dia. (2.5Kg/6RMT) Mtr.
(C) 63 mm inner Dia. (4 Kg / 6RMT) Mtr.
(D) 75 mm inner Dia. (5.5 Kg/6RMT) Mtr.
(E) 90 mm inner Dia (8.0 Kg / 6RMT) Mtr.
(F) 110 mm inner Dia. (11.63 Kg/6 RMT) Mtr.
Providing and, fixing heavy duty flange type brass
double compression type cable gland with rubber
74 ring for PVC insulated armoured cable complete
with out going tails, insulating tape etc for following
size of cables.
(A) 3 & 1/2 / 4 core 25 Sq. mm Ea.
(B) 3 & 1/2 core 35/50 Sq. mm Ea.
(C) 3 & 1/2 core 70 Sq. mm Ea.
(D) 3 & 1/2 core 95 Sq. mm Ea.
(E) 3 & 1/2 core 120 Sq. mm Ea.
(F) 3 & 1/2 core 150 Sq. mm Ea.
(G) 3 & 1/2 core 185 Sq. mm Ea.
(H) 3 & 1/2 core 240 Sq. mm Ea.
(I) 3 & 1/2 core 300 Sq. mm Ea.
(J) 3 & 1/2 core 400 Sq. mm Ea.
(K) 3 & 1/2 core 500 Sq. mm Ea.
Solder less crimping type Aluminium lugs
conforming to IS suitable for cable of following
size evenly crimped with high pressure tool &
75 connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved
Disconnecting the cable connection and Providing
straight joint with PVC mould using heat shrink/cast
resin type epoxy compound Insulating material and
making the joint complete using necessary in
lineconnectors, hardener, earth continuity
connection, spacers etc. and reconnecting the
same & ensure the joint resistance within the limits
(A) up to 25 Sq mm Cable Ea.
(B) 35 to 95 Sq. mm cable. Ea.
(C) 120 to 300 Sq. mm cable. Ea.
Providing & erecting Approved make Ceiling Fan
with double ball bearing ISI mark with Condenser
230 volt A.C.50 Hz 1200 mm sweep complete
77 having 3 blades aluminium body and blade sets Ea.
having ornamental design shanks, canopy erected
with earthing. [ Make shall be approved by Engineer
Supplying & erecting fan hook box of 10 mm
M.S. round bar bounded to the RCC bars up to 50mm
length each side and pierced through a 16 Gauge
78 M.S. box / Heavy Duty PVC box complete Ea.
erected concealed in Ceiling with necessary
Supplying & erecting approved make low noise
79 decorative exhaust fan having square frame ABS
body with inbuilt lowers & square frame.
200mm with 1350RPM Cat.II Ea.
250mm with 1350 RPM Cat.II Ea.
Supplying & erecting single phaseapproved make
industrial exhaust fan suitable for medium duty ring
80 mounted low noise operation suitable for medium
duty having following dia size and maximum speed
[A] 300-305 mm dia 900 RPM
[E] 450 mm dia 1400 RPM
Supplying and erecting approved make Bracket fan
of 230 volt, A.C. 50 Cy/s., 400/450 mm sweep
complete erected on wall or with lead Cores and
connections complete.
Supplying and erecting approved make double ball
bearing oscillating type Heavy duty bracket fan with
Aluminium Blades A.C. 23OV. 50cy/s wall mounted
with height adjustment and rotary tilting device
complete with guard, wall bracket, mounting
accessories as directed.
Supplying and erecting approved make pedestal fan
A.C. 230V. 50 Cy/s. 400 mm sweep oscillating
83 type and adjustable, height complete with guard
regulator, & standard lead flexible wires and plug top.
Supplying and erecting approved make
Pedestal Circulatory fan A.C. 230 V. 50 Cy/s.
84 mm sweep and adjustable height complete with
guard, & standard lead flexible wires and plug top.
Providing and erecting Approved make Ceiling fan
with double ball bearing ISI mark with condenser
A.C. 23OV 50 c/s 1200 mm. sweep complete,
85 canopy erected on existing hook or clamp with Ea.
earthing. [Make shall be approved by Engineer in
Supply, Installation, Testing and Commissioning of
suitable sweep, BEE 5 Star rated, Ceiling fan with
Brush Less Direct Current (BLDC) permanent ferrite
magnet Motor, class of insulation: B, Rust free 3 nos.
Aluminium blades, 2 nos. canopies, shackle kit with
earthing provision, copper winding, Power factor not <
0.9, Service Value (CMM/W) minimum 6.85, Air
delivery minimum 215 CMM, 350 RPM, 230v
(tolerance as per IS: 374-2019), THD < 10%, with
86 remote unit for Speed Control and all remaining
accessories including safety pin, nut bolts, washers,
temperature rise = 75 degree C (Max.), suitable for
140 to 285 Voltage and rectifier circuit with surge,
over current and overload protection, 50 Hz,
Single phase AC Supply, earthing etc. Complete as
required.[ Make shall be approved by Engineer in
(B) 1200 mm Sweep (48") Ea.
Supply, Installation, Testing and
Commissioning of suitable sweep, BEE 5 Star
rated, Ceiling fan with Brush Less Direct
Current (BLDC) permanent ferrite magnet
Motor, class of insulation: B, Rust free 3 nos.
Aluminium blades, 2 nos. canopies, shackle
kit with earthing provision, copper winding,
Power factor not < 0.9, Service Value (CMM/W)
minimum 6.85, Air delivery minimum 215 CMM,
RPM,230v (tolerance as per IS:374-2019), THD <
10%, compitible with electronic regulator unit for
87 Speed Control and all remaining accessories Ea.
including safety pin, nut bolts, washers,
temperature rise = 75 degree C (Max.),
suitable for 140 to 285 Voltage and rectifier
circuit with surge, over current and overload
protection , 50 Hz, Single phase AC Supply,
earthing etc. Complete as required.[ Make shall be
approved by Engineer in Charge] (A) 1200 mm
Supplying and erecting 19 / 20 mm. nominal bore
Medium Class M.S. Pipe down rod erected duly
painted for fan complete with proper insulation without
leakage and earthing.
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor for
89 1.1 KV. to be laid on wall with necessary clamps or in
existing trench / pipe at road crossing or floor of
following size of cables.
(A) 4 core 2.5 Sq. mm Mtr
(B) 4 core 4 Sq. mm Mtr
(C) 4 core 6 Sq. mm Mtr
Providing and erecting XLPE(IS:7098)(I)-88 ISI
armoured cable multistrand Copper conductor for
1.1 KV. to be laid on wall with necessary clamps or in
existing trench / pipe at road crossing or floor of
following size of cables.
(A) 4 core 10 Sq. mm Mtr
(B) 4 core 16 Sq. mm Mtr
(C) 4 core 25Sq. mm Mtr
Making trench in soft soil of suitable width of 90 cm
deep for laying cable or locating the fault all over the
91 run and back filling the same and making the surface Mtr.
as normal ground.
Making trench in Hard Murrum / Tar Road of suitable
width of 90 cm or required depth for laying any size
92 of cable or locating the fault all over the run and back Mtr.
filling the same and making the surface as normal
Disconnecting the cable connection and Providing
straight joint with PVC mould using heat shrink /cast
resin type epoxy compound Insulating material and
making the joint complete using necessary in line
93 connectors, hardener, earth continuity connection,
spacers etc. and reconnecting the same & ensure the
joint resistance within the limits as per IS.
(A) up to 25 Sq mm Cable Ea.
(B) 35 to 95 Sq. mm cable. Ea.
(C) 120 to 300 Sq. mm cable. Ea.
Supplying and erecting Direct - On - Line Starter with
18 A. rating contactor and with 3.5 Amp. 18A range
directly operated in totally insulated elegant enclosure
94 for single phase operation up to 3 HP as per IS
complete erected on P.W. Block with necessary
Supplying and erecting Direct-on-line, Starter with
15A.rating contractor and with 4-14A. range, directly
operated thermal overload relay in sheet steel
95 enclosure for 3phase 415V.50 c/s. A.C. motor up to
7.5 H.P.complete erected on P.W. Block with
necessary connection.
Supplying and erecting push button operated fully
automatic Star-Delta starter with 3 Nos.of 32A. rating
contactors and. 1 No. of directly operated thermal
96 overload relay having 20-32A range in sheet steel
enclosure for 3 phase 415V. 50 c/s. A.C. motors up to
35 H.P. complete erected on
(B) For erection on Angle iron frame add to
Supplying & erecting approved make self-priming
domestic monoblock water pump with 0.5 H.P. motor,
suitable for operation on 230 volts 50 c/s. AC supply
with metallic flange, delivery and discharge of 32 LPM
at 10 mtrs.head.
Supplying & erecting approved make self-priming
domestic monoblock water pump with 1 H.P motor,
suitable for operation on 230 volts, 50c/s. AC supply
with metallic flange, and M.S. impeller delivery and
following discharge
(a) 40 LPM at 24 mtrs. head suitable for 25mm dia.
Delivery- Cat.III
(b) 100 LPM at 14 mtrs. head suitable for 25 mm dia.
delivery - Cat.III
Providing & erecting open well type horizontal mono
99 block pump set with stainless steel body having
following specification
(C) 1 H.P. single phase open well motor pump set
suitable for 185 LPM discharge @ 25 mtr. head,
suitable for 32 mm dia. Delivery pipe with control
Providing & erecting open well horizontal mono block
100 pump set with cast iron body, complete for three
phase submersible motor having
[C] For 3 HP 3 phase open well horizontal mono block
pump set suitable for 85 LPM to 270 LPM @ 11 mtr
to 33 mtr head suitable for 50/65 mm dia delivery pipe
[D] For 5 HP 3 phase open well horizontal mono block
pump set suitable for 1350 LPM to 310 LPM @ 10 to
42 Mtr head suitable for 50/65 mm dia delivery pipe
[E] For 7.5 HP 3 phase open well horizontal mono
block pump set suitable for 1550 LPM to 370 LPM @
13.5 Mtr to 42 Mtr head suitable for 65/75 mm dia
[F] For 10 HP 3 phase open well horizontal mono
block pump set suitable for 1725 LPM to 940 LPM @
15 to 36 MTR head suitable for 65/80 mm dia delivery
[G] For 12.5 HP 3 phase open well horizontal mono
block pump set suitable for 1530 LPM to 950 LPM @
24 to 40 MTR head suitable for 65/80 mm dia
[H] For 15 HP 3 phase open well horizontal mono
block pump set suitable for 1600 LPM to 1025 LPM
@ 33 to 42 MTR head suitable for 65 /80 mm dia
Supplying & erecting approved make Automatic liquid
level controller 6A. with sensor testing as per
instruction of Engineer in charge on site complete
with wiring connection with existing wires , with
copper conductor from pump to upper and lower tank.
Supplying & erecting approved make motor control
cubical panel (Direct - on - line) made from 16 G.
CRCA sheet duly epoxy powder painted inside and
outside with hinged doors and locking, arrangement
consisting of suitable size of ON- OFF isolator (AC -
3/23duty) main fuses, single phasing preventer,
indicating lamps for R- Y - B phases, overload relay,
102 Automatic water level controller, Ammeter, Voltmeter
each with two way selector switch incoming, wires
duly socket crimped, main contactor & overload relay,
start - stop push buttons, to be erected on angle iron
frame grouted on wall as directed. The isolator,
overload relay & contactors will be of L & T, Siemens
or BCH make only.
(a) DOL up to 5.0 H.P. Ea.
(b) DOL for 7.5 H.P. Ea.
Supplying & erecting approved make 3 phase motor
control cubical panel ( Star - Delta) made from16 G.
CRCA sheet duly painted with epoxy powder painted
inside and outside with hinged doors and locking
arrangement, consisting of suitable size of ON- OFF
isolator (AC - 3/23 duty) main fuses, single phasing
preventer cum water level. Guard (Complete unit),
Toggle switch to by pass Single phase preventer cum
WLG, indicating lamps for R- Y- B phases, over load
relay, Automatic water level controller, Ammeter &
Voltmeter each with two way selector switch incoming
103 wires duly socket Crimped, Panel to be erected on
angle iron frame grouted on wall as directed. Star
Delta & main contactor, overload relay, thermal /
Electronic Star delta cutoff timer, start - stop push
buttons. The isolator overload relay & contactors of
L& T, Siemens or Cuttler Hamer make only. Panel to
be erected on angle iron frame ground on wall.
Providing and erecting ISI marked PVC insulated
104 PVC Sheathed Flat flexible Submersible copper cable
approved make of following Size.
(a) 3 Core x 1.5 Sq. mm. Mtr.
(b) 3 Core x 2.5 Sq. mm. Mtr.
(c) 3 Core x 4 Sq. mm Mtr.
(d) 3 Core x 6 Sq. mm. Mtr.
(e) 3 Core x 10 Sq. mm. Mtr.
(f) 3 Core x 16 Sq. mm. Mtr.
(g)3 Core x 25 Sq. mm Mtr.
Removing the pump set from foundation after
removing suction & discharge connection pipes & all
wiring connections taking it to workshop & open it for
fault finding , refitting the same, after carrying out
105 repairing, taking back on site refitting on foundation
with pipe & wiring connections & put in working
condition. (Excludes cost of repairing. Includes to &
from transportation)
(a) Up to 3 HP Job
(b) Above 3 HP to 7.5 HP Job
(c) 10 Hp to 20 HP Job
Removing deteriorated gasket, gland packing, washer
106 nuts & bolts before refitting of motor pump set.
(b) Above 3 HP to 7.5 HP Ea
Rewinding of 230V single phase motor as per original
winding design by using super enamelled copper
107 Wire and putting the same in working condition as per
(B) Upton 0.75 HP Ea
(C) Upton 1.0 HP Ea
Rewinding of 3 phase 440V motor as per original
winding design by using super enamelled copper
108 Wire and putting the same in working condition as per
Rewinding of 5 H.P., 3 phase 440V motor as per
original winding design by using super enamelled
copper Wire and putting the same in working
condition as per original.
Rewinding of 7.5 H.P., 3 phase 440V motor as per
original winding design by using super enamelled
110 copper Wire and putting the same in working Ea
condition as per original.
Rewinding of 10 H.P., 3 phase 440V motor as per
original winding design by using super enamelled
copper Wire and putting the same in working
condition as per original.
Rewinding single phase 230V motor for open well
horizontal mono pump set by using polycab copper
112 winding wire & putting the same in working order for
pump capacity of
Shifting of Split A.C. The Scope includes dismantling,
shifting, re-installing & re-commissioning of the units
including topping up of Refrigerant gas, minor civil
116 work wiring existing piping M S Stand electrical Ea
cabling with PVC drown piping for 1.00, 1.5 & 2.0 TR
Overhauling and servicing the Split type
A.C.MACHINES by Chemical cleaning of the
117 condenser, cooling coil etc. by veniclean /Eq. job
material, water & cleaning all necessary parts and
putting the machine in working order.
Providing and erecting approved make split
airconditioning unit consisting of copper condensing
unit with fan motor, hermetically sealed rotary
compressor with accessories etc. duly connected
separately erected evaporating unit and blower motor
with its accessories by means of extra supplied
proper insulated copper tubing,drain PVC pipes
suitable for (cost includes powder coated Stand, Eco
Friendly green gas charging, 15A plug top & Remote
Control) with necessary core cutting.Premium Cat:O-
Genral,Mitsubishi Electric
(1)For ISEER range(KWH/KWH)(3.1 to 3.9)
(B) for 1 ton capacity Nos.
(C) for 1.5 ton capacity Nos.
(D) for 2 ton capacity Nos.
Supplying & installing MS standard type stand
mounting for outdoor unit of Split A.C. upto 4 TR
capacity erected with necessary hardware materials
Providing and erecting water cooler having storage
capacity 80Ltr. & cooling capacity 40 Ltr.per hour @
an ambient temp of 45˚ C.The outlet temp of the
water should drop by 15˚ C within a hour, The water
cooler should be comprising of hermetically sealed
120 compressor, fan motor, condensing unit, water tank Nos.
surrounded by evaporating coil, thermostats, relay
etc. complete with necessary inlet & outlet
connection. The body of water cooler will be made
from Stainless Steel.
Providing & erecting water cooler having storage
capacity 150 Ltr. & cooling capacity 150 Ltr per hour
@ an ambient temp of 45˚ C. The outlet temp. of the
water should drop by 15˚C within a hour, The water
cooler should be comprising of hermetically sealed
121 compressor, fan motor, condensing unit, water tank Nos.
surrounded by evaporating, coil, thermostats, relay
etc. complete with necessary inlet & outlet
connection. The body of water cooler will be made
from Stainless Steel.
Supplying and erecting water filter cum purifier with
ultra violate technology. (Aquaguard /waterdoc model
122 or equivalent symphony/ crystal/videocon model) Nos.
Supplying approved make domestic refrigerator of
123 50/60 Ltr storage capacity, single phase minimum 3 Nos.
Supplying approved make domestic refrigerator of
124 165 Ltr to 185 Ltr storage capacity, single phase Nos.
minimum 3 star rating.
carry out RCC Core cutting- up to 100 mm dia.
/200mm thick Wall/beam/slab with providing PVC
125 pipe of 3 mm thick inside and necessary finishing on Job
both ends of wall .
carry out RCC Core cutting- up to 100 mm
dia./300mm thick Wall/beam/slab with
126 providing PVC pipe of 3 mm thick inside and Job
necessary finishing on both ends of wall .
SITC of CAT6 UTP 23AWG Solid: Per Meter
127 (approved by competent authority i.e. not belowthe Ea.
rank of executive engg.
SITC of Patch Panel Cat 6 UTP Keystone Type-
128 Port-Fully Loaded (approved by competent authority Ea.
i.e. not belowthe rank of executive engg.
Providing Membrane 40 x 40 size for 100 to 250 Ltr.
Industrial R.O. Plant
Providing Row Water Pump of 0.5 H.P.
operating on 230V A.C. ,50 Hz supply &
Putting the same in working condition for 100 to
Ltr. Industrial R.O. Plant
Providing Vessel Service , Sand & Carbom media
131 and multi port valve multimedia material for 100 to Job
250 Ltr. Industrial R.O. Plant
Providing Erecting auto R.O. work new panel board
132 for 100 to 250 Ltr. Industrial R.O. Plant Job
Repairing high pressure pump upto 1 H.P.
133 operating on 230V A.C., 50 Hz supply, winding & Job
Bearing100 to 250 Ltr. Industrial R.O. Plant
Repairing solenoid valve and replacing coil 100 to
250 Ltr. Industrial R.O. Plant
Providing and Erecting 20" wound and spun Cartridge
135 100 to 250 Ltr. Industrial R.O. Plant Job
Providing & Erecting Hardware Material (elbow, pipe,
136 union etc.) 100 to 250 Ltr. Job
Industrial R.O. Plant
Repairing and servicing labour charges for 100 to
Ltr. R.O. System
138 Supply and Installation of New 100 Ltr. R.O. Plant Nos.
Dismantling charge for Split A.C. Machine (upto
Shifting (Transportation) charges for watercooler /
Supply M.S. Bottom stand for up to 80 litre storage
141 capacity water cooler Nos.
Supply M.S. Bottom stand for Above 80 litre to
litre storage capacity water cooler
Supplying and erecting insulated pair of soft copper
tubing open or concealed including power and control
143 cable,necessary PVC drain pipes for Split/Cassette Rmt.
AC machine up to 4 TR capacity
Plywood of 12 mm supply & Installation for Split A.C.
144 Machine IDU for any size Nos.
Zari work for copper piping & cabling with zari puran
145 using POP/White cement (including material) Ft.
146 Dismentling Work of Water cooler Nos.
147 Reinstallation Work of Water cooler Nos.
148 Dismentling Work of Water purifier Nos.
149 Reinstallation Work of Water puirfier Nos.
Condensor Replacement with copper condenser of
150 1.5 TR A.C. Machine with pressure testing & gas Job
Condensor Replacement with copper condenser of
151 2.0 TR A.C. Machine with pressure testing & gas Job
Condensor Replacement of watercooler with pressure
152 testing & gas charging Job
New Remote for Split Ac
Electronic timer for Split/window Ac
Supply and Installation of UPVC pipe outlet
Connections from Water Cooler with UPVC Pipe & all
155 accessories (Tee, Elbow, Union, Cock etc.) fixing with Job
clamp (a)upto 10 ft.
Supply and Installation of UPVC pipe outlet
Connections from Water Cooler with UPVC Pipe & all
accessories (Tee, Elbow,Union, Cock etc.) fixing with
clamp (b)upto 11 -20 ft.
157 Supply and installation of SS Tap for water cooler Nos
S.I.T.C. of Booster pump for water purifier
S.I.T.C. of New water level sensor for water purifier
160 S.I.T.C. of Bowl filter set for water purifier Nos
S.I.T.C. of new minimum 3 star outdoor unit of spilt ac
161 for ISEER Range (kWH/KWH)(3.1 to 3.9)New Nos
outdoor unit of Split ac
S.I.T.C. of new minimum 3 star indoor unit of spilt ac
162 for ISEER Range (kWH/KWH)(3.1 to 3.9)New Nos
outdoor unit of Split ac
163 Cable Laying in Kachha ( per mt. length) Mtr
164 Cable Laying in Pakka ( per mt. length) Mtr
Supply & Labour charges for Modification work of
relocation of JB upto 1.2 mtr from bottom. Scope of
work :- Hole drilling and fixing of JB with Loop In Loop
Out cable in GI / DWC / UPVC pipe (Rate extra for
pipe) with connection of fixtures and earthing wire
Decorative Post Top light fixtures - SITC of decorative
Post top lantern type Light Fixture with die cast
aluminum body and PC protector indirect type for
lighting distribution suitable for max. 45 Watt LED
lamp of low glare with minimum IP66 protection for
optical compartment of light fixture, Minimum IK
Having luminous Efficasy >= 80 lumens / watt at
colour temperature 3000/ 4000 K, CRI >70, with
mtr long 3 core FRLS cable,CRI >80,with surge
protection device of 10/10KV, Driver non integral
Type, with EPDM/Silicon rubber gasket with all
necessary Hadware, Internal Wiring with Lamp,
integral Ballast etc. complete in all respect with all
required accessories as per the detailed technical
specifications. Lighti fixtute to be provided with cross
holes with fixing allen KEY to be matched with
Existing Pole hole and if not Contractor Has to make
Hole as per LIght Fixture. Colour of light fixture should
be MRF anchor gray shade no 624 or as approved
SRFDCL. Make:- (Lighting Technologies / Keselec/ K-
Lite / Philips / Crompton / Bajaj /Ensave / Acon )
Decorative Post Top light fixtures - SITC of decorative
Post top lantern type Light Fixture with die cast
aluminum body and PC protector Direct type for
lighting distribution suitable for max. 45 Watt LED
lamp of low glare with minimum IP66 protection for
optical compartment of light fixture, Minimum IK
Having luminous Efficasy >= 80 lumens / watt at
colour temperature 3000/ 4000 K, CRI >70, with
mtr long 3 core FRLS cable,CRI >80,with surge
protection device of 10/10KV, Driver non integral
Type, with EPDM / Silicon rubber gasket with all
necessary Hadware, Internal Wiring with Lamp,
167 integral Ballast etc. complete in all respect with all No.
required accessories as per the detailed technical
specifications. Lighti fixtute to be provided with cross
holes with fixing allen KEY to be matched with
Existing Pole hole and if not Contractor Has to make
Hole as per LIght Fixture. Colour of light fixture should
be MRF anchor gray shade no 624 or as approved
SRFDCL. Make:- (Lighting Technologies /Keselec / K-
Lite /Philips/Crompton/Bajaj/Ensave/Acon )
For providing Wiremen at various premises of
168 SRFDCL (8 hrs. shift) Each
For Providing Wiremen Helper at various premises of
169 SRFDCL Each
170 630 Amp Spreader Terminals Ea
170 630 Amp Rotary Handle Ea
172 630 Amp Shunt Trip Ea
173 ELR With CBCT(for 630 amp FF MCCB) Ea
174 400A Spreader Terminals Ea
175 400A Rotary Handle Ea
176 400A Shunt Trip Ea
177 ELR With CBCT(for 400 amp FF MCCB) Ea
178 95 sq.mm. Cu Flexible Wire mtr
179 70 sq.mm. Cu Flexible Wire mtr
180 50 sq.mm. Cu Flexible Wire mtr
181 35 sq.mm. Cu Flexible Wire mtr
182 25 sq.mm. Cu Flexible Wire mtr
183 10 sq.mm. Cu Flexible Wire mtr
184 6 sq.mm. Cu Flexible Wire mtr
185 4 sq.mm. Cu Flexible Wire mtr
186 2.5 Sqmm lead wire Mtr
187 1.5 Sqmm lead Wire Mtr
188 1.5/2.5 sqmm Cu Lugs Ea
189 Sintex Junction Box 40x30 Ea
190 Sintex Junction Box 28x17 Ea
191 Sintex Junction Box 25x25 Ea
192 MCB Channel Mtr
193 (R-Y-B) LED Lamp Ea
194 B LED Lamp Ea
195 ELR With CBCT Ea
196 100A Spreader Terminals Ea
197 100A Rotary Handle Ea
198 100A Shunt Release Ea
wooden Computer Borad (4+4 no 15 amp switch and
199 15 amp socket with 10 mtr 2.5 sq mm 3 core cable Ea
with 15 amp top)
200 Lamp Holder Ea
201 5 mm Hylem Sheet mtr
202 100 mm Exhuast fan Ea
203 150 mm Exhaust fan Ea
204 200 mm Exhaust Fan Ea
205 250 mm Exhuast fan Ea
206 12 Moduler PVC Board Ea
207 6 modular PVC Board Ea
Supplying & Installing approved make air cooler
(desert cooler) 230Volts, having brass nuts-bolts, with
fan, pump, drip proof motor, filter pads, confirming to
208 IS-3315,separate control switch for pump & fan
complete with 5 mtrs. long 3core flexible copper Core
and top erected on suitable stand with following air
displacement capacity.
(B) With FRP (moulded fiber) body
(iii) 85 cu. mtrs / minute
(C)with ABS plastic body
(ii) 3000 cu. mtrs Hr.
Supplying & Installing approved make air cooler, All
plastic body injection molding made of 100% virgin
Poly propylene high impact resistance material, motor
should be 3 speed aluminum body with copper
winding with 950RPM/220Volts/50HZ, should be "P2"
type, cooling media should be 4 inch cellulose pad
209 with maximum 5 mm flute, all hardware SS
Power cord and 3 Pin molded plug top, should be ball
valve for automatic water refilling, should have water
drainage system, should have complete cover for air
cooler to protect when unused.
(A) motor 175W, fan 21-inch, sound maximum 63db,
air delivery 6000 CMH, can cover 900 square feet,
tank 60 Liters, cooling pad size 770x100x700 mm.
(B) motor 490W, fan should be one piece aluminum
pressure die cast 30" with air delivery 18000 CMH,
can cover 2500 square feet, sound maximum 67db, Ea.
tank 90 Liters, cooling pad size 1100x100x1150 mm.
Supply & Fixing Of 50W led Driver with input voltage
Ac 90-310v,5060Hz,output voltage Dc 50-75V,Output
current 750mA +-5% complete with
coonections,testing and commissioning
Supplying & erecting approved make time switch with
single pole air break contacts suitable for
V.15/16A.complete with self starting motor driven
clock ‘ON’ &’ OFF’ automatic arrangement at any
predetermined time during each 24 hours,With nickel
cadmium rechargeable battery backup erected as
Supplying & erecting approved make Digital time
switch having lithium cell 6 years operative and
operate battery backup 1 channel day clock with
memory programme, suitable to operate on 240V +
5%, 16A with, floating contacts Minimum switching
setup time 1 minimum & LCD display. Also comprised
212 permanent ON/OFF switching. Programming Ea.
switches & housed in fire proof thermoplastic
enclosure & transparent cover erected as required
with necessary connection erected as directed.
Supplying and erecting approved make Segment time
switch suitable for 230V+10%16A. floating contacts
with 24 hour dial having15/30 min. segments with
early manual override switching for on & off without
influencing the program sequence with quartz time
213 switch With power reserve, housed in fire proof Ea.
thermoplastic enclosure & transparent cover terminal
covers erected as required wire necessary
connection erected as directed.
Providing and erecting approved make light control
unit suitable to operate on 230V +20% having
ON/OFF delay time of 30-50 seconds and having
214 facility for Auto/manual system having two LDR lens Ea.
to intensity light having capacity of 5A complete
erected on section pillar with pipe and stand.
Supplying & erecting power contactor ,AC3 duty for
215 time switch complete erected as per direction Cat III
(A) 2 Pole 250V 12 Amp. Ea
(B) 2 pole 250V 32 Amp. Ea
(C) 4 pole 440V 16 Amp. Ea
(D) 4 pole 440V 40 Amp. Ea
Supplying & erecting approved make IP 55 grade
Company fabricated Timer Panel of following capacity
for switch On-Off street lights on time scheduling
basis made from 16G CRCA sheet duly epoxy power
painted inside and outside with hinged doors and
locking arrangement consisting of suitable size of
providng and erecting Approved make energy meter
217 230V, 50 Hz AC up to 20A erected as directed with
three year replacement guarantee.
providng and erecting Approved make single phase
electronic energy meter rating 5A/20A/40A based on
218 ASIC (Application Specific integral circuit) digital
technology with accuracy Class-I, temper proof, free
from effect of external magnetic field with phase,
earth,IIIreverse and impulse indications, 6 digit electro-
providng and erecting Approved make energy meter
3 phase 4 wire unbalanced load rating, 10A to
Amp. based on ASIC(Application specific Integral
Circuits) digital technology with accuracy Class - 1
temper proof, free from effect of external magnetic
field with 3 phase indication, earth & impulse
Supplying & erecting D.C.P. type fire extinguisher for
219 following capacity cartridge type with gun metal cap
150 gram CO2 gas cartridge, powder and brackets
[A] For 5 KgtoCapacity
IS 2171 1985 and complete erected with
[B] For 10 KG Capacity Ea
Supplying & erecting carbon dioxide (CO2) fire
extinguisher user of following capacity with necessary
clamps made from 50 x 6 mm M.S. Flat with nut &
bolts grouted in wall complete.
[A] For 4.5 Kg Capacity Ea
[B] For 5.5 / 6.5 KG Capacity Ea
Supplying & erecting ABC powder type 'Ceasefire'
type Fire extinguisher as per IS 13849 or 1 Kg
221 capacity with necessary clamp for erection on wall Ea
222 Solder less crimping type Copper lugs conforming to
Sq.mmof following size evenly crimped Ea.
Providing and erecting Approved make Four pole
moulded case circuit breaker having breaking
capacity ICU of 50 KA and above at 415 V having
Normal current rating 400A. with variable Thermal &
223 magnetic release suitable to work on A.C.supply
Hz. With all internal connections, spreader tinned
copper & complete erected in existing 16 G.M.S.
ICS=100% of ICU only Cat III Ea.
Providing and erecting Approved make Four pole
moulded case circuit breaker having breaking
capacity ICU of 50 K.A. and above at 415 V having
normal current rating up to 630A. with variable
thermal & magnetic release suitable to work on
A.C.supply 50 Hz. with all internal connections,
ICS=100% of ICU only Cat III Ea.
Providing and erecting metallic vitrified danger notice
board as per language suggested by engineer
225 incharge for MEDIUM VOLTAGE installation to be Ea.
erected as per IS-2551.
Providing and erecting metallic vitrified danger notice
board as per language suggested by engineer
226 incharge for HIGH VOLTAGE installation to be Ea.
erected as per IS.-2551.
Providing & erecting Medium Voltage Danger Notice
Board sticker as per language suggested by engineer
227 incharge of standard size as per IS-2551 Ea
Providing & erecting High Voltage Danger Notice
Board sticker as per language suggested by engineer
228 incharge of standard size-as per IS 2551 Ea
Supply of Fiberglass Step (A Type) Ladder - 4 FT
having following specifications.
It should have nonconductive Structural moulded top,
with Slots to keep tools close at hand, inside
Spreader Braces, Aluminium Feet with thick rubber
tread, nonconductive Full channel Fibreglass and two
229 pairs of gusset support at the bottom step. All gussets Ea.
are heavy duty steel.
Capacity : 300 lbs.
Step Size : 3” Width : 19” “Approx. Spread :
Wt. :8 Kg Approx. Cube : 4.05’
Supply of Fibreglass Step (A Type) Ladder - 6 FT
having following specifications :
It should have nonconductive Structural moulded top,
with Slots to keep tools close at hand, inside
Spreader Braces, Aluminium Feet with thick rubber
tread, nonconductive Full channel Fibreglass and two
230 pairs of gusset support at the bottom step. All gussets Ea.
are heavy duty steel.
Capacity : 300 lbs. Step Size : 3” Width : 23”
Spread : 41” Approx.
Wt. : 11 Kg Approx. Cube : 6.2’
Supply of Fibreglass Step (A Type)Ladder-8 FT
having following specifications :
It should have nonconductive Structural moulded top,
with Slots to keep tools close at hand, inside
Spreader Braces, Aluminium Feet with thick rubber
tread, nonconductive Full channel Fibreglass and two
231 pairs of gusset support at the bottom step. All gussets Ea.
are heavy duty steel.
Capacity : 300 lbs. Step Size : 3”
Width : 26” Approx. Spread : 54” Approx. Wt. : 15 Kg
Supply of Fibreglass Step (A Type) Ladder - 10 FT
having following specifications :
It should have nonconductive Structural moulded top,
with Slots to keep tools close at hand, inside
Spreader Braces, Aluminium Feet with thick rubber
tread, nonconductive Full channel Fibreglass, two
232 pairs of gusset support at the bottom step and All Ea.
gussets are heavy duty steel.
Capacity : 300 lbs. Step Size : 3” Width : 29”
Approx. Spread : 66”Approx. Wt. : 19 Kg Approx.
Supply of Fibreglass Step Trestle (A Type) Ladder -
6 FT having following specifications :
It should have heavy gauge steel hinges suitable for
industrial application ,inside Spreader Braces,
Aluminium Feet with thick rubber tread,
nonconductive Full channel Fiberglass,two pairs of
233 gusset support at the bottom step and All gussets Ea.
are heavy duty steel. It should have steps on both the
sides for climbing. Capacity : 300 lbs." Step Width : 3”
Bottom Width:23” Approx.
Spread : 52”Approx.Wt.:13 Kg Approx. Cube :
Supply of Fibreglass Step Trestle (A Type) Ladder -
8 FT having following specifications :
It should have heavy gauge steel hinges suitable for
industrial application ,inside Spreader Braces,
Aluminium Feet with thick rubber tread,
nonconductive Full channel Fibreglass, two pairs of
234 gusset support at the bottom step and All gussets are Ea.
heavy duty steel. It should have steps on both the
sides for climbing. Capacity:300 lbs. Step Width:3”
Bottom Width : 26” Approx.
Spread : 67” “Approx. Wt. : 20 Kg Approx.
Supply of Fibreglass Step Trestle (A Type) Ladder -
10 FT having following specifications :
It should have heavy gauge steel hinges suitable for
industrial application ,inside Spreader Braces
,Aluminium Feet with thick rubber tread,
nonconductive Full channel Fibreglass ,two pairs of
235 gusset support at the bottom step and All Ea.
gussets are heavy duty steel. It should have steps on
both the sides for climbing. Capacity : 300 lbs." Step
Width : 4” Bottom Width : 29” Approx. Spread : 83”
Approx. Wt. : 27 Kg Approx. Cube : 13.44’
Supply of Fibreglass Platform Step (A Type) Ladder -
6 FT having following specifications :
It should have large fully serrated
platform 15” wide 20” deep which locks ladder
,Aluminium feet with thick rubber tread, top rail guard
236 to serve as a railing, two pairs of gusset support at Ea.
the bottom step and All gussets are heavy duty steel.
Capacity : 300 lbs. Step Width : 3’ Approx.
spread : 50” Width : 26.5” Approx. Wt. : 16 Kg
Approx. Cube : 8.15’"
Supply of Fibreglass Platform Step (A Type) Ladder -
8 FT having following specifications :
It should have large fully serrated
platform 15” wide 20” deep which locks ladder,
Aluminium feet with thick rubber tread, top rail guard
237 to serve as a railing, two pairs of gusset support at Ea.
the bottom step and All gussets are heavy duty steel.
Capacity : 300 lbs. Step Width : 3’ Approx.
spread : 62” Width : 29.5” Approx. Wt. : 22 Kg
Supply of Fibreglass Platform Step (A Type) Ladder -
10 FT having following specifications :
It should have large fully serrated
platform 15” wide 20” deep which locks ladder
Aluminium feet with thick rubber tread, top rail guard
238 to serve as a railing, two pairs of gusset support at Ea.
the bottom step and All gussets are heavy duty steel.
Capacity : 300 lbs. Step Width : 4’ Approx.
spread : 75” Width : 32” Approx. Wt. : 29 Kg
Supply of Fibreglass Platform Step (A Type) Ladder -
15 FT having following specifications :
It should have large fully serrated
platform 15” wide 20” deep which locks ladder
239 Aluminium feet with thick rubber tread, top rail guard Ea.
to serve as a railing, two pairs of gusset support at
the bottom step and All gussets are heavy duty steel.
Capacity : 300 lbs
Supply of Fibreglass Platform Step (A Type) Ladder -
18 FT having following specifications :
It should have large fully serrated
platform 15” wide 20” deep which locks ladder
240 Aluminium feet with thick rubber tread, top rail guard Ea.
to serve as a railing, two pairs of gusset support at
the bottom step and All gussets are heavy duty steel.
Capacity : 300 lbs.
Liaisoning work for additional load for requirement,
electrical power connection charges and inspector
241 approval for power(to be paid to concern electrical Job
power supplier company)
Liaisoning work for power supply procurement/To
resume the service in case of electrical break down
242 with site visit,Test report submission ,meter
conection,fualt,rectification in T.P/UGVSL and also all
Single site only one service connection Per
Single site more than1 up to 10 no. of service Per
242.2 connection
Single site more than 10 no of service connection Per
Providing ,Supplying and Operating Required
vehicals/mashinaries on riverfront for
243 diff.maintanance work including diesel,driver etc.all
complete for working 8 hrs shift as directed by
243.1 for Tractor with trolly shift
RGB Amplifier Inpitu/output voltage:DC 12-24V,Total
244 output of current with required Accessories for no
Lighting letters
RGB Controler Inpitu/output voltage:DC 12-24V for
Lighting letters
246 Jumper for LED Lighting Letters no
PART A TOTAL AMOUNT
PART A TOTAL AMOUNT
PART-B LIST OF BUYBACK ITEMS
Existing Tubelight with tube and its accessories
Swicthboard - 2 module to 16 module (with all related
248 accessories like switch, Socket, regulator, conduit) Each
249 Copper Wire size from 1.0 Sqmm to 6.0 Sqmm Each
Aluminium cable size from 10 Sqmm to 25 Sqmm
251 Copper cable size from 10 Sqmm to 25 Sqmm Each
252 SP MCB size from 6 to 25 A Each
253 Dp MCB size from 25 to 63 A Each
254 FP MCB size from 63 to 200 A Each
Exhasut Fan 200 mm - 300 mm (metal and PVC
256 Ceiling Fan - 1200mm with Fan rode and hook Each
257 Wall Fan size- 400 mm - 600mm Each
258 Distribuiton Board SPN - 4 Way to 16 Way Each
259 Distribuiton Board TPN - 4 Way to 16 Way Each
260 Flood Light - 50 to 200 Watt Each
Any OLD LED Fitting surface/recess - 9 Watt to
262 Existing Streetlight Poles Each
263 Existing Streetlight fittings Each
264 Decorative Post top fittings Each
265 Up to 80 ltr capacity water cooler Each
266 150/150 ltr/hr capacity water cooler Each
267 water purifier up to any capacity Each
PART-B TOTAL AMOUNT
PART-B TOTAL AMOUNT
Net Amount (Part A - Part B)
Total Amount without GST
Total Amount without GST
Total Amount with GST
Total Amount with GST
I/We am/are willing to carry out work at_________________%above or ___________%
Below the estimated cost mentioned above.
The amount of my/our tender works out as under Estimated cost put up to tender:-
Add__________% Above:-Rs.____________OR :-Deduct___________%Below:-
Net Amout in Rs.(After Additional/deduction):-__________________________________
NOTE:- (1)The Quoted Rate shall be inclusive of all taxes GST.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
vol-1 Techniacl Bid.pdf
BOQ.pdf
Download all tender documents and submit your bid