Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹52,971Accepted-AOC NORTH BEYPORE CALICUT 15 KERALA | KOZHIKODE | KERALA | 612906 | 1 | Accepted-AOC L1 accepted | |
| 2 | Rejected-Technical | - | Rejected-Technical L3 rejected | |
| 3 | Rejected-Technical | - | Rejected-Technical L2 rejected |
Tender Value
₹58,574
EMD Value
₹1,464
Closing Date
1 Jan 2024, 5:00 pmClosed
SECRETARY PUTHUPPADY
PUTHUPPADY GRAMAPANCHAYATH OFFICE 673586
403/24-KUNHUKULAM VANITHA THOZHIL PARISHEELANA KENDRAM RE WIRING
2023_DP_634170_1
SC1/9235/3/24
Open Tender
Electrical Works
Item Rate
60 days
KUNHUKULAM
Please refer Tender documents.
5 documents required · 5 mandatory
₹655
Yes
₹1,464
Yes
19 Feb 2024
21 Dec 2023
3 Jan 2024
21 Dec 2023
1 Jan 2024
21 Dec 2023
Amount
Rewiring kunhukulam Vanitha thozhil pariseelana kendram
OD413102/2022-2023:Dismanling and removing the existing old damaged and rusted meter board including main switch. handing over the same to muncipal/Panchayath authorities. make good the wall including Plastering and Painting
OD413103/2022-2023:Dismantling and removing the existing old damaged and rusted main switch along with MS/Syntex box Handing over the same to muncipal/Panchayath authorities make good wall including plastering and painting
OD413104/2022-2023: Dismantling old PVC Conduit with wire and other Electrical fittings which are not in useand handling over the same to the Departmental authority with proper written acknoledgement
OD413105/2022-2023:32A SP&NDisconnector fuse switc unit in sheet enclosure with ISI marked including HRC fuse link front handle type ( Havels make without GST)
OD413106/2022-2023:Supply and fixing 20A HRC Fuse With 20A fuse link with connection in the existing meter board
OD413107/2022-2023: Supply and installation of sheet steel phosphatased and painted,dust and vermin proof of MCB DB including copper/brass and DIN rail suitable for fixing MCB/Isolator, etc fixed on existing pannel board using suitable bolt and nut ,8way single phase
1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
1.11:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
1.12:Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
1.17.29:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 6 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.2:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.2 way 5/6 amps switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.27.6:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
1.17.4:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
OD413181/2022-2023:Supply, installation , testing and commissioning of the following sizea of exhaust fans in the existing opening , fixing necessary bolt and nuts making good the damages etc. as required including giving connections with required length of 24/02 mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire confirming to relevant ISS. 250 mm sweep light duty Exhaust fan in plastic body with self opening lowers working on 230 V AC single phase
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
OD424312/2022-2023:Supply, Conveyance, Installation and testing of robust & reliable LED Bulk head with IP65 Protection and IK08 impact resistance suitable for wall mounting application including giving connection as required. (Make: Philips (Model: WT140W LED7S CW PSU S1 PC9405) or any other equivalent make
SASINDRAN E
SASI T
Bidder Name
gopakumar.kv
SASINDRAN E
SASI T
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_962035.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .