| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 LAccepted-AOC WING NO 7 2 10 PREMNAGAR DEHRADUN UK | L1 | Accepted-AOC Acceptance of contract | |
| 2 | L2₹34.7 L+₹1.1 L (3.23%)Rejected-AOC VIII BADWALA ARKEDIA GRANT PO PREMNAGAR DEHRADUN | DEHRADUN | DEHRADUN | UTTARAKHAND | L2 | Rejected-AOC R | |
| 3 | L3₹37.2 L+₹3.6 L (10.7%)Rejected-AOC 208 DOON VIHAR RAJPUR ROAD JAKHAN DEHRADUN UK | L3 | Rejected-AOC R | |
| 4 | L4₹40.0 L+₹6.4 L (18.9%)Rejected-AOC 27 CHITRAKOOT ENCLAVE NEAR ANURAG NURSARY DEHRADUN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-AOC R | |
| 5 | L5₹41.3 L+₹7.7 L (23.0%)Rejected-AOC INDEX NO E 72 HQ CWE HILLS VILL PO MEHUWALA MAPHI NEAR RAJKIYA INTER COLLEGE DEHRADUN UK | DEHRADUN | UTTARAKHAND | 248001 | L5 | Rejected-AOC R |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
25 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE IMA Dehradun
GE IMA Dehradun
PROVN OF CERTAIN SPL REPAIR AT IMA DEHRADUN
2023_MES_624390_1
GE/IMA/T-55 of 2023-2024 9357/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
GE IMA Dehradun
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
₹96,000
Yes
12 Jan 2024
20 Oct 2023
27 Nov 2023
20 Oct 2023
25 Nov 2023
11 Nov 2023
Amount
Demolition of brick work or stone/boulder masonry built in cement mortar including removal out side the IMA premises complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan exc. 6 mtr mean radius built in cement mortar (1:6) complete all as specified and directed.
Taking down cement plaster including raking out joints hacking for key, scrubbing down with water etc including removal out side the IMA premises complete all as specified and directed.
M&L for 12 mm thick ready mix plaster internal and extrenal plastring on brick or concrete surface mix with watrer as per manufacture,s specification including providing & mixing water proofing compound as per manufacture,s specifications , surface finished even & smooth complete all as specified and directed.Make : Ultratech /ACC / Birla /Unicrete
Supply only integral water proofing compound liquid complete.
Taking down chowkats or frames with shutters (without taking off shutter from frame) area n.exc 1.5 Sqm complete all as specified and directed.
Taking down chowkats or frames exc 1.50 Sqm and n.exc 4 Sqm each with shutters (with out taking off shutters from the frames & refixing in same opening complete all as specified and directed.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified.
S & F Steel windows box type with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars dovetailed or welded incl cutting holes in wall for inserting holdfast and making good to the dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified.
All as per item No. 09 above but without glazing bar.
S & F 4mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.50 Sqm in each pane complete all as specified and directed.
Dismantling Asbestos cement sheets in roof coverings incl ridge etc complete.
S&F pre-painted galvalume aluminium zinc coating GI based Plain steeel sheet 0.50mm thick an colour having tensile strength of 550 Mpa and 150 GSM as in roof covering/cladding to wall fixed with self tapping screws all as specified. Make:- Tata Blue scope/ JSW Color on+/ Charminar
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steeel sheet 0.50mm thick an colour having tensile strength of 550 Mpa and 150 GSM as in roof covering/cladding to wall fixed with self tapping screws all as specified. Make:- Tata Blue scope/ JSW Color on+/ Charminar
S&F pre-painted galvalume aluminium zinc coating GI based tile profile corrugated steeel sheet 0.50mm thick an colour having tensile strength of 550 Mpa and 150 GSM as in roof covering/cladding to wall fixed with self tapping screws all as specified. Tata Blue Scope, JSW Steel ( colour on +) / Charminar
M&L for a coat of cold applied bituminous primer over cleaned surface @ 0.30 Kg/Sqm and applying on coat of hot blown bitumen 85/25 grade @ 1.20 Kg/Sqm followed by APP modified five layer ploymeric membrane 3mm thick, minimum wt 3.60 kg/Sqm reinforced with polyester non-woven fabric (weighing not less than 150gms/Sqm ) manufactured by authorrised manufacturer specified in particular specification laid as per the manufacturer instruction with side over lap of 75 mm & end over lap of 100mm & tucked into the chases on vertical surfaces if required & finally finished with bituminous aluminum paint @ 0.20 Kg/Sqm complete all as specified including taking down existing roof treatment from the RCC slab, cleaning off all foreign material by wire brushing clenaing off surfce and removal of spoil out side the IMA premises complete all as directed. Make:- STP Ltd/ Sikka/ Torch Tar
Dismantling wrought iron or mild steel work of any description complete.
M&L 15 mm thick screed bed in cement mortar 1:6 over concrete surface finished even & smooth with out extra cement with water proofing compound @ 3 % by weight of cement or as per manufacturer instructions while the concrete is green ( WPC shall be measured and paid separately)
S&F of Structural steel, rolled section as in main and cross beams, hips and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates conforming to Fe-410 W (Gde-E-250)all as specified and directed.Make:- TATA/JINDAL/JSW STEEL
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete including removal out side the IMA premises.
Providing & fixing false ceiling at all heights with GRG (Glass Fiber Reinforced Gypsum) false ciling tiles of Seze 595x595 mm of approved texture, design and patterns having moisture content less than 2% humidity resistance of 99%, NRC 0.60 to 0.75 as per IS 8225 :1987, Noncombustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanized iron section of 00.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32mm of length 3000mm , cross-T of size 15x32mm of length 1200mm and secondary intermediate cross-T of szie 15x32mm of length 600mm to form grid module of size 600 x600 mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e. 50mm long, 8 mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod up to 1000mm length and L-shape level adjuster of size 85x25x2mm. Galvanized iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-In-Charge. with semi perforated 12mm thick micro tegular edged GRG false ceiling tiles. Make:- Diamond ceiling/ Gyproc/ USG Boral
M&L cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone agg) as in coping, benching cills, pcc gola, seismic and other similar bands and the like including weathering sliglitely rounded or chamfered angles and throating as directed.
M&L for kota stone slab 18-20mm thick in raiser of steps, skirting, dado and pillar laid over 10 mm thick cement screed in CM 1:6 and jointed with pigment to match the shade of of the slab including rubbing and mirror polishing complete all as specified.
M&L for machine cut kota stone flooring 18-20mm thick over 15 mm thick cement mortar screed bed in cement mortar 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified.
Dismantling Stone slab and tiles of any description and type in floor apron etc complete.
Demolition of concrete on ground floor and paving n,exe 15cm thickness(below or above ground level) complete including removal outside the IMA premises.
M&L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggt) as in sub base filling and mass concrete complete finished evenand fair all as specified and directed
Demolition of Concrete of any description and in any position not otherwise specifically provided for complete including removal outside the IMA premises.
M & L for 75mm thick PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in floors,plinth protection etc finished even and smooth with using extra cement complete all as specified and directed.
Preparation of new wooden surfaces of any description over 10 Cm width or girth and applying two coats of synthetic enemelled paint over one a coat of pink primer complete all as specified and directed.
Preparation of new steel surfaces exc. 10 Cm width or girth and applying two coats of synthetic enemelled paint over one coat red oxide promer complete all as specified and directed.
M&L for complete removal of existing treatment all as directed Engr-in-Charge.
M&L for applying 1.00 mm thick wall putty on walls for smooth finish all as directed Engr-in-Charge
Preparation of new surfaces and applying two coat of distemper oil emulsion (OBD) over a coat of primer complete all as specified and directed.
M&L preparation of wall plastered or unplastered surfaces and applying two coats of cement based paint over a coat of cement primer complete all as specified.
Preparation old painted wooden surfaces any description over 10 cm width or girth and applying One coat of synthetic enemelled paint including all preparation complete all as specified and directed.
Preparation old steel surfaces exc. 10 cm width or girth and applying One coat of synthetic enemelled paint including all preparation complete all as specified and directed.
M&L for Hand packing (any thickness ) at back of wall over arches etc, and raising or lowering to the required level complete all as directed.
M&L for Hard core of gauge n,exc 63mm , deposited , spread and levelled in layers not exc 15cm thick , weatered and rammed and to true surface complete.
M & L for Mild steel, plain, black 1.60 mm thick, sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required in hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc. with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc complete all as specified.
Taking down old U/S main switches, Sheatmetal enclosures DB including MCCBs, MCBs etc including making good to the disturbed surface of wall complete all as directed.
Taking down old unsv T/L, Lamp,Security light of any size and capacity all as directed.
Taking down carefully submain wiring/Service wire including all accessories without disturbing existing wiring fittings fixtures etc and making good to the disturbed surfaces all as directed and as specified in any type and size all as directed.
Material and labour for point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLSH having multi stranded copper conductor of 1.5 Sq mm nominal cross sectional area drawn in existing conealed conduit with all fitting and fixing accessories and 1.5 Sq mm PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxes 1.6 mm thick, 60 mm deep of required size factory made for mounting switch, regulators etc with and including 3 mm thick plastic hylam laminated sheet cover (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint inside for mounting switches, sockets etc complete for the following. Make of wire: Havells, Polycab, Anchor Note: (i) The quoted rates shall be deemed to be inclusive for making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. (ii) Point wiring & earth wire shall be connected to each & every sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.
One light point controlled by one, one way switch 5 Amps
One fan point point controlled by one, one way switch 5 Amps .
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item No 45 above but with stranded copper conductor 2.5 Sq mm (nominal area), two single core, PVC insulated cable 1100 Volt grade ISI-694 marked for 3 pin, 15 Amp socket outlet, independent, including PVC insulated stranded copper conductor 2.5 Sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly.
Supply and fix Switch piano, flush type, single pole one way, 5 Amp complete all specified and as directed Make:- SSK/ Havells Reo/ Anchor Penta PC
Supply and fix Switch piano, flush type, single pole ,one way15 Amp complete all specified and as directed Make:- SSK/ Havells Reo/ Anchor Penta PC
Supply and fix Socket outlet, multipurpose, 2 in 1, 5 pin, 5 Amp complete all specified and as directed Make:- SSK/ Havells Reo/ Anchor Penta PC
Supply and fix Socket outlet, multipurpose, 2 in 1, 5 pin, 15 Amp complete all specified and as directed Make:- SSK/ Havells Reo/ Anchor Penta PC
Supply and fix Electronic step rotary type fan regulator 100W, 230 volts AC 50Hz complete all as specified and directed Make:- SSK/ Havells Reo/ Anchor Penta PC
Material and labour for ceiling rose, 63.5 mm dia, ISI marked, three terminal of polycarbonate/isolated body complete all as directed. Make: SSK/ Havells Reo/ Anchor Penta PC
Supply and Fix in repair LED batten light fitting 4 feet of lumens 2500 lumens, wall mounted ,high pressure die cast alluminium, fully diffused ,system efficacy 125L/W ,polycarbonated diffuser,IP-20 ,high bright LED lamp, colour temp not less than 5700 Cool Day Light,colour rending index not less than 80 ,life not less than 20000 hrs, inbuilt electronic driver, PF not less than 0.90 and THD less than 10 % with operating voltage 140-270V AC, 50 Hz, surge protection minimum 2.5KV including,connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose including taking down old unsv Tube light fitting complete all as specified and directed . Make: - PHILIPS /CROMPTON/HAVELLS
Supply and Fix in repais LED 2 x2 feet Surface/recess mounted light fitting of lumens 3600 lumens ,CRCA housing,Polycarbonated Cover for More protection , fully diffused ,system efficacy 100L/W,Epoxy powder coated with any additional treatment for smooth and anti corrosive finish., IP-20 and IK-20,high bright LED lamp, colour temp not less than down 6500 Cool Day Ligh,colour rending index not less than 80 ,life not less than 25000 hrs, inbuilt electronic driver, PF not less than 0.90 and THD less than 20 % with operating voltage 140-270 V AC, 50 Hz, surge protection minimum 2 KV, including connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose including taking down old unsv light fitting complete all as specified and directed. Make: - PHILIPS /CROMPTON/HAVELLS
Supply and Fix in repairs LED street/Security wall mounted light fitting of lumens 2550 lm ,Single Piece High pressure die cast aluminium,system efficacy 1100L/W,Epoxy powder coated with any additional treatment for smooth and anti corrosive finish, fully diffused ,Polycarbonated Cover for More protection ,inbuilt electronic driver IP 66 ,High bright LED with Lens, colour temp Not less than 5700 Cool Day Light,colour rending index not less than 70 ,life not less than 50000 hrs,inbuilt electronic driver with 325V Auto Cut off Restart feature & 440V Phase to Phase protection till 8 hour, PF not less than 0.95 and THD less than 10% at full load with operating voltage 140-270V AC, 50 Hz ,surge protection minimum 4 KV, including connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose including taking down old unsv light fitting complete all as specified and directed. Make: - PHILIPS /CROPTON/HAVELLS
Supply and fix ceiling Fan complete with blades,down rods ,230 volts ,1200 mm sweep ,min air delivery 210 CFM with service value 6.00 BEE ,with Brushless direct current motor (BLDC) with hanging hook complete all as specified. Make:- Atomberg/ Havells/ Orient
Supply and fix metal body exhaust fan 300 mm sweep, 1400 rpm 230 volts 5h Hz, energy saving model single phase copper wound motor, grey in colour complete with blade, box type louvers etc including taking down old unsv serviceable exhaust fan and deposited to the store. complete all as specified and directed. Make:- Havells/ Orient/ Usha
Material and labour for earthing with galvanised steel earth plate electrode 60cmX60cmX 6mm thick burried directly in ground (earth pit not less than2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm thick GI wire by means of nuts,bolts,check nuts & washers of galvanized iron or steel,protected by 15mm bore light grade galvanised iron pipe and connected to main switch board,including all necessary excavation & earth work in hard dense soill including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternate layers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover10mm thick hinged to CI frame and 6mm MS rod for handle and necessary testing complete all as shown in electrical plate No 3 of SSR part-I all as specified and directed.(one earthing for each main Panel )
S & F MCB DB SPW 16 way complying with IEC 61439 -1 & 3., sheet metal enclosures double door .The DBs should be supplied with tin platted insulated copper bus bar rated for 100A. 240 volts 2 in 1 shutter (Metal Door) with IK09 type with blanking plates where required and IP 43 degree protection, the DB door should be hinged type and possible to reversible at site.The DB door shall have overhang, to gel with wall properly.The DB shall be supplied with all insulated N. Bar riveted on Din channel frame and should not restrict cable entry from top or bottom.The DB shall have plastic knobs on shield to hold complete all as directed. Make:- Havells/Indo Asian/HPL
S & F MCB SP /SPN complying to IS/IEC 60898, 240 volts 'C' Curve 10 KA with energy limiting class 3. The MCB shall have 50% lower watt loss as required by IS/IEC 60898 from 6A to 63A . The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault. The MCB shall have safety shutter to avoid any wrong insertion of cable. The MCB shall have the termination capacity of 35 Sq mm. The MCB shall have electrical life 20,000 operations up to 32A and 12,000 operation up to 63A including connection with suitable size copper lugs complete all as directed. Make:- Havells/Indo Asian/HPL
MCB SP 240 volts, 50 Hz capacity 6-32 Amps
SPN 240 volts, 50 Hz capacity 40 to 63 Amps
Supply and laying in replacement XLPE insulated armoured heavy duty electric cable with aluminium conductor ,1100 volts gradeof size 10 sqmm x 2 core fixed on wall in PVC pipe or burried in ground up to 30 cm including taking down old unsv cable all as specified and directed. Make:- Havells/ Polycab/ Gemscab Ind Ltd.
Aggrawal Builders and Furnishers
M/s caspur construction company
M/S PUNDIR BUILDERS
M/s RK ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .