| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.5 LAccepted-AOC VIKASH NAGAR ROAD NO 1 NEAR GAUSHALA RAMGARH CANTT JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | L1 | Accepted-AOC LOWEST AND REASONABLE | |
| 2 | L2₹45.2 L+₹1.7 L (3.83%)Rejected-AOC | L2 | Rejected-AOC NOT LOWEST AND NOT REASONABLE | |
| 3 | L3₹45.9 L+₹2.3 L (5.32%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST AND NOT REASONABLE | |
| 4 | L4₹46.0 L+₹2.5 L (5.65%)Rejected-AOC Q 49 NEAR DEOGHAR COLLEGE MAIN GATE PO PS DEOGHAR JH 814112 | DEOGHAR | DEOGHAR | JHARKHAND | 814112 | L4 | Rejected-AOC NOT LOWEST AND NOT REASONABLE | |
| 5 | L5₹46.1 L+₹2.5 L (5.70%)Rejected-AOC | L5 | Rejected-AOC NOT LOWEST AND NOT REASONABLE |
Tender Value
₹43.1 L
EMD Value
₹86,240
Closing Date
25 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GE RAMGARH CANTT
PROVN OF OFFICE BLDG FOR AGNIVEER CELL OF SRC RAMGARH CANTT
2024_MES_671500_1
8300/3240/E8
Open Tender
Civil Works
Item Rate
180 days
RAMGARH CANTT
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE RAMGARH CANTT
₹86,240
Yes
11 Nov 2024
4 Sept 2024
30 Sept 2024
4 Sept 2024
25 Sept 2024
18 Sept 2024
Amount
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed.
Excavation in over areas, not exceeding 1.5m deep & getting out in soft / loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out in soft / loose soil including forming bottom surface to required slope /gradient for laying cables /pipes ,foundations, laying of cable,shafts, well,cesspits, manholes etc. complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering & well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
Spreading & levelling in layers not exceeding 25 cm thick & well ramming including watering as required complete all as specified and directed.
Removing excavated soil not exceeding 50m & depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for plain cement concrete 1:4:8 ,type D-2 (using 40 mm graded crushed stone aggregate) as in foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and directed.
M&L reinforced cement concrete M-25 (design mix)(using 20 mm graded crushed stone aggregate) as in foundation including rafts, footings,plinth beams, and mass concrete etc.complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ
M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in lintels beam, floor/roof Beams, cantilevers, bressummers, etc complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
M&L reinforced cement concrete M-25 (design mix)(using 20 mm graded crushed stone aggregate) as in columns, pillars, piers,popst and struts etc.complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
M&L for Brick work with using fly ash bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 etc complete all as specified & directed.
M& L for Brick work with fly ash bricks straight or curved on plan to any radiusin half brick thick wall built in cement mortar 1:3, complete all as specified and directed
M & L for 40 mm thick damp proof course(DPC) PCC (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate )to horizontal or verticle surface,mixed with integral water proofing compound (as per manufacturer’s instructions) or @ 3% by weight of cement)conforming to IS: 2645 including covered with 100 micron thick polythene film complete all as specified & directed. (Note:Water proofing compound shall be measured and paid seprerately under respective item of "BoQ")
Use & waste of form work to sides of concrete foundation, base of column ,rafts,footings, plinth beams, and plinth beam and similar work for rough finished flat surfaces of concrete complete all as specified and directed.
Use and waste of form work to sides of soffit of suspended slab such as roof slab ,floor slab ,landing and similar work , not exceeding 200 mm thick for rough finished surface of concrete complete all as specified and directed.
Use and waste of form work sides & soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors & beams, etc. rough finished surfaces of concrete flat complete all as specified and directed.
Use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor & roofs and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide rough finished surface of concrete complete all as specified and directed.
Use and waste of form work to sides of columns, pillars, piers, post and struts for rough finished surface of concrete complete all as specified and directed.
S&F aluminium, anodised, barrel tower bolts 150mm long of extruded section complete all as specified and directed.
S&F 100mm size butt hinges,medium weight, cold rolled mild steel complete all as specified and directed.
S&F aluminium handles 150mm size, cast type, anodised complete all as specified and directed.
M&L for framed work such as grills,gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railing; framework of water tanks and similar work conforming to Fe 290- Gde E -165 complete all as specified and as directed
M&L for mild steel TMT bars 10mm dia and over grade Fe-500, cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed.
M&L for mild steel TMT bars 08 mm dia and over grade Fe -500 , as in stirrups, spacers & binders ,cut to length, bent to shape required, including cranking bending spirally for hooping for coloumn,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed.
M&L for 100 mm thick plain cement concrete 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub base of flooring & mass concrete etc complete all as specified and directed.
M & L for 75 mm thick plain cement concrete (1:3:6) mix, type C-1 (using 20mm graded crushed stone aggregate ) as in plinth protection, finishing the surfaces even and fair without using extra cement, including 10 mm wide, 75mm deep joints made at 3.00 m in length and filled with bitumen 85/25 grade and sand in the ratio 1:3 including necessary form work , complete all as specified and directed.
M&L for hard core of broken stone or boulder gauge not exceeding 63mm deposited, spread & leveled in layers not exceeding 15cm thick, watered and rammed to a true surface etc complete all as specified& directed.
S&F Vetrified Ceramic tiles (light shade ) 10mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed in cement mortar (1:6) complete all as specified and directed.
M&L for 10mm thick rendering (internal) on brick or concrete surface in cement mortar 1:6, finishing surface even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering (external) on stone masonry surfaces or on other than fair face of brick work or concrete surface in cement mortar 1:4, finishing surface even and smooth without using extra cement complete all as specified and directed.
M&L for 5mm thick cement plastering in cement mortar 1:3 on concrete ceiling surfaces finished even & smooth without using extra cement omplete all as specifed and as directed.
M&L for prepatation of new plaster ceiling surface and applying two coats of distemper oil emulsion (OBD) over a coat of alkali resistant primer (from same manufacturer of OBD) complete all as specified and directed.
M&L for prepatation of new plaster surface of wall surface and applying two coats of distemper oil emulsion (OBD) over a coat of alkali resistant primer (from same manufacturer of OBD) and a layer of wall care putty not less than 2mm thick complete all as specified and directed.
M & L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litr and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance Exterior paint of required shade (company depot tinted) with silicon additives @1.43 litre/10 Sqm, over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces including 1.0 mm thick plaster of paris putty applied on plastered surface even amd smooth complete all as specified & directed.
M&L for prepartion of new or previously untreated steel surface of any description , not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surface complete all as specified & directed.
M & L for application of water proofing treatment using APP modified roof membrane over non accessible/ non approachable RCC roof slab / chajjah / canopy / parapet wall( horizontal/vertical surface) to be executed through approved applicator of the membrane manufacturer/authorized applicator of the manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly and M&L for 10mm thick rendering in CM 1:4 mixed with water proofing compound@200ml per 50 kg of cement bag (Note: WPC as supply only measure and paid seprately under respective item of BOQ). (b) Applying approved bituminous based primer( conforming to IS: 3384-1995) @ 0.30 litre / Sqm manufactured by the same agency as that of APP membrane with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface . (c) Laying not less than 3mm thick APP (Atactic polypropylene Polymer modified prefabricated membrane) modified water proofing membrane weighing not less than 3.00 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Physical property of membrane shall be as under :- (i) Membrane weight not less than 3.00 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gsm/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650 Kg / Sqcm and transverse not less than 450 Kg /Sq.cm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. (e) Applying two coat of bituminious based Aluminium Paint @ 0.3 Kg /sqm over APP Membrane. Complete all as specified and directed.
Supply only water proofing compound (liquid),ISI marked complete all as specified and directed.
S& F for Galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples windows complete all as specified and directed.
S & F for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z- sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Chief
S & F for Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z -sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Chief.
S&F 3.0 mm thick sheet glass ordinary quality in squares/ rectangular not exceeding 0.5 Sqm in each pane glazing with oil putty or aluminium frame/shutters with rubber neoprene beading complete etc all as specified & directed.
S&F 3.0 mm thick sheet glass ordinary quality in squares/ rectangular exceeding 0.5 Sqm in each pane glazing with oil putty or aluminium frame/shutters with rubber neoprene beading complete etc all as specified & directed.
M & L plain cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in benching, & surface channel drains, etc., complete all as specified.
M&L for plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in kerb /benching /copings /leveliing course/window cill etc. including weathering, slightly rounded or chamfered angle and throating including use & waste of necessary form work etc complete all as specified and directed
Extra for forming fair finished channel or drain 30 cm inner girth in cement concrete using extra cement including modular mitered stoped ends etc. complete all as specified and directed.
S & F solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tubes suppyling & fixing in opening as per specification & drawing complete all as spcefied and directed by Engineer-in-Charge.
S & F for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of mild steel tube for top and bottom rails. mild steel framed shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the mild steel framed welded/sealed to stiles & rails with suitable PVC sheet beading & joined together with solvent cement complete all as fixing in the frame at site as per specification and drawing complete all as specified and as directed.
M & L glazed ceramic coloured tiles of size 350 mm x 250 mm x7mm thick / 450 mm x 350 mm x7mm thick ,as in vertical surface such as dado/skirting etc ,set and jointed in neat cement slurry and pointed in colour cement to match the tiles, over & including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M & L joint free non skid coloured ceramic tiles 7 to 8 mm thick (sqaure/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc., over and including 15mm thick screed bed in cement mortar (1:6) set and jointed in neat cement slurry and pointed in coloured cement to match the existing surfaces, complete all as specified and directed.
S&F 3.0 mm thick figured glass pin headed type in squares/ rectangular not exceeding 0.5 Sqm in each pane glazing with oil putty or aluminium frame/shutters with rubber neoprene beading complete etc all as specified & directed.
S&F for GI water tubing medium grade, ISI marked, galvanised, 15 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including cutting chases for brick walls and making good the surface in cement mortar 1:3 complete all as specified & directed.
S&F for GI water tubing medium grade, ISI marked, galvanised, 20 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including cutting chases for brick walls and making good the surface in cement mortar 1:3 complete all as specified & directed.
S&F for GI water tubing medium grade, ISI marked, galvanised, 25 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including cutting chases for brick walls and making good the surface in cement mortar 1:3 complete all as specified & directed.
S&F rotational moulded polythene water storage tank of capacity 1000 ltrs (Cylindrical/vertical with closed type), triple layer construction, ISI marked, hoisted and fixed in position including 20 mm bore GI nipple and 25 mm bore ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 455 gms) complete all as specified and directed.
S&F 15mm bore long body (weight not less than 400 gm) bib tap, cast copper alloy, CP fancy type with crutch or butterfly handle, screw down, screwed for iron pipe or for brass ferrule including flange complete all as specified and directed
S&F 15mm dia bore angle stop valve cast copper alloy fancy type, chromium plated with long shank and cup (concealed type) screwed down high pressure with crutch or butterfly handle screwed bot ends for iron pipe or for unions complete all as specified and directed
S & F pillar taps chromium plated, cast copper alloy with capstan head, screwed down with or without lettered 'Hot' or 'Cold' with long screw shanks and fly nuts, screwed for iron pipe and fixed for 15 mm bore complete all as specified & directed
S&F Stop valves 20 mm bore, cast copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions complete all as specified & directed
S&F Stop valves 25 mm bore, cast copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions complete all as specified & directed
S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S & F 110 mm bore PVC(SWR) pipes single socketed, in any length with rubber ring joints, fixed on wall including PVC clamp properly with PCC 1:2:4 complete all as specified and directed
S&F PVC (SWR) bends any radius 75mm dia complete all as specified and directed.
S&F PVC (SWR) bends any radius 110mm dia complete all as specified and directed.
S&F PVC (SWR), junction single, (Single T) equal or unequal 110mm dia complete all as specified and directed.
S&F PVC (SWR) vent cowl 110mm dia complete all as specified and directed.
M&L PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement with CP Grating with or without hole complete all as specified and directed.
S&F vitreous China wash down water closet (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe), fixing seat cover including connection to drain (or outgoing pipe, and to flushing pipe & antisyphonage pipe etc with aluminium hinging device complete all as specified and directed. Note : Plastic seat cover shall be measured separately as Supply only as considered under respective items.
Supply only plastic water closet seat closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device complete all as specified and directed.
S&F vitreous China urinals, full stall type (back or corner wall type) complete,with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe)(back or corner wall type),complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets,flush pipe, grating and Union for discharge pipe etc.complete all as specified and as directed
S & F Toilet paper holder, vitreous China,box type fixed to wall with chromium plated brass screw complete all as specified and directed.
S & F PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including ball valve float and handle, PVC flush pipe 32 mm bore & PVC connection 15 mm bore 450 mm long with PTMT nuts and brackets complete set & making good disturbed surface with CM 1:3 complete all as specified and directed.
S & F vitreous China wash basin, any colour, flat back size 550 mm X 400mm including 32mm brass chromium plated waste coupling ,PVC 32 mm bore waste pipe, chromium plated Grating including bracket complete all as specified and directed.
M&Lprecast reinforced cement concrete 1:2:4 ,type B-1 (using 20 mm graded crushed stone aggregate) as in kitchen platform, shelves, cover slab (man holes), chajjas,etcand similar articles with plain faces including necessary formwork complete all as specified and directed. Note : Reinforcement will be measured & paid seperately under respective item of BOQ.
S & F Reinforced concrete drain pipes of 150mm dia class NP-3 laid and jointed with collars in trenches and jointed, complete all as specified and as directed by Engr-in-Charge
M & L, for Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid in PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) including necessary shuttering and tested complete for 150mm bore pipe all as specified and directed.
M&L for Construction of Soakage well for 3.00 dia( internal dia ) & 3.0 m (effective depth) including necessary excavation in earth work in any type of soil , plain cement concrete 1:3:6 type C-2 ( using 40 mm graded crushed stone aggregate ) as in foundation , brick work in cement mortar 1:4 in walls & honey combed brick wall , reinforced cement concrete M-25 ( design mix) as in slab cover including pre-cast cover slab having 8 mm dia TMT bar reinforced,plain cement concrete band and dwarf wall, form work to sides and soffits of RCC slab & filling with brick bats loose filling including interconnecting pipes of RCC /DWC complete all as specified and shown in drawing No. TD- CEJZ/TD/58 of 1/1 dt 05 May 2020 Sheet No.complete all as specified.
M&L for Conventional type of Septic Tank for 50users including necessary earth work in excavation in any type of soil, plain cement concrete 1:2:4 type B-2 ( using 40 mm graded crushed stone aggregate ) as in foundation , brick work in cement mortar 1:4 , ,reinforced cement concrete M-25 ( design mix) as in slab cover including pre-cast man hole cover slab having 8 mm dia TMT bar reinforcement @ 75 mm c/c & 6 mm thick mild steel plate embedded all around of cover slab , 15 mm thick plaster in cement sand mortar in 1:4 on wall, vent shaft, sludge chamber , form work to sides and soffits, 150 mm dia SGSW inlet & out let pipes up to 3 m from outer face of wall, CI vent pipe, sludge chamber, RCC baffle wall, returning filling & removal etc, complete all as shown on drawing No.TD CEJZ/TD/57/2000 , Sheet No.1/1 as specified.
M&L for 60 mm thick factory made machine pressed pre-cast concrete coloured interlocking paver block of approved shade, laid in design & pattern as in footpath, light traffic parking etc, made by table vibratory method using PU mould of any shape and size conforming to IS-15658-2006 of M-35 grade laid over & including 50mm thick compacted bed over fine sand, compacting and proper embedding/ laying by vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
M&L for point wiring for following point using approved colour coding as per IS controlled by one way switch with using with FRLSH PVC insulated PVC unsheathed electric cable conforming to IS:694, 1100V grade AC, two core having multi stranded copper conductor of size 1.5 Sq.mm nominal cross sectional area for phase & neutral and including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed of white/Ivory colour wiring system & 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly covered with modular white cover plate with inner frame suitable for modular switches for housing/fixing switches etc., including cutting chases and making wood disturbed surface to match with existing finishes complete all as specified and directed. Note: Proper colour coding to be adopted:-
(a) One light point controlled by one one way switch
(b) One fan/exhaust fan point controlled by one one way switch.
(c) One 3/5 pin socket outlet 5 Amp on the same board with other swithes.
(d) One 3/5 pin 5 Amps socket outlet on indepandant board.
S&F modular switch piano flush type single pole one way 6 Amps, one module complete all as specified and directed.
S&F modular socket 6 Amps,2/3 pin combined two module, complete all as specified and directed.
Supply and fix ceiling rose three terminals PVC/ Polycarbonate, isolated body complete all as specified.
S&F stepped type modular fan regulator 230 V,120 watt ,1/2 module complete all as specified and directed.
Ditto all as per item No 83 here-in-before with 2.5 Sqmm (Nominal area) FRLSH cable PVC for 15 Amp 3/5 pin socket power point including 2.5 Sq mm copper conductor for earth coutinuity all as specified and directed.
S&F modular switch piano flush type single pole one way 16 Amps, one module complete all as specified and directed.
S&F modular socket 16 Amps,2/3 pin combined two module, complete all as specified and directed.
S & F lamp holder, PVC/Polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings (ISI marked), complete all as specified.
S&F 12 watt LED bulb PAG series B-22 base complete all as specified and directed.
S&F Inveter LED bulb of capacity 12 watts lumen out put (1200) length 140 mm width 70 mm base cap B22 ,3 star, (ISI marked) complete with all accessories base (ISI marked) all as specified & directed by Engr-in-Charge.
S & F for LED batten fitting 1x20 watt, 220 volt surface mounting including connection up with 2 core flexible copper conductor cable of size with flexible pipe from ceiling rose to fitting of any size complete all as specified and directed.
S & F for LED batten fitting 2Ft x 10 watt, mirror type, 220 volt, AC surface mounting including connecting up with 2 core flexible copper conductor cable of suitable size with flexible pipe of any size complete all as specified and directed.
S&F LED light fitting 1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S & F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
S & F for exhaust fan electric single phase, AC 230 Volts, 50 hz, plastic body, 250mm sweep, 1200RPM with louvers, copper winding and connecting with flexible PVC insulated multi stranded copper conductor wire of required size from ceiling rose including cutting of wall and finishing of plaster complete all as specified and directed.
S & F building security lights with new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP65 roadway luminaries with high power LEDs as light source & exclusively designed polycarbonate cover along with electronic driver type street light fitting 35 watt capacity LED and including all accessories duly pre-wired, fixing on bracket with nut, bolts & washers as required at site for fixing of street light on wall complete all as specified and directed.
S&F bracket made of GI pipe light grade 1.2 Mtr long of size 40 mm bore, bend to shape as per site requirement fixed to pole/wall with flat iron clamp size 40 x 5 mm -02Nos with suitable bolts, Nuts, washers etc including two coats of synthetic enamel aluminium paint over a coat of red oxide primer on exposed surface of mild steel surface complete all as specified and directed.
S&F sheet matel enclosures for DBs, triple pole and neutral 4 way double door with suitable with AMP rated bus bar, 415 Volts suitable to accommodate MCB and necessary electric cable through suitable lugs by crimping and making good disturbed areas of wall complete all as specified and directed.
M&L for MCB single pole,6 to 32 Amp 240 volt "C" curve 10 KA, transparent lebel holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed .
S&F 415V, 10 KA 'C' curve miniature circuit breaker (MCB) of triple pole and neutral (TPN) and current carrying capacity 40 to 100 AMP in the DB with connection testing and commissioning complete all as specified and directed.
M&L ,for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts check nuts & washers of galvanised iron or steel, protected by GI pipe 15 mm bore (light grade) and watering pipe 20 mm bore GI pipe (light grade) and PCC of chamber and coping shall in 1:3:6 type C-1 using 20 mm graded stone aggregate including excavation and earth work and removal of surplus soil and filling with black cotton soil upto ground level complete all as shown in electrical plate No 3 of SSR Pt-I, 2009 with CI cover 10mm thick of size 300x300mm with charcoal dust and common salt complete and earth lead connected to panel including testing complete all as specified and directed. Note : Earth test result should not less than one ohm.
Supply,fixing & laying for GI water tubing medium grade, ISI marked, galvanised, 20 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) with both end threaded in any length including cutting threading connection in new or old position socket laid in trenches and ceiling or laid in floors complete all as specified & directed.
Supply,fixing & laying for GI water tubing medium grade, ISI marked, galvanised, 25 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) with both end threaded in any length including cutting threading connection in new or old position socket laid in trenches and ceiling or laid in floors complete all as specified & directed.
S & F gun metal globe or gate valve of 20 mm dia with iron wheel head screwed both ends ISI marked fixed to GI pipe complete all as specified and as directed.
S & F gun metal globe or gate valve of 25mm dia with iron wheel head screwed both ends ISI marked fixed to GI pipe complete all as specified and as directed.
Supply and spreading clean, dry, fine river sand for under ground electric cable in two layers (8cm thick before laying of cable & 15cm thick after laying cable to a total of 23cm) including gentle punning the sand upto 18cm (total thickness) and consolidated around cable for protection of UG cable complete all as specified and directed. NOTE:- For measurement purpose punned thickness shall be considered as per clause 19.75 of SSR Part-I.
Supplying & Laying factory made un-reinforced pre-cast flat concrete cable protection cover of class LV , type- I, size 250 mm x 150mm x 40mm, complete all as specified and directed by the Engineer-in-Charge.
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 16 Sqmm 4.0 core complete all as specified and directed.
S & F for 40 mm bore GI tube, light grade with all fitting for cable protection including clamp ,nut,bolts & washer etc complete all as specified and as directed.
Boring of hole under road, pavement, hard standing without disturbing existing surface by trenchless technology using hand drilled (manual boring) technique and necessary required tools complete all as specified and directed by Engineer-in-Charge. Note : Pipes shall be laid minimum 1.00 mtr below/under existing road surfaces/taxi track / apron /floors etc.complete all as specified and as directed.
M/s friend enterprises (BID ID -3105589)
M/S Kunwar Construction (BID ID -3100479)
simplex infra project (BID ID -3103070)
M/S PARAS NATH SINGH (BID ID -3101244)
M/s Ray construction (BID ID -3107241)
M/S SHAMBHU SHARAN SINGH (BID ID -3106793)
M/S tiwari enterprises (BID ID -3101140)
upadhyay engineers and consultant (BID ID -3106667)
JP ENTERPRISES (BID ID -3110799)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .