Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 LAccepted-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | ₹33.5 L Quoted ₹35.7 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹39.0 L+₹3.3 L (9.33%)Rejected-AOC FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹39.0 L+₹3.3 L (9.33%) | L2 | Rejected-AOC R |
| 3 | L3₹44.0 L+₹8.3 L (23.2%)Rejected-AOC | ₹44.0 L+₹8.3 L (23.2%) | L3 | Rejected-AOC R |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
23 Mar 2021, 6:00 pmClosed
GE IMA DEHRADUN
GE IMA DEHRADUN
REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION INCLUDING REPLACEMENT OF OLD UNSERVICEABLE SWITCH SOCKETS LIGHT FITTING AND CONNECTED ACCESSORIES MAINT OF SUMMER APPLIANCES AT ACC BLDG PH I TAB BLDG AT IMA DEHRADUN
2021_MES_413632_2
GE/IMA/87/2020-21 9036/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
GE IMA DEHRADUN
Refer NIT
8 documents required · 8 mandatory
₹500
Yes
GE IMA DEHRADUN
₹90,000
Yes
8 Apr 2021
23 Feb 2021
25 Mar 2021
24 Feb 2021
23 Mar 2021
10 Mar 2021
Amount
Taking down carefully existing aluminum/copper surface/concealed point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces in CM 1:3 of walls, floors, ceiling etc including distempering to match with existing surfaces complete all as specified and directed. Note:- Roof/ceiling height of Tab blgg up to 15 mtr. where U/S point wiring/fitting fixture to be taking out.
Point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLS having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area drawn in and including PVC conduit concealed and 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor cable FRLS as continuous earth conductor, connected to earth dolly by providing suitable lugs with inner and outer frame plate matching with surrounding with sunken steel boxes zinc oxide plated of suitable size for mounting modular switches, sockets etc complete for the following:- Note:- (i) Point wiring & earth wire shall be connected to each & every sunken box. (ii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates. (iii) Modular cover plate with frame and sunken steel boxes zinc oxide plated as per site requirements shall be included in quoted rates.
One light point controlled by one, one way Modular switch 6 Amps
One fan/exuast fan point controlled by one, one way Modular switch 6 Amps
One 5 pin 5 Amps switch socket outlet point controlled by one Modular switch on independent boad.
One 5 pin 5 Amps switch socket outlet point controlled by one modular switch on the same board.
One bell point controlled by one, one way modular switch 5 / 6 Amp.
Description all as per item No 2 here in before but point wiring with 2.5 sqmm multistrand copper conductor cable for one five pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm PVC insulated multi strand copper conductor cable as continous earth wire.
Point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLS having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area drawn in and including surface PVC casing & caping with all fitting and fixing accessories and 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor cable FRLS as continuous earth conductor, connected to earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxes 1.6mm thick, 60mm deep of required size factory made for mounting switch, regulators etc with and including 3mm thick plastic hylam laminated sheet cover (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint inside for mounting switches, sockets etc complete for the following:- Note:- (i) The quoted rates shall be deemed to be inclusive for fixing the casings to surface with using PVC rawl plugs etc. (ii) Point wiring & earth wire shall be connected to each & every sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.
One light point controlled by one, one way 6 Amp switch.
One fan/exhaust fan point controlled by one, one way 6 Amp switch.
One 5 pin 5/6 Amps socket outlet point on the same board with other switch .
One 5 pin 5/6 Amps socket outlet point on independent board controlled by one, one way switch.
One bell point controlled by one, one way 6 Amp button switch.
Description all as per item No 4 here in before but point wiring with 2.5 sqmm multistrand copper conductor cable for five pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm PVC insulated multi strand copper conductor cable as continous earth wire.
Point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLS having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area drawn in existing conduit concealed/ surface/casing & caping and 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor cable FRLS as continuous earth conductor, connected to earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxes 1.6mm thick, 60mm deep of required size factory made for mounting switch, regulators etc with and including 3mm thick plastic hylam laminated sheet cover (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint inside for mounting switches, sockets etc complete for the following:- (ii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates.
One light point controlled by one, one way 6 Amp switchs.
One fan/exhaust fan point controlled by one, one way 6 Amp switch.
One 5 pin 5/6 Amps socket outlet point on the same board with other switch.
One 5 pin 5/6 Amps socket outlet point on independent board controlled by one, one way switch.
One bell point controlled by one, one way 6 Amp button switch.
Description all as per item No 6 here in before but point wiring with 2.5 sqmm multistrand copper conductor cable for one five pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm PVC insulated multi strand copper conductor cable as continous earth wire.
Switch piano, flush type, single pole one way, 5 Amp complete all specified and as directed
Switch piano, flush type, single pole one way, 15 Amp complete all specified and as directed
Socket outlet, multipurpose, 2 in 1, 5 pin, 5 Amp complete all specified and as directed
Socket outlet, multipurpose, 2 in 1, 5 pin, 15 Amp complete all specified and as directed
Bell push flush type, 5 Amps complete all specified and as directed
Electronic step rotary type fan regulator 100W, 230 volts AC 50Hz complete all as specified and directed
Modular switch single pole one way 6 Amp complete all specified and as directed
Modular switch single pole one way 16 Amp complete all specified and as directed
Modular socket outlet 2/3 pin combined 6 Amp 240 volts complete all specified and as directed
Modular socket outlet 2/3 pin combined 16 Amp 240 volts complete all specified and as directed
Modular bell push flush type 5 Amps complete all specified and as directed
Fan regulator modular step type 120W 240 volts 2 module type complete all as specified and directed
Switch piano, flush type, single pole one way 5 Amp fixed in repair complete all as specified and directed
Switch piano, flush type, single pole one way 15 Amp fixed in repair complete all as specified and directed
Socket out let, multipurpose, 2 in 1 5 pin, 5 Amp fixed in repair complete all as specified and directed
Socket out let, multipurpose, 2 in 1 5 pin, 15 Amp fixed in repair complete all as specified and directed
Batten holder PVC/polycarbonate type with back plate suitable for batten fitting fixed in repairs complete all as specified and directed
Modular switch single pole one way 6 amp fixed in repair complete all as specified and directed
Modular switch single pole one way 16 amp fixed in repair complete all as specified and directed
Modular socket outlet 2/3 pin combined 6 amp 240 volts fixed in repair complete all as specified and directed
Modular socket outlet 2/3 pin combined 16 amp 240 volts fixed in repair complete all as specified and directed
Modular bell push flush type 5 amp fixed in repair complete all as specified and directed
Fan regulator modular step type 120W 240 volts 2 module type fixed in repair complete all as specified and directed
Ceiling rose, 63.5 mm dia, ISI marked, three terminal of polycarbonate /isolated body complete all specified and as directed.
MCB SP 6 to 32Amps, 240 volts 'C' Curve 10 KA, including connection with suitable size copper lugs complete all as specified and directed
MCB SPN 40 to 63 Amps, 240 volts 'C' Curve 10 KA, including connection with suitable size copper lugs complete fixed in repair all as directed.
MCB TPN 40 to 63 Amps, 415 volts 'C' Curve 10 KA, including connection with suitable size copper lugs complete fixed in repair all as directed.
Sheet metal enclosure, single pole and neutral with three pin and earth plug and socket with and including one single pole MCB 20 Amps, 240 volts,10 KA complete fixed in repair all as directed.
Sheet metal enclosure, triple pole and neutral with three pin and earth plug and socket with and including one four pole MCB 63 Amps, 415 volts,10 KA complete fixed in repair all as directed.
Bakelite sheet cover 3 mm thick cut to required shape and size including brass screws and cup washer of following size for mounting switch, socket fan regulator etc including taking down existing unserviceable bakelite sheet cover complete all as specified and directed
Sub main wiring with two single core PVC insulated unsheathed FRLS cable 1100 Volt grade, 10 Sqmm size with multi stranded copper conductor drawing into and including 20mm dia rigid PVC conduit in surface/concealed as required including one run single core PVC insulated unsheathed 10 Sqmm FRLS cable with multi stranded copper conductor as a earth continuity and connected upto DB including taking down old unserviceable submain wiring etc complete all specified and as directed. NOTE: (i) Two run of single core PVC cable with one run of earth conductor & condiut shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface/concealed with using PVC rawl plugs etc.
Sub main wiring with two single core PVC insulated unsheathed FRLS cable 1100 Volt grade, 6 Sqmm size with multi stranded copper conductor drawing into and including 20mm dia rigid PVC conduit in surface/concealed as required including one run single core PVC insulated unsheathed 6 Sqmm FRLS cable with multi stranded copper conductor as a earth continuity and connected upto DB including taking down old unserviceable submain wiring etc complete all specified and as directed. NOTE: (i) Two run of single core PVC cable with one run of earth conductor & condiut shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface/concealed with using PVC rawl plugs etc.
Sub main wiring with two single core PVC insulated unsheathed FRLS cable 1100 Volt grade, 4 Sqmm size with multi stranded copper conductor drawing into and including 20mm dia rigid PVC conduit in surface/concealed as required including one run single core PVC insulated unsheathed 4 Sqmm FRLS cable with multi stranded copper conductor as a earth continuity and connected upto DB including taking down old unserviceable submain wiring etc complete all specified and as directed. NOTE: (i) Two run of single core PVC cable with one run of earth conductor & condiut shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface/concealed with using PVC rawl plugs etc.
Sub main wiring with two single core PVC insulated unsheathed FRLS cable 1100 Volt grade, 2.5 Sqmm size with multi stranded copper conductor drawing into and including 20mm dia rigid PVC conduit in surface/concealed as required including one run single core PVC insulated unsheathed 2.5 Sqmm FRLS cable with multi stranded copper conductor as a earth continuity and connected upto DB including taking down old unserviceable submain wiring etc complete all specified and as directed. NOTE: (i) Two run of single core PVC cable with one run of earth conductor & condiut shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface/concealed with using PVC rawl plugs etc.
Sub main wiring with two single core PVC insulated unsheathed FRLS cable 1100 Volt grade, 10 Sqmm size with multi stranded copper conductor drawing into existing conduit as required including one run single core PVC insulated unsheathed 10 Sqmm FRLS cable with multi stranded copper conductor as a earth continuity and connected upto DB including taking down old unserviceable submain wiring etc complete all specified and as directed. NOTE: (i) Two run of single core PVC cable with one run of earth conductor shall be measured as one unit.
Sub main wiring with two single core PVC insulated unsheathed FRLS cable 1100 Volt grade, 6 Sqmm size with multi stranded copper conductor drawing into existing conduit as required including one run single core PVC insulated unsheathed 6 Sqmm FRLS cable with multi stranded copper conductor as a earth continuity and connected upto DB including taking down old unserviceable submain wiring etc complete all specified and as directed. NOTE: (i) Two run of single core PVC cable with one run of earth conductor shall be measured as one unit.
Sub main wiring with two single core PVC insulated unsheathed FRLS cable 1100 Volt grade, 4 Sqmm size with multi stranded copper conductor drawing into existing conduit as required including one run single core PVC insulated unsheathed 4 Sqmm FRLS cable with multi stranded copper conductor as a earth continuity and connected upto DB including taking down old unserviceable submain wiring etc complete all specified and as directed. NOTE: (i) Two run of single core PVC cable with one run of earth conductor shall be measured as one unit.
Sub main wiring with two single core PVC insulated unsheathed FRLS cable 1100 Volt grade, 2.5 Sqmm size with multi stranded copper conductor drawing into existing conduit as required including one run single core PVC insulated unsheathed 2.5 Sqmm FRLS cable with multi stranded copper conductor as a earth continuity and connected upto DB including taking down old unserviceable submain wiring etc complete all specified and as directed. NOTE: (i) Two run of single core PVC cable with one run of earth conductor shall be measured as one unit.
Circuit/submain wiring with single core FRLS PVC insulated copper stranded conductor cable drawing into existing PVC rigid conduit surface /concealed/ casing caping as required of following sizes, including taking down unserviceable existing wiring etc complete of following sizes as directed.
Surface mounted decorative oval bulk head edge-lit LED luminare comprising and including 10 watt high brightness LED's and connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to walls including taking down existing fitting all as specified and directed. Make:- Crompton Cat Part No-LBHP-10-CDL or equivalent to Philips/ Havells.
Suspended architectural LED luminaire along with suspension kit & integral electronic driver provides soft light and glare free symmetrical illumination (with continuous mounting end cap) with and including 40 W LED tube rod and all accessories and fixing arrangement for fixing the light fitting including taking down existing fitting complete all as specified and directed. Make: Havells Cat part No. CONSTA1144LP40WLED840SPMMAWH or equivalent to Philips/Wipro
Aesthetically designed, 1'x1' cool white flat panel for surface mounting which provide soft-light and glare free symmetrical illumination of fixture size 300x300x70 mm with and including 15 W LED complete, integrated electronic driver and connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to ceiling including taking down existing fitting complete all as specified and directed. Make: Havells Cat part No. PLUTOSURFACE1X1PLS15WLED857S or equivalent to Philips/Wipro
Aesthetically designed, 2' x 2' cool white flat panel for suitable for surface mounting which provide soft-light and glare free symmetrical illumination of fixture size 600x600x70 mm with and including 42 W LED complete, integrated electronic driver complete and connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to ceiling including taking down existing fitting complete all as specified and directed. Make:- Havells cat Part No-PLUTOSURFACE2X2PLS42WLED857S or equivalent Philips/Wipro
Aesthetically designed, LED 4'x1' cool white flat panel suitable for surface mounting which provide soft-light and glare free symmetrical illumination of fixture size 1200x300x70 mm with and including 42W LED complete and connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to ceiling including taking down existing fitting all as directed. Make:- Havells Cat Part No-PLUTOSURFACE4X1PLS42WLED857S or equivalent Philips/Wipro.
Aesthetically designed, 2' x 2' cool white flat panel for suitable for armstrong/grid ceiling which provide soft-light and glare free symmetrical illumination of fixture size 595x595x70 mm with and including 42 W LED complete, integrated electronic driver complete and connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to ceiling including taking down existing fitting complete all as specified and directed. Make:- Havells Cat Part No-PLUTONEO2X2PLR42WLED857S or equivalent to Philips/Wipro
LED ball lamp 15 W suitable for Angle/ pendant holder fittings complete all as specified and directed. Make:-Havells Cat part No-LED ADORE 15W E27 CDL 3 STAR BALL LAMP or equivalent to Philips/Wipro.
Disconnecting and taking out the existing Air conditioner Split type of any description any capacity, any make and in any position, both indoor and outdoor unit single/three phase, strip opening , cleaning and servicing of the AC with using caustic soda/detergent solution, cleaning of suction air filter and coil of indoor unit and brazing the discharge and suction line, reassembling, fixing and testing of the AC complete all as specified and directed by Engineer-in-Charge. Note:- (i) The servicing of one split AC (one indoor unit + one outdoor unit) will be measured as one job. (ii) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item (ii) Any minor complaints such as lekage of water, abnormal noise and any electric loose connection etc raised by user after carrying out servicing shall be rectified by the contractor without any extra cost to the Govt.(iii) The rate quoted for servicing shall be inclusive of attending complaints and keeping the AC in working condition during the entire contract period and further for defects liability period.
Checking of leakage of refrigerant system of split type AC of capacity 1.5 /2.0/3.0 ton by putting the nitrogen pressure , identifying the leaks / defects ,repairing the same by brazing and testing and vacuumising the system and supply and filling of oil in required quantity complete all as specified and directed . Note :- Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if required, is deemed to be included under the unit rate quoted by the contractor for this item
Supply & charging of refrigerant Gas R-22 Mono chloro difluoro methane (CHCLF2) to make up the required pressure complete all as specified and directed by Engineer-in-Charge.
Supply only single pole, 25Amp contactor suitable for split AC 1.5/2 TR capacity complete all as directed by Engineer-in-charge.
Supply only mild steel angle iron stand factory made suitable for out door unit for 1.5/2 TR split AC complete all as directed by Engineer-in-charge.Make shape & size as per existing :-As Per Sample
Supply only remote for senser kit suitable for 1.5/2 TR capacity Split type AC of make Voltas, LG, Carrier AC's complete all as directed by Engineer-in-charge.Make :-As Per Sample
Supply only blower fan motor single phase 220/230 volts 1400 RPM suitable for 1.5TR/2TR Split type AC complete all as directed.
Supply only blower fan motor three phase 415 volts 1400 RPM suitable for 3 phase,3TR Split type AC complete all as directed.
Supply only PCB plate complete with connections suitable for Split type AC 1.5TR/2TR single phase capacity complete all as specified and directed by Engineer-in-Charge .
Supply only PCB plate complete with connections suitable for three phase Split type AC 3TR capacity complete all as specified and directed by Engineer-in-Charge.
Supply only starting capacitor 80-100 mfd suitable for 1.5/2 TR capacity Window/split type AC complete all as directed.
Supply only starting capacitor of capacity 100-120 mfd complete all as directed.
Supply only condensor fan blade set for window / Split type AC 1.5 / 2 Ton capacity of ISI marked as approved by GE. Make:-As approved by GE.
Supply only relay box type suitable for window/ Split type AC 1.5TR/2TR capacity complete all as directed by Engineer-in charge.
Supply only relay box type suitable for three phase Split type AC 3TR capacity complete all as directed by Engineer-in charge.
Copper tubing with insulation of size 3/8" special annealed pressure copper purity min 99.9% and making flaring at both ends for connections including brass nut and testing fixed in repair complete all as directed.
Copper tubing with insulation of size 5/8" special annealed pressure copper purity min 99.9% and making flaring at both ends for connections including brass nut and testing fixed in repaircomplete all as directed.
Insulation for copper tube size 3/8 or 5/8" fixed in repair complete all as directed.
Condenser copper coil suitable for window type /split type AC 1.5 / 2 Ton capacity fixed in repair with and including charging of refrigerant gas R-22 and leakage testing complete all as directed. Make :- As approved by GE.
Condenser copper coil suitable for split type AC 3.0 Ton capacity fixed in repair with and including charging of refrigerant gas R-22 and leakage testing complete all as directed. Make :- As approved by GE
Cooling copper coil of indoor unit suitable for split type AC 1.5 / 2.0 Ton capacity fixed in repair with and including charging of refrigerant gas R-22 and leakage testing complete all as directed. Make :- As approved by GE
Cooling copper coil of indoor unit suitable for split type AC 3.0 Ton capacity fixed in repair with and including charging of refrigerant gas R-22 and leakage testing complete all as directed. Make :- As approved by GE
PVC flexible Pipe 25mm/40mm/50mm dia size over insulated copper tube 3/8” or 5/8”,with necessary packing tape 50mm wide for protection fixed in repair complete all as specified and directed by Engineer-in-Charge.
Shifting and fixing split AC cap- 1.5 / 2.0/3.0 TR including cutting for hole on wall and making good of disturbed surface with matching existing colour/ distemper complete all as directed by Engineer-in-charge.
Dismantling and taking out unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor for Split type AC 1.5 TR capacity complete including testing of nitrogen gas pressure and charging of gas R-22 upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge. Note :- Contractor shall submit Purchase voucher of firm/ dealer & test certificate of manufacturer before payment.
Dismantling and taking out unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor for Split type AC 2 TR capacity complete including testing of nitrogen gas pressure and charging of gas R-22 upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge. Note :- Contractor shall submit Purchase voucher of firm/ dealer & test certificate of manufacturer before payment.
Dismantling and taking out unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor for Split type AC 3.0 TR capacity fixed in repair complete including testing of nitrogen gas pressure and charging of gas R-22 upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge. Note :- Contractor shall submit Purchase voucher of firm/ dealer & test certificate of manufacturer before payment.
PVC insulated and sheathed cable 3 core 4.0 sqmm stranded copper conductor fixed in repair complete all as spcified and directed.
PVC insulated and sheathed cable 04 core 06 sqmm stranded copper conductor fixed in repair complete all as specified and directed.
Dismantling and taking out the non-functional Water coolers of any description, any make and in any position of capacity 40 ltr to 150 ltr, including disconnection of water line connections, cleaning and servicing of the water cooler , checking all serviceable parts, necessary brazing, reassembling all parts of water cooler, restoring water supply connections and testing of the water coolers complete as all specified and directed by Engineer–in–charge. Note :-(i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item.(ii) Any minor complaints such as lekage of water, abnormal noise and any electric loose connection etc raised by user after carrying out servicing shall be rectified by the contractor without any extra cost to the Govt.(iii) The rate quoted for servicing shall be inclusive of attending complaints and keeping the water cooler in working condition during the entire contract period and further for defects liability period.
Checking of leakage of refrigerent system of water cooler of capacity 40/80/120/150 litrs by putting the nitrogen pressure , identifying the leaks / defects ,repairing the same by brazing / welding of bottom leg suppots and testing and vaccumising the system and supply and filling of oil in required quantity complete all as specified and directed . Note :- (i) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2) is deemed to be included under the unit rate quoted by the contractor for this item (ii) The new fixed spares/ parts shall be paid as "supply only" as specified / mentioned here-in-after and fixing charges for new/ repaired items are deemed to be included under this item.
Supply only Condensor fan Motor suitable for Water cooler of capacity 40/60/80/120/150 ltr duly connected and testing complete in position all as directed. Make: GE/Crompton/ or equivalent make as approved by GE.
Supply only over load protector suitable for water cooler of capacity 40/60/ 80/ 120/150ltr complete all as directed. Make as approved by GE.
Supply only starting capacitor conforming to IS - 2193-1975 AC 230 Volts in Aluminium container capacity 40/60 Mfd complete all as specified and directed.
Supply only running capacitor 25 mfd complete all as specified and directed.
Supply only running capacitor 10 Mfd complete all as specified and directed.
Supply only starting capacitor 10 mfd complete all as directed.
Supply only thermostat switch suitable for water cooler capacity 40/60/80/120/150 ltr and any make complete all as directed and approved by GE.
Supply only starting relay complete suitable for water cooler of different capacity and any make complete all as specified and directed.
Supply only push/lifting type self closing tap of 15mm dia chromium plated suitable for Usha Sriram/Sidwal/Voltas/Bluestar make water cooler of different capacity complete all as specified and directed.
Supply only inner door gasket suitable for Usha Sriram/Sidwa/Voltas/Bluestar make water cooler of different capacity complete all as directed.
Supply only wiring kit suitable for water cooler of various capacity complete all as specified & directed.
Supply only condensor Fan blade set suitable for Water cooler of capacity 40/60/80/120/150 ltr complete all as directed.
Supply only PVC drain pipe 2m long of size 25 to 40mm dia complete with 04 Nos hose clip of suitable sizes complete all as directed .
Supply only drier filter pencil type suitable for water cooler of different capacity and any make complete all as specified and directed.
Supply only stainless steel water tray for safe drinking water suitable for Water cooler of capacity 40/60/80/120/150 ltr and any make complete all as directed.
PVC float valve 15mm dia with epoxy coated aluminium rod and high density plastic ball min weight 142 gms with Nipple & long screws etc suitable for Water cooler fixed in repair complete all as directed.
PVC connection 15 mm size 450 mm long with brass union nuts on both ends suitable for water cooler fixed in repair complete all as directed.
PVC insulated and sheathed cable 3 core 2.5 sqmm stranded copper conductor fixed in repair complete all as specified and directed.
Steel water tubing medium grade 15mm bore galvanized with all fittings and fixed to walls or through walls / ceiling or laid in floors including cutting, chasing, pining in for concealed portion fixed in repair complete all as specified and directed.
Steel water tubing medium grade 20mm bore galvanized with all fittings and fixed to walls or through walls / ceiling or laid in floors including cutting, chasing, pining in for concealed portion fixed in repair complete all as specified and directed.
Dismantling and taking out old unserviceable Gate valve/Globe valve and Supply, fixing, jointing and testing, IS-778 Marked, of approved quality, gun metal globe/gate valve with iron wheel head, both ends screwed for iron pipe 15mm bore complete all as specified and directed
Dismantling and taking out old unserviceable Gate valve/Globe valve and Supply, fixing, jointing and testing, IS-778 Marked, of approved quality, gun metal globe/gate valve with iron wheel head, both ends screwed for iron pipe 20 mm bore complete all as specified and directed
Repair to rusted and perished body and foundation base frame of water coolers any capacity, make & model including taking down all accessories, condenser, fan motor, spare parts, kit box from water cooler carefully & refixing the same after necessary repairs as required to make the water cooler functional, by providing new MS sheet matching with existing gauge after removing old rusted/ unserviciable portion including replacement of old nut bolts, screw, hinges etc and painting with two coats of synthetic enamel paint over a coat of primer of the same colour complete all as as directed
Preparation of old steel surface of water cooler of any capacity,make & model and applying one coat of synthetic enameled paint (white) by spray machine including writing MES No/ SM No in capital letters of height not less than 20 mm on water cooler body in MES pattern and style complete all as specified and directed.
Rewinding of blower motor 1/32 HP, 1/35 HP, 1/12 HP AC 240 Volts single phase 50C/S with existing guage of copper winding wire including insulation varnishing and repair of connecting bushes, bearing , blower fan blade,shaft and connection wire and testing complete of water cooler of (Make Shakti) all as specified and directed.
Dismantling and taking down unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor of Make Usha Sri Ram, Blue star, voltas for Water Cooler 40/80 ltr capacity fixed in repair complete including testing of nitrogen gas pressure and charging of gas R-134A upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge. Note :- Contractor shall submit Purchase voucher of firm/ dealer & test certificate of manufacturer before payment.
Dismantling and taking down unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor of Make Usha Sri Ram, Blue star, voltas for Water Cooler 60/120 ltr capacity fixed in repair complete including testing of nitrogen gas pressure and charging of gas R-134A upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge. Note :- Contractor shall submit Purchase voucher of firm/ dealer & test certificate of manufacturer before payment.
,Dismantling and taking down unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor of Make Usha Sri Ram, Blue star, voltas for Water Cooler 150 ltr capacity fixed in repair complete including testing of nitrogen gas pressure and charging of gas R-134A upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge. Note :- Contractor shall submit Purchase voucher of firm/ dealer & test certificate of manufacturer before payment.
Supplying and Charging of refrigerant gas (Make R-134A) including leakage testing of complete plant/equipment with nitrozen gas and repairing leakage portion complete all as directed.
Supplying and Charging of refrigerant gas (Make HFCS R-600A) including leakage testing of complete plant/equipment with nitrozen gas and repairing leakage portion complete all as directed.
Dismantling and taking out the non-functional voltage stabilizer for General servicing and minor repairs AC 230 volts Single Phase 3 to 5 KVA cap. of any make by checking, tightening of electrical connection, replacement of all missing/worn out screws, indicating lamps, checking of electronic circuits to make it functional including replacement of minor defective parts complete all as specified and directed. Note :-The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item
Supply only transformer copper wound of voltage stabilizer AC, Single Phase, 230 volts of capacity 5 KVA of approved make.
All as per Item No 117 above but of capacity 4KVA -do-
All as per Item No 117 above but of capacity 3KVA -do-
Supply only electro mechanical type voltmeter 0 to 300 volts Single Phase , AC, 65 mm square/round type for stabilizer as per requirement complete all as specified & directed.
Supply only relay 12/24 volts suitable for 3-5 KVA voltage stabilizer AC, Single Phase, 230 volts of approved make.
Supply only DC electronic circuit relay of capacity 24/12 volts stabilizer for 3-5 KVA complete of approved make all as specified & directed.
Supply only 3 way connector 230 volts 50 Hz AC, 32 Amp complete of approved make & of existing shape and size all as specified.
Supply only toggle switch 20/30 Amp two way of approved make all as specified and directed.
Supply only top plug 15 amp, 240 volts, ISI marked.
Supply only top plug 5 amp, 240 volts, ISI marked.
Taking down unserviceable storage type electric water heater (Geysers) after isolating electric supply of capacity 25/35 litres from site for desclaing the inner container with cleaning solution including refixing in same position or where directed complete all as directed.
Taking down unserviceable storage type electric water heater (Geysers) from site of capacity 25/35 ltr for necessary repair of inner tank for water leakage and including with stainless steel welding and refixing in same position or as directed and testing complete all as directed.
Stainless steel inner container (tank) of capacity 25/35 litres and testing complete of make. Pearl, Ditz, Racold, Gilco, Sahas including taking down of old unserviceable tank complete all as directed.
Non return valves cast copper alloy 15 mm dia complete including taking down old existing NRV all as directed.
Taking down old/unserviceable inlet outlet stainless steel chromium plated assembly ISI marked complete, brazing/ welding and refixing including testing of geyser 25/35 litres capacity complete all as directed.
Taking down old/unserviceable assembly of water heater of capacity 25/35 ltr & S&F new stainless steel chromium plated assembly ISI marked as per sample suitable for water heater of capacity 25/35 ltrs complete all as directed.
Heating element 2 KW 230 volt, ISI marked, round /triangular type as per sample for storage type electric water heater including taking down existing unserviceable element complete all as directed. .
Thermostat switch 220- 240 volt 16 Amp 0-75° /80° C ISI marked as per sample suitable for round including taking down existing complete all as directed.
Indicating lamp 230 volt AC for geyser fixed in repair of Green & Red colour complete all as directed.
Heavy duty PVC connection with 15mm dia 450mm long CP with brass nuts and leads PVC washer 02 Nos on each ends for geyser connection fixed in repair complete all as directed.
Metallic fastener screw 75mm long 6mm dia with bolt for hanging Geyser, complete all as directed.
PVC insulated copper cable size 3 core 70/.0076, AC 1100/660 volt including taking down existing unserviceable cable complete as directed.
Multifunction safety valve cast copper alloy 15 mm dia ISI marked complete including taking down existing valve all as directed.
Supply and fix in replacement of Water heater (Geyser) storage type, electric,capacity 25 litres.five star rated AC SP 230 volts, 50 Hz, vertical mount type, shockproof and rustproof metal body, stainless steel inner container, high efficiency heating element, autocut thermostate, pressure release safety system, fire retardent cable with 3 pin plug top, white colour including fixing accessories like fastensers, nuts, washers complete all as specified and directed. Make: Havells cat part No. GHWAMGTWH025 or equivalent in Bajaj/Usha/Recold.
Taking down Ceiling fan 1200/1400mm sweep of any make and set aside in safe custody for rewinding and servicing at local workshop and re-fixing the same as directed.
Taking down exhaust fan/cabin fan/ wall mounted fan of any sweep and set aside in safe custody for rewinding and servicing at local workshop and re-fixing the same as directed.
Rewinding of ceiling fan of any make with super enameled copper wire of same size as original including necessary varnishing of new coil insulation, overvauling etc complete all as directed of following sweeps:-
1200 mm sweep ceiling fan.
1400 mm sweep ceiling fan.
Re-winding of exhaust fan of any make with super enameled copper wire of same gauge as original including necessary varnishing to new winding coil insulation packing, overhauling, cleaning, greasing, reassembling and testing comple all as directed for the following sizes:-
250/300 mm sweep
350mm/450 mm sweep
Ball bearings of ceiling fan of any sweep fixed in repair all as directed of following sizes:-
6201 Make :- NBC/SKF/TATA
6202 :- NBC/SKF/TATA
6203 :- NBC/SKF/TATA
6204 :- NBC/SKF/TATA
Gun metal bushes as per sample fixed in repair complete all as directed.
Capacitor 2.5 mfd 230 volt AC 50 HZ suitable for ceiling fan/ exhaust/cabin/table fan of any sweep fixed in repair complete all as directed.
Capacitor 3.5 mfd 230 volt AC 50 HZ suitable for ceiling fan/ exhaust/cabin/table fan of any sweep fixed in repair complete all as directed.
Capacitor 04 mfd 230 volt AC 50 HZ suitable for ceiling fan/ exhaust/cabin/table fan of any sweep fixed in repair complete all as directed.
Capacitor 1/1.5 mfd 230 volt AC 50 HZ suitable for ceiling fan/ exhaust/cabin/table fan of any sweep fixed in repair complete all as directed.
Ball bearing of suitable size of exhaust fan/wall mounted fan 250 to 300mm sweep fixed in repair complete all as directed.
Ball bearing of suitable size of exhaust fan 300 to 450mm sweep fixed in repair complete all as directed.
Taking down and Preparation of old painted body and blades of ceiling fan 1200 mm to 1400 mm sweep of any make before cleaning foreign material filling cavities etc and painted with one coat of synthetic enameled paint by spray painting and marking MES No with paint and hanging as directed.
Taking down and Preparation of old painted body and blades of exhaust fan 300 mm to 450 mm sweep of any make before cleaning foreign material filling cavities etc and painted with one coat of synthetic enameled paint by spray painting and marking MES No with paint and hanging as directed.
Reel insulator of hard rubber of suitable size for ceiling fan fixed in repair complete all as directed.
PVC canopy of the ceiling fan with screw of any size fixed in repair complete all as directed.
Flexible copper cable of size 23/0.0076 with PVC insulated 2 core twisted 660 volts grade including taking down existing cable complete all as directed.
Down rod clamp in one piece or two piece with split pin, bolt , nut and washer as per sample complete fixed in repair all as directed.
Nuts, bolts and washer set 10mm dia, 75 mm long as per sample fixed in repair all as directed
Down rod of rigid steel cunduit of 15mm dia 60cm long for hanging fan with two cut in end of one side pipe approx length 1/2" to 2" and two holes for entering flexible cable both side, fixed in repair complete all as directed.
Down rod of rigid steel cunduit of 15mm dia 90cm long for hanging fan with two cut in end of one side pipe approx length 1/2" to 2" and two holes for entering flexible cable both side fixed in repair complete all as directed. Make: Jindal/Finolex/MK India/Asian
Down rod of rigid steel cunduit of 15mm dia 120cm long for hanging fan with two cut in end of one side pipe approx length 1/2" to 2" and two holes for entering flexible cable both side fixed in repair complete all as directed. Make: Jindal/Finolex/MK India/Asian
MS clamps with 40mmx4mm thick flat iron bent to shape any type having center two holes, nuts & bolts for hanging light fittings complete fixed in repair all as directed.
Exhaust fan blade metal/plastic set suitable for 250/300mm sweep as per sample fixed in repair complete all as directed.
Exhaust fan/wall mounted fan blade metalic set suitable for 450/600mm sweep as per sample fixed in repair complete all as directed.
Taking down ceiling fan and overhauling/servicing, cleaning, greasing, reassembling, hanging and testing of ceiling fan of any sweep 1200mm to 1400mm including cleaning and greasing material complete all as directed.
Taking down exhaust fan and overhauling/servicing, cleaning, greasing, reassembling and testing of Exhaust fans/wall mounted fans of any sweep (i.e. 250mm to 450mm) including cleaning and greasing/replacing any worn out part complete all as directed. Note :- (i) For servicing purpose Machine oil/grease should be used of apprpriate make only duly passed by the Engineer - in-Charge. (ii) replacement of any worn out part like bearing/ bush/shaft will measured & paid separately)
Split pin of suitable size fixed on nuts & bolts complete all as specified and directed
Louvers for exhaust fan of 250/300mm size fixed in repair on wall complete all as directed.
Louvers for exhaust fan of 450mm size fixed in repair on wall complete all as directed.
Blade screws of suitable size or as per site requirement complete with washer all as directed.
Metal ceiling fan blade suitable for 1200/1400 mm sweep as per sample fixed in repair all as directed.
Shaft suitable for exhaust fan / wall mounted fan / cabin or table fan as per sample complete fixed in repair all as directed.
Shaft suitable for ceiling fan of any type/size as per sample complete fixed in repair all as directed.
Supply and fix in replacement of ceiling fan 1200 mm sweep, 230 volts 50 Hz, energy saving model single phase, copper wound motor, five star, pearl white in colour complete with blade, down rod , canopy and connected with ceiling rose etc complete all as specified and directed. Make:- ES50 Premium of Havels & equivalent of Baja/Usha
Supply and fix in replacement of metal body exhaust fan 300 mm sweep, 900 rpm 230 volts 5h Hz, energy saving model single phase copper wound motor, grey in colour complete with blade, box type louvers etc complete all as specified and directed. Make:- Turbojet SP of Havels and equivalent of Bajaj/Usha.
Dismantling and taking out the non-functional water purifier of any description, any make and in any position of capacity upto 25 to 30 ltrs/hrs, including disconnection of water line connections, cleaning and general servicing of the water purifier , checking all serviceable parts, reassembling all parts of water purifier, restoring water supply connections and testing of the water purifier complete all as specified and directed by Engineer–in–charge. Note :-(i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item.(ii) Any minor complaints such as lekage of water, abnormal noise and any electric loose connection etc raised by user after carrying out servicing shall be rectified by the contractor without any extra cost to the Govt.(iii) The rate quoted for servicing shall be inclusive of attending complaints and keeping the water purifier in working condition during the entire contract period and further for defects liability period.
Supply only water purifier sediment filter set suitable for existing water purifier complete all as specified and directed. Make :- Make :- As approved by GE.
Supply only maimbren set suitable for existing water purifier complete all as specified and directed. Make :- Make :- As approved by GE.
Supply only Solonoid Valve suitable for existing water purifier complete all as specified and directed. Make :- As approved by GE.
Power supply, 240 volts, 50 Hz suitable for water purifier complete all as specified and directed. Make :- As approved by GE.
Supply only carbon filter suitable for water purifier complete all as specified and directed. Make :- As approved by GE.
Supply only water purifier booster water pump 24/48 watts suitable for water purifier complete all as specified and directed. Make :- As approved by GE.
Supply only tube jointer,bulkhead,elbow etc suitable for existing water purifier complete all as specified and directed. Make :- As approved by GE.
Supply only RO water flexible pipe,size 1/4-1 inch suitable for water purifier complete all as specified and directed. Make :- As approved by GE.
Surface and wall mounted LED batten with aluminium housing and integrated electronic driver with and including 40 W LED tube rod complete and connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to walls including taking down existing fitting complete all as specified and directed. Make:-Philips/Crompton/Havells,Cat No-STOUTPLUS1200BS40WLED857SPCHW
Material and labour for surface and wall mounted LED track light fitting 15 W, 230 volts AC, cool white with high power LED cylindro offers various luminous intensity levels from 1500-3500 lumens which is the perfect alternate to concentional HID lamps suitable for 3 circuit 4 wire universal tracks and connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting including taking down existing fitting and carefully without damaging existing light fittings and connected items complete all as directed. Make: Havells cat part No. CYLINDROTSS15W840S38DWHT or equivalent in philips, Wipro.
Material and labour for decorative round/square surface mounted slim LED panel of 18 watt with powder coated finished in white housing complete with all accessories and including LED lamp and connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to ceiling rose including taking down existing fitting and carefully without damaging existing light fittings and connected items complete all as specified and directed. Make: Havells cat part No. ENDURANEOHESURFACEDDLS18WLED857S or equivalent in philips, Wipro
Supply and fix in replacement of sky Cove LED strip especially designed for commercial use of length 50 meter suitable for surface and wall mounted LED 6 W complete all as spcified and directed. Make:-Philips,Product Code-92900 1 957209,Model No-578 and equivalent to Havells/Wipro.
Suspended circular type light fitting 36 W LED 230 volts AC, cool white luminaire combines uncompromising design with high levels and good ergonomics of size 600 mm dia and 70 mm height and connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement with chain upto 8 meters long for fixing the light fitting to ceiling including taking down existing fitting and carefully without damaging existing light fittings and connected items complete all as directed. Make: Havells cat part No. MONDO600RDP/S36WLED830SPSWH or equivalent in philips, Wipro
Supply and fix in replacement of track light of length 1meter suitable for fixing track/focus light fitting 15 W complete all as spcified and directed. Make:-Havells, Cat Part No-1MTR3PHASETRACKTSBLK and equivalent to Philips/Wipro
Prepration of surfaces and applying two coats of Mat finish synthetic enamal Asian/Burger paint anti rust /anti crossive to Split AC (Indoor + out door) complete all as specified and dierected by the Engineer -in-charge.
Flood light fitting energy saving and enviromental friendly long liife exclusive innovative made up of die cast aluminium housing with and including 50 Watt high power LED as lightnig source, suitable for highlighting archtectural features or area lighting also suitable for rough services/installations, including taking down existing fitting complete all as specified and directed. Make: Havells Cat part No. JETACOMPECTOFL50WLED757LTG or equivalent to Philips/Wipro.
Dismantling and taking out unserviciable split AC indoor unit and S&F split AC indoor unit suitable for existing Split type AC 1.5/2 TR capacity with copper coil complete including testing of nitrogen gas pressure and charging of gas R-22 upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge.
Dismantling and taking out unserviciable split AC outdoor unit and S&F split AC outdoor unit suitable for existing Split type AC 1.5/2 TR capacity complete including testing of nitrogen gas pressure and charging of gas R-22 upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge.
Supply only Voltage Stabilizer single phase for automatic operation , naturally air cooled wall mounting type and designed for input voltage between 170 Volts to 250 Volts with output stabilizes voltage 230 Volts with accuracy of + 2.5 % having digital display with time delay of 5 minits initially starts of capacity 5 KVA complete all as specified and directed. Make :- Livguard,Model No LA415-VX/and equivalent to Blue bird/ V Guard.Guard
Supply only Voltage Stabilizer single phase for automatic operation , naturally air cooled Suitable for refrigerator and designed for input voltage between 170 Volts to 250 Volts with output stabilizes voltage 230 Volts with accuracy of + 2.5 % having digital display with time delay of 5 minits initially starts of capacity 3 KVA complete all as specified and directed . Make :- V-Guard Model No.VGSD 50 Supreme or equivalent of Microtech/Blue bird.
Supply only Voltage Stabilizer single phase for automatic operation , naturally air cooled Suitable for refrigerator and designed for input voltage between 170 Volts to 250 Volts with output stabilizes voltage 230 Volts with accuracy of + 2.5 % having digital display with time delay of 5 minits initially starts of capacity 4 KVA complete all as specified and directed . Make :- V-Guard Model No.VGSD 50 Supreme or equivalent of Microtech/Blue bird.
Supply and fix in replacement of plastic body exhaust fan 250 mm sweep, 900 rpm 230 volts 5h Hz, energy saving model single phase copper wound motor, white in colour complete with blade, box type louvers etc complete all as specified and directed. Make:- Air -DX White of havels and equivalent to Bajaj/Usha.
Taking out existing defective window/Split AC electric motor of 930 RPM, 1/8,1/5 HP 220 volts single phase strip opening for rewinding, removing for rewinding to & from to workshop as approved by Engineer-in-Charge, rewinding with appropriate size copper super enameled wire (Make : Atlas /Finolex /Devi Dayal ) as approved by the engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop to the entire satisfaction of Engineer-in-charge and transportation & fixing the motor at site including necessary connection & testing at site complete all as specified and directed by Engineer-in-Charge.
MCCB 125 Amps 4 pole 415 volts with rupturing capacity 16 KA with thermal magnetic release and adjustable overload setting having including taking out existing unserviceable MCCB complete all as directed.
MCB DB, sheet metal enclosures double door SPN 8 way with 200 Amps rated bus bar 240 volts 2 in 1 shutter (Metal Door) type with blanking plates where required and IP 43 degree protection fixed in repair complete all as directed.
MCB DB, sheet metal enclosures double door SPN 12 way with 200 Amps rated bus bar 240 volts 2 in 1 shutter (Metal Door) type with blanking plates where required and IP 43 degree protection fixed in repair complete all as directed.
Ansh Enterprises
M/s Anamika Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .