| 1 | L1₹3.3 CrAccepted-AOC BASEMENT PLOT NO 17 4657 21 ANSARI ROAD CENTRAL DELHI NEW DELHI 110002 | CENTRAL DELHI | DELHI | 110002 | ₹3.3 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹3.6 CrRejected-Finance 104 INDIRA MARKET NEAR MALAI MANDIR SECTOR 07 RK PURAM NEW DELHI PIN 110022 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110022 | ₹3.6 Cr | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹3.6 CrRejected-Finance | ₹3.6 Cr | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹5.4 CrRejected-Finance | ₹5.4 Cr | L4 | Rejected-Finance Other than L1 |
| 5 | Rejected-Technical | - | - | Rejected-Technical The firm is two class below the eligible class. Since,the work is not pertains to difficult and remote area,hence rejected |
| Sl No | Description | Qty | Unit | VINAY ENTERPRISES L1 | Mohit Infratech L2 | Vinay Shankar L3 | GRID ENGINEERS L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead complete all as specified & directed : Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) | 80 | Cum | 500 ₹40,000 | 525 ₹42,000 | 400 ₹32,000 | 1,500 ₹1.2 L |
| 2.00 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead complete all as specified & directed : Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) | 114 | Cum | 400 ₹45,600 | 360 ₹41,040 | 300 ₹34,200 | 2,200 ₹2.5 L |
| 3.00 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead complete all as specified & directed. | 5 | Cum | 1,000 ₹5,000 | 760 ₹3,800 | 800 ₹4,000 | 2,500 ₹12,500 |
| 4.00 | Demolishing brick work manually/ by mechanical means stacking of serviceable material and disposal of unserviceable material within 50 metres lead complete all as specified & directed: In cement mortar | 10 | Cum | 300 ₹3,000 | 290 ₹2,900 | 200 ₹2,000 | 2,250 ₹22,500 |
| 5.00 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below | 49 | Each | 100 ₹4,900 | 140 ₹6,860 | 150 ₹7,350 | 550 ₹26,950 |
| 6.00 | Dismantling steel work in built up sections in angles, tees, flats and channels including all guest plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead complete all as specified & directed. | 500 | Kg | 3 ₹1,500 | 7 ₹3,500 | 3 ₹1,500 | 4 ₹2,000 |
| 7.00 | Dismantling WC pan of all sizes including disposal of dismantled materials i/c malba all complete all as specified & directed. | 5 | Each | 100 ₹500 | 115 ₹575 | 100 ₹500 | 325 ₹1,625 |
| 8.00 | M&L for cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, complete all as specified & directed. Bars above 8 mm diameter. | 58 | Rm | 10 ₹580 | 12 ₹696 | 18 ₹1,044 | 10 ₹580 |
| 9.00 | Dismantling tile work in floors and roofs laid in cement mortar including taking out demolished malba outside MoD land up to any lead complete all as specified & directed : For thickness of tiles 7 mm to 25 mm | 1,350 | Sqm | 200 ₹2.7 L | 175 ₹2.4 L | 200 ₹2.7 L | 100 ₹1.4 L |
| 10.00 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead complete all as specified & directed | 1,008 | Sqm | 40 ₹40,320 | 75 ₹75,600 | 225 ₹2.3 L | 150 ₹1.5 L |
Updated dates
Tender Value
₹3.6 Cr
EMD Value
₹4.4 L
Closing Date
23 Dec 2025, 6:00 pmClosed
Chief Engineer (RnD) Delhi
HQ CE (RnD) Delhi Probyn Road Delhi-110054
SPECIAL REPAIRS CUM ADDITION/ALTERATION OF BUILDING NO. P-1 MAIN BUILDING (GROUND FLOOR) AND P-2 (ADM BLOCK) AT SSPL, DELHI UNDER GE (I) RnD DELHI
2025_MES_732434_2
CE RnD/DLI-26/DLI/2025-26
Open Tender
Civil Works
365 days
Delhi
As per tender documents
8 documents required · 8 mandatory
₹2,000
GE (I) RnD Delhi
₹4.4 L
Yes
23 Feb 2026
27 Nov 2025
30 Dec 2025
27 Nov 2025
23 Dec 2025
4 Dec 2025
Amount
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead complete all as specified & directed : Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead complete all as specified & directed : Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead complete all as specified & directed.
Demolishing brick work manually/ by mechanical means stacking of serviceable material and disposal of unserviceable material within 50 metres lead complete all as specified & directed: In cement mortar
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below
Dismantling steel work in built up sections in angles, tees, flats and channels including all guest plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead complete all as specified & directed.
Dismantling WC pan of all sizes including disposal of dismantled materials i/c malba all complete all as specified & directed.
M&L for cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, complete all as specified & directed. Bars above 8 mm diameter.
Dismantling tile work in floors and roofs laid in cement mortar including taking out demolished malba outside MoD land up to any lead complete all as specified & directed : For thickness of tiles 7 mm to 25 mm
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead complete all as specified & directed
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material outside Mod land and stacking of serviceable material with in 50 meters lead complete all as specified & directed.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified & directed
Demolishing lime concrete manually / by mechincal means and disposal of material within 50 metres lead complete all as specified & directed.
Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead complete all as specified & directed : 100 mm dia pipe.
Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 Rms lead complete all as specified & directed : 150 mm dia pipe.
Dismantling of EWC cistern of all types wash basin including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead complete all as specified & directed.
Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 15 mm to 40 mm nominal bore
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth outside MoD land upto any lead and lift complete all as specified & directed : All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil outside MoD land upto any lead and lift complete all as specified & directed. : All kinds of Soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m complete all as specified & directed.
Supplying chemical emulsion in sealed containers including delivery as specified : Chlorpyriphos/Lindane emulsifiable concentrate of 20% complete all as specified & directed.
M&L for diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration complete all as specified & directed.
M&L for diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration complete all as specified & directed.
M&L for providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to and above plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) complete all as specified & directed.
M&L for providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to and above plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) complete all as specified & directed
M&L for providing and laying Reinforced cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) complete all as specified & directed
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like complete all as specified & directed.
Centering and shuttering including strutting, propping etc. and removalof form for all heights complete all as specified & directed : Shelves (Cast-in-situ)
Centering and shuttering including strutting, propping etc. and removalof form for all heights complete all as specified & directed: Lintels, beams, plinth beams, girders, bressumers and cantilevers
M&L for reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size) complete all as specified & directed.
M&L for steel Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all height & level including foundation complete all as specified & directed: Thermo-Mechanically Treated bars of grade Fe-500D or more
M&L for brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) complete all as specified & directed.
M&L for half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level : Cement mortar 1:4 (1 cement :4 coarse sand) complete all as specified & directed.
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry complete all as specified & directed.
M&L for providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel SS screws, complete all as specified & directed. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion : Powder coated aluminium (minimum thickness of powder coating 50 micron)
M&L for providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel SS screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron) complete all as specified & directed
M&L for providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel SS screws etc. complete as per architectural drawings complete all as specified & directed : Prelaminated particle board with decorative lamination on both sides
M&L for providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings complete all as specified & directed. (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 4.0 mm thickness
M&L for providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings complete all as specified & directed. (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
M&L for providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws complete all as specified & directed
M&L for providing and fixing wooden moulded beading to door and window frames with iron SS screws, plugs and priming coat on unexposed surface etc. complete all as specified & directed : Kiln seasoned and chemically treated hollock wood : 50x12 mm
M&L for providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary SS screws etc. complete all as specified & directed : Powder coated minimum thickness 50 micron aluminium.
M&L for providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and SS screws etc. complete all as specified & directed.
M&L for providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc complete all as specified & directed : 300x16 mm
M&L for providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete all as specified & directed : 250x16 mm
M&L for providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified & directed : 300x10 mm
M&L for providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified & directed : 250x10 mm
M&L for providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified & directed : 200x10 mm
M&L for providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified & directed : 150x10 mm
M&L for providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified & directed : 100x10 mm
M&L for providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified & directed : 125 mm
M&L for providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified & directed : 100 mm
M&L for providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete all as specified & directed : Twin rubber stopper
M&L for providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete all as specified & directed : Powder coated minimum thickness 50 micron aluminium
M&L for filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and complete all as specified & directed : Upto 5 mm depth and 5 mm width
M&L for steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required : In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works complete all as specified & directed
M&L for providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer : M.S. tube complete all as specified & directed
M&L for providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and complete all as specified & directed . (Only weight of grill to be measured for payment).
M&L for providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels : Granite Stone Slab of any Colour complete all as specified & directed
M&L for providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge : Granite work
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete all as specified & directed .
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete all as specified & directed .
M&L for providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades, design , pattern including highlighter tiles as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete : Size of Tile 600mm x 300mm
M&L for providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for eparately) : Second class teak wood
M&L for providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
M&L for providing and laying Double Charged Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete : Size of Tile 600mm x 600 mm
M&L for providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in any colors, shade, pattern as approved by Engr-in-charge such as laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete all as specified & directed .
M&L for providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and confirming to IS:15622, of approved brand and manufactuerer, in all colour and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with gray cement slurry @ 3.3kg/Sqm including grounting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clip of required thickness, leveling system and rubber mallet for placing the tiles gently and easilty : Double Charged vitrified tiles polished finished of size 600mm x 600mm complete all as specified & directed
M&L for providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. complete all as specified & directed : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
M&L for providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. complete all as specified & directed : Polished Granite stone slab of any colour as approved by Engr-in-charge
M&L for kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick complete all as specified & directed.
M&L for kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete all as specified & directed.
M&L for providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete all as specified & directed
M&L for providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall SS screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall SS screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks)
M&L for providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-incharge : With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6
M&L for providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with : GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation complete all as specified & directed.
M&L for providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours : Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry complete all as specified & directed.
M&L for drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintel, columns and slabs to introduce steel bars for sunshades/ balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete all as specified & directed : Upto and including 12mm dia
M&L for providing mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and complete all as specified & directed : Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make
M&L for cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast complete all as specified & directed.
M&L for providing mixing and applying SBR polymer (of approved make) modified cement mortar in proportion of 1:4 (1 cement : 4 coarse sand with polymer minimum 2% by wt. Of cement used) complete all as specified & directed : 25mm average thickness in 2 layers
M&L for providing mixing and applying SBR polymer (of approved make) modified cement mortar in proportion of 1:4 (1 cement : 4 coarse sand with polymer minimum 2% by wt. Of cement used) complete all as specified & directed : 50mm average thickness in 3 layers
M&L for chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts complete all as specified & directed : 75mm average thickness
M&L for shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineerin- Charge : 75mm thick in Grade M 25 with cement content not less than 330 kg per cum Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument.
M&L for 12 mm cement plaster of mix : 1:6 (1 cement : 6 fine sand) complete all as specified & directed
M&L for 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement : 6 fine sand) complete all as specified & directed
M&L for providing External cement plaster 20mm thick in single coat in cement mortar 1:4 without neeru finish to concreteor brick surfaces in all position including scaffolding and curring complete all as specified & directed .
M&L for 6mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) complete all as specified & directed.
M&L for repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking outjoints and preparing and plastering the surface of the walls complete, including disposal of rubbish outside MoD land up to any lead complete all as specified and directed: With cement mortar 1:4 (1 cement : 4 fine sand)
M&L for extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers complete all as specified & directed
M&L for 15 mm cement plaster in two coats under layer 10 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 5 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge complete all as specified & directed.
M&L for providing and fixing Stainless steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittingsand brackets, cutting and making good the walls wherever required (Nirali Grace Plain / approved equivalent) : Kitchen sink with drain board : 510x1040 mm bowl depth 250mm complete all as specified & directed
M&L for providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fitting complete all as specified & directed : Flexible pipe : 32mm and 40mm dia as per requirement
M&L for providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100mm inlet and 100mm outlet : Sand cast iron S&S as per IS:3989 complete all as specified & directed
M&L for providing and fixing soil, waste and vent pipes : 100 mm dia : Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS:3989 complete all as specified & directed.
M&L for providing and fixing single equal plain junction of reqd. degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete all as specified & directed : 100x100x100mm : Sand cast (spun) iron pipe IS-3989
M&L for providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete all as specified & directed : 100x100x100mm : Sand cast (spun) iron pipe S&S as per IS 3989.
M&L for providing and fixing bend of required degree : 100mm dia : Sand cast (spun) iron pipe S&S as per IS 3989. complete all as specified & directed.
M&L for providing and fixing heel rest sanitary bend : 100mm dia : Sand cast (spun) iron pipe S&S as per IS 3989 complete all as specified & directed.
M&L for providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete all as specified & directed : 100x100x100x100 mm : Sand cast (spun) iron pipe S&S as per IS 3989.
M&L for providing and fixing terminal guard : 100mm : Sand cast (spun) iron pipe S&S IS-3989 complete all as specified & directed.
M&L for providing and fixing collar : 100mm : Sand cast (spun) iron pipe S&S IS-3989 complete all as specified & directed.
M&L for providing and fixing MS holder bat clamps of approved design to cast iron (spun) pipe embedded in and Including cement concrete blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc : For 100mm dia. Pipe complete all as specified & directed.
M&L for painting sand cast iron / centrifugally cast iron( spun) iron soil, waste and vent pipes and fittings with paint of any colour over a coat of primer (of approval quality) for new work : 100mm dia cast (spun) iron S&S pipe complete all as specified & directed.
M&L for providing lead caulked joints to sand cast iron/centrifugally cast(spun) iron pipes & fittings of diameter : 100mm complete all as specified & directed.
M&L for providing and fixing M.S. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 100mm complete all as specified & directed.
M&L for providing and fixing square mouth SW gully trap class SP-1 complete with CI grating brick masonry chamber and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg. as per standard design : 180x150mm size P type : with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 complete all as specified & directed.
M&L for providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipecomplete all as specified & directed.
M&L for providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 150 mm diameter S.W. pipes complete all as specified & directed.
M&L for providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge : 20mm Outer Dia of Pipe complete all as specified & directed.
M&L for providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge : 25mm Outer Dia of Pipe complete all as specified & directed.
M&L for providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge : 32mm Outer Dia of Pipe complete all as specified & directed.
M&L for providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete all as specified & directed : Concealed work, including cutting chases and making good the walls etc. : 20mm Outer Dia of Pipe
M&L for providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete all as specified & directed : Concealed work, including cutting chases and making good the walls etc. : 25mm Outer Dia of Pipe
M&L for providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete all as specified & directed : Concealed work, including cutting chases and making good the walls etc. : 32mm Outer Dia of Pipe complete all as specified & directed.
M&L for providing and fixing brass stop cock of approved quality complete all as specified & directed : 15mm nominal bore
M&L for providing and fixing brass stop cock of approved quality complete. : 20mm nominal bore complete all as specified & directed.
M&L for providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20mm nominal bore complete all as specified & directed.
M&L for providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25mm nominal bore complete all as specified & directed.
M&L for providing and fixing C.P. bass angle valve for basin mixer and geyser points of approved quality conforming to I.S:8931 a) 15 mm nominal bore : 15 mm nominal bore complete all as specified & directed.
M&L for providing and fixing unplasticised P.V.C connection pipe with PTMT Nuts coller and bush of approved quality and colour : 15mm nominal bore with 45cm length complete all as specified & directed.
M&L for providing and fixing white vitreous china pedestal type water closet (European Type) with sit & lid, 10 ltrs low level white vitreous china flushing cistern and CP flush bend with fitting and GI brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : WC pan with ISI marked white solid plastic seat and lid complete all as specified & directed.
M&L for providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350 mm and 340 x 410 x 265 mm sizes respectively with automatic flushing cistern with standard flush pipe and CP brass spreaders with brass unions and GI clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of three urinal basins with 10 ltrs white PVC automatic flushing cistern complete all as specified & directed.
M&L for and fixing wash basin with GI brackets, 15 mm CP brass pillar taps, 32 mm CP brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous china wash basin with size 630 x 450 mm with a pair of 15 mm CP brass pillar taps complete all as specified & directed.
M&L for and fixing beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats / ss Studs with C.P. brass SS screws and washers complete all as specified & directed.
M&L for providing and fixing toilet paper holder : CP Brass complete all as specified & directed.
M&L for providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. Automatic flushing cistern complete all as specified & directed.
M&L for providing and fixing CP brass long nose bib cock of approved quality confirming to IS standards and weighing not less than 810 gms : 15 mm nominal bore complete all as specified & directed.
M&L for distempering with 1st quality acrylic distemper (ready mix) having VOC content less than 50 gram/ltre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New and Old Work (Two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/ltre.
M&L for painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
M&L for French spirit polishing : Two or more coats on new works including a coat of wood filler complete all as specified & directed.
M&L for providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete all as specified & directed.
M&L for finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New and old work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified & directed.
M&L for finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm complete all as specified & directed.
M&L for painting (two or more coats) on rain water, soil waste and vent pipes and fittings with black anticorrosive bitumastic paint of approved brand and manufacture, over and including a priming of ready mixed zinc chromate yellow primer on new and old work : 100mm diameter pipes complete all as specified & directed.
M&L for providing and applying two coats of fire retardant paint on cleaned wood / ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant complete all as specified & directed.
M&L for painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Old work (one or more coats) complete all as specified & directed.
M&L for grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) complete all as specified & directed.
Grading roof for water proofing treatment with Cement mortar 1:3 (1 cement : 3 coarse sand) complete all as specified & directed.
M&L for providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner complete all as specified & directed.
M&L for injecting nozzle packing : Drill and fixing injection packers in RCC members for cementitious grouting, drilling holes in structural members at the interva;l as per recommendation/requirement, cleaning the holes by air blower prior to fixing nozzles. insert 12mm dia, 50-75 long PVC or equivalent injection packers in cleaned holes with fast setting mortar of approved water proofing manufacturer . Cut the packers by cut of wheel after completion of the grouting without damaging structural elements. Injection Grouting : Supply and applying with presuure (mechanical means) plasticuised expanding grout admixed cementitious grout of approved manufacturer having chloride contents - Nil as per BS-5075, typical unrestricted expansion of upto 4% in general. The admixed should be mixed @ 225 gms per 50 Kg of cement complete all as specified & directed.
M&L for hacking up the corners using suitable mean, later cleaning the same using water, followed by the application of Nitobond SBR latex or or equivalent of approved manufacturer with mixed slurry coat (1 SBR : 1 Water : 3 Cement) & later filling and making 100mm x 100mm concave coving using Nitobond SBR latex or equivalent from approved manufacturer admixed polymer modified mortar including finishing, curing etc complete all as specified and directed.
M&L for complete removal of existing water proofing treatment including PCC padding/brick tiles/brick coba and mud phaska etc without damaging the existing slab complete all as directed and M&L for preparation of surfaces to achieve clean and sound concrete surfaces float finished and free from cavities and projecting nibs. All substrates should be dry clean and free of dust, plaster, oil, paint, grease, corrosion, deposits and any other deleterious substances complete all as specified and directed.
M&L Crackes/honey comb will be repaired by chasing open the area minimum 20mm depth in V-groove shape. All the chased substrate should be sound and cleaned using water. Smooth substrate must be mechanically roughened to provide an adequate key applying boand coat on the prepared surfaces with Nitobond SBR latex or equivalent from approved manufacturer mixed with slurry coat (1 SBR : 1 Water : 3 Cement). Reinstallement polymer modified mortar shall be complete within the the overlay time of boanding coat. Later reinstating the chased area with Nitobond SBR latex or equivalent from approved manufacturer polymer modified mortar finishing, curing complete all as specified and directed.
M&L for providing and applying one layers of proofex torchseal-3PI strandard or equivalent from approved manufacturer : 3mm thick non-woven polyster mat reinforced APP modified bitiminious membrane. The system is applied in one layers. Membrane to be overlapped for 100mm sideways and 150mm at the end laps with each having following specifications : (a) Membrane thickness : 3mm (+/- 10%) (b) Tensile Strength ASTM D5147 : > 400 N/5Cm (L&T) (c) Tensile tear strength ASTM D4073 : 200 N/5 Cm (d) Resistance to water pressure DIN 52123 : No Leak (e) Elongation ASTM D5147 (f) Water tightness (EN 1928-1) kPa : 60m System included priming the substrate with Proofex Torchseal Primer of approved manufacturer @ 0.40 Ltr/Sqm. Provision and application of 3mm thick proofex torchseal-3PI strandard or equivalent from approved manufacturer membrane in one layer and termination of the membrane at 450mm from the roof level in groove of 50mm x 50mm filled with Nitoseal PU 50 or equivalent from approved manufacturer
Supply and fixing of Single layer Roller blinds of approved make & approved shade including aluminium hollow circular pipe, roller mechanism, side end caps, brackets including all necessary fitting etc complete all as specified & directed.
M&L for providing and fixing wooden panel in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) : With 12 mm commercial ply wood conforming to IS: 303 BWR grade with Both sides finished with1 mm thick decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S complete all as specified & directed.
M&L for providing and fixing Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white color and other side of board laminted with PVC foil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/ kitchen cabinet etc. of required sizes comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified & directed.
Extra for providing frosted glass panes 5 mm thick instead of ordinary float glass panes 5 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).
M&L for providing, fixing and fabricating of 75 mm thick full height partition up to false ceiling level as directed , fabricated out of Aluminium box section frame work 12 mm thick MDF on both side of frame , 1 mm thick lamination on exposed surface and 20 x 80 mm Teak wood edge moulding in approved shape including making of glazed opening not more than 25% partition area with 8 mm thick glass and 15 x 40 teak wood beading in approved shape etc . Frame work of partition shall go up to ceiling level and measurement of partition shall be only up to false ceiling level . complete with all hardware like nails , screws , fasteners, glue etc . two or more coats of melamine polish where required complete all as specified & directed. (Aluminium box section frame will be use from existing partition ) .
M&L for providing and fixing Iinterlocking deadbolts ISI marked with 6 Levers double chal mechanism ( Operable by key from both side of the door ) with Key Hole, necessary SS screws etc. complete all as specified & directed. (best make of approved quality).
M&L for providing and fixing of rubber nylon door buffer (dia of 40mm and 50mm long) on wall with rowl plug and screw complete all as specified & directed.
Extra for Providing and fixing on existing gypsum board false ceiling , 12 mm thick medium density fibre board IS: 14587:1998 marked fixed , 4 mm thick one side decorative veneer conforming to IS : 1328 (type - I) over MDF board as per approved pattern including all nails , screw , glue , paint / polishing with laquared finish all exposed edges board / plywood to be covered with 4 mm thick teak wood lipping complete all as specified & directed.
M&L for providing and placing of Workstation of size 1200X600 mm and 1200 mm high as per shape and size and approved by Engr-in-charge. Provide 3 Nos.400 mm wide wooden drawers, wooden Keyboard tray, wooden CPU stand on wheels all as per approved drawing and sample as per GE office, all drawers with individual lock and telescopic sliding rail as instructed by Engineer-in-Charge,Work top as per approved shape and size, fabricated with 19 mm thick water proof commercial block board in all sides, top, bottom and front, 6 mm thick plywood drawer bottom ,1 (one) mm thick lamination as approved on all exposed surface of side unit 32X32 mm Teak / Cedar wood moulding on work top as instructed by Engineer-in-Charge, 3 to 4 mm thick Teak / Cedar wood margin or PVC edge bending on all straight, side and top on all exposed edges complete with all labour and material, Painting/polishing finished with polyurethane, nails, screws, glue and other accessories etc. complete all as specified & directed.
M&L for providing and fixing of low height Partition consisting of bare Aluminium box section frame of size 50X50X2 mm provided at 400 mm c/c in both directions. Frame shall be secured with the help of dash fasteners of approved brand and sample, in plumb and line, 12 mm thick waterproof plywood to be fixed on both side of frame with screws .1 mm thick lamination of approved sample to be pasted on plywood with glue as per pattern and instruction by Engineer-in-Charge. 100X20mm Teakwood moulding as per approval sample and shape shall be fixed on the edges of partition to cover the ends of plywood and aluminium frame. The partition rate include all material and labour including making hole and openings for electrical conduits and boxes, all painting/polishing finished with Polyurethane, all fasteners, nails, screws, glue, etc. complete complete all as specified & directed.(Free standing partition exposed on both sides)
M&L forJacketting the existing column of size as shown in the drawing by removing the concrete cover to reinforcement, by chipping or other suitable means to expose the reinforcement of existing column in order to make available the same for binding the extra reinforcement as shown in the drawing and also removal of rust, scales of the reinforcement in order to provide and applying approved make of epoxy resin to get proper bond with newly laid M25 grade concrete. The aforsaid concrete shall be laid by the sides of the existing column with inifrom thickness of 115 mm or as specified, for jacketing purpose thereby increasing the sectional dimensions by 150mm or as specified (excluding finishing) at any height with requisite shuttering, centring, scaffolding, proping, repairing the existing surface as specified and also removal of debris, curing etc. complete as per design and drawing etc. directed. (Note:Reinforcement will be paid separately under respective item of schedule.)
M&L for providing & fixing in position C.P. brass twin coat hook including cutting necessary C.P. brass SS screws complete all as specified & directed.
M&L for providing and fixing C.P. brass long body 15 mm nominal bore bib cock of approved quality conforming to IS standards and weighing not less than 690 gms complete all as specified & directed.
M&L for providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make complete all as specified & directed.
M&L for providing and fixing 100mm CP brass grating for trap of approved make complete all as specified & directed.
M&L for providing & fixing urinal partition of 12 mm thick toughened glass ( size 675 x 330 mm) complete with stainless steel cleat of standerd size with bolts nuts for fixing to wall complete all as specified & directed.
M&L for providing & fixing in position C.P. brass towel rail (600mm long) including cutting necessary C.P. brass SS screws complete all as specified & directed.
M&L for providing & fixing in position CP soap dish complete all as specified & directed.
M&L for Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified & directed.
M&L for Wiring light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required complete all as specified and as directed.
M&L for one point wiring of with PVC insulated FRLS unsheathed copper cable of size 4.0 sqmm including earth wire of size 4.0 Sqmm in and including Concealed rigid 20 mm dia PVC conduit and GI flush box for 15 amps power point including cutting chases for conduit where required and making good to wall and ceiling complete all as specified and as directed .
Supply and fixing in replacement of 3 module modular base and cover plate on exixting modular metal boxes as required complete all as specified & directed.
Supply and fixing 15/16 A modular switches on existing modular base plate and switch box including connection but excluding modular plate as required complete all as specified & directed.
Supplying and fixing in replacement 05/06 Amp modular Socket outlet 3 pin 5/6 Amp including connections but excluding modular plate etc. as required complete all as specified and as directed.
Supplying and fixing in replacement 15/16 Amp modular Socket outlet 6 pin 15/16 Amp including connections but excluding modular plate etc. as required complete all as specified and as directed.
S&F Fan step type regulator 120W - 2 module complete all as specified and as directed.
M&L for in renewal of sub main wiring 2x4.0 sqmm and 1x4 Sqmm earth wire PVC insulated FRLSH multistranded copper conductor ISI marked 1100 V grade including PVC conduit or fixed in wall/floor, passing through wall/ceiling complete complete all as specified and as directed.
M&L for in renewal of sub main wiring 2x6 sqmm and 1x6 Sqmm earth wire PVC insulated FRLSH multistranded copper conductor ISI marked 1100 V grade including PVC conduit fixed in wall/floor, passing through wall/ceiling complete all as specified and as directed.
M&L for in renewal of sub main wiring 4x10 sqmm and 2x10 Sqmm earth wire PVC insulated FRLSH multistranded copper conductor ISI marked 1100 V grade including PVC conduit fixed in wall/floor, passing through wall/ceiling complete all as specified and as directed.
M&L for in renewal of sub main wiring 4x16 sqmm and 2x16 Sqmm earth wire PVC insulated FRLSH multistranded copper conductor ISI marked 1100 V grade including PVC conduit fixed in wall/floor, passing through wall/ceiling complete all as specified and as directed.
Material and Labour for earthing in any type of soil complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.5 meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below and above 15 cm of earth plate. GI plate connected with galvanised iron wire 4mm dia by means of nuts, bolts and washers. GI wire laid in 15 mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) complete all as shown in doctric plate No 5 of SSR Part-I with following:- (a) GI wire of size 4mm . (b) Watering pipe GI medium grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embedded in floor of PCC earth pit. (GI Funnel should properly tightened on GI watering pipe and embedded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm (internal dimension) 120mm thick wall in PCC 1::4 type B1 on 500x500x150mm PCC base 1:3:6 concrete exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC 1:2:4 type B-1 pit cover 25mm thick reinforced with 8 mm dia deformed bars @ 100 mm c/c both ways with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover and angle iron frame of 40x40x4mm complete. (d) Angle iron frame made of 40x40x4 mm for 30x30 cm PCC pit for holding the pit cover. (e ) Apply two coat of synthetic enamel paint over one coat of red oxide zinc chrome primer on exposed steel surfaces and two coat of hot tar on embedded portion of steel surfaces.
S&F in replacement energy efficient LED light fitting surface mounted 4' long, 20 watt, 240 volts, 50 hz made out of extrunded aluminium housing with acrylic diffuser, LM 80 certified LED, costant current out put of electronic driver of operating voltage 140v to 270v and temperature - 10 digree centigrade to 50 digree centigrade with ingress protection IP 20 duly pre wired with insulated copper wire, PF>0.95 with efficiency 120 lumins/watt and TDH less than 10%, CRI > 90 digree , CCT 6500 K in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose complete all as specified and directed.
S&F in replacement energy efficient LED light fitting surface mounted 2' long, 10 watt, 240 volts, 50 hz made out of extrunded aluminium housing with acrylic diffuser, LM 80 certified LED, costant current out put of electronic driver of operating voltage 140v to 270v and temperature - 10 digree centigrade to 50 digree centigrade with ingress protection IP 20 duly pre wired with insulated copper wire, PF>0.95 with efficiency 120 lumins/watt and TDH less than 10%, CRI > 90 digree , CCT 6500 K in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose complete all as specified and directed.
S&F in replecement energy efficient LED light fitting, slim LED panel, recessed mounting 2 ftx 2 ft made out of power coated CRCA sheet with acrylic diffuser, constant current output of electronic driver operating voltage range of 150 to 270 volts AC, PF>0.95, high powder LEDs having efficiency of 100-120 lumins/watts, junction temparature less than 85 digree C and TH less than 12 % and CCT 6500K,, CRT>90 suitable for 36 watt LED, LM 80 certified LM, pri wired in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose /connector etc and testing complete all as specified and directed.
S&F in replecement energy efficient LED light fitting, slim LED panel, surface mounting 2 ftx 2 ft made out of power coated CRCA sheet with acrylic diffuser, constant current output of electronic driver operating voltage range of 150 to 270 volts AC, PF>0.95, high powder LEDs having efficiency of 100-120 lumins/watts, junction temparature less than 85 digree C and TH less than 12 % and CCT 6500K,, CRT>90 suitable for 36 watt LED, LM 80 certified LM, pri wired in and including connecting up with twin core copper flexible cable of suitable size upto ceiling rose /connector etc and testing complete all as specified and directed.
S&F ceiling rose 3 terminal/PVC/polycarbonate, isolated body 6A complete all as specified.
Supply and fixing in replacement of MCB distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating, SPN 12 way. 230 volts with bus bar rating 100 Amps, dust and vermin proof and IP 43 - IK 09 protection suitable for incorporation of MCB, including grouting in the wall, cutting & chasing etc. complete all as specified.
Supply and fixing in replacement of old MCCBs TPN distribution board double door vertical type made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating, suitable for MCCB for capacity 125Amp, 16 KA, Incomer 8 ways 415 Volts double door vertical type CRCA sheet with bus bar rating 200 Amps Adjustable thermal (70% to 100%) & Fixed magnetic setting type complete all as specified
S&F in repair MCCB Four pole 100 Amps 16kA, with thermal magnetic/electronic trip unit complete all as specified and directed by Engr-in-charge.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 6 to 32 Amps poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified & directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
Supply and fix exhaust fan, steel body AC single Phase. 230V, 50 Hz of size 380mm sweep with motor, blades,frame and louvers complete all as specified.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with motor, louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified.
S&F DLP trunking system plastic adoptable type 105X50mm with 2 compartment duly covered installed with suitable mosaic support joints including all accessories complete all as specified and as directed.
Supplying and installing 100mm width x 50mm depth x 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness note less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including GI bolts & nuts etc. as required.
Supplying and making end termination with brass compression gland and aluminium lugs for 4 x 10 sq.mm (25mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required complete all as specified & directed.
Supplying and making end termination with brass compression gland and aluminium lugs for 4 x 16 sq.mm (28mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supplying, installation, testing & commissioning of microprocessor base addressable repeater panel with 320 character/ Touch screen LCD display, LED inication duly compliance with LPCB and EN 54-2, 24 V DC having surge and short circuit protection, MS powder coated enclousre with IP 50 protection with inbuilt reset, acknowledge and silence switches complete all as specified & directed. (i) FACP shall be operate under environment indoor temp -10⁰C +50⁰C with RH<95% (ii) The contractor shall submit technical data sheet of Fire alarm repeater panel before procurement for approval of accepting officer.
Supplying, installation, testing & commissioning of intelligent analog addressable photo thermal detector (multi sensor) duly compliance with EN-54 dual LED indication with base with inbuilt isolator as per IS: 2175 complete with mounting base complete all as specified & directed.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc. complete all as specified & directed.
Supplying, installation, testing & commissioning of intelligent addressable programmable sounder complete all as specified & directed .
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of addressable manual call point resettable type with inbuilt isolator, LED status and alarm indicator, surface/flush mounted with lock and key arrangement complete all as specified & directed.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete all as specified & directed.
Supplying, installation, testing & commissioning of fire fighter telephone handsetcomplete all as specified & directed.
Supplying, installation, testing & commissioning of fire fighter phone jack complete all as specified & directed.
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete all as specified & directed.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit complete all as specified & directed.
Supplying and fixing of 25mm sizes of medium class PVC conduit alongwith accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing Telephone socket outlet modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. scomplete all as specified & directed.
Supplying and fixing TV antenna socket outlet modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. complete all as specified & directed.
Supplying and fixing 1 or 2 Module (75mm x 75mm) size/ modules, GI box alongwith modular base & cover plate for modular switche in recess etc complete all as specified & directed.
Supplying and drawing 2 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface / recessed steel/ PVC conduit complete all as specified & directed.
Supplying and drawing 1 run of UTP 4 pair CAT 6 LAN cable in the existing surface/ recessed steel/ PVC conduit complete all as specified & directed.
Supplying and laying of 8 SWG GI wire hot dip galvanised in ground/ pipe alongwith PVC armoured cables complete all as specified & directed.
Supply and installation of 100 pair size Krone connectors in MS box complete as required.
Supply and installation of 50 pair size Krone connectors in MS box complete all as specified & directed.
Supply and installation of 20 pair size Krone connectors in MS box complete all as specified & directed.
Supply and installation of 10 pair size Krone connectors in MS box complete all as specified & directed.
Supply and laying of 100 pair 0.5mm dia Jelly filled armoured copper conductor Telephone cable in shaft existing cable tray with all fixing accessories. The cable shall be as per the DOT specifications.
Supply and laying of 50 pair 0.5mm dia Jelly filled armoured copper conductor Telephone cable in shaft existing cable tray with all fixing accessories. The cable shall be as per the DOT specifications.
Supply and laying of 20 pair 0.5mm dia Jelly filled armoured copper conductor Telephone cable in shaft existing cable tray with all fixing accessories. The cable shall be as per the DOT specifications.
Supply and laying of 10 pair 0.5mm dia Jelly filled armoured copper conductor Telephone cable in shaft existing cable tray with all fixing accessories. The cable shall be as per the DOT specifications.
Supply and fixing of Data outlet (RJ45) with anodised GI box with front plate complete all as specified & directed.
Supplying, installing, testing and commissioning of 24 port Cat 6 patch panels available with block of four equipped with tool less IO, Rack Mountable. 19" Modular Patch Panel, loaded CAT6 U/UTP 24 port LCS2 rack mountable to be compatible in 4nos of 6 X RJ 45 Tool less connector U/UTP unit in a block complete all as specified & directed.
Supply and fixing of 100X38mm wall mounted PVC Raceway for running LAN Wires/ Telephone wires with all accessories such as bends/ Couplers and fixing accessories complete all as specified & directed.
Supply and laying of 80 mm dia. Class "B" GI pipes laid 600 mm below ground level including excavation, back filling etc. complete all as specified & directed.
M&L for taking out split type AC/Window type AC complete indoor and outdoor unit from any height of building by including pumping down the gas into the compressor by controlling the suction and discharge valves , disconnecting the suction and discharge copper piping and deposit to MES store complete all as specified and directed.
M&L for refixing of split type AC complete indoor and outdoor unit at any height of building by including including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas R32/R410 including re-connection of Electric Connections, functioning AC complete in all respect and Testing, complete all as specified and as directed.
M&L for refixing of window type AC complete unit at any height of building by including including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas R32/R410 including re-connection of Electric Connections, functioning AC complete in all respect and Testing, complete all as specified and as directed.
S&F AC stand suitable for wall mounted out door AC unit up to capacity of 2 ton, necessary 40x40x6mm angle iron including fixing arrangements like welding, fabrication and nuts & bolts etc. upto six stories building complete all as specified and as directed.
Supplying, fixing and testing extra refrigeration copper piping of soft and prime quality of min 22 SWG copper pipe (1/2 inch for suction and 1/4 inch for liquid line) suitable for 1.5 Ton split AC with class 'O' nitrile insulation, fire retardant of minimum 12 mm and pvc insulated, 3 core flexible copper conductor cable, 2.5 sqmm FRLS duly strapped together complete with fixing accessories such as supporting clamps/hungers etc. as per site condition complete all as specified and as directed.
Supply and fixing Flexible PVC with nylon braided heavy duty AC drain pipe 20 mm dia in and including supporting clamps/hungers etc. and it should be connected to the nearest rain water pipeline/drain pipe .. The item includes making holes/gaps/ chiseling in walls to pass pipes as per site requirement, refinishing on all the side with rich cement mortar to match the surrounding original finished surfaces to put the entire work in order complete all as specified and as directed.
Supplying, fixing and testing PVC insulated and PVC sheathed stranded copper conductor flexible cable FRLS, 3 core, 2.5 Sqmm, 1100 Volt grade, duly strapped with refrigeration piping complete with fixing accessories such as supporting clamps/hungers etc. as per site condition complete all as specified and as directed.
Supply, testing, installations commissioning of 1.5 TR capacity of non inverter window AC 230 volt 50 Hz single phase including proper fixing & mounting arrangements and alignment work. Suitable electrical wiring between window AC and power socket with proper termination. AC unit with energy rating of 3 star as per IS 1391 part-I initially charged with ecofriendly refrigerant of R-32/R-410 and drain pipe fixed as required with cordless remote and durecell batteries.
Supply, installation, testing and commissioning of Hi wall mounted, high efficient Split type 2 TR, Five Star rating (as per leatest rating) of BEE air conditioner of following capacity, Machines confirming to latest Indian Standards and suitable for operation on 230 Volts + 10 %, single Phase, 50 Hz AC supply with cooling capacity 5275 watt and cordless remote and durecell batteries unit shall comprise of separate Indoor and outdoor unit specified. a. Indoor (fan coil) unit shall be Wall Mounted type comprising of Fan, Two way air discharge and 2 Row Deep DX coil with finned copper tubes duly coated with anti corrision and thermally conductive coating, T-Flow Fan unit with direct drive Motor , unit shall have proper air circulating, auto mode, auto swing, anti bacteria filtering, ventilation with remote control having Cool/Fan/Dry/Auto mode, sleep mode & on/off timer with suitable thermostat and insulated & leak proof condensate base complete all as specified and as directed by EIC. . b. The outdoor (condensing unit) shall be of Corrosion resistant Galvanized powder coated or equivalent Sheet steel low vibration assembly installed on suitable vibration isolators and comprising of energy efficient hermetically sealed Rotary / Reciprocating compressor operating on R 32/ R 410a refrigerant with copper condenser coils and unit shall have proper insulated & leak proof condensate base. The units shall be installed on M.S channels, angles, flats fram welded structure of appropriate size & thicknesses duly painted with anti corrosive paint (Expoxy , welded structure and anti vibration Isolated pad complete all as specified and as directed.
Note: (i) 3 mtr Copper pipping duly coated with anticorrision and thermally conductive coating with insulation and PVC flexible copper cable of suitable size as per OEM shall be deemed including in coated rate and if more than 3 mtr copper pipping is required shall be measured and paid seperatly. (ii) Warranty of Split AC unit is 2 Years, Compressor is 10 Years and PCB/controller of is 5 Years (iii) The units shall be installed on MS angle iron frame welded structure (measured and sepatate item) with duly with anti-corrosive paint (Expoxy) and anti vibration Isolated pad. (iv) The rate should include civil work required to be executed in order to make the Airconditioning system installed & put in working condition. The item includes making holes/gaps in walls to pass duct & pipes, making zaries required for various types of drain, refregerent Civil work required to be executed in order to make the Airconditioning system installed & put in working condition. The item includes making holes/gaps in walls to pass duct & pipes, making zaries required for various types of drain, refregerent & drain water pipes/ lines in walls, floor etc. using cutter machine, including core cutting as per site requirement, refinishing on all the side with rich cement mortar to match the surrounding original finised surfaces to put the entire work in order. While crossing the wall, a heavy duty PVC pipe sleve shall be fixed of the total wall thickness & shall be finished from out with rich cement mortar & from inside with white cement. No extra will be paid for any civil work related to AC work. in walls, floor etc. using cutter machine, including core cutting as per site requirement, refinishing on all the side with rich cement mortar to match the surrounding original finised surfaces to put the entire work in order. While crossing the wall, a heavy duty PVC pipe sleve shall be fixed of the total wall thickness & shall be finished from out with rich cement mortar & from inside with white cement and painting with existing color.
Supply & fixing wall mounted Voltage Stablizer, single phase, 50 Hz AC supply with Hi & Low cut off, surge protection, High voltage protection, In-bulit thermal overload protection and ITDS, copper wound with efficiency 95% at nominal load and voltage range input voltage range 140 to 280 volts and output voltage 230 Volt ± 1%, air cooled with digital display complete all as specified and as directed by EIC of Capacity 4 KVA.
S&F AC stand suitable for wall mounted out door AC unit up to capacity of 2 ton, necessary 40x40x6mm angle iron including fixing arrangements like welding, fabrication and nuts & bolts etc. upto six stories building complete all as specified and as directed.
M&L for sheet metal enclosures with plug top and MCBs single pole and natural enclosures with two pin and earth plug and socket complete with one single pole MCB 32A capacity complete all as specified & directed.
Supply and laying in replacement XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 185 Sqmm 3.5 core including testing complete all as specified & directed
Supply and laying in replacement XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 50 Sqmm 3.5 core including testing complete all as specified & directed
Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 core 95 sq. mm. Alu XLPE size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade complete all as specified & directed.
Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 core 185 sq. mm. Alu XLPE size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade complete all as specified & directed.
Design, fabrication, assembling, wiring, supply installation, testing and commissioning in replacement of LT panel, suitable for outdoor installation, factory fabricated out of CRCA sheet steel 2mm for non-load bearing members and 3.15mm for load bearing members in cubicle formation, compartmentalized, from 3b construction & IP-65 in acc. with IEC 60529 protection, free standing floor mounted, dust and vermin proof with reinforcement of suitable size angle iron, channel, `T’ sections and / or flats wherever necessary with extensible type TPN aluminum alloy bus bars of high conductivity, DMC/SMC with supports with short circuit withstand capacity of 31 MVA for 1 sec. Panel shall have a common copper earth bar with 2 nos. earth stud. 3 mm thick cable gland plates shall be provided on top as well as at the bottom of the panels with anti-condensation space heater. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. 2 Nos. earthling terminals shall be provided for all distribution panels. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZ supply system duly internal wiring with pvc insulated FRLSH multistranded copper conductor cable of suitable size and copper thimble etc.. Lifting hooks shall also be provide din case of large panels. Approval shall be taken for panel in the form of shop drawings before fabrication. Galvanized hardware's with zinc passivation shall be used in fabrication of panels in and including of taking out old us panel. Panel shall be consisting with following:-
Incomer : 250 Amps, 35KA, 4P EDO type Microprocessor based MCCB with ON/OFF/TRIP indicating lamps with MCB's and over current, short circuit and earth fault releases - 1 No. Bus-Bar : 400 Amp, 50 KA, 3 Phase and Neutral Copper bus bars of high conductivity electrolytic quality aluminum alloy with colored heat shrinkable insulated sleeve.-1 Set. Instruments : Multifunction Meter including CT's of suitable size- 1 set. RYB phase indicating lamps LED type controlled by, MCB-1 Set Outgoing : 100 Amp 3TPN MCCB,16kA with RYB phase indicating lamps LED type controlled by, MCCB - 03 Nos Note: * All MCCB above 200A shall have microprocessor release unit with s/c, o/c & e/f protection. ( ICS as 100% ICU ) * All MCCB up to 200A shall be Thermal agnatic release unit with s/c & o/c protection.( ICS as 100% ICU) * All MCCB/MPCB shall be digital VAF Meter with CT's, LED type ON,OFF & TRIP indicating lamps and operating handle. * All MCB shall be 10kA with 'C' Curve . * All MPCB shall be Type '2' Co-ordination and having s/c, o/c & s/f protection
Material and Labour for earthing complete with GI plate electrode 600mmx600mmx6mm thick buried in ground vertically to a depth not less than 2.5meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with GI earth strip 25x4mm by means of nuts, bolts and washers. GI strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) as shown in electrical plat No. 05 of SSR Part-I with following:- (a) GI strip 25 x 4 mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embedded in floor of PCC earth pit. (Funnel should properly tightened on GI watering pipe and embedded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick re-enforced with 8mm dia bars 75mm centre to centre both ways with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
Supply and laying 25 mm x 4 mm GI strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50mm)
Excavation in trenches in Soft/Loose/Hard/Dense soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables etc. complete all as specified and as directed .
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed .
Removal of excavated material [soil] to a distance not Exc 50m and depositing where directed at a level not exc 1.5m above the starting point where directed complete all as specified & directed.
M&L for laying reinforced concrete pipes for cable protection, class NP2 of dia 100 mm, 2 nos half round (for bottom and top) and before laying excavated area shall be leveling complete all as specified & directed.
Supply and laying GI pipe medium grade ISI marked including all fittings in trenches/ wall/ floor of sizes 40 mm bore including taking down old unserviceable pipe & jointing etc. complete all as specified and directed.
Supply and laying GI pipe medium grade ISI marked including all fittings in trenches/ wall/ floor of sizes 50 mm bore including taking down old unserviceable pipe & jointing etc. complete all as specified and directed.
S&F in replacement Float valve with epoxy coated aluminium rod and high density ball of size 40 mm bore dia incl replacement of existing reducer/nipple of any size complete all as specified and directed.
S&F in replacement gun metal gate valve with iron wheel head screwed both ends for iron pipe , ISI marked , as per IS : 778 of size 40 mm bore dia incl replacement of existing reducer/nipple of any size complete all as specified and directed.
S&F in replacement gun metal gate valve with iron wheel head screwed both ends for iron pipe , ISI marked , as per IS : 778 of size 50 mm bore dia incl replacement of existing reducer/nipple of any size complete all as specified and directed.
S&F in replacement of old unserviceable rotational moulded polythelene water storage tank (cylindrical vertical with closed top) triple layer of capacity 5000 ltrs hoisted & fixed in position incl all fittings (i.e water tank connector/flange/nipple etc) complete all as specified and directed.
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe 100 mm dia conforming to IS 3589/IS 1239 including welding fittings like elbows, tees, flanges, tappers, nuts bolts, gasketse etc. and fixing the pipe on the wall/ceilling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as all as specified & directed.
Supply and fixing single headed internal hydrant valve with instantaneous stainless steel coupling of 63mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A ) with blank Stainless steel cap and chain complete as all as specified & directed.
M&L for Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glass door frame made of 16 gauge MS sheet duly painted fire red out side and brilliant white inside yard complete all as specified & directed.
S&F 63 mm dia instantaneous pattern SS (Stainless Steel) Short branch pipe, 20 mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete all as specified & directed
S&F Non-percolating rubber reinforced lined fire hose pipe (as per IS : 636) Type-A of 63 mm dia and length as described below. The hose shall be rated for burst pressure of 35.7 Kg/Sqcm. Hose shall be complete with ISI marked SS male & female coupling (IS:903)15mtrs length. (For Internal Hydrant & External Hydrant) complete all as specified & directed.
Providing, installation, testing and commissioning of non-return valve 100mm dia of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc as required complete as all as specified & directed.
Supplying and fixing, testing & commissioning of double flanged sluice valve 100mm dia of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required complete as all as specified & directed.
Supply and fixing first aid hose reel 40m with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required:- (a) 20mm nominal internal dia water hose thermoplastic (Textile reinforced ) type-2 as per IS : 12585 (b) 20mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipments on wall. Connections from riser with 25mm dia stop gun metal valve and MS pipe and socket.
S&F Pressure gauge 4"dial 0-14 kgs rating complete all as specified & directed.
S&F Pressure switch, pressure range: 2 Bar to 14 Bar rating complete all as specified & directed.
M&L for mild steel work MS sheet, angle iron, flat iron etc including cutting, welding,complete all as specified and directed.
Supply and fixing welded to flanges on ends for GI/MS pipe of dia 100 mm & welded flange of suitable size for making connection to internal hydrant landing valve, flange not less than 15mm thick complete all as specified and directed.
Laying and fixing of one number XLPE power cable of 1.1 KV grade of size upto 35sqmm 3.5 core on wall/duct clamped with 1mm thick saddle complete all as specified and directed.
S&F air vessel made of 250mm dia, 8mm thick MS sheet, 1200mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.
Supplying, installation, testing and commissioning of electric driven pressurisation pump of 450 lpm at 35 m Head suitable for automatic operation and consisting of following, complete in all respects, as required : (Terrace Pump) (a) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. (b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. (c) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads
Supply, installing, testing and commissioning factory fabricated and tested LT outdoor type panel, platform mounted, of suitable size for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Aluminium bus bars TPN of capacity 100 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, and made out of 3.15 mm thick CRCA mild steel sheet and mild steel & Mounting Channel frame work made out of angle iron of size 40 mmX5 mm ), front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade. The scope of work also comprising of the following:-
OUTGOINGS :- Star Delta Starter 7.5 HP Each having the following :- 1 No. ( Terrace Pump ) (a) MCB 32 A 10 KA 3 Pole C Curve- 01 No (b) Contactor 18 A TP (Main & Delta) - 02 Nos (c) Contactor 12 A TP (Star) - 01 No. (d) B1 Metal Over Load relay 6-10 A - 01 No. (e) Star delta timer Micon Series - 01 No. (f) Digital Amp Meter (0-30A) - 01 No. (g) CT 30/5A - 01 No. (h) Single Phase Preventer - 01 No. (i) Push button Start/Stop with Elements - 02 Nos, (j) On, Off, Trip indicating Lights LED type 220 V AC- 1 Set. (Set of three). (k) Aux. Blocks 1 No+1 Nc - 1 Set. Notes : 1. Provison for Auto/Manual Mode incase of Auto failure 2. Control circuit for Pressure Maintain via Pressure Switch
Mohit Infratech (BID ID -3505524)
Vinay Shankar (BID ID -3502068)
GRID ENGINEERS (BID ID -3501806)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
Tdr.pdf
Tender Documents • 1.56 MB
BOQ_830635.xls
BOQ • 1.88 MB
Download all tender documents and submit your bid