SPL REPAIR FOR REPLACEMENT OF UNSERVICEABLE/ BER SPLIT AC AT SAA UNDER GE (S) TEZPUR
2026_MES_777215_1
9169
Open Tender
Civil Works
210 days
GE South Tezpur
as per NIT
4 documents required · 4 mandatory
₹500
GE South Tezpur
₹84,900
Yes
8 Jul 2026
8 Jul 2026
1 Aug 2026
8 Jul 2026
29 Jul 2026
22 Jul 2026
8 Jul 2026 - 15 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, install, testing & commissioning of hi wall, split-type Air Conditioner Unit of capacity 1.5 TR based on Inverter Technology comprising of indl indoor & outdoor units complete with cordless remote control unit & with in-built air ionizer & plasma filter for better indoor air quality with minimum 5 star rated incl electric connection complete all as specified and directed.
NOTE :
(i) The Air Conditioner shall be initial filled / charged with refrigerant of specified quantity & the refrigerant to be used shall of Non-CFC type & as per the latest technology.
(ii) The cost of additional refrigerant pipes required (if any) is deemed to be included in the unit quoted rates.
(iii) Suitable piping of adequate length & size 5/8" for drainage of condensate water from indoor unit shall be provided & the cost of the same is deemed to be included in the unit quoted rates.
(iv) Anything missed out in the technical specifications but technically required for efficient working of the AC is deemed to be included in the unit quoted rates. | 48 | Each | - | - |
| 2 | Supply, install, testing & commissioning of hi wall, split-type Air Conditioner Unit of capacity 2.0 TR based on Inverter Technology comprising of indl indoor & outdoor units complete with cordless remote control unit & with in-built air ionizer & plasma filter for better indoor air quality with minimum 5 star rated incl electric connection complete all as specified and directed.
NOTE :
(i) The Air Conditioner shall be initial filled / charged with refrigerant of specified quantity & the refrigerant to be used shall of Non-CFC type & as per the latest technology.
(ii) The cost of additional refrigerant pipes required (if any) is deemed to be included in the unit quoted rates.
(iii) Suitable piping of adequate length & size 5/8" for drainage of condensate water from indoor unit shall be provided & the cost of the same is deemed to be included in the unit quoted rates.
(iv) Anything missed out in the technical specifications but technically required for efficient working of the AC is deemed to be included in the unit quoted rates. | 5 | Each | - | - |
| 3 | M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 4.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 4.0 Sqmm as earth lead drawn into rigid non metalic PVC conduit of size 20 mm dia including all fittings complete all as specified and as directed.
Note:- Two runs of 4 Sqmm conductor as main wire and one run of 4 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit. | 246 | RM | - | - |
| 4 | Supplied & fixed Single pole and neutral enclousure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps.complete all as specified and directed. | 41 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
Tenderdocus.pdf
Tender Documents • 1.29 MB
BOQ_870436.xls
BOQ • 0.50 MB
Addldocus.pdf
Additional Documents • 0.16 MB
Download all tender documents and submit your bid