Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L1 | Accepted-AOC Being Lowest | |
| 2 | Rejected-Technical 26 740 35 KESARI HOUSE NEAR RICO INDUSTRIAL AREA DEVIPURA SIKAR RAJASTHAN 332 001 | SIKAR | SIKAR | RAJASTHAN | 332001 | - | Rejected-Technical Due to Catagory not available | |
| 3 | Rejected-Technical | - | Rejected-Technical Due to Catagory not available | |
| 4 | Rejected-Technical | - | Rejected-Technical Due to Catagory not available | |
| 5 | Rejected-Technical | - | Rejected-Technical Due to adverse remark in WLR |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
27 Dec 2023, 6:00 pmClosed
CWE AF JODHPUR
HQ CWE AF JODHPUR 342011
PROVN OF 33KV RMU FOR INTERCHANGING STANDBY CABLE IN 33KV FEEDER AT AFS JODHPUR
2023_MES_615418_3
86038/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF JODHPUR
As per NIT
8 documents required · 8 mandatory
₹500
GE AF JODHPUR
₹58,000
Yes
22 Mar 2024
5 Dec 2023
3 Jan 2024
5 Dec 2023
27 Dec 2023
13 Dec 2023
Amount
Supply,installation,testing & commissioning of 33 KV,630A,25kA/1s, Outdoor(IP54) type non-extensible 3-way Ring Main Unit floor mounted with internal copper bus bars, consisting of 3 nos. fixed Motorized Load Break Switch having basic insulation level 70KV(RMS) and 170KV (Peak). All live parts, bus bars, LBSs connections of RMU should be enclosed in a tank , sealed for life robotically welded non magnetic and non ferrite grade stainless steel tank Grade 304 of minimum 2 mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The Unit shall be tested with Short time Fault Current Rating of 25kA for 1 sec. The complete unit should be type tested for internal arc of 25KA of 1 sec with AFLR classification. The unit shall have front cable entry for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown.RMU should be complete with all accessories such as touch proof Termination kits suitable for maximum 1Rx3Cx300sqmm Cable (shall be deceided during detailed engineering) ;VPIS; FPI in all the feeder, cable supports, all front cable terminations, mechanical indications for Load break switch ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694 . 230VAC supply shall be provided at site by purchaser. OEM shall provide necessary arrangement of Battery Charger with 24 volt DC minimum 26AH capacity inside the RMU to convert this 230VAC into control voltage 24V DC for spring charge mechanism as per OEM's RMU design.Supply of Touchproof termination kits as per above cable size and its termination at site shall be in RMU OEM Scope only to avoid any commissioning errors.Also,supervision of commissioning of this RMU shall be in RMU OEM Scope to avoid any hassles and ensure smooth charging of the RMU.
Supply, Laying & testing cable XLPE insulated screen PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with strandard aluminium conductor 33 KV grade of size 3 core 300 sqmm complete.
Supply, Laying Galvanised pipe, light grade 150 mm dia for cable protection complete.
S & F cable jointing kit for 33 KV grade cable for out door termination Heat shrink type joint complete jointing material & accessories suitable for 3 core XLPE armoured aluminium condctor of size 240 to 400 sqmm complete.
S & F cable jointing kit for 33 KV grade cable for in door termination Heat shrink type joint complete jointing material & accessories suitable for 3 core XLPE armoured aluminium condctor of size 240 to 400 sqmm complete.
Material & labour for earthing complete with copper earth electrode 60cm x 60cm x 3.15 mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including copper strip earth lead 20*3 mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil, PCC (1:3:6) Type C1 in earth pit chamber, precast RCC cover 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note :- The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 Metres. copper strip beyond 7.5 Metre shall be measured and paid for separately.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .