Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.2 LAccepted-Finance | ₹2.2 L | 1 | Accepted-Finance L1 |
| 2 | 2₹2.3 L+₹6,100 (2.73%)Rejected-Finance OPPOSITE VIPUL GAS AGENCY HOSPITAL ROAD SOLAN H P | SOLAN | SOLAN | HIMACHAL PRADESH | ₹2.3 L+₹6,100 (2.73%) | 2 | Rejected-Finance L2 |
| 3 | 3₹2.4 L+₹16,450 (7.36%)Rejected-Finance | ₹2.4 L+₹16,450 (7.36%) | 3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | ROYAL ENGINEERING WORKS L2 | thakur lalit L3 | M/S THAKUR ELECTRICAL & HARDWARE STORE L1 |
|---|---|---|---|---|---|---|
| 1.00 | Providing main switch with HRC fuses of Standard/ Havells make and having 100 Amp capacity operational rating as per IS: 4064-1978 with upto date amendements and to the entire satisfaction of the Engineer-in-charge. | 1 | Each | 17,500 ₹17,500 | 19,500 ₹19,500 | 17,000 ₹17,000 Lowest |
| 2.00 | Providing starter of MEI/ Capital/Bentex make for 60HP motor as per IS: 8544-1979 with upto date amendements suitable for motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS: 1248 (P-V)-1983 with upto date amendments. | 2 | Each | 43,000 ₹86,000 | 45,000 ₹90,000 | 42,000 ₹84,000 Lowest |
| 3.00 | Providing and fixing sheet metal bubar chamber suitable for 200 Amp 415 volgts capacity with 4 No coppeer strip bubar each of length 1200 and croos- section aera enclosure made 1.6mm thick MS sheet having overall dimension (1200mmx500mmx200mm) nominal with all accessories including connections, earthing the body etc. as required and to the enitre satisfaction of the Engineer-in-charge. | 1 | Each | 14,500 ₹14,500 | 15,500 ₹15,500 | 14,000 ₹14,000 Lowest |
| 4.00 | Providing and fixing copper thimble 50mm2, 25mm2, 16mm2 to panel board Kit kat starter main switch etc. complete in all respect | 1 | Each | 19,500 ₹19,500 | 20,000 ₹20,000 | 19,000 ₹19,000 Lowest |
| 5.00 | Providing and fixing three core copper cable 16mm2 of Anchor/Kent make from kit kat to panel board and to the entire satisfaction of the Engineer-in-charge. | 28 | P/Mtr | 1,650 ₹46,200 | 1,700 ₹47,600 | 1,600 ₹44,800 Lowest |
| 6.00 | Providing and fixing single core copper cable 25mm2 of Anchol./ Kent make for panel to starter to main switch and to the entire satisfaction of the Engineer-in-charge. | 35 | P/Mtr | 820 ₹28,700 | 830 ₹29,050 | 800 ₹28,000 Lowest |
| 7.00 | Providing and filling transformer oil tested upto 1100 volts | 20 | P/Litr | 310 ₹6,200 | 320 ₹6,400 | 300 ₹6,000 Lowest |
| 8.00 | Providing and fixing current transformer 200/5 of Standard make | 3 | Each | 3,700 ₹11,100 | 4,000 ₹12,000 | 3,600 ₹10,800 Lowest |
Tender Value
₹2.1 L
EMD Value
₹4,260
Closing Date
25 Jul 2026, 11:00 amClosed
Executive Engineer
Jal Shakti Division Bilaspur
Restoration of Rain Damage LWSS Shira Sandholi in Tehsil Sadar District Bilaspur (SH Providing and fixing main switch starter and copper cable etc).
2026_HPIPH_139032_5
BLP-BLP-0736-NIT No. 5628-5729 Dated 14/07/2026
Open Tender
Civil Works
Item Rate
30 days
Sub Division Bilaspur Section Bilaspur
Please refer Tender documents.
4 documents required · 4 mandatory
₹350
₹4,260
12 Aug 2026
16 Jul 2026
25 Jul 2026
16 Jul 2026
25 Jul 2026
16 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing main switch with HRC fuses of Standard/ Havells make and having 100 Amp capacity operational rating as per IS: 4064-1978 with upto date amendements and to the entire satisfaction of the Engineer-in-charge. | 1 | Each | - | - |
| 2 | Providing starter of MEI/ Capital/Bentex make for 60HP motor as per IS: 8544-1979 with upto date amendements suitable for motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS: 1248 (P-V)-1983 with upto date amendments. | 2 | Each | - | - |
| 3 | Providing and fixing sheet metal bubar chamber suitable for 200 Amp 415 volgts capacity with 4 No coppeer strip bubar each of length 1200 and croos- section aera enclosure made 1.6mm thick MS sheet having overall dimension (1200mmx500mmx200mm) nominal with all accessories including connections, earthing the body etc. as required and to the enitre satisfaction of the Engineer-in-charge. | 1 | Each | - | - |
| 4 | Providing and fixing copper thimble 50mm2, 25mm2, 16mm2 to panel board Kit kat starter main switch etc. complete in all respect | 1 | Each | - | - |
| 5 | Providing and fixing three core copper cable 16mm2 of Anchor/Kent make from kit kat to panel board and to the entire satisfaction of the Engineer-in-charge. | 28 | P/Mtr | - | - |
| 6 | Providing and fixing single core copper cable 25mm2 of Anchol./ Kent make for panel to starter to main switch and to the entire satisfaction of the Engineer-in-charge. | 35 | P/Mtr | - | - |
| 7 | Providing and filling transformer oil tested upto 1100 volts | 20 | P/Litr | - | - |
| 8 | Providing and fixing current transformer 200/5 of Standard make | 3 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.31 MB
PWD8.pdf
Tender Documents • 1.32 MB
Termsandconditions.pdf
Tender Documents • 0.17 MB
BOQ_205943.xls
BOQ • 0.23 MB
PWD6.pdf
Tender Documents • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .