Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC 2 NEAR ASHOKA PLAZA DELHI ROAD ROHTAK ROHTAK HARYANA 124001 | ROHTAK | HARYANA | 124001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹34.8 L+₹4.0 L (13.0%)Rejected-Finance | L2 | Rejected-Finance Highest | |
| 3 | Rejected-Technical 315 INDUSTRIAL AREA II PANCHKULA 134113 | PANCHKULA | HARYANA | 134113 | - | Rejected-Technical Rejected |
Tender Value
Refer Docs
EMD Value
₹74,520
Closing Date
8 Dec 2020, 5:00 pmClosed
Ritesh Nandal
Executive Engineer, Electrical Division, PWD B and R Br., Ambala Cantt.
Up-gradation of Civil Hospital from 200 Bedded to 300 bedded Ambala City in Ambala Distt. (Pdg. LAN and EPABX System).
2020_HRY_151707_1
PWD/Elect-KNL/Elect-AMB/110126
Open Tender
Construction Works
Works
60 days
Ambala Cantt
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
₹74,520
9 Mar 2021
25 Nov 2020
9 Dec 2020
25 Nov 2020
8 Dec 2020
25 Nov 2020
Amount
SITC of 24 Port Layer 2 Access switch Make:Cisco, Allied, Extreme Network, ZYXEL/Alcatel/Juniper a) 24x1G SFP/T Ports loaded with suitable modules of equivalent make. b) 4x1G/10G SFP+ Slots Should support switching fabric of 288Gbps or more Should support min forwarding rate of 214 Mpps Two or more Switches in stack should be capable to operate as one logical L3 Virtual switch with synchronisation of L3 & L2 protocols for higher availability with stacking bandwidth of min 40Gpbs per switch expandable to 160Gbps. Switch should be supplied with required stacking cables Core Switch will be equipped with two core switches in HA mode which should operate as logical one L3 Switch The connected servers or switches should be dual homed to core switches using standard LACP for automatic load balancing and high availability Should equipped with internal redundant power supplies Should support Unidirectional Link Detection (UDLD) or equivalent to detect unidirectional links caused by incorrect fibre optic wiring or port faults and disable on fibre optics interfaces Should support ITU-T G.8032 for sub 50ms ring protection/Equivalent. Support 802.1D, 802.1S, 802.1w, Rate limiting Support 802.1X Security standards Support 802.1Q VLAN encapsulation, IGMP v1,v2 and v3 snooping, MLD snooping Support up to 4096 VLANs Support IGMP Snooping and IGMP Querying Should support STP, RSTP, MSTP Should support Static routing, Support RIP for IPv4 and RIPng for IPv6 Support OSPFv2 for IPv4 & OSPFv3 for IPv6 Support BGP for IPv4 & IPv6 Support PIM for IPv4 SM, DM and SSM, PIMv6-SM, IEEE 802.3az Support VRRP for IPv4 & VRRPv3 for IPv6 Support IPV4 & IPV6 dual stack Should Support 802.1Q Tagged VLAN, port based VLANs and Private VLAN Should Support IEEE 802.1v VLAN classification by protocol and port Should Support IEEE 802.1ad Provider bridges (VLAN stacking, Q-in-Q) Should Support dynamic VLAN Registration or equivalent Should Support VLAN trunking or equivalent, IEEE802.1ac Switch needs to have a console port for management via a console terminal or PC Must have support SNMP V1, V2 and V3 Should support 4 groups of RMON Should have accessibility using Telnet, SSH, Console access, easier software upgrade through network using TFTP etc. Configuration management through CLI, GUI based software utility or using web interface, USB interface for configuration backup Support SNMPv6, Telnetv6 and SSHv6, DHCPv6 relay, DHCPv6 client, NTPv6 client and server, Support NTP/SNTP Support be supportable to SDN openflow v1.3 for future requirements. Switch should support simplified network management features such as auto backup, auto upgrade, auto-provisioning and auto recovery with easy centralized management solutions. Should support ACLs, VLAN ACL's Support DHCP snooping, IP source guard and Dynamic ARP Inspection (DAI), Support MAC address filtering and MAC address lock-down, Support Tri-authentication: MAC-based, web-based and IEEE 802.1x, Support DHCPv4 (server, relay and client Support sflow, Port mirroring Operating Temperature- 0-50C
SITC of Layer-3 Switch specs Make: Cisco/Juniper/Extreme Networks, ZYXEL/Alcatel/Allied Switch should have atleast 24x10/100/1000 Base-T port, 4x100/1000 SFP Port should work simultaneously along with 24 Nos of 1G Base T port and dedicated 4x10G SFP+ Ports, 1x USB port for external USB flash from day1. Switch should have scalable to support 2x40G QSFP+ Port for future requirement Switch should have atlest 284 Gbps switching bandwidth and 220 Mpps forwarding rate. Switch should support minimum 85K Mac address. Switch should support min 4000 Active VLAN. Switch should support min 40 Gbps or more stacking bandwidth and it can stack up to 8 unit per stack. Required 1M Stacking cable from Day 1. Switch should support IEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast Ethernet, IEEE 802.3ab 1000BASE-T Gigabit Ethernet, IEEE 802.1ba, IEEE 802.3x full-duplex flow control Switch switch support IEEE 802.1D Spanning Tree Protocol, IEEE 802.1W Rapid Spanning Tree Protocol, IEEE 802.1S Multiple Spanning Tree Protocol, IEEE 802.3ad static or dynamic link aggregation (LACP), G.8032, IEEE P802.1Qaz Switch should have minimum1GB DRAM and 3GB Flash or more. Switch should support 10K IPv4 route and 6K IPv6 route. Switch should support Static, RIP, RIPng, OSPF, BGP, ISIS. Should have Static, RIP, RIPng, PBR, VRRP from day 1. Should support MPLS for future requriement. Should support Private VLAN , 802.1Q and 802.1v, IEEE 802.3ah, WRED Switch should have QOS-atleast 8 nos of 802.1p Priority Queues per port and Q-in-Q from day 1. Switch should have IGMP Snooping, , MLDV1/MLDv2, IGMPV1/v2/v3 from day 1. Switch should support Jumbo Frame Support (up to 9 KB) Switch should support NetFlow/IPFIX/sFlow or equivalent for flow exports and should support SDN with OpenFlow, IEEE 802.1Qbb. Switch should support DHCP client function,Port mirroring (many-to-one), Application Telemetry, Auto denial-of-service (DoS) prevention Following in-band management methods shall be available: Web based management (On http or https), SSH based management (SSH v2). Following out-of-band management methods shall be available: Console port and Out of Band Management 1000 Base-T Ethernet Port. AAA using RADIUS/TACACS+ must be available The switch should support SNMP V2c and V3. Syslog shall be supported with multiple syslog destinations for Log Management. Time synchronization using Network time protocol must be available. Switch should support 64 load sharing trunks, up to 16 members per trunk. Switch Should support RMON 4 Group. Mean time between failures (MTBF): 275,000 hours The switch shall have feature of backing up the configuration & restoring a backed- up configuration. Multiple Configuration files must be supported. The switch shall support multiple administrator accounts. Each administrator account shall be configurable with the desired level of management privileges. Each switch should support Redundant Hot swappable power supplies and FAN module. Switch should have Modular Operating system. Operating temperature: 32° to 122°F (0° to 50° C) Storage temperature: -40° to 158°F (-40° to 70° C) Operating humidity: 10% to 95% maximum relative humidity, non-condensing Certifications:- FCC CFR 47 part 15 Class A, EN 55032 Class A, RoHS, WEEE, EN 55024, UL 60950-1, EN 60825-1Class 1, CB, EN 300386, CSA 22.2 No. 60950 -1, FCC 21CFR, EN 60950 -1 All the switches, the fiber modules should be from the same OEM for seamless integration with existing running network and infrastructure. The OEM should have 24x7 TAC center with L1, L2 and L3 Support. OEM should have India toll free number reflected on official website. Switch should have 2 Year NBD 24x7 Tac support.
Supply Installation, testing and commissioning of 24-port loaded 1 U Height Cat6 Modular Jack Panel with integrated rear cable management tray(For Data UTP Field Cables). jac As per specification. Make & Model: R&M/AMP/Molex.
Supply Installation Testing & Commissioning of Cat6 UTP Information Outlet -Blue (Data). Should be PCB free and Tool less will be added advantage with halozn free. User Side. As per specification. Make & Model: R&M/AMP/Molex.
Supply Installation Testing & Commissioning of 2-port with dust cover faceplate including back box and all other accessories As per specification. Make & Model: R&M/AMP/Molex.
Supply Installation Testing & Commissioning of Cat6 Patch Cords - 1Mtr -Blue ( Data Rack Side), As per specification. Make & Model: R&M/AMP/Molex.
Supply Installation Testing & Commissioning of Cat6 Patch Cords - 2Mtr -Blue ( Data Field Side), As per specification. Patch cord should have provion of lock with information outlet port. Make & Model: R&M/AMP/Molex.
Supply Installation, testing and commissioning of Indoor soft jelly filled SINGLE MODE 6 CORE - OS2 . Should be ISO.IEC 11801 type OS2 and ITU-T REC G 652D. Tube Idenification :Single tube. Fibre protection (Tube) : Polybutylene Terephthalate (PBT). Water Blocking :Thixotropic Gel (Tube) and Petroleum Jelly (Interstices) with cotton poly thread protective. Core Wrapping : Polyethylene Terephthalate with cotton paper guard protection : Corrugated Steel Tape Armour (ECCS Tape). Strength Member: soft protetective periphery /Central S. Sheath : UV Stabilized Polyethylene (HDPE). Maximum. Tensile Strength-Short Term : 400N or better. Mass (Nominal) : minimum 50 kg/km Optical fiber cable with jelly filled 6F Loose Tube ( Unitube ) Type CSTA SM FOR SERVER ROOM to Each Network Rack Backbone connectivity As per specification. Make & Model: R&M/AMP/Molex.
Supply Installation Testing & Commissioning of 12F, 1U, LC OM3, LIU Loaded with Pigtails, Splice tray, LIU have slider channel for rack mount. It has spindle with fiber management accessories. As per specification. Make & Model: R&M/AMP/Molex.
Supply Installation, testing and commissioning of PATCH CORD LC-LC MM/SM OS2 DUPLEX LENGTH- 2mtr. It has covered with metal outer sheath for antirodent protection.As per specification. Make & Model: R&M/AMP/Molex.
Supply Installation & Commissioning of 9U Rack for Network Switch with all necessary accessories, civil, electrical works & peripheral items. Make & Model: Valrack/Netrack/Comrack.
Supply, installation, testing and commissioning of 1 KVA online UPS with 2 hours backup Make- Microteck, APC, Luminous
Supply and erection of 1000-Base SM SFP fiber module of same OEM quoted for switch
Supply Installation Testing & Commissioning of 3 Core Power Cable 1.5 sqmm. Make: Finolex/Polycab/Havells
Splicing and testing of fiber core with digital report of OFC performance.
SITC of 24 Port Layer 2 Non-POE Access switch Make: Cisco/Alied/Extreme Networks/ ZYXEL/Alcatel/Juniper Switch should have 24-port 10/100/1000 Base-T (Auto Uplink on all ports) and 1x USB port for external USB flash Switch should have 4-Port 100/1000 SFP slots/Ports should work simultaneously along with 24 Nos of 1G Base T port Switch should have Minimum 65Gbps Switching Capicity and 50 Mpps Forwarding rate. Switch should support min 16K Mac address or More. Switch should support min 2500 Active VLAN. Switch should support IEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast Ethernet, IEEE 802.3ab 1000BASE-T Gigabit Ethernet, IEEE 802.3bz, IEEE 802.1ba, IEEE 802.3x full-duplex flow control, IEEE P802.1Qaz Switch switch support IEEE 802.1D Spanning Tree Protocol, IEEE 802.1W Rapid Spanning Tree Protocol, IEEE 802.1S Multiple Spanning Tree Protocol, IEEE 802.3ad static or dynamic link aggregation (LACP), G.8032 Switch should have QOS and Q-in-Q from day 1. Switch should have IGMP Snooping, , MLDV1/MLDv2, IGMPV1/v2/v3 from day 1. Switch should support Jumbo Frame Support (up to 9 KB) SNMP v1, v2c, v3,RFC 1643 Ethernet Interface MIB, RFC1493 Bridge MIB IEEE 802.1Q Tag VLAN, IEEE 802.1v: VLAN classification by Protocol and Port, IEEE 802.1p (Class of Service), DiffServ, 8 Queue per port, Layer 2/3/4 Access Control Lists (ACLs) Switch should support static routing and PBR from day 1. Switch should support atleast 1000 Multicast entries and Ingress Access list Rules. Switch should have MAC and 802.1 X based Login, Fallback to local authentication database (MAC and Web-based methods), Access Policies for Telnet/ SSH-2/SCP-2 Switch should support MAC Address based Lockdown and Limited Learning. Switch should support DHCP client function,Port mirroring (many-to-one), Application Telemetry, Auto denial-of-service (DoS) prevention Following in-band management methods shall be available: Web based management (On http or https), SSH based management (SSH v2). Following out-of-band management methods shall be available: Console port and Out of Band Management Ethernet Port. AAA using RADIUS/TACACS+ must be available Syslog shall be supported with multiple syslog destinations for Log Management. Shall support Netflow/ IPFIX/ sflow or equivalent for flow exports. Time synchronization using Network time protocol must be available. Switch Should support RMON 4 Group. Mean time between failures (MTBF): 500,000 hours Operating temperature: 32° to 113°F (0° to 45° C) Storage temperature: -40° to 158°F (-40° to 70° C) Operating humidity: 10% to 95% maximum relative humidity, non-condensing Certifications:- FCC CFR 47 part 15 Class A, EN 55032 Class A, RoHS, WEEE, EN 55024, UL 60950-1, EN 60825-1Class 1, CE 2.0, IEC 61000-4-5 /EN 61000-4-5, IEC/EN 61000-4-11, EN 300386, IEC 62368-1 All the switches, the fiber modules should be from the same OEM for seamless integration with existing running network and infrastructure. The OEM should have 24x7 TAC center with L1, L2 and L3 Support. OEM should have India toll free number reflected on official website. Switch should have 2 Year NBD 24x7 Tac support.
Supply Installation Testing & Commissioning of Cat6 UTP Information Outlet -Blue (Data). Should be PCB free and Tool less will be added advantage with halozn free. User Side. As per specification. Make & Model: R&M/AMP/Molex.
Supply Installation Testing & Commissioning of 2-port with dust cover faceplate including back box and all other accessories As per specification. Make & Model: R&M/AMP/Molex.
Supply Installation, testing and commissioning of 24-port loaded 1 U Height Cat6 Modular Jack Panel with integrated rear cable management tray(For Data UTP Field Cables). jac As per specification. Make & Model: R&M/AMP/Molex.
Supply Installation & Commissioning of 9U Rack for Network Switch with all necessary accessories, civil, electrical works & peripheral items. Make & Model: Valrack/Netrack/Comrack.
Supply, installation, testing and commissioning of 1 KVA online UPS with 2 hours backup Make- Microteck, APC, Luminous
SITC IP-Phone with 2 SIP lines support POE and required external POE adaptor for the same.Phone has caller ID screen with call forwarding feature. Make Matrix/Alcatel/Avaya/Coral/Cisco
SITC IP-Phone with 1 SIP lines support POE and required external POE adaptor for the same.Phone has caller ID screen with call forwarding feature. Make Matrix/Alcatel/Avaya/Coral/Cisco
Supply and erection of PVC conduit pipe ISI marked (Medium) recessed in wall /ceiling etc. including cost of PVC bends, inspection box and all other material requiredto complete the job in all respect to the entire satisfaction of Engineer-in-Charge of work. HSR Items 31.40 25 mm dia HSR Items 31.44(b)
S/E/T/C of Cat-6 cable in existing PVC conduit /PVC channel complete in all respect with all labour and material required to complete the job in all respect.
sybase enterprises
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .