| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC E 06 127 236 GHOSHPARA WAR NO 4 P O P S KALYANI NADIA PIN 741235 | KALYANI | NADIA | WEST BENGAL | 741235 | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.6 L+₹6,088.63 (1.09%)Rejected-Finance GHOSHPARA WARD NO 04 P O P S KALYANI DIST NADIA PIN 741235 | KALYANI | NADIA | WEST BENGAL | 741235 | L2 | Rejected-Finance L2 | |
| 3 | L3₹5.7 L+₹7,149.95 (1.28%)Rejected-Finance E 06 41 84 GHOSHPARA WARD NO 4 P O P S KALYANI NADIA PIN 741235 | KALYANI | NADIA | WEST BENGAL | 741235 | L3 | Rejected-Finance L3 |
Tender Value
₹5.6 L
EMD Value
₹11,172
Closing Date
12 Jan 2026, 4:00 pmClosed
Chairman Kalyani Municipality
Office of the Chairman, Kalyani Municipality
CONSTRUCTION OF MUKTA MANCHA AND GREEN ROOM AT INSIDE OF BAKUL PARK, IN PART NO-191 OF WARD NO- 12, UNDER KALYANI MUNICIPALITY
2025_MAD_976001_19
KLYM/APAS/T-10/2025-2026
Open Tender
CIVIL WORKS
Percentage
45 days
Ward No-12
Please Refer Tender Document
8 documents required · 8 mandatory
₹0
₹11,172
8 May 2026
19 Dec 2025
15 Jan 2026
19 Dec 2025
12 Jan 2026
19 Dec 2025
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1.5 m Ref. Page -1, Item -2 a), PWD SOR Vol-I w. e. f. 1.11.2017
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation Back Filling in Foundation (1/5 of Excavation) Ref. Page 1, Item -3 a), PWD SOR Vol-I w. e. f. 1.11.2017
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (Payment to be made on measurement of finished quantity) Ref. Page 2, Item -4A, PWD SOR Vol-I w. e. f. 1.11.2017
Supplying and laying Polythene Sheet (150gm / Sq.M) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. Ref. Page -47, Item -3, PWD SOR Vol-I w. e. f. 1.11.2017
Cement concrete with graded jhama khoa (30 mm size) excluding shuttering In ground floor and foundation. (a) 1:3:6 proportion Ref. Page -23, Item -1a), PWD SOR Vol-I w. e. f. 1.11.2017
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (f) 25 mm to 30 mm shuttering without staging in foundation Ref. Page -43, Item -36 f), PWD SOR Vol-I w. e. f. 1.11.2017
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. Ref. Page - 42, Item 36,a; PWD SOR VOL-I w.e.f. 1.11.2017
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (a) Pakur Variety Ref. Page -15, Item -7a), PWD SOR Vol-I w. e. f. 1.11.2017
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel II. Other than SAIL/ TATA/RINL Ref. Page -43-44, Item -40 II), PWD SOR Vol-I w. e. f. 1.11.2017
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth Ref.Page -15, Item -8 a), PWD SOR Vol-I w. e. f. 1.11.2017
Ground Floor (b) In superstructure, ground floor Ref.Page -15, Item -8 a), PWD SOR Vol-I w. e. f. 1.11.2017
Wood work in door and window frame with rebate cutting, fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals) (d) Sal : Local. Ref.Page -114, Item -1d), PWD SOR Vol-I w. e. f. 1.11.2017
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (b) 32 mm thick shutters (single leaf) Ref. Page -124, Item -11 b), PWD SOR Vol-I w. e. f. 1.11.2017
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) (a) 40mm X 6mm, 250mm Length Ref. Page -140, Item -4 a) , PWD SOR Vol-I w. e. f. 1.11.2017
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (vi) 100mm. X 50mm. X 1.25mm. Ref. Page -140, Item -5 (vi), PWD SOR Vol-I w. e. f. 1.11.2017
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: (iii) 100mm long x 10mm dia. bolt. Ref. Page -144, Item -26, PWD SOR Vol-I w. e. f. 1.11.2017
Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. (a) 200mm long Ref. Page -141, Item -10 (a), PWD SOR Vol-I w. e. f. 1.11.2017
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S specification (I.S: 230/72) fitted and fixed complete: (iii) 100 mm grip x 12 mm dia rod. Ref. Page -145, Item -30 iii), PWD SOR Vol-I w. e. f. 1.11.2017
(i) Door stopper.(Brass) Ref. Page -143, Item -19 i), PWD SOR Vol-I w. e. f. 1.11.2017
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25% for each addl. floor above 4th floor) (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. Ref. Page - 104, Item 13,i; PWD SOR VOL-I w.e.f. 1.11.2017
Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only] Ref. Page - 107, Item 20; PWD SOR VOL-I w.e.f. 1.11.2017
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding / staging where necessary (Ground floor). (ii) With 1:4 cement mortar(15mm thick) Ref. Page -189, Item -1, PWD SOR Vol-I w. e. f. 1.11.2017
(ii) With 1:4 cement mortar (c) 10 mm thick plaster (ceilling)
(i) With 1:6 cement mortar (b) 20 mm thick plaster (Internal Wall)
(i) With 1:6 cement mortar (c) 15 mm thick plaster (External Wall)
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE : Cement 0.152 cu.m. per 100 sq.m. Ref. Page -192, Item -15, PWD SOR Vol-I w. e. f. 1.11.2017
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/Sq.M all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (iii) 35 mm. thick Ref. Page -48, Item -6 ii), PWD SOR Vol-I w. e. f. 1.11.2017
Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e) I Ref. Page - 66, Item 36; PWD SOR VOL-I w.e.f. 1.11.2017
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. In Ground Floor: (a) One Coat Ref. Page -196, Item -8),PWD SOR Vol-I w. e. f. 1.11.2017
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) One Coat i) Water based interior grade Acrylic Primer Ref. Page -195, Item -7), PWD SOR Vol-I w. e. f. 1.11.2017
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) a) Normal Acrylic Emulsion Ref. Page -197 Item -17), PWD SOR Vol-I w. e. f. 1.11.2017
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats Ref. Page -196, Item -10, PWD SOR Vol-I w. e. f. 1.11.2017
(a) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.. Ref. Page -200, Item -1B, PWD SOR Vol-I w. e. f. 1.11.2017
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. Ref. Page -200, Item -1 a), PWD SOR Vol-I w. e. f. 1.11.2017
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On timber or plastered surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white) Ref. Page -200, Item -2 A) a),iv) PWD SOR Vol-I w. e. f. 1.11.2017
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : b) on steel or other metal surface. With super gloss (hi-gloss) - (ii) Two coat (EXCEPT WHITE) Ref. Page -200, Item -2 A) b) ii) PWD SOR Vol-I w. e. f. 1.11.2017
Add 18% GST
Add 1% Cess
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.87 MB
Tendernotice_2.pdf
PDF • 6.58 MB
BOQ_2377263.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .