Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹34.8 L+₹1.9 L (5.76%)Rejected-Finance | L2 | Rejected-Finance Rejected being higher than L1 | |
| 3 | L3₹38.7 L+₹5.8 L (17.6%)Rejected-Finance | L3 | Rejected-Finance Rejected being higher than L1 | |
| 4 | L4₹39.5 L+₹6.6 L (20.0%)Rejected-Finance 10 MAKHAN LAL SADHUKHAN LANE PO PS BARRACKPORE KOLKATA 700120 W B | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | L4 | Rejected-Finance Rejected being higher than L1 | |
| 5 | L5₹39.9 L+₹7.0 L (21.2%)Rejected-Finance | L5 | Rejected-Finance Rejected being higher than L1 |
| Sl No | Description | Qty | Unit | TAPAS ENGINEERING CO L2 | R K CONSTRUCTION L4 | CHANDRA CONSTRUCTION & CO. L3 | SITARAM CONSTRUCTION L1 | NC BOSE AND CO L5 | BHAUMIK CONSTRUCTION L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully gear mechanism comprising of gear box, stainless steel rope ,Jubli clamp ,lever for lifting and lowering for high mast light 6/9 fittings from 15 meter long high mast and taking up after replacement unserviceable light fittings complete all as specified and as directed.
Note: - Light fitting shall be measured seperately under respective items. | 8 | Each Job | 1,200 ₹9,600 | 1,350 ₹10,800 | 1,333 ₹10,664 | 1,185 ₹9,480 Lowest | 1,300 ₹10,400 | 1,400 ₹11,200 |
| 2.00 | Supply and fix in repair 200W LED flood light made of pressure die cast aluminium housing with integrated polycarbonate IP Lens cover, IP66 protection and system efficacy should be greater than 120 Lumen per watt. Driver should be BIS approved silicon filled potted driver with inbuilt 4KV surge protection device and 10 KV surge protection device in luminare. THD shall be <10%, Power Factor >0.95, CCT 5700K and brand name should be embossed/engraved on the LED fitting for traceability till life complete all as specified and directed. | 8 | Each | 17,450 ₹1,39,600 | 18,000 ₹1,44,000 | 17,800 ₹1,42,400 | 17,000 ₹1,36,000 | 18,474 ₹1,47,792 | 16,725 ₹1,33,800 Lowest |
| 3.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth and getting out in soft/loose soil for laying of under ground cable complete all as specified and directed. | 80 | Cum | 410 ₹32,800 | 560 ₹44,800 | 486 ₹38,880 | 370 ₹29,600 Lowest | 510 ₹40,800 | 610 ₹48,800 |
| 4.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250mm in soft/loose soil, complete all as specified and directed. | 29 | Cum | 195 ₹5,655 | 345 ₹10,005 | 248 ₹7,192 | 151 ₹4,379 Lowest | 295 ₹8,555 | 395 ₹11,455 |
| 5.00 | Removing excavated materials (soils) not exc. 50 m and depositing where directed at a level not exc. 1.5 m above from starting point complete all as specified and directed. | 51 | Cum | 300 ₹15,300 | 450 ₹22,950 | 362 ₹18,462 | 261 ₹13,311 Lowest | 400 ₹20,400 | 500 ₹25,500 |
| 6.00 | Material and labour for sand cushioning with clean and dry river sand for protection of PVC cable with approved sand of uniform thickness. laid dry, filling in trenches and punning down in proper required layers complete all as specified and as directed.
Note:- Punned down thickness shall be measured for payment. | 25 | Cum | 2,150 ₹53,750 Lowest | 2,300 ₹57,500 | 2,200 ₹55,000 | 2,200 ₹55,000 | 2,250 ₹56,250 | 2,350 ₹58,750 |
| 7.00 | Materials and labour for brick protection cover to underground cables with sub class ‘B’ of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed. | 1,870 | Each | 65 ₹1,21,550 | 215 ₹4,02,050 | 115 ₹2,15,050 | 30 ₹56,100 Lowest | 165 ₹3,08,550 | 265 ₹4,95,550 |
| 8.00 | All as per item No 7.00 here in before but except brick and -ditto-.
Note: Serviceable brick shall be reused obtained from item No 3.00. | 1,745 | Each | 2.5 ₹4,362.5 | 4.5 ₹7,852.5 | 3 ₹5,235 | 2 ₹3,490 Lowest | 4 ₹6,980 | 5 ₹8,725 |
| 9.00 | Taking down / out unserviceable LT UG Cables of size 16 sqmm 4 core and connections including bricks, GI pipes, etc. of any descriptions, laid in trenches and / or fixing with walls / poles including segregating of serviceable materials viz bricks and keep in safe custody for re-use, complete all as specified and directed.
Note:- Earth work shall be measured and paid separately under respective items. | 450 | RM | 65 ₹29,250 | 215 ₹96,750 | 115 ₹51,750 | 30 ₹13,500 Lowest | 165 ₹74,250 | 265 ₹1,19,250 |
| 10.00 | Material and labour for demolition of old unserviceable foundation of pole and costruction of new PCC foundation for street light pole of existing size complete all as specified and directed.
Note: -
(a) Necessary PCC for making foundation and copping shall be measured and paid separately under respective items.
(b) The cost for making necessary arrangement for taking out pole from foundation and refixing the pole in new foundation shall be deemed included in the quoted rates. | 10 | Each Job | 1,050 ₹10,500 | 1,200 ₹12,000 | 1,155 ₹11,550 | 1,042 ₹10,420 Lowest | 1,150 ₹11,500 | 1,250 ₹12,500 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
24 Jun 2026, 6:00 pmClosed
GE AF Barrackpore
GE AF Barrackpore Post Barrackpore Dist 24 Parganas North Kolkata 700120
REPAIR / MAINT OF HIGHMAST LIGHTS, POST TOP LANTERN, PERIMETER LIGHTS INCLUDING REPLACEMENT OF CORRODED CABLE JUNCTION BOXES, REPLACEMENT OF OLD UNSERVICEABLE TIMER SWITCHES, FEEDER PILLAR BOXES FOR SECURITY LIGHT AND REPLACEMENT OF CONNECTED LT UG C
2026_MES_769474_1
8731/BKP/AF OF 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE AF Barrackpore
Class-D, Category-b(i)
2 documents required · 2 mandatory
₹500
GE AF Barrackpore
₹60,000
Yes
11 Aug 2026
3 Jun 2026
26 Jun 2026
3 Jun 2026
24 Jun 2026
17 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully gear mechanism comprising of gear box, stainless steel rope ,Jubli clamp ,lever for lifting and lowering for high mast light 6/9 fittings from 15 meter long high mast and taking up after replacement unserviceable light fittings complete all as specified and as directed.
Note: - Light fitting shall be measured seperately under respective items. | 8 | Each Job | - | - |
| 2 | Supply and fix in repair 200W LED flood light made of pressure die cast aluminium housing with integrated polycarbonate IP Lens cover, IP66 protection and system efficacy should be greater than 120 Lumen per watt. Driver should be BIS approved silicon filled potted driver with inbuilt 4KV surge protection device and 10 KV surge protection device in luminare. THD shall be <10%, Power Factor >0.95, CCT 5700K and brand name should be embossed/engraved on the LED fitting for traceability till life complete all as specified and directed. | 8 | Each | - | - |
| 3 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth and getting out in soft/loose soil for laying of under ground cable complete all as specified and directed. | 80 | Cum | - | - |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250mm in soft/loose soil, complete all as specified and directed. | 29 | Cum | - | - |
| 5 | Removing excavated materials (soils) not exc. 50 m and depositing where directed at a level not exc. 1.5 m above from starting point complete all as specified and directed. | 51 | Cum | - | - |
| 6 | Material and labour for sand cushioning with clean and dry river sand for protection of PVC cable with approved sand of uniform thickness. laid dry, filling in trenches and punning down in proper required layers complete all as specified and as directed.
Note:- Punned down thickness shall be measured for payment. | 25 | Cum | - | - |
| 7 | Materials and labour for brick protection cover to underground cables with sub class ‘B’ of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed. | 1,870 | Each | - | - |
| 8 | All as per item No 7.00 here in before but except brick and -ditto-.
Note: Serviceable brick shall be reused obtained from item No 3.00. | 1,745 | Each | - | - |
| 9 | Taking down / out unserviceable LT UG Cables of size 16 sqmm 4 core and connections including bricks, GI pipes, etc. of any descriptions, laid in trenches and / or fixing with walls / poles including segregating of serviceable materials viz bricks and keep in safe custody for re-use, complete all as specified and directed.
Note:- Earth work shall be measured and paid separately under respective items. | 450 | RM | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
Tenderdocuments8731.pdf
Tender Documents • 1.20 MB
BOQ_861717.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .