Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 LAccepted-AOC 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L1 | Accepted-AOC L1, being lowest | |
| 2 | L2₹18.3 L+₹37,480 (2.10%)Rejected-Finance RH NO 06 KARMA KSHETRA HOUSING SOCIETY SECTOR 29 PRADHIKARAN RAVET POST DEHU ROAD 412 101 | NA | NA | 412101 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹18.8 L+₹91,442 (5.12%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹19.1 L+₹1.2 L (6.60%)Rejected-Finance 213 F BLOCK MEGA MARGANPATTE HADAPSAR PUNE 411013 | PUNE | MAHARASHTRA | 411013 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹20.0 L+₹2.2 L (12.1%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
30 Sept 2024, 6:00 pmClosed
GE dehu road
GE dehu road Pune
REPAIR/MAINTANANCE OF DG SETS UNDER GE DEHU ROAD.
2024_MES_670027_1
8871
Open Tender
Civil Works
Item Rate
270 days
GE dehu road
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE dehu road
₹64,000
29 Nov 2024
2 Sept 2024
2 Oct 2024
2 Sept 2024
30 Sept 2024
16 Sept 2024
Amount
AMC FOR DG set 62.5 KVA through service agency or qualified service agency for NINE NUMBERS DG SET at various location in every month. Make: Kirlosker /Greaves Power Note:- (a)spares required for above maint will be measured and paid separately under relevent items . Scope Of Work :- (a) Engine Cooling System :-Checking of radiator conditions (check for radiator clogging, cooling fins condition, V belts, etc. Checking of K-Cool Super level, piping corrosions & any sign of radiator leaks. Checking of hoses & connections deterioration / wear & tear.Checking of hoses & connections deterioration / wear & tear.Checking of fan pulley mis-alignment / deterioration, defective bearings, corroded surface, grease condition.Checking the water pump leaks, noisy operation, abnormal vibration, impeller defects, cracked housing, worn out shaft, etc Checking of belts tension & deterioration. Checking thermostat for proper functioning. Checking water level sensor in radiator for K-Series Engines . (b) Engine Fuel System :-Checking fuel lines connections (any signs of fuel leak, loose connections, corroded piping, fuel restrictions, defective clamps, deteriorated hose, etc.).Checking governors & controls conditions (any sign of deterioration, loose connections & system malfunction/ not responding etc.).Checking governors & controls conditions (any sign of deterioration, loose connections & system malfunction/ not responding etc.) Checking actuator of electronic governing system.Checking priming pump condition.Checking fuel filter condition – replace the filters as found necessary.Checking water separator condition.Checking fuel tank condition (any sign of water contamination, no water drain, corrosions / deteriorations, etc.Checking exhaust smoke condition to identify health of the engine. ( c) Engine Lubricating System Inspection :-Checking oil lines connections (any signs of oil leak, loose connections, corroded piping, defective clamps, deteriorated hose, etc.Checking oil pressure condition (any sign of erratic operation, defective gauges, defective pressure sensors, defective wiring harness, etc.Checking oil level & oil quality condition.Checking last oil change & oil filter replacement.Checking make up oil availability at site.
(d) Engine Air Induction System :-Checking air filter indicator reading (any sign of defective sensor, erratic operation).Checking air filter (any sign of filter clogging, dirt accumulation, air obstruction, defective seal, damage/ deteriorated housing etc.Checking turbocharger condition (any sign of excessive end play, oil/ gas leak, abnormal operating noise, excessive vibration, overheating etc.)Checking hoses & connections deterioration / wear & tear.Checking Charge Air cooler condition- if any (sign of clogged core/ fins, air leaks at connections, damaged gaskets, etc. (e) Engine Exhaust System :-Checking the exhaust manifold condition (any sign of gas leak, missing bolts and nuts, red hot manifold, oil leak, deterioration etc.Checking the flexible bellow/ hoses & connections deterioration / wear & tear.Checking muffler condition (any sign of support insufficiency, corrosion, drain pipe valve not installed, not shielded, etc).Checking exhaust pipe insulation condition / deterioration.Checking smoke emission quality (any sign of excessive black smoke, bluish smoke, white smoke, restricted gas flow etc. (f) Engine Electrical System :-Checking batteries condition (electrolyte level, distilled water level, defective plate, voltage drop during cranking-refer to manufacturer acceptable voltage drop, etc..), Battery capacity evaluation this can be done by battery discharge test. Replacement of batteries is to be planned.Checking the starting motor condition (any sign of defective solenoid, defective brushes, grounded / shorted connection, struck up rotor etc.Checking the wiring harness condition (any sign of defects, grounded, loose connections, shorted, open circuit, any deterioration. (g) Generator Control Panel System Inspection :- Checking “start / stop / manual switch condition & functionality.Checking “voltmeter”, “Ammeter”, “frequency “ meter for proper functionality.Checking “voltmeter”, “Ammeter”, “frequency “ meter for proper functionality.Checking “Contactors, ACB for proper functioning /operations.Checking “wiring termination for proper tightness.Checking indicating lamps for proper functioning. Checking if fault/tripping circuits are working satisfactory.Checking if doors are closing properly.Checking if there is no blockage of air from rear ducts.Checking if the front opening is directing the hot air outside room. LOCATION: TEL Exchange,Section Hospital,MAP PH-II PH,C-I Pump House,DOD Main Office,MIDC Pump House
All as per item no-1 here in before but capacity of DG set 125 KVA with AMF Panel in through authorise service agency of OEM ,Make- Kirloskar. Location- DOD Batt Plant Office
All as per item no-1 here in before but capacity of DG set 160 KVA with AMF Panel in through authorise service agency of OEM ,Make- Greaves Cotton. Location: COD
All as per item no-1 here in before but capacity of DG set 200 KVA with AMF Panel through authorise service agency of OEM ,Make- Catter Pillar. Location: Unit KLP
All as per item no-1 here in before but capacity of DG set 40 KVA with AMF Panel through authorise service agency of OEM ,Make- Kirloskar. Location: DAD 2AA/3AA-MAIN GATE,DAD-1-MAIN GATE,DAD-2AA/3AA NEAR GP NO-20,DAD-2AA/3AA NEAR GP NO-30.
All as per item no-1 here in before but capacity of DG set 30 KVA with AMF Panel through authorise service agency of OEM ,Make- Kirloskar,/Greaves Cotton . Location: 787 FAD MELINE,787 SIGNAL EXCHANGE,DOD TEL EXCHANGE.
All as per item no-1 here in before but capacity of DG set 25 KVA with AMF Panel through authorise service agency of OEM ,Make- GREAVES ESCORT, Location: MAP PH-II STP,29FAD ME LINE.
All as per item no-1 here in before but capacity of DG set 12.5 KVA with AMF Panel through authorise service agency of OEM ,Make- GREAVES ESCORTKIRLOSKAR, Location: ATA MAIN GATE.
All as per item no-1 here in before but Disel Engine operated pump of capacity 150 BHP Panel through authorise service agency of OEM ,Make- Kirloskar Location: KINAHI Pump House 1 Nos)
All as per item no-1 here in before but Disel Engine operated pump of capacity 133 BHP Panel through authorise service agency of OEM ,Make- Kirloskar Location: 29 FAD
All as per item no-1 here in before but Disel Engine operated pump of capacity of 47 BHP Panel through authorise service agency of OEM ,Make- Kirloskar. Location: 29 FAD
Calibration of FIP and fuel injector from the authorised dealer, including petty repairs and replaceing the suction & delivery valves, rollers to make the FIP and injectors functional for the capacities of DG set 12.5/25/30KVA ( calibration and repair to be carried out through authorised MICO test bench and test certificate to be submitted by the contractor) all as specified and directed.
Calibration of FIP and fuel injector from the authorised dealer, including petty repairs and replaceing the suction & delivery valves, rollers to make the FIP and injectors functional for the capacities of DG set 40/62.5KVA ( calibration and repair to be carried out through authorised MICO test bench and test certificate to be submitted by the contractor) all as specified and directedthrough authorised MICO test bench and test certificate to be submitted by the contractor) all as specified and directed..
Calibration of FIP and fuel injector from the authorised dealer, including petty repairs and replaceing the suction & delivery valves, rollers to make the FIP and injectors functional for the capacities of DG set 125/160/ 200 KVA ( calibration and repair to be carried out through authorised MICO test bench and test certificate to be submitted by the contractor) all as specified and directedthrough authorised MICO test bench and test certificate to be submitted by the contractor) all as specified and directed..
Calibration of FIP and fuel injector from the authorised dealer, including petty repairs and replaceing the suction & delivery valves, rollers to make the FIP and injectors functional for the capacities of Engine operated Pump of capacity 47 BHP to 150 BHPP ( calibration and repair to be carried out through authorised MICO test bench and test certificate to be submitted by the contractor) all as specified and directedthrough authorised MICO test bench and test certificate to be submitted by the contractor) all as specified and directed..
Supply the following .(The Periodicity of change of filter as per manufacturer/authorised service agency recommendation)
Fuel filter pre/Micro for 125/160/ 200 kva DG set
Fuel filter pre/Micro for 40/62.5/ kva DG set
Fuel filter pre/Micro for 30/25/12.5kva DG set
Fuel filter pre/Micro for 150/133/47BHP Diesel Engine pump
Lub Oil filter for 125/160/ 200 kva DG set
Lub Oil filter for 40/62.5/ kva DG set
Lub Oil filter for 30/25/12.5kva DG set
Lub Oil oil filter for 150/133/47BHP Diesel Engine pump
Air filter for 125/160/ 200 kva DG set
Air filter for 40/62.5/ kva DG set
Air filter for 30/25/12.5kva DG set
Air filter for 150/133/47BHP Diesel Engine pump
Fan V-belt for 125/160/ 200 kva DG set
Fan V- belt for 40/62.5/ kva DG set
Fan V-belt for 30/25/12.5kva DG set
Fan V-belt for 150/133/47BHP Diesel Engine pump
starter push bottom for any capacity DG set,
fuel pump assy for 125/62.5 kva DG set,
fuel pump assy for 40/30/25/12.5 kva DG set,
fuel pump assy for 160 kva DG set,
fuel pump assy for 200 kva DG set,
return oil pipe with suitable size nozzle for DG set of any capacity
Lube oil pressor pipe with suitable size nozzle for DG set of any capacity
Fuel pipe with suitable size nozzle for DG set of any capacity
Nut M-8 for DG set of any capacity
Oil pressure gauge15 to 62.5 KVA DG Set capacity
Oil pressure gauge125 to 200 KVA DG Set capacity
Engine oil Temp gauge15 to 62.5 KVA DG Set capacity
Engine oil Temp gauge125 to 200 KVA DG Set capacity
Coolent for radiators
Topping up engine oil multi grade 15w to 40W in engine all as specified and directed. (Make KEOL Oil/ Castrol /HP)
M&L for repair the engine 200 kva Make:- Catterpillar with the following details (a) Check cylinder head for valve leakage/grinding,polishioning the same. (b) Decarbonization of combustion chamber,piston ring grooves. (c )S&F the piston ring complete =01set. (d) S&F Piston pin =1 set (e)S&FCylinder head bolt =1 set (f)S&F Cylinder liner=1 set (g)S&F Inlet valve seat =1 set (h) S&F Exhust valve seat = 1Set (j) S&F Valve guid =1 set (k)S&F all joints,gaskets & O rings=01set. (l)S&F thermostate =01no m) cleaning the cooling system,stainer, diesel tank,engine sump=01job. (n) S&F water pump =01no. (o)S&F Coolent Hose-1set (p)S&F fuel ratio control-01no (q) Reassemble all parts and testing complite all as directed.
M&L for repair the engine of engine 160/125 kva Make:- Kirloskar with the following details (a) Check cylinder head for valve leakage/grinding,polishioning the same. (b) Decarbonization of combustion chamber,piston ring grooves. (c )S&F the piston ring complete =01set. (d) S&F Piston pin =1 set (e)S&FCylinder head bolt =1 set (f)S&F Cylinder liner=1 set (g)S&F Inlet valve seat =1 set (h) S&F Exhust valve seat = 1Set (j) S&F Valve guid =1 set (k)S&F all joints,gaskets & O rings=01set. (l)S&F thermostate =01no m) cleaning the cooling system,stainer, diesel tank,engine sump=01job. (n) S&F water pump =01no. (o)S&F Coolent Hose-1set (p)S&F fuel ratio control-01no (q) Reassemble all parts and testing complite all as directed.
M&L for repair the engine of engine 62.5 kva Make:- Kirloskar/Greaves with the following details (a) Check cylinder head for valve leakage/grinding,polishioning the same. (b) Decarbonization of combustion chamber,piston ring grooves. (c )S&F the piston ring complete =01set. (d) S&F Piston pin =1 set (e)S&FCylinder head bolt =1 set (f)S&F Cylinder liner=1 set (g)S&F Inlet valve seat =1 set (h) S&F Exhust valve seat = 1Set (j) S&F Valve guid =1 set (k)S&F all joints,gaskets & O rings=01set. (l)S&F thermostate =01no m) cleaning the cooling system,stainer, diesel tank,engine sump=01job. (n) S&F water pump =01no. (o)S&F Coolent Hose-1set (p)S&F fuel ratio control-01no (q) Reassemble all parts and testing complite all as directed.
M&L for repair the engine of engine 40 kva Make:- Kirloskar/Greavs with the following details (a) Check cylinder head for valve leakage/grinding,polishioning the same. (b) Decarbonization of combustion chamber,piston ring grooves. (c )S&F the piston ring complete =01set. (d) S&F Piston pin (e)S&FCylinder head bolt (f)S&F Cylinder liner=1 set (g)S&F Inlet valve seat (h) S&F Exhust valve seat (j) S&F Valve guid (k)S&F all joints,gaskets & O rings=01set. (l)S&F thermostate =01no m) cleaning the cooling system,stainer, diesel tank,engine sump=01job. (n) S&F water pump =01no. (o)S&F Coolent Hose-1set (p)S&F fuel ratio control-01no (q) Reassemble all parts and testing complite all as directed.
M&L for repair the engine of engine 30/25 kva Make:- Kirloskar/Greaves with the following details (a) Check cylinder head for valve leakage/grinding,polishioning the same. (b) Decarbonization of combustion chamber,piston ring grooves. (c )S&F the piston ring complete =01set. (d) S&F Piston pin (e)S&FCylinder head bolt (f)S&F Cylinder liner=1 set (g)S&F Inlet valve seat (h) S&F Exhust valve seat (j) S&F Valve guid (k)S&F all joints,gaskets & O rings=01set. (l)S&F thermostate =01no m) cleaning the cooling system,stainer, diesel tank,engine sump=01job. (n) S&F water pump =01no. (o)S&F Coolent Hose-1set (p)S&F fuel ratio control-01no (q) Reassemble all parts and testing complite all as directed.
M&L for repair the engine of engine 12.5 kva Make:- Kirloskar with the following details (a) Check cylinder head for valve leakage/grinding,polishioning the same. (b) Decarbonization of combustion chamber,piston ring grooves. (c )S&F the piston ring complete =01set. (d) S&F Piston pin (e)S&FCylinder head bolt (f)S&F Cylinder liner=1 set (g)S&F Inlet valve seat (h) S&F Exhust valve seat (j) S&F Valve guid (k)S&F all joints,gaskets & O rings=01set. (l)S&F thermostate =01no m) cleaning the cooling system,stainer, diesel tank,engine sump=01job. (n) S&F water pump =01no. (o)S&F Coolent Hose-1set (p)S&F fuel ratio control-01no (q) Reassemble all parts and testing complite all as directed.
Disconnecting the electric connection of Alternator of capacity 200/160/125 KVA DG set ,taking the accumalator of DG Set and cleaning the core assembly through air blower,dicarbonozing and heat varnishing with insulating material complete and reassembling the same and re installed all as directed.
Disconnecting the electric connection of Alternator of capacity 62.5 KVA DG set ,taking the accumalator of DG Set and cleaning the core assembly through air blower,dicarbonozing and heat varnishing with insulating material complete and reassembling the same and re installed all as directed.
Disconnecting the electric connection of Alternator of capacity 40/30/25 KVA DG set ,taking the accumalator of DG Set and cleaning the core assembly through air blower,dicarbonozing and heat varnishing with insulating material complete and reassembling the same and re installed all as directed.
Disconnecting the electric connection of Alternator of capacity 12.5 KVA DG set ,taking the accumalator of DG Set and cleaning the core assembly through air blower,dicarbonozing and heat varnishing with insulating material complete and reassembling the same and re installed all as directed.
Taking down unserviceable parts and Supply and fixing Stop solonoid switch 12Volts
Taking down unserviceable parts and Supply and fixing Stop solonoid switch 24 Volts
Disconnecting Alternator 125/160/200VA from engine and transportating to work shope for repair and return. dismantling carefully the alternator completely and cutting and removing the burnt windings , rewinding with existing size/gauge of super enameled copper conductor and other approved insulating materials, heating, drying including varnishing, overhauling, checking and segregating serviceable and unserviceable parts, cleaning/dicarbonizing and servicing the serviceable parts by approved method, replacing unsv parts,(new parts required to be measured and paid seperately in respective schedule of item) reassembling the alternator completely and , installing, commissioning, testing and connecting up complete, all as directed. Make : Crompton greaves/Kirloskar
Disconnecting Alternator 62.5KVA from engine and transportating to work shope for repair and return. dismantling carefully the alternator completely and cutting and removing the burnt windings , rewinding with existing size/gauge of super enameled copper conductor and other approved insulating materials, heating, drying including varnishing, overhauling, checking and segregating serviceable and unserviceable parts, cleaning/dicarbonizing and servicing the serviceable parts by approved method, replacing unsv parts,(new parts required to be measured and paid seperately in respective schedule of item) reassembling the alternator completely and , installing, commissioning, testing and connecting up complete, all as directed. Make : Crompton greaves/Kirloskar
Disconnecting Alternator 40/30/25KVA from engine and transportating to work shope for repair and return. dismantling carefully the alternator completely and cutting and removing the burnt windings , rewinding with existing size/gauge of super enameled copper conductor and other approved insulating materials, heating, drying including varnishing, overhauling, checking and segregating serviceable and unserviceable parts, cleaning/dicarbonizing and servicing the serviceable parts by approved method, replacing unsv parts,(new parts required to be measured and paid seperately in respective schedule of item) reassembling the alternator completely and , installing, commissioning, testing and connecting up complete, all as directed. Make : Crompton greaves/Kirloskar
supply the following .(The Periodicity of change of filter as per manufacturer/authorised service agency recommendation)
Eye bolt suitable for 200/160/125/62.5/40/30/25/12.5 Kva alternator
fan key suitable for 200/160/125/62.5/40/30/25/12.5 Kva alternator
Circlip suitable for 200/160/125/62.5/40/30/25/12.5 Kva alternator
DE Bearing HSG suitable for200/160/125 Kva alternator
DE Bearing HSG suitable for62.5/40/30/25/12.5 Kva alternator
Brush holder spindle suitable for 200/160/125 Kva alternator
Brush holder spindle suitable for 62.5/40/30/25/12.5 Kva alternator
NDE bearing cap suitable for 200/160/125 Kva alternator
NDE bearing cap suitable for /62.5/40/30/25/12.5 Kva alternator
Terminal box with LID suitable for 200/160/125/62.5/40/30/25/12.5 Kva alternator
Ventilation grids suitable for 200/160/125/62.5/40/30/25/12.5 Kva alternator
Slipring assembly suitable for 200/160/125/62.5/40/30/25/12.5 Kva alternator
Exicitation (CX) unit sutable for 200/160/125 Kva alternator
Exicitation (CX) unit sutable for 62.5/40/30/25/12.5 Kva alternator
self starter 24 volt dc
self starter 12 volt dc
Indicator lamp suitable for AMF panel
Three pole power contractor ,Type -MNX-110 ,Aux contacts 2NO=2NC ,Catno-CS94137 suitable for AMF panel
AC control contractor -MO0AC-15 4A at415 volt ,Catno-CS94826suitable for AMF panel
DC control contractor -MO0AC-15 4A at415 volt ,Catno-CS94667suitable for AMF panel Make:L&T
Battery terminal made with brass for 24 volt battery
energy storage bank capacity12 volt 180 AH, 24 plate all as directed.
Material with labour for painting the aquistic enclosure, Diesel engine , alternator, AMF panel with two coat of synthatic enamel paint after necessary scrapping the old paint, denting the damage portion complet of size 125/160/200 KVA capacity all as directed.
Material with labour for painting the aquistic enclosure, Diesel engine , alternator, AMF panel with two coat of synthatic enamel paint after necessary scrapping the old paint, denting the damage portion complet of size 62.5/40 KVA capacity all as directed.
Material with labour for painting the aquistic enclosure, Diesel engine , alternator, AMF panel with two coat of synthatic enamel paint after necessary scrapping the old paint, denting the damage portion complet of size 30/25/12.5 KVA capacity all as directed.
Taking down unserviceable copper cable and supply and fixing PVC insulated XLPE Insulated unarmored heavt duty copper cable 4 core 16 sqmm including copper lug complet all as directed.
Taking down unserviceable copper cable and supply and fixing PVC insulated XLPE Insulated unarmored heavt duty copper cable 4 core 25 sqmm including copper lug complet all as directed.
Taking down unserviceable copper cable and supply and fixing PVC insulated XLPE Insulated unarmored heavt duty copper cable 4 core 35 sqmm including copper lug complet all as directed.
Taking down unserviceable on load change over switch open exucution type and Supply and fixing on load change over 320 amps ,415 volt AC,Conforms to IS/IEC:60947-3), complet all as directed.
Taking down unserviceable on load change over switch open exucution type and Supply and fixing on load change over 200 amps ,415 volt AC,Conforms to IS/IEC:60947-3), complet all as directed.
Taking down unserviceable on load change over switch open exucution type and Supply and fixing on load change over 125 amps ,415 volt AC,Conforms to IS/IEC:60947-3), complet all as directed.
Taking down unserviceable change over switch and Supply and fixing on load change over 63 amps ,415 volt AC,Conforms to IS/IEC:60947-3), complet all as directed.
Disconnection the existing Electric connection from Panel/Alternator of DG set any capacity, Taking out the DG set complet and Reinstalled in new locatin and necessary connection all as directed.
Disconnections suction and discharge line connection,Diconnection coupling motor of Disel Engine operated pump of capacity 150/133/47 BHP . Lifting and removing pump form its existing foundation. Dismantling the pump carefully checking, segregating serviceable,repairable and unserviceable parts, cleaning the serviceable parts thoroughly by approved method (Pats like shaft, key,Impellior,bearing upper casing etc) including replacement of unserviceable parts as required (The same will be measured and paid separately in respectable items mention bellow). Reassembling the pump including painting with two coats of synthetic enamel paint after necessary surface preparation , marking of number (SM, MES or srl No) installing to its existing foundation, commissioning, connecting up and testing complete as directed . Pump Make=Kirloskar. Note:(i) Spare parts for repair/replace will measured in respective items as per site required
Repair the Impeller 1st stage with metaling, grinding,polishing,balancing with true shape Suitable for Disel Engine operated pump of capacity 150/133/47 BHP - ,Kirloskar
Repair the Impeller 2nd stage with metaling, grinding,polishing,balancing with true shape Suitable for Disel Engine operated pump of capacity 150/133/47 BHP - ,Kirloskar
Repair the Pump shaft with metaling, grinding,polishing,balancing with true shape Suitable for Disel Engine operated pump of capacity 150/133/47 BHP - ,Kirloskar
Supply Coupling Key Suitable for Disel Engine operated pump of capacity 150/133/47 BHP- ,Kirloskar
Supply Key for Impeller Suitable for Disel Engine operated pump of capacity 150/133/47 BHP - ,Kirloskar
Supply Key for Sleeve Nut Suitable Disel Engine operated pump of capacity 150/133/47 BHP -Kirloskar
Supply Bolt for upper and lower half casing Suitable for Disel Engine operated pump of capacity 150/133/47 BHP -Kirloskar
Supply Taper pin with washers and nuts for lower and upper half casingCoupling Key suitable for Disel Engine operated pump of capacity 150/133/47 BHP .Make Kirloskar.
Supply Draing plug for casing Suitable for Disel Engine operated pump of capacity 150/133/47 BHP
Supply O ring for shast sleev suitable for Disel Engine operated pump of capacity 150/133/47 BHP -Kirloskar
Supply Wear Ring suitable for Pump set Suitable for Disel Engine operated pump of capacity 150/133/47 BHP -Kirloskar
Supply Shoulder Ring in CI Suitable for Disel Engine operated pump of capacity 150/133/47 BHP
Supply Interstage Ring Suitable for Disel Engine operated pump of capacity 150/133/47 BHP Kirloskar
Supply Lantern Ring Suitable for Disel Engine operated pump of capacity 150/133/47 BHP -Kirloskar
Supply DE ball bearing Suitable for Disel Engine operated pump of capacity 150/133/47 BHP -,Kirloskar
Supply DE Bearing Cover Suitable for Disel Engine operated pump of capacity 150/133/47 BHP ,Kirloskar
Supply NDE Bearing Suitable for Disel Engine operated pump of capacity 150/133/47BHP -Kirloskar
Supply Bearing nut,Suitable for Disel Engine operated pump of capacity 150/133/47 BHP -Kirloskar
Supply Shaft sleeve, DE/NDE,Suitable for Disel Engine operated pump of capacity 150/133/47 BHP -Kirloskar
Supply stuffing box bush,Suitable for Disel Engine operated pump of capacity 150/133/47 BHP -Kirloskar
Supply Air vent,Suitable for Disel Engine operated pump of capacity 150/133/47 BHP -Kirloskar
Supply Hex screw for bearing cover,Suitable for Disel Engine operated pump of capacity 150/133/47 BHP -Kirloskar
Supply Cylindrical pin,Suitable for Disel Engine operated pump of capacity 150/133/47 BHP -Kirloskar
Supply Round Lock nut ,Suitable for Disel Engine operated pump of capacity 150/133/47 BHP -Kirloskar
Supply Gland Packing,Suitable for Disel Engine operated pump of capacity 150/133/47 BHP -Kirloskar
Supply Vent Valve,Suitable for Disel Engine operated pump of capacity 150/133/47 BHP -Kirloskar
Supply Gland stuffing box suitable for nut and bolts Suitable for Disel Engine operated pump of capacity 150/133/47 BHP -Kirloskar
Supply Cooling PVC flexible of Suitable for Disel Engine operated pump of capacity 150/133/47 BHP -Kirloskar
Shri Sai Electricals (BID ID -3108189)
Shriyansh sales and services (BID ID -3122538)
Crown Chemicals (BID ID -3108607)
PREETI ENTERPRISES (BID ID -3108159)
M/S kirpan Enterprises (BID ID -3108763)
Star Electrical (BID ID -3108261)
shri yash enterprises (BID ID -3106744)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .