| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 LAccepted-Finance | L1 | Accepted-Finance Being lowest | |
| 2 | L2₹1.5 L+₹28,556 (24.0%)Rejected-Finance | L2 | Rejected-Finance Being high rate | |
| 3 | L2₹1.5 L+₹28,556 (24.0%)Rejected-Finance | L2 | Rejected-Finance Being high rate |
Tender Value
Refer Docs
Closing Date
10 Jul 2021, 6:00 pmClosed
SHRI VINEET MODI, SE,IDSE
CWE (AF) (NORTH) BANGALORE
Consultancy services for preparation of structural analysis, design and detailed structural drawings for covered roof of size 17x14 Mtr for weather shelter for the work Improvement of security infrastructure at 26 ED and MP Camp
2021_MES_455282_1
30048/Q/1/E3
Limited
Consultancy Services
Item Rate
60 days
CWE (AF) (NORTH) BANGALORE
As per NIQ
1 document required · 1 mandatory
₹0
Exempted
12 Jul 2021
28 Jun 2021
12 Jul 2021
28 Jun 2021
10 Jul 2021
28 Jun 2021
28 Jun 2021 - 30 Jun 2021
(a) Preparation of structural analysis, design and detailed structural drawings for covered roof of size 17 x 14 Mtr for weather shelter with steel tubular trusses and galvalume sheet roof over RCC column and based on architectural drawing for the work Improvement of security infrastructure at 26 ED and MP Camp (b) The design has been to be preferably done using standard software e.g. STAADPRO or STRAP etc (c) The RCC structure shall be designed as per IS 456-2000 and IS 1893-2002 and steel structure shall be designed as per relevant IS Code Note : Consultant shall submit the following (A) Structural Drawings (i) All structural drawings including the details of expansion joints in original tracing (ii) Design folder containing design sheets including load calculations, meterial strength design calculations and drawings duly vetted by any of the IITs/IISc Bangalore/any Govt Engineering College. These documents shall also be submitted in a soft copy (on CD) (iii) A certificate from the vetting agency, as above to confirm that the design is meeting the relevant codal requirements shall also be submitted (iv) Soil investigation report will be collected by the firm from the department prior to designing (iv) All reinforcement including the parameters provided in RCC General notes bearing drawing No AFB/TD/230/04 sheet 1/1 and AFB/TD/231/04 sheet 1/2 and 2/2 ductile details bearing drawing No AFB/TD/222/04 sheet 1/1 shall be taken into consideration in addition to the details given in structural drawings Grade of concrete - M25 Grade of sheet - Fe 500 Exposure condition - Moderate
Ashvika Consultants
M/S EDIFICE INC
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
finance_507553.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .