Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC | ₹42.7 L | L1 | Accepted-AOC AOC accepted. |
| 2 | L2₹46.4 L+₹3.7 L (8.65%)Rejected-AOC M S 4BC PITAMPURA DELHI 110034 | DELHI | NORTH WEST DELHI | DELHI | 110034 | ₹46.4 L+₹3.7 L (8.65%) | L2 | Rejected-AOC AOC rejected. |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
16 May 2022, 6:00 pmClosed
GE Dehradun
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
Repair and replacement of CI DI MS GI and sluice valve NRV Gate Valve of various sizes near Beacher road Pump House and repair and replacement of Dozing system of Zone A under AGE EM-I of GE Dehradun.
2022_MES_518913_1
8453/A/E8
Open Tender
Civil Works
Item Rate
240 days
GE Dehradun
Class D Cat a (ii)
8 documents required · 8 mandatory
₹500
GE Dehradun
₹90,000
30 Jul 2022
20 Apr 2022
18 May 2022
20 Apr 2022
16 May 2022
4 May 2022
Amount
M&L for excavation in trenches in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep including cutting in slopes etc for laying of pipe line/Lt cable including getting out, complete all as specified and directed.
M&L for returning, filling in soils, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm ithick in each layer complete all as specified and directed .
M&L for removal of excavated material (Soil) to a distance up to 50 meter from starting point and depositing where directed at level not exceeding 1.5 meter above complete all as specified and as directed .
M&L for Cleaning outer surface of existing water pipe line including sluice valve or other type of valve fitted with the existing water pipe line, preparing the surface for painting and painting with two coat of synthetic enamel paint with existing color code / with approved color code, complete all as specified for the following sizes at pump house / overhead tank. Note :- All existing water pipe line is laying vertical or horizontal to the ground surface. All arrangements for painting of vertical water pipe line shall be responsibility of contractor and cost of any arrangements or cost of rent of required T&P (if required) shall be included in the quoted rate of the item.
80 mm Dia to 100 mm dia
125 mm Dia to 200 mm dia
M&L for Painting to pit cover of valve chamber/sluice valve chamber with frame with two coats of black synthetic enamel paint over a coat of red oxide primer including preparation of surface by cleaning/brushing to remove flakes as directed by Engineer-in-charge for the following sizes of chambers:-
600mmx600mmx600mm to 900mmx900mmx900mm
120mmx120mmx120mm to 150mm x150mmx150mm
Dismantling the damaged valve pit chamber of size 60x60x60cm to 80x80x80cm and construction of new brick masonry valve pit of internal size 60x60x60cm to 80x80x80 cm with 230mm thick brick wall built in cement mortar 1:4 and base surface area of valve chamber shall also built in PCC 1:3:6 type c-1 with plastering 15mm wall sides in cement mortar 1:4 and the pit covered with MS plain sheet 3 mm thick duly fixed to MS angle iron of size 40x40x3mm and duly embedded in plain cement concrete coping 5 cm thick plain cement concrete 1:2:4 type B1with opening and locking arrangements including painting with two coat of synthetic enamel paint over one coat of primer complete all as directed.
All as per item No- 6.00 here in before but size of pit 90x90x90 cm to 110x110x110 cm complete all as specified and as directed.
All as per item No- 6.00 here in before but size of pit 120x120x120 cm to 150x150x150 cm complete all as specified and as directed.
Dewatering the existing underground sump/semi underground sump, overhead reservoir and cleaning of internal wall and bottom surface and ceiling of tank/sump to remove silt / scales, mud and other foreign materials using water and scrubbing with coir / jute / wire brush and washing the all surfaces with fresh water cleaning the surfaces with mixture of bleaching powder and water and finally washing with fresh water and treating with one coat of white wash to internal walls, bottom surfaces, and ceiling of tank / sump complete including writing CLEANED ON DATE with white paint on black back ground on external surface of the sump/tank at a convenient height (letter size-5cm) complete all as specified and as directed for following sizes:-
Under ground sump 40,000 gallons capacity
Under ground sump 50,000 gallons capacity
Under ground sump 100,000 gallons capacity
Over head tank 50,000 gallons capacity
Over head tank 100,000 gallons capacity
Over head tank/sump 25,000 gallons capacity on roof of MH Bldg
Disconnecting the existing water pipe line of 100 mm to 150 mm in size from sluice valve/NRV/or any other machineries and taking out the same from valve chamber and material and labour for reconnecting, relaying, rejointing of existing water pipe line in same manner (rejointing with sluice valve/NRV/or any other machineries) from 60cm above the ground level (distance between bottom of sluice valve /NRV and ground level not less the 60cm). Shape of relaying of water pipe line with existing sluice valve / NRV shall be "Inverse U type" (Lenght of new water pipe line shall not be less than 75 cm in vertical side from ground level in each side and not less than 100 cm in horizontal side including sluice valve) Rate of all items i.e. any type of joints (flanged / socketed/tyton rubber ring/ D joint etc), welding or lead joint including all type of required fittings such as socket/union/tail peice/ bend by cutting /threading/welding as required at site shall be included in quoted rate ot this item. Note:- (i) Any required lenght of pipe of existing size deemed to be included in the quoted rate. (ii) Any earth work required for repair deemed to be included in the quoted rate. (iii) Repair in all respect (if required) of existing Sluice valve of existing size as per site deemed to be included in the quoted rate
Dismantling and taking out the existing corroded / scaled GI pipe / PPR/ PALP pipe with fittings connections from trenches, walls, ceiling or floor and removal from site or disposed off for the following sizes complete all as specifed and directed. Note: Excavation and earth work shall be measured and paid seperately under respective item of schedule "A"
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Refixing of Old GI tubing in new or Old position (walls, ceiling, floors and trench etc) for the following size complete all as specified and directed. Note: Excavation and earth work shall be measuered and paid seperately under respective item of schedule 'A"
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply, Laying, fixing & testing galvanished iron water tubing 'medium grade; with and inclduing all GI fittings such as flanges, unions reducers sockets, socket reducing bends , elbows, tee, checkneuts, caps, plugs etc laid in trenches for the following sizes complete all as specifed and directed. Note: Excavation and earth work shall be measuered and paid seperately under respective item of schedule 'A" .
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply, Laying, fixing & testing galvanished iron water tubing 'medium grade; 20 mm bore ISI marked with and inclduing all GI fittings such as flanges, unions reducers sockets, socket reducing bends , elbows, tee, checkneuts, caps, plugs etc fixed to wall, lain in floors for the following sizes complete all as specifed and directed.
Material and labour for any type of structural steel sections , nut- bolt, washers, sheets, back plate, xpm mesh, wire mesh, bending, cutting in shape, welding, drilling holes, flanges including painting with two coats of synthetic enamel paint over a coat of red oxide primer as in pit cover,grating etc, complete all as specified and directed.
Dismantling/taking out defective Gun metal gate valve and S&F new Gun metal gate valve with iron wheel head by screwing/cutting of existing pipe lines for the following size complete all as specifed and directed.
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply and fixing CI sluice valve both end flanged dully drilled for both ends with stainless steel spindle (Riising spindle) and nuts stuffing box etc type PN - 1.6, ISI marked of following sizes including taking down the old unserviceable sluice valve and deposit to MES store yard:-
200 mm bore
150 mm bore
125 mm bore
100 mm bore
80 mm bore.
Supply and fixing CI sluice valve both end flanged dully drilled for both ends with stainless steel spindle (Non riising spindle)and nuts stuffing box etc type PN - 1.6, ISI marked of following sizes including taking down the old unserviceable suuice valve and deposit to MES store yard:-
200 mm bore
150 mm bore
100 mm bore
80 mm bore.
Dismantling /taking out defective CI non return valve and Supply and fixing new CI Non return valve flanged ends as per IS-5312 complete with Nuts/Bolts and washers and rubber packing etc for the following sizes:-
300 mm bore
150 mm bore
125 mm bore
Dismantling and taking out old unserviceable foot valve and supply and fixing new foot valve, One end flanged and strainer to the other side for the following sizes:-
80 mm bore
100 mm bore
125 mm bore
150 mm bore
200 mm bore
S&F in replacement water pressure gauge glycerin filled stainless steel body of size 100 mm 0-10 kg/cm2 complete all as specified & Directed. Make : H Guru or equivalent
Supply Installation Testing and Commissioning of Digital water level indicator device, operating on single phase supply, direct display in 100mm size digit system in meter/centimeter of water level of sumps/over head tank. The entire unit must operate through a compact circuit, which must ensure reliable operation at 230 volts +/- 5% with reliable in dight display. The circuit must be housed in MS CRC sheet box with nylon molded conncetion strips. The level system must resistance transducer, which unaffected by corrosion and other contacts available in water. The product must be controlled by micro switch. The whole unit must electronically controlled and the upper level and lower indicator must be highly sensitive MICRO SWITCH. The complete unit must be in two parts . Each complete part must be fitted in MSCRC sheet box separately one must be installed at SUMP / OVER HEAD TANK with proper power coating paints. The unit shall have High and Low alarm to be set according to requirement based on levels indicated. It should be possible to calibrate the Indicator to display in percentage or liters, centimeters as required and taking out old unserviceable. Make SECO Cat No DDS-04/PHOTRON. Note : (i) Any material like service wire required at site deemed to be included in the above quoted rate. (ii) If overhead tank does not have any provision for climbing on overhead tank than contractor is fully responsible to fix the water level indicator on overhead tank in any situation with own arangement in replacement.
Supply and laying connecting testing in repair PVC insulated sheathed aluminium conductor standard cable of size 4 sqrmm twin core flat or circular 1100 volt grade service connection suspended by insulating hanger not more than 1 mtr apart including 4 mm dia GI suspension wire in replacement, complete all as specified and as directed.
Material and labour for restoration of water supply by identifying and rectifying the water supply leakage repair work, at any location, in any type of leakage i.e. 15mm/ 20mm/25mm dia pipes of GI/ MS with any type of joints i.e. flanged, socketed,welding joint, including required fittings such as socket/ union/ long screw/ nipple, by cutting/ threading as required at site and as directed. Earth work (if required) will be measured in the quoted rate of this item. Note : (i) Any material required for leak repair deemed to be included in the above quoted rate. (ii) Any length of pipe required shall be paid sepertately under relevant item.
Material and labour for resoration of water supply by identifying and rectifying the water supply leakage repair work, at any location, in any type of leakage i.e. 300 mm dia pipe line of CI/ GI/DI/MS with any type of joints i.e. flanged, socketed, tyton rubber ring, D Joint, welding or lead joint including required fittings such as socket/ union/ long screw/ nipple, and clamp with nut bolt required size by cutting/ threading as required at site , chocking of lead with spun yarn or providing new gasket / rubber ring/ nut bolts/ required welding work as per site requirement complete all as specified and as directed. Earth work (if required) will be measured in the quoted rate of this item. If water is continue flowing in that water pipe line at the location of leakage, the contractor is fully responsible to arrest the water leakage in that situation also in all respect. Note : (i) Any material required for leak repair deemed to be included in the above quoted rate. (ii) Any length of pipe required shall be paid sepertately under relevant item.
All as per item No 25 here in above but 200 mm / 250 mm dia water pipe line complete all as specified.
All as per item No 25 here in above but 100 mm / 150 mm dia water pipe line complete all as specified.
All as per item No 25 here in above but 40mm / 50mm/ 80mm dia pipes complete all as specified.
Material and labour for MS ERW steel pipe 7.0 mm thick of 150mm dia for replacement of header of pup set delivery complete all as specified.
Material and labour MS flange min 8 mm thick of 150mm dia duly drilled holes including welding in plain end of MS pipe with one rubber gasket complete all as specified..
S&F cast iron 'D' joint set complete of two flanged collar one no sleeve two nos rubber 'O' ring and nut bolts washers of suitable size for 200 mm bore CI/DI pipe complete including necessary cutting, grinding work to fix in pipe as directed. (Note:- Earth work required to clear the existing pipe line shall be measured and paid separately)
All as per item No 31 here in above but 150 mm bore complete all as specified.
All as per item No 31 here in above but 100 mm bore complete all as specified.
All as per item No 31 here in above but 80 mm bore complete all as specified.
M&L for repair of Water Level Monitor Device devloped on latest Technology of Make : SECO CAT No 211211 and make functional in all respect and recharge 2 Nos SIM card for 11 months (01 No SIM card in transmitt unit and 01 No SIM card in reciever unit) complete all as specified..
M & L for CI fitting / DI fittings for spigot & socket end pipes such as Bends (any type, radius and angle), Tapers any type (Straight, bend, increasing, decreasing or double socket etc), Tee pieces single branch, `Y` junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs and mechanical joints any type etc upto 150 mm bore including removing/ dismantling of old CI fittings complete all as specified and directed.
37. Cutting of cast iron pipe mains 200 mm bore for insertion of tees, collars, sluice valves, etc including dewatering work required for working water pipe lines complete all as specified and directed.
All as per item No 37 here in above but 150 mm bore complete all as specified.
All as per item No 37 here in above but 100 mm bore complete all as specified.
All as per item No 37 here in above but 80 mm bore complete all as specified.
Taking up or down cast iron pipe of tyton joint/lead joint type from trenches including dismentling tyton joints/lead joint type & removing for disposal for the pipes of 200 mm bore complete all as specified and directed.
All as per item No 41 here in above but 150 mm bore complete all as specified.
All as per item No 41 here in above but 100 mm bore complete all as specified.
All as per item No 41 here in above but 80 mm bore complete all as specified.
Supplying and laying in trenches DI pipe 200 mm bore, with spigot and socket end, class K7 ISI marked as per IS 8329 complete all as specified and directed. Make : Electrosteel/TATA/JINDAL
All as per item No 45 here in above but 150 mm bore complete all as specified.
All as per item No 45 here in above but 100 mm bore complete all as specified.
All as per item No 45 here in above but 80 mm bore complete all as specified.
M&L for tyton rubber gasket joints for 200 mm bore complete all as specified and directed
M&L for tyton rubber gasket joints for 150 mm bore complete all as specified and directed
M&L for tyton rubber gasket joints for 100 mm bore complete all as specified and directed
M&L for tyton rubber gasket joints for 80 mm bore complete all as specified and directed
M&L for painting of different sizes of Valve pit covers, rolling shutters and its related items at various installations as per colour code or approved colour by Engr-in-Charge, with one coat of primer and two coat of synthetic enamelled paint complete all as specified and directed
M&L for taking down old unserviceable Granular chlorination dosing pump and Supply, installation, testing & commissioning of Gnanular chlorination dosing pump(MODEL C 21.117 PP-P),Max.back pressure 10 BAR,LPH(5.76),Delivery Rate(Stokes/hour,Medium back pressure of 6 BAR(LPH 6.4) with Connected accessories and MODEL(ADS-1)- 100 liters FRP tank with lid & Level gauge along with Agitator and shaft & blade in plastic mounted on tank. It should be functioning smoothly on pumping line/supply line upto 75 HP submercible pump. The agitator motor must possess following specifications: (i) Applicable both online and Offline and for which necessary arrangement at site will provide by the contractor without any extra cost. (ii) Voltage input 230V, Single phage, 50HZ, 900 rpm of suitable capacity.(iii) Applicable as Submercible pumps/centrifugal pumps. .
M&L for taking down Calcium hypochlorite Dosing system complete and Supply & fix new Calcium hypochlorite Dosing system(MODEL ADS-1)-100 Ltr.FRP tank with lid & level gauge along with agitator and shaft & blade in plastic mounted on tank.Agitator motor with specification-voltage input-230V,Single phase,50Hz,900 RPM.
Disconnecting and taking down unserviceable dozing system of any capacity from existing connection and shifting to workshop or at site for repair and after repair connect all electrical connections / pipe connections should be connect properly, reassembling resifting & reinstallation at site inclduing testing complete all as specifed & directed. Note:- (i) Spare parts which are required to be replaced during repair shall be measured and paid separately as supply only ,however fixing element shall be deemed to be included in the quoted rates of this item. (ii)Contractor shall ensure water pipe lines sealed by blocking with dead flange for the repair period if required.
Supply only following spares parts to be replaced as repair to dozing system under item No 56 here in above:-
Complete gear motor 230v, having 10 Kg pressure, 50Hz and rotor assembly with bearings brackets & tolerance ring suitable for dozing system at site.
Injection check valve 3/8" (5 in one packing)
Weighte suction line strainer tubing
Check valve (pack of five)
Connecting nut
Ferrule (Pack of five)
Material and labour for dry sand for cushioning to under ground cables in trenches provided with a layer of sand 8cm deep before laying the cable and 15cm deep after laying and stretching the cable complete all as specified and directed .(Note : Punned thickness shall may be measured for payment).
Supply and Laying brick covering with width equal to length of brick as mechanical protection to cable using sub class `B' bricks laid flat size 230x115x75 mm complete all as specified and directed by Engineer-in-Charge.
M & L in replacement cable XLPE insulated screened PVC bedded , galvanized steel strip or wire armoured electric power multi stranded cables 150 Sqmm 3.5 core (heavy duty) 1100 volts laid in trenches passing through pipes /ducts including fixing with necessary lugs at both ends, testing complete all as specified and directed.
Cutting the existing hard standing/ metal road of facilitate for laying of water pipe line and making good the disturbed portion to bring it to original condition with plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate)complete all as specified and as directed.
Supply only Calcium Hypo Chlorite having 65%-70% Chlorine Content (Calcium based granular disinfectant) for general water treatment & swimming pool water treatment, in factory sealed container/drum (45 kg packing), complete all as specified and directed. Calcium Hypochlorite detailed specifications :- (a) Chemical analysis & physical observations - (i) Description : Whitish granules (ii) Granular size (Mesh passing through - 100 BSS): 1.1(+ 0.1)% (iii) Water/moisture : < 5.00% (iv) Mercury & other Heavy Metal contaminants : BDL. (b) Strength in terms of quantity of chlorination chemical required to obtain free chlorine of 1 ppm per lakh liters of water: Requirement must be 140-200 gm per one lakh liter of water to achieve 1 ppm Average at injection point (site & raw water quality variations may apply additionally). Make: Royal Seema/Grasim/Declibac.
Taking down centrifugal pumping set make Kirloskar installed at pump house and supply and fixing Centrifugal pumping set split casing with bronze impeller and stainless steel shaft sleeve of discharge 25000 ltr/hr at 40 mtr head complete with squirrel case induction motor of 15 HP capacity, type TEFC, 3 phase 415 volt mounting on and including comman base plate febricated by heavy duty MS channel and required PCC work as recommended by manufacturer, including pressure gauge 0 to 7 Kg/cm sq glycrine filled wiht brass air cook heavy duty, MS coupling complete with including suitable Star delta type starter with necessary electric connections to motor. This item rate shall be deemed to be inclusive any modification to existing suction and discharge line by providing MS pipe welding work and also inclusive of required spares or any other work required at site for fixing the same. Note:- (i) The contractor is responsible to lift the old Pumping set complete from Pump House and deposit to MES store yard without any extra cost. (ii) Cost of any extra required length of MS pipe (suction or deliver both) shall be included in the quoted rate of this item.
M&L for repair of sluice valve of 150mm size , shifting to workshop for repair and opening dismantling and greasing complete parts, all parts cleaned by Kerosene oil neatly with and including replacement of defective spare parts by news parts including necessary welding machine/ grinding work if required at the time of refitting of spare into sluice valve and refixing on existing water pipe line and testing on full discharge complete all as specified and directed.Note:- (i) Spare parts which are required to be replaced during repair shall be measured and paid separately in after as supply only ,however fixing element shall be deemed to be included in the quoted rates of this item.
Supply only following spares parts to be replaced as repair to sluice valve under item No 64 here in above:-
Spare coupling complete (without chain & cap) as per existing in all respect
Lug bush assembly
Bonnet assembly complete
Handwheel
Rubber seal for landing valve coupling
Spindle for landing
Spindle including seat, washer and nut
Lug bush assemly for hose coupling
Rubber seal
Attending complaints for pumping set/submersible pump set / LT Panel/starter panel/ DG Set / AMF Panel including replacement of defective minor (i.e Aluminium tube terminal of suitable size, glnd packing, M Seal) spare parts and fill the gland packing (if required) checking of all nut bolts and tightening of all nut bolts if found loose, all electrical and mechanical connections, all parameters i.e. pressure, current & voltage ratings, leakage of water, sound of bearing, checking of alignment of motor pump set complete, all as specified and directed. Greasing shall be done with grease gun. Rate of grease, nut bolt, washer shall be included in quoted rate of this item. Note :- (i) Complaints for pumping sets, (Centrifugal and submersible both) LT Panel, Starter Panel/DG Set/AMF Panel at one installation shall be recorded /measured as one complaint / job. (ii) Minimum 01 technician and 01 helper to be provided by contractor to attend the complaints. (iii) After completion of complaint/Job, complaint slip shall be deposit to concerned JE in -charge.
Friends fire Engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .