| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹47.0 L+₹6.9 L (17.2%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹48.8 L+₹8.7 L (21.7%)Rejected-Finance 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹48.9 L+₹8.9 L (22.1%)Rejected-Finance CHANDMARI WARD NO 19 PO PS TEZPUR DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹50.2 L+₹10.1 L (25.2%)Rejected-Finance B S ROAD KOLIBARI TEZPUR 784 001 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | L5 | Rejected-Finance OTHER THAN L1 |
| Sl No | Description | Qty | Unit | DRISTEE ASSOCIATES L6 | Anil Kumar Sarmah L5 | Raj Enterprise L3 | M/S RUSTAM ALI L1 | SHANTI ELECTRIC WORKS L2 | MAHANTA ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Servicing for DG set of capacity 62.5 installed including Jobs to ensure its satisfactory performance and consumable items repair/replacement and the following items free for fixing only
Note :-
Replacement of suitable grade engine oil
S&F for Oil filter, fuel filter and Air filter
S&F for water separator
Radiator cleaning with chemical
S&F for change of fuel pipe
S&F for change of fan belt size
S&F for change of hose pipe with clamp | 6 | EACH JOB | 22,500 ₹1,35,000 | 21,400 ₹1,28,400 | 27,500 ₹1,65,000 | 21,500 ₹1,29,000 | 18,000 ₹1,08,000 Lowest | 20,000 ₹1,20,000 |
| 2.00 | Servicing for DG set of capacity 50 KVA installed including Jobs to ensure its satisfactory performance all as directed by the Engineer-in-Charge.
Note :-
Replacement of suitable grade engine oil
S&F for Oil filter, fuel filter and Air filter
S&F for water separator
Radiator cleaning with chemical
S&F for change of fuel pipe
S&F for change of fan belt size
S&F for change of hose pipe with clamp | 4 | Each job | 18,900 ₹75,600 | 17,500 ₹70,000 | 23,000 ₹92,000 | 18,000 ₹72,000 | 14,000 ₹56,000 Lowest | 16,000 ₹64,000 |
| 3.00 | Servicing for DG set of capacity 40 KVA installed including Jobs to ensure its satisfactory performance all as directed by the Engineer-in-Charge.
Note :-
Replacement of suitable grade engine oil
S&F for Oil filter, fuel filter and Air filter
S&F for water separator
Radiator cleaning with chemical
S&F for change of fuel pipe
S&F for change of fan belt size
S&F for change of hose pipe with clamp | 8 | EACH JOB | 16,500 ₹1,32,000 | 14,600 ₹1,16,800 | 19,500 ₹1,56,000 | 16,000 ₹1,28,000 | 12,000 ₹96,000 Lowest | 14,000 ₹1,12,000 |
| 4.00 | Servicing for DG sets of capacity 30 KVA installed including Jobs to ensure its satisfactory performance all as directed by the Engineer-in-Charge.
Note :-
Replacement of suitable grade engine oil
S&F for Oil filter, fuel filter and Air filter
S&F for water separator
Radiator cleaning with chamical
S&F for change of fule pipe
S&F for change of fan belt
S&F for change of hose pipe with clamp | 2 | EACH JOB | 12,400 ₹24,800 | 10,700 ₹21,400 | 14,500 ₹29,000 | 12,000 ₹24,000 | 9,000 ₹18,000 Lowest | 10,000 ₹20,000 |
| 5.00 | Servicing for DG sets of capacity 12.5 KVA installed including Jobs to ensure its satisfactory performance all as directed by the Engineer-in-Charge.
Note :-
Replacement of suitable grade engine oil
S&F for Oil filter, fuel filter and Air filter
S&F for water separator
Radiator cleaning with chamical
S&F for change of fule pipe
S&F for change of fan belt
S&F for change of hose pipe with clamp | 2 | EACH JOB | 11,600 ₹23,200 | 10,750 ₹21,500 | 15,500 ₹31,000 | 11,500 ₹23,000 | 8,000 ₹16,000 Lowest | 10,000 ₹20,000 |
| 6.00 | Servicing for DG set of capacity 7.5 KVA installed including Jobs to ensure its satisfactory performance all as directed by the Engineer-in-Charge.
Note :-
Replacement of suitable grade engine oil
S&F for Oil filter, fuel filter and Air filter
S&F for water separator
Radiator cleaning with chemical
S&F for change of fuel pipe
S&F for change of fan belt size
S&F for change of hose pipe with clamp | 2 | EACH JOB | 10,500 ₹21,000 | 9,700 ₹19,400 | 13,500 ₹27,000 | 11,500 ₹23,000 | 7,500 ₹15,000 Lowest | 9,500 ₹19,000 |
| 7.00 | Supply only engine oil Grade 20 W 40 complete all as specified and as directed by the Engineer-in-Charge. | 275 | EACH | 440 ₹1,21,000 | 440 ₹1,21,000 | 610 ₹1,67,750 | 445 ₹1,22,375 | 225 ₹61,875 Lowest | 650 ₹1,78,750 |
| 8.00 | Supply & fixing Battery terminal leads of 3 mtr long to starter of Diesel engine provided with brass connector on one end and cable lug on other end complete all as specified and as directed by the Engineer-in-Charge. Make : ISI mark. | 10 | EACH SET | 2,200 ₹22,000 | 2,140 ₹21,400 | 1,550 ₹15,500 | 1,200 ₹12,000 Lowest | 2,000 ₹20,000 | 2,200 ₹22,000 |
| 9.00 | Scraping, removal of rust and complete removal of existing painting, cleaning and applying spray painting with two coats of synthetic enamel paint after attending welding work to corroded portion over a coat of red oxide primer to the 62.5 KVA capacity of DG Sets with apple green tint for engine, smoke gray tint for alternator, black for foundation/bases frame and red for all guards including writing of SM/MES Number on Engine and Alternator all as specified and as directed by the Engineer-in-Charge. | 3 | EACH JOB | 4,850 ₹14,550 | 4,875 ₹14,625 | 3,900 ₹11,700 | 2,500 ₹7,500 Lowest | 5,000 ₹15,000 | 5,000 ₹15,000 |
| 10.00 | Scraping, removal of rust and complete removal of existing painting, cleaning and applying spray painting with two coats of synthetic enamel paint after attending welding work to corroded portion over a coat of red oxide primer to the 50 KVA capacity of DG Sets with apple green tint for engine, smoke gray tint for alternator, black for foundation/bases frame and red for all guards including writing of SM/MES Number on Engine and Alternator all as specified and as directed by the Engineer-in-Charge. | 2 | EACH JOB | 4,850 ₹9,700 | 4,870 ₹9,740 | 3,900 ₹7,800 | 2,500 ₹5,000 Lowest | 5,000 ₹10,000 | 5,000 ₹10,000 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
24 Jul 2025, 6:00 pmClosed
Garrison Engineer (North) Tezpur
Durg Abhiyanta (Sena), Garrison Engineer (N) Tezpur, Military Engineer Service, PIN 901217 C/o 99 APO
REPAIR/MAINTENANCE OF DG SET WITH AMF PANEL, VOLTAGE STABILISER, LIGHTENING CONDUCTOR, GARDEN LIGHTS AND CONNECTED ACCESSORIES AND ALLIED WORKS AT AGE CHARDUAR AREA UNDER GE (N) TEZPUR
2025_MES_715601_1
GE(N)/TEZ/2025-2026/8132
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CHARDUAR AREA UNDER GE (N) TEZPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (N) TEZPUR
₹92,000
Yes
13 Sept 2025
19 Jun 2025
26 Jul 2025
19 Jun 2025
24 Jul 2025
2 Jul 2025
19 Jun 2025 - 2 Jul 2025
Amount
Servicing for DG set of capacity 62.5 installed including Jobs to ensure its satisfactory performance and consumable items repair/replacement and the following items free for fixing only Note :- Replacement of suitable grade engine oil S&F for Oil filter, fuel filter and Air filter S&F for water separator Radiator cleaning with chemical S&F for change of fuel pipe S&F for change of fan belt size S&F for change of hose pipe with clamp
Servicing for DG set of capacity 50 KVA installed including Jobs to ensure its satisfactory performance all as directed by the Engineer-in-Charge. Note :- Replacement of suitable grade engine oil S&F for Oil filter, fuel filter and Air filter S&F for water separator Radiator cleaning with chemical S&F for change of fuel pipe S&F for change of fan belt size S&F for change of hose pipe with clamp
Servicing for DG set of capacity 40 KVA installed including Jobs to ensure its satisfactory performance all as directed by the Engineer-in-Charge. Note :- Replacement of suitable grade engine oil S&F for Oil filter, fuel filter and Air filter S&F for water separator Radiator cleaning with chemical S&F for change of fuel pipe S&F for change of fan belt size S&F for change of hose pipe with clamp
Servicing for DG sets of capacity 30 KVA installed including Jobs to ensure its satisfactory performance all as directed by the Engineer-in-Charge. Note :- Replacement of suitable grade engine oil S&F for Oil filter, fuel filter and Air filter S&F for water separator Radiator cleaning with chamical S&F for change of fule pipe S&F for change of fan belt S&F for change of hose pipe with clamp
Servicing for DG sets of capacity 12.5 KVA installed including Jobs to ensure its satisfactory performance all as directed by the Engineer-in-Charge. Note :- Replacement of suitable grade engine oil S&F for Oil filter, fuel filter and Air filter S&F for water separator Radiator cleaning with chamical S&F for change of fule pipe S&F for change of fan belt S&F for change of hose pipe with clamp
Servicing for DG set of capacity 7.5 KVA installed including Jobs to ensure its satisfactory performance all as directed by the Engineer-in-Charge. Note :- Replacement of suitable grade engine oil S&F for Oil filter, fuel filter and Air filter S&F for water separator Radiator cleaning with chemical S&F for change of fuel pipe S&F for change of fan belt size S&F for change of hose pipe with clamp
Supply only engine oil Grade 20 W 40 complete all as specified and as directed by the Engineer-in-Charge.
Supply & fixing Battery terminal leads of 3 mtr long to starter of Diesel engine provided with brass connector on one end and cable lug on other end complete all as specified and as directed by the Engineer-in-Charge. Make : ISI mark.
Scraping, removal of rust and complete removal of existing painting, cleaning and applying spray painting with two coats of synthetic enamel paint after attending welding work to corroded portion over a coat of red oxide primer to the 62.5 KVA capacity of DG Sets with apple green tint for engine, smoke gray tint for alternator, black for foundation/bases frame and red for all guards including writing of SM/MES Number on Engine and Alternator all as specified and as directed by the Engineer-in-Charge.
Scraping, removal of rust and complete removal of existing painting, cleaning and applying spray painting with two coats of synthetic enamel paint after attending welding work to corroded portion over a coat of red oxide primer to the 50 KVA capacity of DG Sets with apple green tint for engine, smoke gray tint for alternator, black for foundation/bases frame and red for all guards including writing of SM/MES Number on Engine and Alternator all as specified and as directed by the Engineer-in-Charge.
Scraping, removal of rust and complete removal of existing painting, cleaning and applying spray painting with two coats of synthetic enamel paint after attending welding work to corroded portion over a coat of red oxide primer to the 40 KVA capacity of DG Sets with apple green tint for engine, smoke gray tint for alternator, black for foundation/bases frame and red for all guards including writing of SM/MES Number on Engine and Alternator all as specified and as directed by the Engineer-in-Charge.
Scraping, removal of rust and complete removal of existing painting, cleaning and applying spray painting with two coats of synthetic enamel paint after attending welding work to corroded portion over a coat of red oxide primer to the 30 KVA capacity of DG Sets with apple green tint for engine, smoke gray tint for alternator, black for foundation/bases frame and red for all guards including writing of SM/MES Number on Engine and Alternator all as specified and as directed by the Engineer-in-Charge.
Scraping, removal of rust and complete removal of existing painting, cleaning and applying spray painting with two coats of synthetic enamel paint after attending welding work to corroded portion over a coat of red oxide primer to the 12.5 KVA capacity of DG Sets with apple green tint for engine, smoke gray tint for alternator, black for foundation/bases frame and red for all guards including writing of SM/MES Number on Engine and Alternator all as specified and as directed by the Engineer-in-Charge.
Scraping, removal of rust and complete removal of existing painting, cleaning and applying spray painting with two coats of synthetic enamel paint after attending welding work to corroded portion over a coat of red oxide primer to the 7.5 KVA capacity of DG Sets with apple green tint for engine, smoke gray tint for alternator, black for foundation/bases frame and red for all guards including writing of SM/MES Number on Engine and Alternator all as specified and as directed by the Engineer-in-Charge.
M&L for winding of armature winding and field winding with super enamelled copper wire of appropriate gauge including varnishing of insulating material and heating up, testing etc, complete for DG set of capacity 40 to 62.5 KVA including taking out the old burnt windings. Installed at SFA Nandanam MES/SM No 108762 and STP inside Fort MES/SM No 013-6048-DG/06 all as specified and as directed by the Engineer-in-Charge.
M&L for repair /replacement for 12 Volts 92 AH includig cell and plate change for as per requirement and terminal and distal water complete all as specified and directed
M&L for repair /replacement for 12 Volts 180 AH includig cell and plate change for as per requirement and terminal and distal water complete all as specified and directed
Supply & fixing Ammeter 0 to 60 Amps complete all as specified and directed
Supply & fixing Voltmeter 0 to 500 V complete all as specified and directed
Supply & fixing1.5sqmm PVC insulated multistranded copper conductor control cable complete all as specified and directed. Make : Havells/Finolex
S& F for repair GI earthing strip 25x4 mm with nut and bolts comoplete including taking down old one all as specified and directed by Engr- in- Charge
S&F in repairs only 32 mm X 6 mm galvanised mild steel strip for horizontal conductors and down conductors including suitable design of fixing components of galvanised steel as per fig 28 of IS 2309: 1989 complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground( earth pit not less than 2.25 m deep below the normal groungnd level) with top edgee of the plate not less than 1.5m below normal GL connected to GI earth strip of size 32x6 mm by means of bolts, nuts, check nuts washers of GI or steel all as shown in electrical plate No-5 of SSR Part I connected to machanery/equipments installed power house/sub station all as specified including testing on completion. Note (i) the unit rate shall also include for excavation earth work in any type of soil PCC (1:3:6) type C1 pit RCC 1:2:4 type B-1 cover reinforced with 8 mm dia CTD bars @ 150mm C/C both ways funnel with 15mm bore GI watering pipe 20mm dia bore GI protection pipe wire mesh and copper lugs complete in addition to item No 1(a) to (e) of preamble ( Notes) Under sub heading earthing specified on SI page NO-389 of SSR Part-II 2004. (ii) Marking the earth chamber with date of test, name of machine and earth value.
Surface dressing not exceeding 15 cm deep in soft/ loose soil complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
Supply & spreading in trenches sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
Supply and laying well burnt bricks sub class 'B' in trenches for cable protection of U/G cable all as specified and directed by Engr-in-Charges.
Supply & Lay in repairs trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 70 sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
Supply & Lay in repairs trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 95 sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
Supply & Lay in repairs trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 150 sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
Supply & Lay in repairs trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 185 sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
Supplying & laying in repair 50 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & laying in repairs 80 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & laying in repairs trenches 100 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
M&L for Boring/Drilling (Horizontally) manually/mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubing of 40 to 100 mm bore complete all as specified and directed.
Repair/ overhauling of oil cooled servo controlled voltage stabiliser 3 phase 415 volts, 300 KVA by means of supply and replacement of complete wiring connection with suitable size of copper wire, switches, fuses, electronic card, bakalite connections, CTs for auxilary supply etc. Major spare required shall be measured and paid under respective items. Cost of minor spares incl cost of minor CTs for auxilary supply deemed to be included in the quoted rates complete all as specified and as directed.
S&F in replacement electronic card for reading of incoming and outgoing voltage complete all as specified and directed.
S&F in replacement resine based single phase feeding transformer suitable for 50/250/300 KVA servo voltage stabilize complete all as specified and directed.
S&F in replacement current transformer of ratio 100/5A complete all as specified and directed.
S&F in replacement AC synchronous motor (Servo motor) single phase 240 volts 50 Hz, 60 RPM having torque 10 Kg/cm complete all as specified and directed.
S&F in replacement Variac assy complete suitable for 3 phase 50/250/300 KVA voltage stabiliser complete all as specified and directed.
M&L for online centrifuging (filtration/ dehydration) of steplizer oil including checking di-electric strength of oil before and after filtration for steplizer with suitable machine having filtration, heating and pumping facility to improve the dielectric strength/ insulation value of oil. Notes :- (i) Di-electric strength of oil after filtration/ dehydration shall not be less than 60 KV/min. (ii) The contactor shall take shut down orders in writing from Engineer-in-charge before commencement of the work. (iii) The contractor shall ensure no wastage of stepliser oil. (iv) The di-electric strength of oil shall be tested before & after filtration and test results shall be submitted to Engineer-in-Charge.
Supply and filling new transformer oil for topping up the steplizer duly filtered with filtration plant having dielectric strength not less than 60 KV complete all as specified and as directed. [Make : Poweroil/ Electrol/ Servo]. Note :- (a) The steplizer oil shall be confirming to IS - 335/1983. (b) Mineral oil grade shall be used. (c) The IR value of transformer oil shall not be less than 60KV/min. (d) The unit rate shall be deemed to include the cost of filtration to achieve desired di-electric strength.
S&F in replacement of off load changeover switchs 4 pole, 63 Amps, 440 volts in and including sheet metal enclosur along with cable end termination adopter box all as specified and as directed by the Engineer-in-Charge.
S&F in replacement of off load changeover switchs 4 pole, 100 Amps, 440 volts in and including sheet metal enclosur along with cable end termination adopter box complete all as specified and as directed.
S&F in replacement of off load changeover switchs 4 pole, 63 Amps, 440 volts in and including sheet metal enclosur along with cable end termination adopter box complite complete all as specified and as directed.
S&F in replacement of off load changeover switchs 4 pole, 400 Amps, 440 volts in and including sheet metal enclosur along with cable end termination adopter box complete all as specified and as directed.
Supply and fix MCB, 4 Pole, 415 volts, 3 phase, 50 c/c, 63 Amps capacity including taking down the existing unserviceable one complete all as specified and as directed.
Supply and Fix MCB, Triple pole, 415 volts, 3 phase, 50 c/c, 40 amps capacity including taking down the existing unserviceable one complete all as specified and as directed.
Material and labour for PCC (1:3:6) type C-2 (using 40 mm graded aggregate) for filling and making good of disturbed surfaces of road/hard standing etc complete all as specified and as directed.
S&F MCCB adjustable thermal & magnetic setting 415V, 3 pole, 50Hz of capacity 63Amps 16 KA including taking out old u/s one complete all as specified and directed.
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 160 Amps 36 KA including taking out old u/s onecomplete all as specified and directed.
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 200 Amps 36 KA including taking out old u/s one complete all as specified and as directed.
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 250 Amps 36 KA including taking out old u/s one complete all as specified and directed.
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 350 Amps 36 KA including taking out old u/s one complete all as specified and as directed.
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 400 Amps 36 KA including taking out old u/s one complete all as specified and as directed.
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 500 Amps 36 KA including taking out old u/s one complete all as specified and as directed.
S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 630 Amps 36 KA including taking out old u/s one complete all as specified and as directed.
SHANTI ELECTRIC WORKS (BID ID -3353092)
Raj Enterprise (BID ID -3369668)
MAHANTA ENTERPRISES (BID ID -3353048)
Anil Kumar Sarmah (BID ID -3353079)
DRISTEE ASSOCIATES (BID ID -3353026)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .