Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.3 LAccepted-AOC PR CDA SC PUNE 01 THROUGH AO GE DEHU ROAD | L1 | Accepted-AOC Being lowest, L1 | |
| 2 | L2₹29.4 L+₹2.2 L (8.07%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹29.5 L+₹2.3 L (8.35%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹31.5 L+₹4.3 L (16.0%)Rejected-Finance CITY SURVEY NO 111 15 9 VIJAYA NAGAR KALEWADI PUNE 411 017 | PUNE | MAHARASHTRA | 411017 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹33.2 L+₹6.0 L (21.9%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
20 Jul 2024, 6:00 pmClosed
GE DEHU ROAD
GE DEHU ROAD, PUNE
REPAIRS OF NISSAN HUTS, SWTS, PLASTER, PLINTH PROTECTION, ROOF TREATMENT, FALSE CEILING, ROOF SHEETS, SANITARY FITINGS, BRICK WORKS AND OTHER MISC WORKS AT 29 FAD UNDER AGE B/R (EAST) AT GE DEHU ROAD
2024_MES_661486_1
8882
Open Tender
Civil Works
Item Rate
270 days
GE DEHU ROAD
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE DEHU ROAD
₹70,000
Yes
4 Sept 2024
22 Jun 2024
22 Jul 2024
22 Jun 2024
20 Jul 2024
6 Jul 2024
Amount
Dismantling plain or corrugated steel sheeting any gauge, any thickness including Nainital or similar pattern roof covering , in wall clading and velley gutters complete all as specified and directed.
S & F 0.50mm thick pre painted/coloured galvalum aluminium zinc coating GI based corrugated steel sheet of any colour in roofing having tensile strength 550 Mpa fixed with self tapping screws all as specifeed.
All as per item No. 02 above but plain sheet fix in valley gutter / ridge/ View cutter etc.complete all as specified and as directed.
Dismanteling MS works of any desc. not otherwise provided for complete all as specified and as directed.
S&F Tubular Sections as in main croos beams , hip and jack rafters; purlins, where connected to common rafter , posts etc. conf to Fe-410-w(gdeE-250 quality-A) complete all as specified and as directed.
S&F Roof truss framed trussed (angle) etc incl distance piece , cleats with necessery welding works etc Fe 410-W ( gde E-250)Quality A complete all as specified and as directed.
M &L for MS work as in wind tie or any other work incl cutting, drilling holes etc. complete all as specified and as directed.
Dismantling wall/ ceiling boards(fibre pulp insulation etc.) or insulations boards /slabs/blankets any thickness incl. cover fillets and alum snip grid.
S & F Anodised Alu. Snap grid 605x605 mm frame wk for false ceiling and providing 9mm th Acoustical board/tiles for insula-tion and accoustic purposes, 60x60 cm in size, fixed in celing with screws to frame work or with staples on snap grid including hangers 3 mm dia G.I. ( up to 1200 mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 X 3 mm size 60 mm long all as specified
M&L for false ceiling with 10mm thick of panel size 600mm x 900mm plaster of paris sheets fixed with machine screws on GI channel 18 gauge thick, grid work main joists placed at 750mm centres, secondary joists placed at 450mm centres, GI angle suspenders from roof and treating the plaster of paris sheets with thin layer of pop with Gypsum binder, sanding the surfaces till smooth surface is obtained including preparation of surface and applying two coats of oil bound distemper over a coat of primer all as specified and as directed.Make: Gyproc or Equivalent
M&L for plaster of paris decorative cornices/ moulding to the pattern as approved by Engineer in Charge, cross sectional area exceeding 13 Sq.cm and not exceeding 25 Sq.cm and fixed in decorative pattern including preparation of surfaces and applying two coats of oil bound distemper over a coat of primer matching with the colour of ceiling all as specified and as directed.
Dismantling floor hearth or wall tilling incl cement mortar beding (but not backing) & stacking at site as directed and disposing of debris to distance upto 250M complete all as specified and as directed.
M&L Coloured joint free Non skid ceramic tile 7 to 8 mm thk area of each tiles Exc 0.18 sqm & nexc 0.38 sqm as in floor set & jointed in neat cement slurry and pointed in white/colored cement laid over and including 15 mm thk in CM 1:6 complete all as specified and as directed.
All as per item No 13 above but on skirtings with & including 10 mm thick Backing Coat in CM (1:4) complete. complete all as specified and as directed.
M&L for Non-skid coloured Ceramic tiles of size 300 x 300 x 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles including 15mm thick Screed bed or bedding layer in CM 1:6 for laying floor finishes complete all as specified.
M&L for glazed coloured ceramic tiles 350 mm x 250mm/450mmx350x7 to 7 mm thick as in vertical surfces set & jointed in neat cement slurry & pointed in coloured cement to match over & including 10mm thick backing Coat in CM 1:4 complete all as specified and as directed.
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.11 Sqm but not exc. 0.18 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match to over & including 10mm thick screed bed in 15mm thick Screed bed in CM 1:6 for laying floor finishes complete all as specified and as directed.
All as per item No 17 above but on skirtings with & including 10 mm thick backing Coat in CM (1:4) complete all as specified and as directed.
M&L for vitrified coloured tiles 7 to 8 mm th (square/rectangular) polished area of each tile 0.30 sqm but n exc 0.42 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm th screed bed in CM 1:6 complete
Ditto above item No 19 but on skirting over 10 mm th rendering in CM 1:4 complete.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and as directed.
M&L for Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed no pigment to match the shade of the slab including rubbing and polishing complete all as specified.
M&L machine cut kota stone slab flooring 20-25mm thick over and including cement screed based 15 mm thick in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl cutting polishing and rubbing complete.
M & L for 20 mm thick Granite (of any type) tiles machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and including cement screed bed 15 mm thick in CM 1:6 complete all as specified and as directed.
M & L for 20 mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing with & including 10 mm th backing Coat in CM 1:4 complete all as specified and as directed.
Demolition of brick built in cement mortar complete all as specified and as directed.
M&L for brick work with sub class 'B' brick in cement mortar 1:6, straight or curved on plan exc 6 m mean radius, complete all as specified and directed.
Taking down cement plaster of any description on brick or stone walls/concrete surfaces, including racking out joints, hacking for key, scrubbing down with water etc.complete all as specified and as directed.
M&L for rendering 10 mm thick in CM 1:4 on new fair faces of brick work or concrete surface even and smooth without using extra cement all as specified and as directed by Engr-in-charge.
M&L for rendering 15 mm thick in CM 1:6 on new fair faces of brick work or concrete surface even and smooth using water proofing compound (WPC) & without using extra cement all as specified and as directed by Engr-in-charge.
Supply only integral water proofing compound complete all as specified and as directed.
M & L, applying two coats of oil bound distemper over one coat of primer including preparation of newly plastered surfaces of walls complete all as specified and as directed.
M&L for preparing new plastered surfaces & applying two coats of cement base paint on walls.complete all as specified and as directed.
M&L for preparation of new steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer.complete all as specified and as directed.
Demolition of concrete ( un reinforced ) in ground floors and paving n exc 15 cm thk (below or above ground level) complete all as specified and as directed.
M&L 75mm thick PCC 1:4:8 type D2 (40 mm Gr. Agg ) as in sub base. complete all as specified and as directed.
M&L for laying machine pressed precast concrete interlocking reflective coloured (Glozy Finish) pavers block any shape and size confirming to IS 15658-2006 of 55mm to 60mm thick, M-35 Grade over 30mm thick sand layer watering and ramming incl demolition of old tiles or blocks etc.complete all as specified.
M& L Chequared Cement Concrete (Glossy) Tiles 30 CM x 30 CM X 25 mm th set and jointed in cement slurry and pointed in neat grey cement & pigment in floors over screed bed 15 mm thk in cm 1:6 incl demolition of old tiles or blocks etc.complete all as specified.
M&L for PCC type B1(1:2:4, using 20mm graded stone aggregate) as in coping/ edging complete all as specified and as directed.
M&L for 75 mm thick cement concrete 1:3:6 type C2 (using 40mm graded stone agg.) as in plinth protection finished top surface even and smooth without using extra cement complete all as specified and as directed.
M&L for cement concerete 1:3:6 Type C-2 (Using 40 mm graded stone aggregate) as in surface channel and drain bed complete all as specified and as directed.
Extra for forming fair finished drain or channel up to 45 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.complete all as specified and as directed.
M&L for 40 mm thick cement conceret 1:2:4 type B-1, (20mm graded aggregate) as in surface channel & floor finish .complete all as specified and as directed.
Taking down wooden chowkat or frames with shutter (w/o taking off shutter from frame) of area exc 1.50 sqm and not exc 4 sqm each complete all as specified and as directed.
Ditto as above item no. 44 but n'exc 1.5 Sqm each. complete all as specified and as directed.
Taking down shutters of any description not exceeding 2 Sq. M each complete all as specified and as directed.
S&F for pressed steel frames size 125mm x 60mm for doors with double rebates incl necessary fixing lugs hinges lock strike plates etc complete all as specified and as directed.
Supply & Fixing PVC door frame (50x47) mm made out of plain colour 5 mm thich PVC Sheet reinforced with MS Square Tube, supplying & fixing in opening as per specification & drawing complete all as specified and as directed.
S&F factory made solid panel PVC door shutter 30 mm thick ( Style ) consisting of frame made out of MS Tubes for top & bottom rails.MS frame shall be covered with heat moulded plain colour PVC ' C 'Channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC Sheets for top rail , lock rail & bottomrail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC Sheet to be fitted in the MS Frame welded / sealed to stiles & rails with suitable PVC Sheet beading, jointed together with solvent cement,supplying & fixing in the frame at site as per specification & drawing.complete all as specified and as directed.
M & L for cement concrete (1:3:6) type C1(using 20mm graded stone agg.) as in door frame filling, hold fast etc including necessary form work and coping including weathering angles and throating as directed and necessary form work required complete all as specified and as directed.
S&F 30mm mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both side. all as per spd complete all as specified and as directed.
S&F, 35mm thick 2nd class hard wood glazed & skelton shutters, open repeated & prepared to receive glass, gauze etc. with sash bars, edges of framing plain, chamfered or rounded, fitted with cut or mitered beads for securing glass etc, sizes of members of shutters as specified in SSR part I, section 8, clause 8.24(a) Complete all as specified and as directed
S&F, 100mm long aluminium hinges complete all as specified and as directed.
S&F Aluminium door handle 125mm size cast type.complete all as specified and as directed.
S&F Aluminium anodized barrel tower bolt 150mm size. complete all as specified and as directed.
S&F 250mm long aluminium alloy, anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded section. complete all as specified and as directed.
S&F in repair 3 mm thick sheet glass, ordinary quality and glazing with oil putty or wooden bead in square n exc 0.50 sqm in each pane complete all as specified and as directed.
S & Fixed Stainless Steel wire cloth ,0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvalume Wire stapples complete all as specified and as directed.
M&L, applying two coats of synthetic enamel paint over a coat of pink primer including preparation of new wooden surfaces of any description over 10cm width or girth not otherwise described complete all as specified and as directed.
M&L for preparation old wooden surface and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation old steel surface and aplying one coat of synthetic enamel paint complete all as specified and as directed.
Taking up or down steel tubes and connections including cleaning for refixing or removal to stones bore of pipe 15mm. complete all as specified and as directed.
All as per item No. 62 above but bore of pipe 20 mm complete all as specified and as directed.
M&L GI tubes, medium grade with all fittings and fixed complete to walls, ceiling or laid in floors, bore of pipe 15mm complete all as specified and as directed.
All as per item No. 64 above but bore of pipe 20 mm complete all as specified and as directed.
Refixing of old steel tubing obtained from item no 60 and connections in new or old position (wall ceiling floor etc) 15 mm dia complete all as specified and as directed.
Refixing of old steel tubing obtained from item no 61 and connections in new or old position (wall ceiling floor etc) 20 mm dia complete all as specified and as directed.
Dismantling water tanks and removing to store up to 500 Ltr capacity. complete all as specified and as directed.
Dismantling water tanks and removing to store exc 500 Ltr but n. exc 1000 Ltr capacity. complete all as specified and as directed.
S&F rotational moulded Polythene (HDPE) double layer water tanks, cylindrical & vertical type 500 Litres capacity hoisted and fixed in position including provision of 20mm/15mm dia. spouts for connecting inlet, outlet, over flow and washout pipes.complete all as specified and as directed.
All as per item No. 70 above but 1000 litres. complete all as specified and as directed.
S & F in repair Ball brass valve, high pressure, with polythene float horizontal plunger type, IS-1703-2000 marked screwed to iron pipe or brass ferrule of size 20 mm bore complete all as specified and as directed.
M & L for taking out old water proofing treatment to RCC roof slab as specified below and as directed by Engr-in-Charge. (a) The Roof surface shall be thoroughly wire brushed washed dried up & cleaned to remove all foreign materials and dust to receive primer. (b) On the dried roof surface, apply one coat of bituminious primer @100gm/Sqm as per manufactueres instruction. (c) On this primed surface the approved APP modified bituminous membrane with non woven polyester mat asreinforcement weighing not less than 3.5 Kg/Sqm laid by torch applicatioon metho and top surface shall be applied with bituminous aluminium paint. (d) The overlap while torching shall be 75mm on longitudinal direction & 100mm on transverse direction. Note : Obtain material though out to low lying area.
Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes exc 500 & n exc 1000 ltr , etc.
S & F for 10/12 mm thick toughened glass with etching fixed with necessary Ozone patch touch fittings including openable door chamfered edge polishing as in bathing cubical / partitions including all fitting and fixture as per manufasture instructions etccomplete all as specified
S & F in repair for aluminium powder coated partition using 'Jindal' aluminium SP/DP section or equivelent make as specified with 5mm thick tinted glass, PVC rubber beading, 12mm thick prelaminated partical board fixed with glazing clips etc complete all as specified and as directed, section SP (single partition) -20033, DP (double Partition)- 20034, glazing clips -4407
M & L for 10 mm thick Polypan PS 20010 Prelam PVC (hallow profile) sheets used for fixing on wall Lining and PVC false ceiling inclusive of necessary fixing as directed by manufacturer and engr-in-charge.
H S TAKHI
RAMESH PATIL
M/S RENUKA CONSTRUCTIONS
KARPE AND SONS CONSTRUCTION
M/S B.A. GAIKWAD
Santhi Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .