Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.0 L+₹1.8 L (10.1%)Rejected-AOC 2 SURI LANE KOLKATA 700 014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L2 | Rejected-AOC L2 | |
| 3 | L3₹20.4 L+₹2.2 L (12.0%)Rejected-Finance | L3 | Rejected-Finance Being L3 bidder. | |
| 4 | L4₹21.4 L+₹3.2 L (17.7%)Rejected-Finance 133 GARFA MAIN ROAD KOLKATA 700 078 | KOLKATA | KOLKATA | WEST BENGAL | 700078 | L4 | Rejected-Finance Being L4 bidder. | |
| 5 | L5₹21.6 L+₹3.5 L (19.1%)Rejected-Finance | L5 | Rejected-Finance Being L5 bidder. |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
21 Jan 2020, 10:00 amClosed
Executive Engineer North 24 Pgs Electrical Divn
TOP FLOOR, MECHANICAL COMPLEX, BAGUIATI, KOLKATA 700 059
Renovation of E.I with ancillary works in Dr. B.R. Ambedkar Sports School, Banipur,North 24 Parganas.
2020_WBPWD_264102_1
WBPWD/EE/N24PRG/ELEC/112/19-20
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Banipur
Please refer Tender documents.
6 documents required · 6 mandatory
₹50,000
31 Aug 2020
6 Jan 2020
24 Jan 2020
7 Jan 2020
21 Jan 2020
7 Jan 2020
Amount
Part A: Installation of External light fittings at all buildings incl. compond illumination. SITC of 3 phase 415 V floor mounted free standing feeder piller box with 3.5 mm thick sheet steel enclosure with canopy and louver and hinged type double door with locking arrangement suitable for outdoor installation it should be supplied with all accessories ,base plate etc .The size of the pillar box is 1350X1000X600 MM (HXLXW) .The job shall be include all civil & structural material for erection at 200 mm above from ground level and repairing of damage surface.There should be provision inside the feeder of suitable size of (50mmX50mmX6 mm) angle iron frame for holding all the accesorries. Muffing:The above mentioned feeder box will be installed by providing 600X 1000X600 MM (HXLXW) brick work with cement plaster finish at both side. Incomer: 125A, 415 V TPN SFU with sheet steel enclosure(Make: Legrand/Crabtree/ABB) fixed by proper size nuts & bolts washers etc. BBC Chamber: Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on iron frame of the feeder pilar, incl. earthing attachment and painting as required – 4 bars 415 V, 315 A Dimension of Cu. bars (4 x 40x5mm) Dimension of Sheet Metal Box 500x150mm ----length 600 mm Outgoing: 63 A, 415 V sheet steel enclosure SFU with 3 nos HRC FUSE-8 NoS, 32 A, 415 V sheet steel enclosure SFU with 3 nos HRC FUSE-2 No, 4 way TPN DB consisting with 63A (Incomer Isolator) Outgoing (16 A SP MCB( 6 nos), 32 A SPMCB (6 nos) fixed by proper size nuts & bolts washers etc.on flat iron frame by suitable size drilled holes. S&F Timer control unit enclosure (equv.-2+8 way SPN DB) (make- Legrand/Crabtree/ABB) comprising with 1 no. 32A DP MCB isolator, 1 no. contactor unit, 1 no. analog time clock, 1 no. Miniature starter for manual operation & hinged type front door with interlocking arrangement and 1 no. indicator, 1no. terminal unit duly fixed on wall incl connection to G S.
Supply and Fixing of 70-72 W LED Street light fittings with IP66 protection.(Make- Philips/Crompton/Wipro/Jaquar) ,Cat No:BRP409 LED 074 CW HE MR FG S1 PSU GR or equivalent as directed by EIC).
Supply and Fixing of 35 W LED Flood light fittings with IP66 protection .(Make- Philips/Wipro/Trulux/Crompton) ,Cat No:BVP120 LED 35CW FG S1PSU GR or equivalent as directed by EIC).
Supplying and Fixing (250x200x100)mm GI water proof looping cable box havinghinged GI Top Cover having 4 mm thick with rubber gasketlining, railway type mechanical locking arrangement, earthingterminal with lug etc. of the following sizes as indicated below,Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL onporcelain insulator etc.
Fixing only Floodlight fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as required.
Supply & delivery of MS Steel tubular Pole Over all Length 7 mtr. Incl. painting the pole with one coat of aluminium paint over 1 coat RO priming and 2nd coat of aluminium paint over 1 st coat (make- Transrail/Subham/Tata/Jindal) (Designation 410 SP-03) or equivalent as directed by EIC.
Supply of MS Steel tubular Pole Over all Length 9 mtr. Incl. painting the pole with one coat of aluminium paint over 1 coat RO priming and 2nd coat of aluminium paint over 1 st coat (make- Tarnsrail/ Subham/ Tata/Jindal) (Designation 410 SP-29) or equivalent
Erection of Steel tubular pole of length 9.0 mtr/7 mtr. with sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly. Including Extra muffing on item above item , forproviding CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitablefor alkathene/ polythene pipe entry as directed for street light wiring, incl. S & F 25cmx25cmx10cm GI Loopbox, 16SWG & incl. drilled hole in pole with suitable size of PVC poltythene pipe for incoming and outgoing of cable for supply connection as per EIC.
Supply Delivery and fixing of double arm bracket of length 1 mtr, dia (As per site existing pole samle) with all through nuts and bolts etc as per necessary fixing arrangement.
S&F of 1.0 mtr 40 mm dia long MS/ Black pipe (16 swg) detachable arm bracket on pole for outdoor type LED light fittings inclu. S & F MS jacket (16 SWG) 300mm long befitting with 80mm dia GI pole incl. S & F of stiffering/ strengthening plate in between sleeve & arm bracket with suitable sized nut bolts as requirred incl. painting with synthetic enamel paint (2 coat) on 1 coat of red oxide primer.
In the errected pole, for providing CC (6:3:1) base block (around the pole) dimension 0.45x0.45x0.60 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, incl. S & F 20cmx15cmx10cm GI Loop box, 16SWG & incl. drilled hole in pole.
Supply & delivery of 1.1 KV Gr. XLPE/A. Al. Cable of under mentioned size. (Make: KEI/Finolex/Havells/Polycab) i) 4 core 120 sq mm (From Overhead pole to Feeder pilar incoming)
ii) 4 core 50 sq mm (From SFU 125A to Main building M.S)
iii) 4 core 16 sq mm (All Hostels, Staff Quarters Incoming cable)
iv) 4 core 10 sq mm (Compound light connecting cable)
Laying of one No. cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed i) 4 core 120 sq mm
ii) 4 core 50 sq mm
iii) 4 core 16 sq mm
iv) 4 core 10 sq mm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : i) 4 core 120 sq mm
ii) 4 core 50 sq mm
iii) 4 core 16 sq mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials i) 4 core 120 sq mm
ii) 4 core 50 sq mm
iii) 4 core 16 sq mm
iv) 4 core 10 sq mm
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Finolex/Havells/Polycab/KEI) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 22/0.3 (1.5 sqmm) (Fittings to terminal in loop box &building O/D light)
Supply & Fixing 240 V, 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required (For Building OD light control)
Supplying & fixing medium gauge 32 mm dia GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required.
Earthing with 50 mm dia By ISI-Medium GI pipe of 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level with excavation of soil for installation of Earth Electrode and filling & ramming.
PART B : Internal E.I. work - of Old Academic Building, & Miinimal repairing of internal electrical system of RMSA Building. Supplying and fixing of 415V,100A TPN SFU with fuse on L&N Sheet steel Main Switches on angle iron frame on wall (Make- L&T/Seimens/Havells).
Supplying and fixing 4 way double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment(Make: ABB/Legrand/Crabtree) I/C: 63A Isolator (1 no) O/G: 10-32A(12nos) (For Academic Building)
Supplying and fixing double-door 2+8 way SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment(Make : Legrand/Crabtree/ABB) I/C: 40A (1 no) O/G: 6-10A(8nos)(For Academic Building)
i) Supply & delivery of 4 core 35 sq mm 1.1 KV Gr. XLPE/A. Al. Cable of undermentioned size. (Make: KEI/Finolex/Havells/Polycab) ( Incoming cable upto Academic Building upto main Switch)
ii) 4 core 25 sq mm (From Main Switch to PBDB)
Laying of one No. 4 core 35 sq mm cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Laying of cable upto 4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Supplying & fixing medium gauge 25 mm dia GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : i) 4 core 35 sq mm
ii) 4 Core 25 Sq. mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials i) 4 core 35 sq mm
ii) 4 Core 25 Sq. mm
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/Havells/Polycab/KEI) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box,making earthing attachment, painting the MS box and mending good the damages to original finish.(Average run 8 mtr)
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/Havells/Polycab/KEI) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish. i) On Board
Distribution wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/Havells/Polycab/KEI) partly in 20mm size PVC rigid conduit 'FR' (Precision make) incl necy fitting as required. i)2 x 2.5 +1x 1.5 sq mm ( Power plug )
ii) 2 x 6 +1 x 4sq mm (From PBDB to SPNDB)
ii) 3 x 1.5 sq mm
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 6 Sq mm
S & F of 4ft. 20 watt LED polycarbonate T8 tube light with fitting as specified below complete with all accessries with all accessries with tube lamps from ceiling suspended 25 cm below the ceiling with 2 Nos. 20mm dia E.I conduit supports fixed 'L'typeM.S Clamp as per G.S as follow (make-Phillips/Crompton/Wipro), (Model. IGP161LT8-16 & LT8-20-865-(2) or equivalent as directed by EIC).
S& Fixing of 48” (1200mm sweep)AC Ceiling fan complete with all accessories ,without regulator as per GS (Orient Quasar/ Crompton Greaves Aura Prime).
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
Supply & fixing 9W LED lamp on batten point with angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceilingas per direction of EIC(Make:philips/Crompton/Syska).
S & F 12” sweep 1420 RPM AC Exhaust fan incl. making hole on wall with nuts & bolts as required with louver shutter as per GS (Make EPC Heavy duty)
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)
Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Anchor/Legrand/Hagar) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Anchor/Legrand/Hagar) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below By ISI-Medium GI pipe.
PART C : Electrical Installation work in Sentry room. Supply & Fixing only 240V ,16 A DP Sheet Steel Main Switch (Rewirwable type) on flat iron Frame on wall (Make: Havells/HPL)
Supplying and fixing 2 Way MCB SS enclosure with IP-20/30 protection, powder coated provision for two pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment
Supplying and fixing 240 V,10A DP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (make- Legrand/L&T/ABB).
Supply &delivery of 1.1 KV Gr. XLPE/A. 2core 6 sq mm Al. Cable of under mentioned size. (Make: Gloster/ Havells/Polycab/Finolex).
Laying of one No. cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed (From the Feeder pillar)
Supplying & fixing medium gauge 25 mm dia GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/Havells/Polycab/Glostar) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box,making earthing attachment, painting the MS box and mending good the damages to original finish.(Average run 8 mtr)
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/Havells/Polycab/Glostar) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish. i) On Board
ii) Average run 3 mtr
S & F of 4ft. 20 watt LED polycarbonate T8 tube light with fitting as specified below complete with all accessries with all accessries with tube lamps from ceiling suspended 25 cm below the ceiling with 2 Nos. 20mm dia E.I conduit supports fixed 'L'typeM.S Clamp as per G.S as follow (make-Phillips/Crompton/Wipro), (Model. IGP161LT8-16 & LT8-20-865-(2) or equivalent as directed by EIC).
Supply & fixing 9W LED lamp on batten point with angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceilingas per direction of EIC(Make:philips/Crompton/Syska).
S&F of 400 mm 1360 RPM wall mount bracket fan (Make: Crompton/Orient, Model no- SDX-Blackgold or equivalent as directed by EIC) on wall by rag bolts, nuts & washers (6 mm dia X 62 mm long) as required with necy connection.
Earthing with 50 mm dia By ISI-Medium GI pipe of 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level with excavation of soil for installation of Earth Electrode and filling & ramming.
PART D: Electrical Installation work inside the campus of Boys Hostel (One no) with compound illumination. Supplying and fixing of 125 A, 415V TPN SFU with fuse on L&N Sheet steel Main Switches on angle iron frame on wall.(Make: Havells/L&T/Seimens).
Supplying and fixing of 4 way double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make : Legrand/ABB/Crabtree). I/C: 63A (1 no Isolator 4 pole) O/G: 16-32A(12nos)
Supplying and fixing double-door 2+8 way SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment(Make : Legrand/Crabtree/ABB) I/C: 40A (1 no) O/G: 6-10A(8nos) (One no in GF, one no in FF)
Supply &delivery of 1.1 KV Gr. XLPE/A. Al. Cable of under mentioned size. (Make: Havells/Gloster/Finolex/Polycab) i) 4 core 50 sq mm (From Overhead pole to Main Switch)
ii) 4 core 25 sq mm (From Main Switch to PBDB)
Laying of one No. cable in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed i) 4 core 50 sq mm (From Overhead pole to Main Switch)
Laying of cable upto 4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : i) 4 Core 50 Sq. mm
ii) 4 Core 25 Sq. mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials. i) 4 Core 50 Sq. mm
ii) 4 Core 25 Sq. mm
Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Legrand/Hagar/Crabtree) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Legrand/Hagar/Crabtree) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/Havells/Polycab/KEI) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box,making earthing attachment, painting the MS box and mending good the damages to original finish.(Average run 8 mtr)
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/Havells/Polycab/Glostar) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish On Board
Distribution wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/Havells/Polycab/Glostar) partly in 20mm size PVC rigid conduit 'FR' (Precision make) incl necy fitting as required. i)'2 x 6 +1 x 4sq mm (From PBDB to SPNDB)
ii)2 x 2.5 +1x 1.5 sq mm ( Power plug & OD fittings)
iii) 3 x 1.5 sq mm
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 6 Sq mm
S& Fixing of 48” (1200mm sweep)AC Ceiling fan complete with all accessories ,without regulator as per GS (Orient Quasar/ Crompton Greaves - Aura Prime as directed by EIC)
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
S & F of 4ft. 20 watt LED polycarbonate T8 tube light with fitting as specified below complete with all accessries with all accessries with tube lamps from ceiling suspended 25 cm below the ceiling with 2 Nos. 20mm dia E.I conduit supports fixed 'L'typeM.S Clamp as per G.S as follow (make-Phillips/Crompton/Wipro), (Model. IGP161LT8-16 & LT8-20-865-(2) or equivalent).
S & F 12” sweep 1420 RPM AC Exhaust fan incl. making hole on wall with nuts & bolts as required with louver shutter as per GS (Make EPC Heavy duty)
Supply & fixing 9W LED lamp on batten point with angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceilingas per direction of EIC(Make:philips/Crompton/Syska).
Supply and Fixing of 35 W LED Flood light fittings with IP66 protection .(Make- Philips/Wipro/Trulux/Crompton) ,Cat No:BVP120 LED 35CW FG S1PSU GR or equivalent as directed by EIC).
Supplying and Fixing (250x200x100)mm GI water proof looping cable box havinghinged GI Top Cover having 4 mm thick with rubber gasketlining, railway type mechanical locking arrangement, earthingterminal with lug etc. of the following sizes as indicated below,Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL onporcelain insulator etc.
Fixing only Floodlight fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as required.
Supplying & fixing medium gauge 40 mm dia GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
Earthing with 50 mm dia By ISI-Medium GI pipe of 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level with excavation of soil for installation of Earth Electrode and filling & ramming.
MAHESWAR ELECTRICAL INDUSTRIES
SATABDI ENGINEERING COMPANY
Prava Enterprise
KANJILAL and SONS
RASH ELECTRICAL WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .