Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹26.3 L+₹1.5 L (5.99%)Rejected-Finance 32 GOLA MAHAL P O BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹26.6 L+₹1.8 L (7.22%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹27.2 L+₹2.4 L (9.50%)Rejected-Finance 106 1 RAJA RAMMOHAN SARANI KOLKATA 700 009 | KOLKATA | WEST BENGAL | 700009 | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹28.0 L+₹3.2 L (13.0%)Rejected-Finance | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
19 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
SPL REPAIRS TO B COY COOK HOUSE BLDG NO. NP-58/60A AND ADDN/ALTN TO BLDG NO. P-41 AT KANCHRAPARA MIL STN UNDER GE BARRACKPORE
2020_MES_365573_1
8448/E8
Open Tender
Civil Works
Item Rate
180 days
Barrackpore
Refer to tender documents
2 documents required · 2 mandatory
₹500
GE Barrackpore
₹48,000
Yes
18 Sept 2020
31 Jul 2020
21 Aug 2020
31 Jul 2020
19 Aug 2020
14 Aug 2020
60 days
Amount
Taking down chowkats with shutters (without taking off shutter from the frames) exceeding 1.50 Sqm and not exceeding 4.00 Sqm each complete all as specified and directed.
Taking down chowkats with shutters (without taking off shutter from the frames) not exceeding 1.50 Sqm each all as specified and directed.
Taking down of shutter of any description exceeding 1 Sqm and not exceeding 2.0 Sqm each all as specified and directed.
Taking down of shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm and refixing in same opening after easing and adjusting all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
S&F for anodised aluminum frame for doors , windows, ventilators with one or more rebates (of any type) including joining cleat for fixing etc complete all as specified and directed
S&F for anodised aluminum door shutters, aluminum section weighing 0.55 kg/m, including necessary joining cleat, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, roller, anodised aluminum snap beading screws, locking arrangement etc complete all as specified and directed.
S&F for anodised aluminium window/ventilators shutters, sliding (two track/three track) /fixed type/side hung type without sash bar, aluminum section weighing 0.55 Kg/m, including necessary joining cleat, glazing clips, rubber neoprene packing, handles, hinges, peg stay, anodised aluminium snap beading, screws etc complete locking arrangement, roller complete all as specified and directed.
S&F for aluminium extuded body door closer hydraulically regulated designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 85 Kg as complete all as specified and directed.
S&F for 4.8mm thick sheet glass panes, ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane complete all as specified and directed.
S&F for 4.8mm thick sheet glass panes, ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares exceeding 0.50 sqm each pane complete all as specified and as directed.
M&L for 12 mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination, fixed with screws to aluminum frame work complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlars facing dressed stonework & precast concrete articles complete all as specified and directed.
Demolition of cement concrete (unreinforcement) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Dismantling timber scantlings (framed work) 40 sq.cm and over in section, in any position complete all as specified and directed.
Demolition of reinforcement cement concrete of any description and in any position not otherwise specially provided for complete all as specified and directed.
Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Dismantling of asbestos cement (corrugated, semi-corrugated etc.) sheets in roof coverings complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description etc complete all as directed.
M&L for second class hard wood in scantling, clean swan as in frame work, fixed with nails complete all as specified and directed.
S&F for pressed steel frames for door (factory made) of size 165mm X 60mm of 1.25mm thick with one or more rebates including necessary fittings lugs, hinges, lock strike plate, etc including filling of concrete (1:3:6) type C-0 (using 12.50 mm graded aggregate) back of chowkhats and applying two coats of synthetic enamel paint over and including a coat of red oxide primer all as specified and directed.
S&F for pressed steel frames for door (factory made) of size 125mm X 60mm of 1.25mm thick with one or more rebates including necessary fittings lugs, hinges, lock strike plate, etc including filling of concrete (1:3:6) type C-0 (using 12.50 mm graded aggregate) back of chowkhats and applying two coats of synthetic enamel paint over and including a coat of red oxide primer all as specified and directed.
S&F for pressed steel frames for door (factory made) of size 105mm X 60mm of 1.25mm thick with one or more rebates including necessary fittings lugs, hinges, lock strike plate, etc including filling of concrete (1:3:6) type C-0 (using 12.50 mm graded aggregate) back of chowkhats and applying two coats of synthetic enamel paint over and including a coat of red oxide primer all as specified and directed.
S&F for 35mm thick (factory made) plain, second class hard wood, framed, panelled shutters (three panels) with lock rails and panel of 12 mm veneered particle board with commercial veneering on both faces (BWR type), the size of rail and stile as per IS-1003 (Part-I) (larger size to be provided) klin seasoned and chemically pressure treated fitted to chowkats complete all as specified and directed.
S&F for 30mm thick second class hard wood glazed/ gauge & skeleton shutters (factory made), open rebated & prepared to receive glass, gauge etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitered beads for securing glass etc. sizes of members of shutters as specified in SSR part-I, section-8, clause 8.24 (a) (larger size to be provided) complete all as specified and directed.
S&F for 35mm thick second class hard wood glazed/ gauge & skeleton shutters (factory made), open rebated & prepared to receive glass, gauge etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitered beads for securing glass etc. sizes of members of shutters as specified in SSR part-I, section-8, clause 8.24 (a) (larger size to be provided) complete all as specified and directed.
S&F for factory made solid PVC door frame of size 50mm X 47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube as per specification and drawing complete all as specified and as directed.
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) used as in brick, concrete wall for fixing of hold fast including necessary form work complete all as specified and directed.
S&F for steel windows with side hung shutters (glazed/gauged) including box type hinges with steel handle, frame, steel peg stay, complete without glazing bars, dovetailed or welded to receive wire mesh including one coat of red oxide zinc chrome primer at factory complete all as specified and directed.
S&F for steel windows with side hung shutters (glazed/gauged) including box type hinges with steel handle, frame, steel peg stay, complete with glazing bars, dovetailed or welded to receive glass, including one coat of red oxide zinc chrome primer at factory complete all as specified and directed.
S&F for stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm & fixed with stainless steel wire staple complete all as specified and directed.
S&F for stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm & fixed with stainless steel wire staple complete in repair all as specified and directed.
S&F for 3.0mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane complete all as specified and directed.
Hacking out old broken glass (any thickness size quality or description) from wooden or steel frame, glazed with putty or fixed with beads etc exceeding 1.5 Sqm complete all as specified and as directed.
M&L for second class hard wood in fillets, square, rectangular or triangular in section, clean swan, fixed with nails, sectional area not exceeding 3sqcm complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
M&L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in surface channel and drains etc complete all as specified and directed.
M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate), as in hard standing/plinth protection etc finishing cement concrete surfaces even & smooth without using extra cement complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm crushed stone graded aggregate) used as in slab supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed.
M&L for form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc for flat, rough finish surface of concrete complete all as specified and directed.
M&L for formwork to the soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200 mm thick (horizontal or sloping ) and making flat, rough finished surfaces of concrete complete all as specified and directed
M&L for TMT bars 6mm to 8mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 6mm to 8mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns (as in stirrups), hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 10 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding, fixed with self tapping screws complete all as specified and directed.
M&L for glazed ceramic coloured tiles (colour & shade as approved by GE) in vertical surface of size 450mmX 300mmX7 to 8mm thick set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick screed bed of cement mortar (1:4) complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured (colour & shade as approved by GE) tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in colour cement to match over and including 15mm thick Screed bed or beading layer of cement mortar (1:6) for laying floor finishes complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured (colour & shade as approved by GE) tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in colour cement to match over and including 15mm thick Screed bed or beading layer of cement mortar (1:4) for laying floor finishes after roughening the surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust and brushing neat cement slurry with 3.0 Kg of cement per Sqm complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured (colour & shade as approved by GE) tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in skirting/dado/riser of step etc set and jointed in neat cement slurry and pointed in colour cement to match over and including 15mm thick Screed bed or beading layer of cement mortar (1:6) for laying floor finishes complete all as specified and directed.
M&L for machine cut kota stone slab flooring (pre-mirror polished) 20-25mm thick over and including 15mm thick screed bed of cement mortar (1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for vitrified light shade (shade as approved by GE) ceramic tiles (ultra charge) 10mm thick (square/ rectangular) polished, area of each tile not exceeding 0.36 Sqm in floors etc set over and including 15mm screed bed in cement mortar (1:6) and jointed in neat cement slurry and pointed in white or coloured cement to match after roughening the surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust and brushing neat cement slurry with 3.0 Kg of cement per Sqm complete all as specified and directed.
M&L for vitrified light shade (shade as approved by GE) ceramic tiles (ultra charge) 10mm thick (square/ rectangular) polished, area of each tile not exceeding 0.36 Sqm in skirting etc set over and including 10mm thick rendering in cement mortar (1:6) and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10mm thick rendering in cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for 20 mm thick granite slab (of any type) machine cut in wall, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the of granite stone including grinding and polishing over and including 15 mm thick screed bed of cement mortar (1:6) complete all as specified and directed.
M&L for 20mm thick granite (of any type) tiles machine cut, in skirting/dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and including a backing coat of 10mm thick bedding in cement mortar (1:4) complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:3) on ceiling surfaces, finished fair and even complete all as specified and directed
M&L for rendering 15mm thick in cement mortar (1:6) on other than fair faces of brick works of surfaces, complete all as specified and directed.
M&L for rendering 20 mm thick, 1st coat 10mm thick in cement mortar (1:6) & 2nd coat 10mm thick in cement mortar (1:4) with water proofing compound @ 2% by weight of cement, plastered surface shall be finished even and fair with using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately, WPC shall be used in second coat only)
Supply only integral water proofing compound, ISI marked complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkaline resistant primer over 2 mm thick wall care putty on wall as directed by GE as per site condition after complete removal of existing treatment of wall including preparation of old painted wall surfaces complete all as specified and directed.
M&L for applying two coats of distemper oil emulsion over a coat of alkali resistant primer over and including applying 2 mm thick wall care putty after preparation of newly plastered surfaces of walls complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of alkali resistance primer on newly plastered surface of walls including preparation of surface complete all as specified and directed.
M&L for applying two coats of cement based paint on old plastered surface of walls as directed by GE after complete removal of existing treatment complete all as specified and directed.
M&L for applying three coats of white wash on surface of wall including preparation of new plastered surface complete all as specified and directed.
M&L for applying three coats of white wash on surface of ceiling including preparation of new plastered surface complete all as specified and directed.
M&L for two coats of white wash on old plastered surfaces of wall after preparation of old plastered surfaces of wall and complete removal of existing treatment all as specified and directed.
M&L for two coats of white wash on old plastered surfaces of ceiling after preparation of old plastered surfaces and complete removal of existing treatment all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer after preparation of new wooden surfaces of any description over 10 cm girth or width complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint after preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm in width or girth complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with two coats of cerosote oil complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over and including a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint after preparation of old painted steel surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and directed.
M&L for mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or forged into spikes; framed guard bars; barred iron doors; ladders, railings, framed brackets, walk ways, frame work of water tank and similar work conforming to Fe-290-0 Gde-E-165 complete all as specified and directed.
S&F for vitreous china wash basin, white, flat back, size 550mm X 400mm, excluding taps, chain and plug and porcelain stopper but including 32mm dia PVC waste pipe, brackets (02 Nos), 32mm size full threaded brass chromium plated waste coupling etc and cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed.
S&F for vitreous china wash basin, white, flat back, size 560mm X 450mm, excluding taps, chain and plug and porcelain stopper but including 32mm dia PVC waste pipe, brackets (02 Nos), 32mm size full threaded brass chromium plated waste coupling etc and cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed. (Make: Hindware Cat No. 10049 or equivalent of Cera/Parryware as approved)
S&F for vitreous china wash down water closet pan (pedestal pattern) white with P or S trap (excluding flushing cistern & flush pipe) including connection to trap & to flushing pipe, anti-syphonage pipe & seat cover etc. complete as in repair including making good to floor all as specified and directed.
S&F for vitreous china squatting pan 'Orissa' pattern, size 580x440mm white, with integral foot rests with P or S trap (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe etc complete including making good to floors with PCC bedding (1:5:10) type E2 using 40mm nominal brick ballast and connection to trap with cement mortar all as specified, and making good to floor including demolition of PCC / lime concrete bedding existing pan complete as in repairs all as specified and directed.
S&F for PVC connection pipe 15 mm size with PTMT nuts of length 600 mm complete all as specified and as directed.
S&F for 250 mm aluminium , sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts fixed complete all as specified and directed.
S&F for 150 mm size extruded aluminium handle, fabricated type complete all as specified and directed.
S&F for 100 mm size extruded aluminium handle, fabricated type complete all as specified and directed.
S&F for 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for 100 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for 100 mm long stainless steel butt hinges, medium weight complete all as specified and directed.
S&F for 50 mm long cold rolled mild steel butt hinges, medium weight complete all as specified and directed.
S&F for 100 mm long hasp and staple, mild steel, wire type, stove enamelled, black including bolt to hinge plate and fixed with screws complete all as specified and directed
S&F for 15 mm bore stop valve/angle valve, fancy type chromium plated with long shank and cup cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F for 15 mm bore stop valve/angle valve, fancy type chromium plated with long shank and cup cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete as in repair all as specified and directed.
S&F for 15mm dia pillar taps, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure, with letter 'HOT' or 'COLD' with long screwed shanks & fly nuts, screwed for iron pipes complete all as specified and directed.
S&F for 15mm dia pillar taps, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure, with letter 'HOT' or 'COLD' with long screwed shanks & fly nuts, screwed for iron pipes complete as in repair all as specified and directed.
S&F for 15mm dia bib taps, cast copper alloy with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferule, chromium plated with long screw type fixed complete all as specified and directed.
S&F for 15mm dia bib taps, cast copper alloy with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferule, chromium plated with long screw type fixed complete as in repair all as specified and directed.
S&F for brass chromium plated tubular towel rail, 20mm dia, D-type, 60cm long between flanges complete as in repair all as specified and directed.
S&F for 125mm size brass chromium plated shower roses with arms, swivel joints, including fixing to steel pipe or union complete as in repair all as specified and directed.
S&F for 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia 90cm long fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor complete all as specified and directed.
S&F for mild steel hold fast or wind ties etc made out of flat iron including tarring or coal tar black paint and with drilling necessary holes etc conforming to Fe 410-0 or Fe 310-0 all as specified and as directed.
Taking up or down steel tubings & connections including cleaning for refixing or removal from site for 15 mm bore pipes complete all as specified and directed.
Refixing old steel tubings & connections in new or old position (wall, ceiling, floor etc.) for 15mm bore pipes with new fittings etc complete all as specified and as directed. (Note : Pipe shall be obtained from Item No 103.00 above)
S&F for 15mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) complete all as specified and directed.
Taking up or down steel tubings & connections including cleaning for refixing or removal from site for 20 mm bore pipes complete all as specified and directed.
Refixing old steel tubings & connections in new or old position (wall, ceiling, floor etc.) for 15mm bore pipes with new fittings etc complete all as specified and as directed. (Note : Pipe shall be obtained from Item No 106.00 above)
S&F for 20mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) complete all as specified and directed.
M&L for cutting chases, in brick wall and making good to facing where required and pointing in cement mortar (1:3), to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth complete all as specified and directed.
S&F for false ceiling with exposed metal (PPGI) framework/ “Tee” Grid providing and fixing of suspended Tee gird false ceiling using “T” Gird System – powder coated GI (PPGI) exposed grid false ceiling suspension system in grid size 600mm x 600mm with main runner 32 x 24mm x 0.3mm thick, cross tee 26mm x 24mm x 0.3mm thick and wall angle 24mm x 24mm x 0.40mm thick using 4mm thick non asbestos fibre cement board (oceanic) of size 595 x 595mm, an asbestos Free fibre cement board manufacture using high Pressure System Curing technology. T gird Framing is suspended using 4mm GI/MS bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip, also providing provisions for light fixtures, air conditioning diffusers and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at not more that 300mm from the adjacent wall. 1220mm/600mm Cross Tee to be interlocked between main runners @ 600mm c/c, so as to from 600mm x 600mm or 1200mm x 600mm grid, confirming IS 14862 & type B category III of ISO 8336, tested as per AS 1530 part – 3 & B. S- 476 part 4,5,6,7 & 8 should be placed in Gird module to form after complete as per the drawing & directions of Engineer-in-Charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet all as specified and directed.
S&F for 500 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer (three layer) hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection including dismantling / taking down old PVC water tank, ball valve etc complete all as specified in SSR Part-I all as specified and directed.
S&F for 50mm bore low density polyethylene pipes (LDPE) of pressure rating 6kgf/cm2 fixed complete to wall or in floors etc. as in outlet pipe for WHB, urinal etc. complete all as specified and directed.
S&F for rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates including where required drilling, fittings, riveting or welding connecting with fish plate, gusset plates etc of Fe-410-W (Gde E-250) quality 'A' complete all as specified and directed.
S&F for sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F for curtain rail, chromium plated with bracket (fancy type), end bulbs (fancy type), stops, rollers etc complete all as specified and directed.
S&F for 25mm dia (heavy duty) chromium plated, single curtain rod (wall thickness not less than 1mm) including fancy type PVC powder type bracket, funnels etc suitable for single curtain rod complete all as specified and directed.
S&F for 300mm long, MS ordinary rat tail rod pattern spring including roller & roller plate complete all as specified and directed.
S&F for 16mm thick PVC solid board with one side decorative choice laminate and other side balancing white as in kitchen cabinet, cupboard etc fixed with screws to steel/timber frame work etc complete all as specified and directed.
S&F for 100mm bore sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints, fixed in wall with clamps and cement joints complete all as specified and directed.
S&F for 100mm bore sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints, fixed in floor and cement joints complete all as specified and directed.
S&F for 100mm dia CI branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S&F for 100 mm dia cast Iron bends (any radius) diminishing piece or tapers (larger bore measured) complete all as specified and directed.
S&F for salt glazed stone ware gully trap of size 150mmX100mm square or round moulded type 'P' complete all as specified and directed.
S&F for health faucet fixed to EWC with 1mtr long easy flexible tube and wall hook complete as in repair all as specified and directed. (Make: Jaquar Cat No.ALD-565 or equivalent of Marc/Kohler as approved)
M&L for sub main wiring (concealed) complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat and applying putty including cutting and cheasing complete all as specified and directed after taking down existing sub-main wiring of any type/size from wall and making good disturbed surface. (Note : Two run of 6 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of 25mm dia PVC conduit shall be measured as one unit)
Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty and white cement as necessary to holes for smooth finish surface complete all as specified and directed .
M&L for point wiring (concealed) complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of top cover , blanking plate as per numbers of switches, switch sockets, fan regulators, red colour indicator, blank plates etc as approved coloures accessories and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as box, top cover plate, blank plate, MS box, screws, washers and all electrical fixtures are to be used same make/brand only and shall be deemed in to included in quoted rate only.)
One light point controlled by one switch .
One fan point/ exhaust fan point controlled by one switch.
One 3 pin 5 amps socket outlet point on same board.
One 3 pin 5 amps socket outlet point on independent board.
All as per Item No.128.00 here-in-before but point wiring with 4.0sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm PVC insulated multistranded flexible copper conductor FR-LSH of 3 pin, 15 Amps socket outlet on independent board complete all as specified and directed .
S&F for 20 watt linear LED T8 tubular lamp with extruded aluminium/polycarbonate body and polycarbonate diffuser complete with inbuilt driver complete all as specified and directed. (Make: Crompton Greaves Cat No LTT8-20 /Havells Cat No TL20WLED865SPC OR PHOTONULTRA1213T8SSTL20WLED865 SPC as approved)
S&F for recess mounting 2'x2' LED 36 Watt light fittings with LED lamp and required driver, slimmest 9 mm thin in class LED ceiling panel with best in class aesthetic white powder coated frame blended seamlessly with ceiling layout suitable for 600X600mm modular ceiling grid and also can be suspended with provided kit and including connecting up with ceiling rose to fitting and including removing old unserviceable item complete all as specified and directed complete as in repair all as specified and directed, (Make: Crompton Cat No.LCPL-36-CDL(2x2) / Havells Cat No.ENDURASLIMPROPLUS2X2PLR36WLED857MOD as approved )
S&F for angle lamp holder, insulated body with back plate for batten fittings in and including LED lamp 12 watts complete all as specified and directed. (Make: Philips/Havells/Crompton Greaves as approved)
S&F for stepped type (0-4/5 step) electronic fan regulator 240 Volts, 100 Watts to 120 watts single pole, ISI marked including connecting, testing complete all as specified and directed.
S&F for socket out let, flush type, 2 in 1, 3/5 pin, 5/6 Amps, 240 volts, ISI marked, AC complete all as specified and directed.
S&F for switch piano flush button single pole one way 5/6 amp, 240 volts, AC, ISI marked complete all as specified and directed.
S&F for socket out let, flush type, 2 in 1, 3/5 pin, 5/6 and15/16 Amps, 240 volts, AC, ISI marked complete all as specified and directed.
S&F for switch piano flush button single pole one way 15/16 amp, 240 volts, AC, ISI marked complete all as specified and directed.
S&F for sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete including one single pole, MCB 20 Amp, 240V, 'C' series ISI marked complete as in repair all as specified and directed.
S&F for ceiling rose , surface bakelite 65X50mm, three terminal, polycarbonate body complete all as specified and directed.
S&F for rectangular block for mounting switches, sockets, fan regulator, tub light fittings, ceiling rose etc with 3mm thick plastic laminated sheet cover of size 100mmX100mmX50mm deep complete all as specified and directed.
S&F for powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 100amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat complete as in repair and all as specified and as directed. (Make: Legrand Cat No. 5076 21 8 way / Hager cat No.VYS08G / L&T Cat No.DBSPN008GD as approved)
S&F for powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 12 way for flush mounting with 100amps copper busbar, neutral bar, earth bar suitable for MCB incomer of rating upto 100Amps, MCB SPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plates with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete as in repair all as specified and as directed. (Make:- Legrand cat No. 5076 22 12 way / Hager cat No.VYS12G / L&T Cat No. DBSPN012GD as approved).
S&F for MCB, double pole, 40 Amps, 10 KA, "C" series, AC, 240 Volts, 50Hz, ISI marked complete all as specified and directed. (Make: Legrand Cat No.4086 37/ L&T Cat No.BB20400C or equivalent of Hager cat no as approved)
S&F for MCB, double pole, 63 Amps, 10 KA, "C" series, AC, 240 Volts, 50Hz, ISI marked complete all as specified and directed. (Make: Legrand cat No.4086 39/ Hager cat No. NCN463N / L&T Cat No. BB40630C or equivalent of Hager cat no as approved)
S&F for MCB SP 6 to 32 Amps 10 KA, "C" series, AC, 240Volts, 50Hz , ISI marked complete all as specified and directed. (Make:- Legrand Cat No. 4085 87 to 4085 95/Hager Cat No.NCN106N to NCN132N / L&T Cat No.BB20060C to BB20320C as approved)
M&L for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 5 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45X 45X 45 CM, RCC cover (1:2:4) type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value complete after taking down old earthing all as specified and directed. (Galvanised iron wire upto 7.5m including testing consider in this item).
M&L for XLPE insulated, LT armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade, cross-sectional area 25 sqmm, 2 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete after taking out old unserviceable cables from any position with serviceable bricks obtained from trenches complete all as specified and directed. (NOTE: Excavation/earth wall, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for XLPE insulated, LT armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade, cross-sectional area 25 sqmm, 4 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete after taking out old unserviceable cables from any position with serviceable bricks obtained from trenches complete all as specified and directed. (NOTE: Excavation/earth wall, sand cushioning, cable cover/brick shall be measured and paid separately if required)
Supply, fabricated and fixing of street light bracket made out of GI pipe 1.0 Mtr long, 40mm dia medium grade bent to shape as directed including clamps made out of 40 mm x 6 mm flat for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size after taking down old bracket including painting with one coat of aluminium paint over a coat of red oxide/primer complete all as specified and directed.
Taking down exhaust fan of any sweep after disconnecting electric connection, unscrewing nut/bolts from its position and dismantling of fan blade carefully from the exhaust fan and fixing the same to its original place or as directed after necessary cleaning, oiling, greasing, connecting wire from exhaust fan, ceiling rose connection complete all as specified and directed.
Taking down ceiling fan of 1200/1400 mm sweep after disconnecting electric connection, unscrewing nut/bolts from its position and dismantling of fan blade carefully from the ceiling fan and fixing the same to its original place or as directed after necessary cleaning, oiling, greasing, connecting wire from ceiling fan, ceiling rose connection complete all as specified and directed.
S&F for LED street light fittings Indus series IP-65 powder coated pressure die cast aluminium compact high power LED street light with heat resistant toughened glass of capacity 30 watt with LED lamp complete as in repair all as specified and directed . (Make : Crompton Greaves Cat No LSTS-30-CDL/ Havells Cat No ENDURACITYLITEPLATPLUSSL30W757SASYB0PC as approved)
Excavation in trenches for laying under ground cable, erection of poles and stays in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm soft/loose soil all as specified and directed.
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points as in soft/loose soil all as specified and directed.
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed
M&L for brick covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 125mm x 75mm laid dry flat complete all as specified and directed .
SENCO
MAZUMDER AND CO
M/S H.P Singha
N S CONSTRUCTION
DAS ENTERPRISE
S..S. ELECTRIC CO.
M/S. NAYABASTI CONSTRUCTION and SUPPLY SYNDICATE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .