| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.0 LAccepted-AOC 89 3 2 RANI MARKET VIVEKANANDA ROAD RISHRA HOOGHLY WEST BENGAL 712248 | HOOGHLY | WEST BENGAL | 712248 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹52.8 L+₹7.8 L (17.3%)Rejected-AOC | L2 | Rejected-AOC Being L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical AS PER ATTACHED DECISION DTD. 16/09/2023 |
Tender Value
₹58.5 L
EMD Value
₹1.1 L
Closing Date
17 Aug 2023, 2:00 pmClosed
General Manager, Ordnance Factory Chanda
Ordnance Factory Chanda
REPAIRING OF SUB - MAIN WIRING, DBS AND ALUMINIUM POINT WIRING ETC. IN TYPE - II OF SECTOR - II QUATERS IN ESTATE AREA AT O.F. CHANDA
2023_MIL_162108_1
OFCH/EO/08 OF 2023-24
Open Tender
Electrical Works
Item Rate
300 days
Ordnance Factory Chanda
As per attached tender documents
18 documents required · 18 mandatory
₹0
₹1.1 L
Yes
17 Jan 2024
25 Jul 2023
18 Aug 2023
25 Jul 2023
17 Aug 2023
25 Jul 2023
Amount
Cat (A) -Items to be supply and fixing
Taking down / dismantling of existing aluminium point wiring, main switches, cut-out carefully inside the DB and making good to disturbed surface of walls with proper filling & suitable colour wash as and where required etc. All as per the direction of Engineer In-charge
Supply and fixing piano Switch /bell switch flush type 5 Amp. Single pole one way (white) as per IS- 3854/ 1997 to be fixed on hylem sheet as per site requirement. Make: Anchor/cona /equivalent . All as per the direction of Engineer In-charge.
S&F, Socket outlet 5 pin 5 Amp. Flush type (white) on hylem sheet as per IS- 1293/1988 Make: Anchor /cona/equivalent, as per site requirement All as per the direction of E-I-C.
S&F, lamp holder, insulated body,suitable for 230 volt,6amp. Capacity with ISI mark threaded dome pattern, suitable for bracket fitting on a wooden board as per site requirement.Make :Anchor/cona/equivalent.All as per the direction of Engineer In-charge
S & F heavy duty stepped type electronic fan regulator flush type, 230 volt,50hz on the hylem sheet board as per site requirement. Make:cona/anchor/equivalent.All as per direction of E-I-C.
Supply and fixing LED tube light 1x 20 W, 120-300v ,50 hz with holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size with ceiling rose. LED tube light should be T8 ,4 feet with minimum 1800 lumens ,6500K colour temperature,to be fit on a good standard aluminium tube light patti, side holder of tube light patti should be metal type with holder for fixing tube light. Fitting to be fixed on wall with clamp or suitable fixing accessories as per site requirement. Tube light to be covered one year standard warrenty against defect from date of installation.Make of tube light :Philips/wipro/osram/equivalent. All as per direction of E-I-C.
Supply and fixingSwitch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal on a separate hyleem sheet wooden board as per site-requirement .Make :anchor /cona/equivalent.All as per of E-I-C.
Supply and fixing of Bell, AC, 230 volts, single pole on a wooden board.Make:cona/anchor/equivalent.All as per direction of E-I-C.
Supply and fixing white colour round shape Ceiling rose, PVC polycarbonate isolated body on a wooden board.Make:Anchor/cona/equivalent. All as per direction of E-I-C.
Supply and fixing Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size on the DB board. All as per direction of E-I-C.
S&Fixing of 8 way double door sheet metal single phase neutral MCB DB of 240 volt, 50hz with following items (A. Double pole MCB of 63 Amp.-1 no. as incomer B. 32Amp. single pole MCB-6 no. as out-going with ISI mark as per IS/IEC 60898-1)complete inside meter DB as per site requirement with all fixing accessories, after removing the individual meter and refixed the meter as per the DB position .Make:legrand/siemens/L&T/Equivalent.All as per the direction of Engineer-In-Charge.
S&Fixing of 8 way single door sheet metal single phase neutral MCB DB of 240 volt, 50hz with following items (A. Double pole MCB of 32 Amp.-1 no. as incomer B. 5-32Amp. single pole MCB-6 no. as out-going with ISI mark as per IS/IEC 60898-1)complete inside quarters as per site requirement with all fixing accessories on wall ,cable to be terminated with suitable lug.Make:legrand/siemens/L&T/Equivalent.All as per the direction of Engineer-In-Charge.
S&Fixing of 2 way single door sheet metal single phase neutral MCB DB of 240 volt, 50hz with following items (A. Double pole MCB of 63 Amp.-1 no. as incomer with ISI mark as per IS/IEC 60898-1 )complete inside DB as per site requirement with all fixing accessories.Make:legrand/siemens/L&T/Equivalent.All as per the direction of Engineer-In-Charge.
S&Fixing or drawing of sub-main cables of size 4.0 sq. mm. two single core of multi-coloured (2X4.0 sq. mm) PVC insulated ISI marked stranded copper conductor cables with continuous run of 1X2.5sq.mm. green colour pvc insulated copper Conductor cable as a Earth wire (Make:finolex/Havells/equvialent) cables as per IS-694-1990 drawing into steel conduit pipe on wall after removing the old pipe and cutting of holes in wall and concrete as per the site requirement , of any length with proper lug at termination end of cable . All as per the direction of Engineer In-charge.
Cutting of holes into cement concrete slabs of reinforcement through out not exceeding 100sq.cm. area with 15cm. depth for crossing of sub-main conduit pipe and refilling of gap with bonding of cement mortar 1:4 with suitable colour wash as and where required or as per site requirement.All as per direction of E-I-C.
S&F, One point wiring of 5 pin 5 Amp. Socket outlet point on same board with other switches, sockets with 2.5 sq. mm stranded copper Conductor PVC sheathed cables as per IS-694-1990 (make – Havells / Finolex) with all accessories. All as per the direction of Engineer-In-charge.
S&F, One light point, fan point, bell point, and independent plug pt. to be controlled with wiring of- (a) 2.5 sq. mm. colour coding Single core PVC insulated ISI marked Stranded copper Conductor cables as per IS-694-1990 (make: - Havells / Finolex). (b)PVC piping /PVC casing & capping with ISI mark, 1.8mm. to 2.2 mm. thick 19/25mm.size PVC pipe or casing &capping of 25/32 mm. width of size (make: cello/press fit/modi/finolex/super plast)& all accessories with joints, covers etc., (c)Continuous 1 sq.mm. Green colour pvc insulated suitable copper earth wire through inside the PVC pipe/pvc cassing & capping. (d)wiring to be terminated on a concealed M.S. Board with white hylem sheet of 2/3 mm. thick for fixing switches,sockets,regulators etc. with all civil related works like plastering,colour washing etc. All work as per the direction of Engineer In-charge .
Cat (B) - Buy Back Items
Credit to contractor for old/ damaged Single core pvc insulated aluminium conductor cable. All as per direction of E-I-C.
Credit to contractor for defective main switches/cut-outs and DBS. All as per direction of E-I-C.
Credit to contractor for defective switch,socket,holders etc. All as per direction of E-I-C.
HARIOM ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .