| 1 | L1₹69.6 LAccepted-AOC D NO LIG 98 RAJEEV NAGAR KURMANNAPALEM VISAKHAPATNAM 530 048 | VISAKHAPATANAM | ANDHRA PRADESH | 530048 | L1 | Accepted-AOC Lowest Bid Accepted | |
| 2 | L2₹88.5 L+₹18.8 L (27.0%)Rejected-Finance 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | L3₹93.2 L+₹23.5 L (33.7%)Rejected-Finance D NO 10 36 3 2 FLAT NO N 1 DASARATHA ENCLAVE RAM NAGAR VISAKHAPATNAM 530 002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | L3 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹78.5 L
EMD Value
₹1.4 L
Closing Date
10 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri VK Tiwari, IDSE, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
PROVISION OF CERTAIN EXTERNAL ELECTRICAL SERVICES TO BUILDING No. P-109 AND P-110 AT INHS KALYANI, VISAKHAPATNAM
2022_MES_516738_1
82245/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Visakhapatnam
Class C
Category b ii
9 documents required · 9 mandatory
₹1,000
Garrison Engineer Utility - I
₹1.4 L
Yes
17 Jun 2022
5 Apr 2022
17 May 2022
5 Apr 2022
10 May 2022
26 Apr 2022
12 Apr 2022 - 19 Apr 2022
60 days
Amount
Supplying, Installing, Testing and commissioning of Silent Diesel Engine driven Generating Set of Capacity 320 KVA / 256 KW, 415 Volts, Three Phase, 4 Wire, Engine as per IS – 10001 / 10002 and Alternator as per IS – 13364 complete with relay panel for automatic starting on main failure, control panel having meters, sound proof canopy as per relevant IS including provision of suitable foundation etc. comprising of the following: [A] ENGINE: Direct Injection, Water Cooled Engine, 8 Cylinder, in-line, 4 Stroke, rated at 1500 RPM, conforming to BS – 5514 and having following specifications: [i] In- line fuel pump with electronic governor for 320 KVA. [ii] Turbocharger [iii] Stainless Steel Exhaust Flexible Coupling and Exhaust Pipe duly insulated with Glass Fire Wool and Plain GI Sheet Cladding & extended outside the building. [iv] Silencer [v] Radiator [vi] Coolant Inhibitor [vii] Plate type Lub Oil Cooler [viii] Spin-On-Filters-Coolant, Fuel, Fuel & Lub Oil [ix] Dry type, Heavy Duty, Replaceable Paper Element Air Cleaner with Restriction Indicator [x] Flywheel Housing and Flywheel to suit Single Bearing Alternator [xi] Electrical Starter Motor [xii] Battery Charging Alternator [xiii] 2x12 Volts Batteries, 180 AH Capacity with multistranded copper cable for connecting leads and terminals [xiv] First fill of Lub Oil & Coolant
[B] ALTERNATOR: [i] Self Excited & Self Regulated [ii] Voltage Regulation ± 1 % [iii] Class H Insulation [iv] Salient Pole Revolving Field [v] Digital Automatic Voltage Regulator [Part of PCC 1301] [vi] Standard Enclosure IP-23 [vii] Telephone Interference Factor: 50 [viii] Total Harmonic Factor: Better than 2% [ix] Supplying power to variable electrical load for unlimited hours. Prime Power [PRP] is in accordance with ISO 8528. 10% over load capacity for one hour every 12 Hours of operation and will be suitable for tropical condition.
[C] ENGINE CONTROL WITH AMF PANEL: Standard Control Panel Cubicle with CRCA Sheet and angle iron structure shall be installed separately in Sub Station and shall comprise of the following accessories: [i] MCCB, FP, 36 KA, 450 Amps - 1 No with over load, short circuit protection. [ii] Contactor 4 Pole, 400 Amps capacity – 2 Nos [iii] Contactor 4 Pole 200 Amps capacity - 1 Nos for Neutral [iv] Microprocessor based LED type Multifunctional Intelligent Panel Meter for showing Current, Voltage, Frequency, Power Factor, Energy Consumed, Speed, Temperature of Engine, Oil Level, Battery Voltage etc., [v] Digital Frequency Meter – 1 No [vi] Digital Power Factor Meter with CTs – 1 No [vii] Three Phase, 400 / 5 CT Operated Digital KWH Meter 300 Amps – 1 No [viii] Indicating Lamps for "DG ON & LOAD ON" [ix] Instrument displaying Water Temperature, Lube Oil Pressure, Engine RPM, Battery Charging. [x] PVC Sleeve insulated Tinned Aluminium bus Bar suitable for 400 Amps current carrying capacity [TPN] [xi] Instrumentation, Control Switch Fuses / MCBs duly wired and ferruled. [xii] Coolant Heater with Thermostatic Switch [xiii] Lub Oil Heater
[D] FUEL TANK: In-Built Fuel Tank of suitable capacity for minimum 12 Hours run with all fittings and accessories. [E] ACOUSTIC ENCLOSURE: [i] Designed to meet stringent MOEF / CPCB & NBC 2016 norms 75 dBA @ 1 m at 75% load under free field conditions. [ii] Air Inlet Louvers shall be designed to operate at rated load even at 50°C Air Inlet Temperature. [iii] Cubicle shall be powder coated for long lasting service life and super finish with UV Resistant Powder Coating and shall withstand extreme environment. Stain Steel hardware shall be used. [iv] Insulation Material shall meet / conform to IS – 8183 Specifications for better sound attenuation [v] Provision of Genset Controller for Engine & Alternator. [F] ACCESSORIES: [i] Periodical Maintenance Tools as per Manufacture [ii] Operational, Spare Parts, & Installation Guidelines and Catalogue. Note: The Engine, alternator, Control Panel, Acoustic enclosure shall be integrated unit sourced from OEM only. Make of Diesel Generating Set Engines: Kirloskar Green / cummins / Ashok Leyland / Greaves Cotton Make of Alternator: Alstom / Crompton Greaves / Kirloskar Electric / Siemens / Bharat Bijlee / Stamford
Supplying, Installing, Connecting, Commissioning and Testing of Transformer, Step Down, Outdoor Type, complete with standard fittings and Trolley, 11 KV / 433 V [at No load], AC, 3 Phase, 50 Hz, of 800 KVA capacity, Double Copper Wound, Oil immersed, CRGO Core type Naturally cooled, Built-up with class "A" insulation, having Primary Voltage [HT] 11 KV and Secondary Voltage [LT] of 433 Volts, Delta connected on 11 KV Side & Star connected on 433 Volts side, designed & constructed with particular reference to Tropical Condition, conforming to IS – 1180-2014, Level-3 with latest amendment including fixing with bus bars/ Cables etc. complete all as specified and as directed and comprising of the following Specification and Fittings: Continuous Rating : 800 KVA No-Load Voltage Ratio : 11 KV / 433 V Tapping on HV [%] : ± 7.5, ± 5, ± 2.5 Phase & Frequency : 3 Phase & 50 Hz Connection : Delta Star Vector Group : DYN 11 Cooling : ONAN Type : Outdoor
Note: The Transformers shall also be provided with following Terminal Arrangement & Fittings and rate quoted shall be deemed to be included for the same: Terminal Arrangement: [a] HV & LV Side: Cable Box [b] Quad furcating cable box with five compression glands for PVC Cable and One additional neutral terminal shall be brought out separately for earthing purpose on LV Side. [c] First filling of new and unused Transformer Oil [IS – 335 Marked], filtered and tested up to 60KV dielectric strength at 2.5mm air gap between testing electrodes. Certification of dielectric strength shall be submitted by the Contractor after filling the oil. Transformer Oil shall be got tested by APEPDCL. [d] Apart from routine tests mentioned in these tender documents and relevant IS, pre-commissioning inspection of Transformer shall be carried out by Senior Electrical Inspector / Electrical Inspector.
Fittings: [a] Externally hand operated Off–Circuit Tap Switch with position indicator and locking device. [b] Conservator with Oil Gauge, filling hole with plug & drain hole with plug [c] Undercarriage with four plain rollers [d] Oil filling hole cum air release plug [e] Drain Valve cum Sampling Valve [f] Top Filter Valve with Plug [g] Rating Plate with Diagram Plate [h] Lifting lugs for Transformer [j] Lifting lugs for Core [k] Earthing Terminals [l] Thermometer Pockets [m] Silica Gel Breather [n] Explosion Vent [o] Double Float Buchholz with alarm and trip contacts including control cable of copper conductor of size & length from Marshalling Box to Relay of VCB [p] 150mm size Oil Temperature indicator, dial type with alarm and trip contacts [q] 150mm size Winding Temperature indicator, dial type with alarm and trip contacts [r] Buchholz Relay with 2 Shut-Off Valves [s] Marshalling Box with Double Window
Note: The rate quoted shall be deemed to include dismantling of existing LT panel of any description and size alongwith foundation base including provision of angle iron frame made of angles of size 75 X 75 X 8mm at Corners and ISMC of suitable size for base of Panel including provision of Platform with PCC 1:2:4, Type B–1 using 20mm grade stone aggregate, 600 mm below ground level and 600 mm above ground level.
S & F On-Load Changeover Switch, FP, 315 Amps, 415 Volts, 50 Hz, AC, Front Operated Handle, in sheet and including steel enclosure, with Advance Neutral and conforming to IS - 13947 [Part - 3] & IEC:60947-3 complete all as specified and as directed.
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, GI strip or wire armoured heavy duty HT underground cable, ISI marked with aluminium stranded conductor 11000 Volt grade of size 3 Core, 185 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. complete all as specified and as directed.
M & L for Cable End Termination Jointing Kit, Heat Shrinkable, Indoor type suitable for 11 KV [Earthed], 3 Core , 185 Sq.mm XLPE Power Cable with aluminium conductor complete all as specified and as directed.
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 300 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. complete all as specified and as directed.
All as described in Serial item No. 07 above but cable of size 3½ Core, 185 Sq.mm cross section
All as described in Serial item No. 07 above but cable of size 3½ Core, 70 Sq.mm cross section
All as described in Serial item No. 07 above but cable of size 3½ Core, 50 Sq.mm cross section
All as described in Serial item No. 07 above but cable of size 3½ Core, 35 Sq.mm cross section
All as described in Serial item No. 07 above but cable of size 4 Core, 35 Sq.mm cross section
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep in soft/ loose soil for foundation trenches, laying Pipes / Cables etc. complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
Removal of excavated material [Soil] to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m complete all as specified and as directed.
M & L for Dry River Sand cushioning over and around the cable for cable protection in trenches, levelled and punned down complete all as specified and as directed. Note: The punned down thickness shall be measured for payment.
Supply and lay Bricks, common burnt clay building bricks, sub–class "B", Designation 75 in trenches for cable protection complete all as specified and as directed.
Cutting existing Bituminous Road / Hardstanding etc. width not exceeding 200mm and depth not exceeding 300mm for Laying Cables and protection Pipes and making good by refilling the trench with PCC 1:2:4, Type B1 using 20mm graded stone aggregate complete all as specified and as directed.
Supplying and laying GI pipe, 100mm dia, Light grade for cable protection at road crossing etc. or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed.
Supplying and laying GI pipe, 80mm dia, Light grade for cable protection at road crossing etc. or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed.
Supplying and laying GI pipe, 50mm dia, Light grade for cable protection at road crossing etc. or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed.
M & L for PCC 1:4:8, Type D-2, using 40mm graded stone aggregate as in Foundation, Fillings, Mass concrete, Footings etc complete all as specified and as directed.
M & L for Plain Cement Concrete Type C1 [Nominal Mix] 1:3:6 using 20mm graded stone aggregate Platform/ pole foundation/ copings, cable ducts and similar works as directed including use and waste of necessary form work complete all as specified and as directed.
M & L for Earthing complete with Copper Earth Plate Electrode 600 X 600 X 3.15 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to Copper Strip of size 20 X 3mm [Earth Lead] and GI pipe 40 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed.
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed.
S & F Earth continuity Conductor or main earthing lead made of GI Strip of size 32 X 6mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
Prasur Electricals & Engineering Co.
eldi techs
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .