Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 LAccepted-AOC ELAVANCHERRY GP PALAKKAD | PALAKKAD | KERALA | 672122 | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical CONTRACTOR LSGD PATHANAPURAM PUNALUR KERALA | KOLLAM | KERALA | 689695 | - | Rejected-Technical L4 | |
| 3 | Rejected-Technical | - | Rejected-Technical L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical L2 |
| Sl No | Description | Qty | Unit | Suresh K L1 | MANOJ M L4 | SANTHOSHKUMAR.S L2 | Ratheesh L3 |
|---|---|---|---|---|---|---|---|
| 1.00APPENDIX A :- CIVIL WORK - CONSTRUCTION OF TEMPORARY PUMP HOUSE | |||||||
| 1.00 | 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared | 16 | sqm | 15.4 ₹246.4 Lowest | 17.65 ₹282.4 | 17.46 ₹279.36 | 17.65 ₹282.4 |
| 1.00 | 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | 6.72 | cum | 309.99 ₹2,081.89 Lowest | 348.93 ₹2,343.41 | 345.33 ₹2,319.24 | 348.93 ₹2,343.41 |
| 1.00 | 100.41.39:Supply, stacking, spreading and consolidating of Quarry Muck in the trench of pipe line, including carriage, loading, unloading & stacking up to any lead. | 30.44 | cum | 558.88 ₹17,012.31 Lowest | 659.42 ₹20,072.74 | 652.61 ₹19,865.45 | 659.42 ₹20,072.74 |
| 1.00 | 4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) | 1.1 | cum | 7,113 ₹7,795.85 Lowest | 7,694.91 ₹8,433.62 | 7,614.68 ₹8,345.69 | 7,694.91 ₹8,433.62 |
| 1.00 | 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete | 114.97 | kg | 159 ₹18,280.55 Lowest | 190 ₹21,844.68 | 179.56 ₹20,644.37 | 181.44 ₹20,860.52 |
| 1.01 | 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) | 1.84 | cum | 8,900 ₹16,340.4 Lowest | 10,174.11 ₹18,679.67 | 10,068.44 ₹18,485.66 | 10,174.11 ₹18,679.67 |
| 1.01 | 5.22.1:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars | 146.07 | kg | 90 ₹13,146.12 Lowest | 108.2 ₹15,804.56 | 107.07 ₹15,639.5 | 108.2 ₹15,804.56 |
| 1.01 | 50.6.1.7:Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15 cm in : CM 1:6 ( 1 cement : 6 coarse sand ) etc complete | 2.88 | cum | 6,357 ₹18,308.16 Lowest | 6,604.77 ₹19,021.74 | 6,536.67 ₹18,825.61 | 6,604.77 ₹19,021.74 |
| 1.01 | 50.6.2.1:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete | 0.22 | cum | 6,373 ₹1,376.57 Lowest | 6,626.21 ₹1,431.26 | 6,557.89 ₹1,416.5 | 6,626.21 ₹1,431.26 |
Tender Value
₹6.7 L
EMD Value
₹16,721
Closing Date
29 Sept 2025, 2:00 pmClosed
ASST EXECUTIVE ENGINEER
WSP SUBDIVISION HARIPPAD
DEPOSIT WORK 2025-2026-THRIKKUNNAPUZHA GRAMAPANCHAYATH-CONSTRUCTION OF TEMPORARY PUMP HOUSE LAYING PUMPING MAIN SUPPLY AND ERECTION OF PUMP SET AND COMMISSIONING NEW TUBE WELL BASED WSS IN WARD 16 NORTH - EAST OF PALLANA H.S IN THRIKKUNNAPUZHA
2025_KWA_798392_1
WRD/KWA-CE(CR)/TR/15014/2025
Open Tender
Civil Works - Water Works
Item Wise
90 days
WSP SUBDIVISION HARIPPAD
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,475
₹16,721
10 Oct 2025
17 Sept 2025
30 Sept 2025
17 Sept 2025
29 Sept 2025
17 Sept 2025
Amount
APPENDIX A :- CIVIL WORK - CONSTRUCTION OF TEMPORARY PUMP HOUSE
2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
100.41.39:Supply, stacking, spreading and consolidating of Quarry Muck in the trench of pipe line, including carriage, loading, unloading & stacking up to any lead.
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
5.22.1:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars
50.6.1.7:Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15 cm in : CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
50.6.2.1:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
50.2.25.1:Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
12.1.3:Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/m2
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
9.95.3:Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete:100x75x4 mm
9.97.3:Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm
50.9.15.1:Supplying and fixing 200 mm Aluminium aldrop
APPENDIX B :- CONSTRUCTION OF PUMP HOUSE - ELECTRIFICATION WORK.
OD72704/2025-2026:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface I recessed mediumclass PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper Group B conductor single core cable etc. as required
OD72703/2025-2026:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with lSI marked HRC fuses including drilling holes in cubiclepanel, making connections, etc. as required. 63ATP&N
OD72706/2025-2026:Earthing with G.l. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate Jlaving locking arrangement and watering pipe etc. with charcoal/coke and salt as required
OD72705/2025-2026:Installation, testing and commissioning of pre-wired, fluorescent fitting I compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc.directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required
OD72707/2025-2026:Supplying fluorescent lamp set 36/40 W with all accessories
OD72701/2025-2026:Supplying and fixing metal box of 200 mm X 125 mm X 60 mm size (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
OD72702/2025-2026:Supplying and providing meter box and panel board for KSEB supply and providing necessary fuse unit and isolators for 3 phase supply as per the direction of departmental officers.
APPENDIX C :- LAYING PUMPING MAIN - WORKING CHARGES.
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.98.1008:Engaging Coolie.
100.9.8:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes.
OD75883/2025-2026:Jointing the newly laid PVC pipe of size 90 mm with newly laid 80 mm GI line by cutting and removing the end existing line and jointing newly laid line with existing line using necessary specials such as couplings / reducers/ Tee and making a water tight joint including all labour charges, cost and conveyance of all specials, conveyance of specials from section store but excluding cost of CID/CIR joints etc complete as per the direction of engineer in charge
OD72713/2025-2026:Inter connection /Jointing the newly laid PVC pipe of size 90 mm with existing 63/75/90mm PVC line by cutting and removing the end existing line and jointing newly laid line with existing line using necessary specials such as couplings / reducers/ Tee / CIR Joint and making a water tight joint including all labour charges, cost and conveyance of all specials etc complete as per the direction of engineer in charge.
100.31.1.1:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 80mm diameter, Class I.
OD146567/2025-2026:Constructing valve chamber of inner size 1.0 m x 1.0 m x 1.5 m in M-25 grade cement concrete for reinforced cement concrete work and 10 mm MS rod(115 Kg) for Base slab & side wall and 12 mm MS rod (102 Kg) for cover slab.(Base slab 1.3 mx1.3 mx0.15 m,side wall 15 cm thick, cover slab 3 Nos of size 1.3 mx0.0.42 m x 0.15 m)over a PCC base of size 1.5 mx1.5 mx0.10 m in 1:3:6 using 40 mm broken stone, plastering inside the valve chamber and cover slab in CM.1:3, 6 mm thick including cost and conveyance of all materials etc.complete. as per the direction of departmental officers in charge
100.47.1.4:Leak rectification work in 63mm uPVC (Class 2 to 6) pipeline including detecting and locating leak, earthwork excavation in all kinds of soil for exposing leak portion of the pipe including tar cutting / concrete cutting, cutting the pipe diametrically perpendicular to the axis of pipeline without causing any damages to the remaining portion, dismantling and lifting the pipe from trenches, smoothening the cut ends, conveying the new pipe to the site, cutting and lowering new pipe into the trenches, placing in position, aligning the pipe to line and level and jointing the new pipe with the existing pipe with solvent cement or any available joint and testing the pipeline by operating the valves concerned, and rectifying the defects if noticed and without causing any damages to the existing utilities and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards, lighting, watching, ribbon fencing, traffic controlling etc., complete as per the direction of Departmental officers including the cost of pipe and uPVC specials; uPVC Pipes and specials shall be of good quality and conforming to relevant standards: All Socketed Jointing.
100.47.1.5:Leak rectification work in 75mm uPVC (Class 2 to 6) pipeline including detecting and locating leak, earthwork excavation in all kinds of soil for exposing leak portion of the pipe including tar cutting / concrete cutting, cutting the pipe diametrically perpendicular to the axis of pipeline without causing any damages to the remaining portion, dismantling and lifting the pipe from trenches, smoothening the cut ends, conveying the new pipe to the site, cutting and lowering new pipe into the trenches, placing in position, aligning the pipe to line and level and jointing the new pipe with the existing pipe with solvent cement or any available joint and testing the pipeline by operating the valves concerned, and rectifying the defects if noticed and without causing any damages to the existing utilities and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards, lighting, watching, ribbon fencing, traffic controlling etc., complete as per the direction of Departmental officers including the cost of pipe and uPVC specials; uPVC Pipes and specials shall be of good quality and conforming to relevant standards: All Socketed Jointing.
100.47.1.6:Leak rectification work in 90mm uPVC (Class 2 to 6) pipeline including detecting and locating leak, earthwork excavation in all kinds of soil for exposing leak portion of the pipe including tar cutting / concrete cutting, cutting the pipe diametrically perpendicular to the axis of pipeline without causing any damages to the remaining portion, dismantling and lifting the pipe from trenches, smoothening the cut ends, conveying the new pipe to the site, cutting and lowering new pipe into the trenches, placing in position, aligning the pipe to line and level and jointing the new pipe with the existing pipe with solvent cement or any available joint and testing the pipeline by operating the valves concerned, and rectifying the defects if noticed and without causing any damages to the existing utilities and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards, lighting, watching, ribbon fencing, traffic controlling etc., complete as per the direction of Departmental officers including the cost of pipe and uPVC specials; uPVC Pipes and specials shall be of good quality and conforming to relevant standards: All Socketed Jointing.
100.57.1:Rectifying the leakages in boring point of public tap connection including earth work excavation in all kinds of soil for exposing the boring point including concrete / tar cutting, dismantling the damaged saddle piece,cutting and removing damaged portion of pipe line,fixing new saddle piece,laying 20/25 mm PVC 10Kg/cm2 pipe in place of damaged portion of pipe and connecting with existing pipe line,testing the line to the required test pressure, rectifying any defects noticed and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, removing the surplus soil from the work site, without causing any damages to any other utilities, including the charges of hire and conveyance of tools, plants and materials to the leak site, bailing out water, lighting, watching, ribbon fencing, caution boards, traffic diversion, including cost of pipe and saddle piece and as per the direction of departmental officers etc. complete.
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
4.1.4:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources)
APPENDIX D :- LAYING PUMPING MAIN - COST OF MATERIALS
100.98.236:Supply of PVC Pipe, 10kg/cm2, 90mm Dia.
100.98.481:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 80mm.
OD73851/2025-2026:Supplying 90 mm PVC Tee
OD73852/2025-2026:Supplying 90 mm PVC Bend
APPENDIX E :- SUPPLY, ERECTION AND COMMISSIONING OF SUBMERSIBLE PUMP SET
OD72716/2025-2026:Supplying 80 mm GI Class B pipe (weight not less than 8.5 Kg/m) having ISI mark
OD72718/2025-2026:Supplying good quality 80mm GI BEND
OD72719/2025-2026:Supplying 80mm GI Tee
OD72722/2025-2026:Supplying 3X4mm sq. submersible cable having ISI mark
OD72721/2025-2026:Supply and Fixing of Dosing pump having 4 Kg/ 6 LPH discharge and delivering pressure and arrangements for injecting bleaching powder solution directly to the pumping line at suitable point and wiring from existing panel board to the pump set using power cables encased in PVC conduit and accessories including angle stand to fix the pump set and storage tank, best quality PVC storage tank with cover and suitable locking arrangements, tank capacity 200 L and 300 L (E Dose/ UKI Make) for storing solution along with Supply of liquid chlorine (10% to 15% concentration) .
SANTHOSHKUMAR.S (BID ID -2360034)
Ratheesh (BID ID -2360880)
MANOJ M (BID ID -2360968)
Bidder Name
SANTHOSHKUMAR.S
Ratheesh
Suresh K
MANOJ M
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1323162.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .