Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹73.8 LAccepted-AOC B 148 2ND FLOOR B BLOCK NEAR MOTHER DIARY SECTOR 8 DWARKA NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | ₹73.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹74.4 L+₹62,785 (0.85%)Rejected-Finance | ₹74.4 L+₹62,785 (0.85%) | L2 | Rejected-Finance L2 |
| 3 | L3₹76.0 L+₹2.2 L (2.92%)Rejected-Finance FLAT NO 203 KADIRIS APURUPA URBAN 2 ND FLOOR LAXMI NAGAR BOTANICAL GARDEN ROAD KONDAPUR HYDERABAD 500084 RANGAREDDI TELANGANA 500084 | HYDERABAD | TELANGANA | 500084 | ₹76.0 L+₹2.2 L (2.92%) | L3 | Rejected-Finance L3 |
| 4 | L4₹76.1 L+₹2.3 L (3.13%)Rejected-Finance | ₹76.1 L+₹2.3 L (3.13%) | L4 | Rejected-Finance L4 |
| 5 | L5₹79.1 L+₹5.3 L (7.16%)Rejected-Finance | ₹79.1 L+₹5.3 L (7.16%) | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
Closing Date
31 May 2021, 6:00 pmClosed
Asst. General Manager (Engg-Electrical)
Airports Authority of India, Rajahmundry Airport, Madhurapudi Post, Rajahmundry-533102
SITC of Apron Flood Lighting High Masts, LT Panels and Allied Electrical Works at Rajahmundry Airport
2021_AAI_77591_1
AAI/RJY/ENGG(E)/NIT-01/2021-22
Open Tender
Electrical Works
Item Rate
180 days
Airports Authority of India, Rajahmundry Airport
Please refer Tender Document
13 documents required · 13 mandatory
₹1,180
Exempted
18 Oct 2021
17 May 2021
2 Jun 2021
17 May 2021
31 May 2021
17 May 2021
17 May 2021 - 31 May 2021
Amount
Design,Fabrication,Supply, Installation, Testing and commissioning of High mast shaft of 25 mtrs in Three sections, hot galvanized Steel plates confirming to BSEN 10025:1993 suitable for wind speed as per IS:875,part 3 with raising lowering system comprising, head frame, lantern carriage suitable to install Minimum 14 Nos. 350 W LED luminaries in symmetrical arrangement, double drum winch, 6 mm diameter SS wire rope, Two number 5C X 2.5 Sq.mm tinned unarmoured copper conductor EPR insulated & PVC sheathed trailing cable from Junction Box of lantern carriage to control panel, one number 3CX4 Sq.mm, PVC insulated, PVC sheathed unarmoured Copper conductor cable for Power tool from control panel, connectors, 415 V, 32 A, 3P+N+E Plug & Sockets, integral power tool motor with mechanically tripping facility & manual handle, terminations Junction Box, lightening finial including the followings.High mast tower shall conform to tender specification & as required complete in all respects. Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template. Construction of shallow foundation with M25 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour. Erection of the high mast including all accessories with the help of suitable tools and plants. Installation, testing and commissioning of 350 W LED Flood lights upto 14 No's or as per site requirements and 01 No. Twin Type aviation obstruction light on the existing lantern carriage including wiring of all luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 2.5 sq. mm from Junction Box of Lantern Carriage to individual light fittings, lugs, mounting accessories and all labour etc.
Design, Fabrication,Supply, Installation, Testing and commissioning of High mast shaft of 19 mtrs in minimum Two sections, hot galvanized Steel plates confirming to BSEN 10025:1993 suitable for wind speed as per IS:875,part 3 with raising lowering system comprising, head frame, lantern carriage suitable to install Minimum 12 Nos. 350 W LED luminaries in asymmetrical arrangement, double drum winch, 6 mm diameter SS wire rope, Two number 5C X 2.5 Sq.mm tinned unarmoured copper conductor EPR insulated & PVC sheathed trailing cable from Junction Box of lantern carriage to control panel, one number 3CX4 Sq.mm, PVC insulated, PVC sheathed unarmoured Copper conductor cable for Power tool from control panel, connectors, 415 V, 32 A, 3P+N+E Plug & Sockets, integral power tool motor with mechanically tripping facility & manual handle, terminations Junction Box, lightening finial including the followings.High mast tower shall conform to tender specification & as required complete in all respects. Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template. Construction of shallow foundation with M25 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour. Erection of the high mast including all accessories with the help of suitable tools and plants. Installation, testing and commissioning of 350 W LED Flood lights upto 12 No's or as per site requirements and 01 No. Twin Type aviation obstruction light on the existing lantern carriage including wiring of all luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 2.5 sq. mm from Junction Box of Lantern Carriage to individual light fittings, lugs, mounting accessories and all labour etc.
Design, Fabrication, Supply, Installation, Testing and commissioning of High mast shaft of 18 mtrs in minimum Two sections, hot galvanized Steel plates confirming to BSEN 10025:1993 suitable for wind speed as per IS:875,part 3 with raising lowering system comprising, head frame, lantern carriage suitable to install Minimum 12 Nos. 350 W LED luminaries in asymmetrical/symmetrical arrangement, double drum winch, 6 mm diameter SS wire rope, Two number 5C X 2.5 Sq.mm tinned unarmoured copper conductor EPR insulated & PVC sheathed trailing cable from Junction Box of lantern carriage to control panel, one number 3CX4 Sq.mm, PVC insulated, PVC sheathed unarmoured Copper conductor cable for Power tool from control panel, connectors, 415 V, 32 A, 3P+N+E Plug & Sockets, integral power tool motor with mechanically tripping facility & manual handle, terminations Junction Box, lightening finial including the followings.High mast tower shall conform to tender specification & as required complete in all respects. Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template. Construction of shallow foundation with M25 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour. Erection of the high mast including all accessories with the help of suitable tools and plants. Installation, testing and commissioning of 350 W LED Flood lights upto 12No's or as per site requirements and 01 No. Twin Type aviation obstruction light on the existing lantern carriage including wiring of all luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 2.5 sq. mm from Junction Box of Lantern Carriage to individual light fittings, lugs, mounting accessories and all labour etc.
Design,Fabrication, Supply, Installation, Testing and commissioning of High mast shaft of 12 mtrs in single sections hot galvanized Steel plates confirming to BSEN 10025:1993 suitable for wind speed as per IS:875,part 3 with raising lowering system comprising, head frame, lantern carriage suitable to install Minimum 8 Nos. 350 W LED luminaries in asymmetrical arrangement, double drum winch, 6 mm diameter SS wire rope, Two number 5C X 2.5 Sq.mm tinned unarmoured copper conductor EPR insulated & PVC sheathed trailing cable from Junction Box of lantern carriage to control panel, one number 3CX4 Sq.mm, PVC insulated, PVC sheathed unarmoured Copper conductor cable for Power tool from control panel, connectors, 415 V, 32 A, 3P+N+E Plug & Sockets, integral power tool motor with mechanically tripping facility & manual handle, terminations Junction Box, lightening finial including the followings.High mast tower shall conform to tender specification & as required complete in all respects. Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template. Construction of shallow foundation with M25 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour. Erection of the high mast including all accessories with the help of suitable tools and plants. Installation, testing and commissioning of 350 W LED Flood lights upto 8No's or as per site requirements and 01 No. Twin Type aviation obstruction light on the existing lantern carriage including wiring of all luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 2.5 sq. mm from Junction Box of Lantern Carriage to individual light fittings, lugs, mounting accessories and all labour etc.
Design,Fabrication, Supply, Installation, Testing and commissioning of High mast shaft of 08 mtrs in single sections hot galvanized Steel plates confirming to BSEN 10025:1993 suitable for wind speed as per IS:875,part 3 with raising lowering system comprising, head frame, lantern carriage suitable to install Minimum 8 Nos. 350 W LED luminaries in asymmetrical arrangement, double drum winch, 6 mm diameter SS wire rope, Two number 5C X 2.5 Sq.mm tinned unarmoured copper conductor EPR insulated & PVC sheathed trailing cable from Junction Box of lantern carriage to control panel, one number 3CX4 Sq.mm, PVC insulated, PVC sheathed unarmoured Copper conductor cable for Power tool from control panel, connectors, 415 V, 32 A, 3P+N+E Plug & Sockets, integral power tool motor with mechanically tripping facility & manual handle, terminations Junction Box, lightening finial including the followings.High mast tower shall conform to tender specification & as required complete in all respects. Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template. Construction of shallow foundation with M25 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour. Erection of the high mast including all accessories with the help of suitable tools and plants. Installation, testing and commissioning of 350 W LED Flood lights upto 08 No's or as per site requirements and 01 No. Twin Type aviation obstruction light on the existing lantern carriage including wiring of all luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 2.5 sq. mm from Junction Box of Lantern Carriage to individual light fittings, lugs, mounting accessories and all labour etc.
Supply of LED flood light luminaire with secondary optical lens having minimum output of 38500 lm and rated power not exceeding 350 watts with 5 years warranty designed with Powder coated Pressure Die Cast aluminium housing, frame , MS mounting bracket, integral driver with Surge protection, heat resistant toughned glass, Conforming to IP 65/IP66 protection etc. complete as required. (LED & Power Drive Should meet the AAI Specifications)
Supply of Twin type aviation dome obstruction LED light fitting comprising of aluminium housing and polycarbinate diffuser suitable for operation on 230V;50Hz AC single phase power supply etc. complete as required.
Design, Supply, Installation, Testing and commissioning of weather proof, vermin proof, powder coated, free floor standing, fully compartmentalised , bottom entry double door type , outdoor canopy type , MV cubicle Electrical Main Feeder Piller panel, generally conforming to IP-55 and higher, fabricated from 2 mm. thick CRCA sheet , treated through seven tank process along with detachable 3mm thick gland plate sutable for operation on 415 V, 3 phase , 4 wire, 50 Hz AC supply, TPN aluminium busbars of high conductivity, DMC/SMC busbar supports with bottom base channel made out of MS section not less than 100 mm x50 mm x 5 mm thick, entire panel shall have a common copper earthbar of size 20mm X 5 mm at the rear with 2 Nos. earth studs ,solid connection from main busbar to switchgears with required size of aluminium busbar & control wiring with 2.5 sqmm FRLS insulated copper conductor cable, cable alleys, lifting hooks including swapping, recoiling and handling of all incoming and outgoing cables, Civil work for CC foundation, cutting , fixing, grouting, painting and sign writing etc. complete as required. Incomer : 400A, FP,36kA MCCB (Ics=100%Icu) with O/L and S/C fault Protection with Adjustable Thermal magnetic release with front operated rotary handle - 02 nos. Buscoupler : 400A, FP,36kA MCCB (Ics=100%Icu) with with O/L and S/C fault Protection with Adjustable Thermal magnetic release with front operated rotary handle - 01 No. Mechanical Interlock with 3 lock 2 key - 1 set Busbar:500 A, Al - Bus bar, Four pole with Fibre glass insulated support & pvc sleave etc-1set Out goings 160, FP, 25kA MCCB (Ics=100%Icu) with Thermal magnetic release having O/L & S/C protection with rotary handle - 2 Nos 125A, FP, 25kA MCCB (Ics=100%Icu) with Thermal magnetic release having O/L & S/C protection with rotary handle - 2 Nos 63A, FP, 'C' curve, 25kA MCCB (Ics=100%Icu) with Thermal magnetic release having O/L & S/C protection with rotary handle - 8 Nos Metering: Digital Multifunction meter, 3 phase, 5A, class -1 with CTs (400/5) = 02 set(for incomers). LED Phase Indication lamp with control MCBs - 02 Set's ON-OFF indication lamps (LED type) -14 sets
Design, Supply, Installation, Testing and commissioning of weather proof, vermin proof, powder coated, free floor standing, fully compartmentalised , bottom entry double door type , outdoor canopy type , MV cubicle Feeder Piller panel (Junction Box ), generally conforming to IP-55 and higher, fabricated from 2 mm. thick CRCA sheet , treated through seven tank process along with detachable 3mm thick gland plate sutable for operation on 415 V, 3 phase , 4 wire, 50 Hz AC supply, TPN aluminium busbars of high conductivity, DMC/SMC busbar supports with bottom base channel made out of MS section not less than 100 mm x50 mm x 5 mm thick, entire panel shall have a common copper earthbar of size 20mm X 5 mm at the rear with 2 Nos. earth studs ,solid connection from main busbar to switchgears with required size of aluminium busbar & control wiring with 2.5 sqmm FRLS insulated copper conductor cable, cable alleys, lifting hooks including swapping, recoiling and handling of all incoming and outgoing cables, Civil work for CC foundation, cutting , fixing, grouting, painting and sign writing etc. complete as required. Incomer : 400A, FP,36kA MCCB (Ics=100%Icu) with O/L and S/C fault Protection with Adjustable Thermal magnetic release with front operated rotary handle - 01 no. Busbar:500 A, Al - Bus bar, Four pole with Fibre glass insulated support & pvc sleave etc-1set Out goings 400, FP, 36kA MCCB (Ics=100%Icu) with Thermal magnetic release having O/L & S/C protection with rotary handle - 01 No 250A, FP, 36kA MCCB (Ics=100%Icu) with Thermal magnetic release having O/L & S/C protection with rotary handle - 01 No 63A, FP, 'C' curve, 25kA MCCB (Ics=100%Icu) with Thermal magnetic release having O/L & S/C protection with rotary handle - 01 Nos Metering: Digital Multifunction meter, 3 phase, 5A, class -1 with CTs (400/5) = 01 set(for incomer). LED Phase Indication lamp with control MCBs - 01 Set's ON-OFF indication lamps (LED type) -03 sets
Design, Supply, Installation, Testing and commissioning of weather proof, vermin proof, powder coated, free floor standing, fully compartmentalised , bottom entry double door type , outdoor canopy type , MV cubicle Electrical Outdoor panel( At CARGO Department), generally conforming to IP-55 and higher , fabricated from 2 mm. thick CRCA sheet , treated through seven tank process along with detachable 3mm thick gland plate sutable for operation on 415 V, 3 phase , 4 wire, 50 Hz AC supply, TPN aluminium busbars of high conductivity, DMC/SMC busbar supports with bottom base channel made out of MS section not less than 100 mm x50 mm x 5 mm thick, entire panel shall have a common copper earthbar of size 20mm X 3 mm at the rear with 2 Nos. earth studs ,solid connection from main busbar to switchgears with required size of aluminium busbar & control wiring with FRLS insulated copper conductor cable, cable alleys, lifting hooks including swapping, recoiling and handling of all incoming and outgoing cables, Civil work for CC foundation, cutting , fixing, grouting, painting and sign writing etc. complete as required. Incomer : 100A, FP,25kA MCCB (Ics=100%Icu) with with O/L and S/C fault Protection with Thermal magnetic release with front operated rotary handle - 01 nos Busbar:125A, Al - Bus bar, Four pole with Fibre glass insulated support & pvc sleave etc-1set Out goings 63A, FP, 25kA MCCB (Ics=100%Icu) with Thermal magnetic release having O/L & S/C protection with rotary handle - 05 Nos Metering: Digital Multifunction meter, 3 phase, 5A, class -1 with CTs (100/5) = 01 set(for incomer). ON-OFF indication lamps (LED type) with Control Fuse/MCB's -7 sets LED Phase Indication lamp with control MCBs - 1 Set.
Supply of following size cables of grade 1.1 KV, XLPE insulated, PVC sheathed, armoured Aluminium conductor conforming to IS 7098 (Part 1) amended upto date.
3.5C X 400 Sqmm
3.5C X 50 Sqmm
4C X 35 Sq mm
Supply and making end termination with brass compression gland and aluminium lugs for XLPE Insulated and PVC sheathed aluminium conductor cable of 1.1 KV grade and sizes as required for the following.
3.5C X 400 Sqmm
3.5C X 50Sqmm
4 C X 35 Sq mm
Supplying of following size , DWC HDPE pipe, ISI marked conforming to IS 14930 Part II with upto date amendments etc.complete as required.
125mm Dia(outer)/107mm Dia (inner)
63mm dia(outer)/50 mm Dia(inner)
Laying of following size DWC HDPE pipe Complete with all fitting & couplers direct in ground (75 cm below ground level) including excavation and refilling the trench after laying Pipe etc., complete as required.
125mm Dia(outer)
Upto 63mm Dia(outer)
Providing, laying and fixing following dia G.I. pipe (medium class) complete with G.I fittings direct in ground (75 cm below the ground level) including excavation and refilling the trench after laying G.I Pipe etc.complete as required.
125 mm dia
50 mm dia
Providing, laying and fixing following dia G.I. pipe (medium class) complete with G.I fittings in the existing excavated trench etc. complete as required. 50 mm dia
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as reqd.
a) Above 185 sqmm upto 400 sqmm
b) Above 35sqmm upto 90 sqmm
c) Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct/Cable trench as required. Above185 sqmm upto 400 sqmm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface/CableTray as required. Above 185 sqmm upto 400 sqmm
Supply and making of straight through joint with heat shrinkable kit including ferrules and other insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5CX 400 sqmm
3.5CX 50 sqmm
4CX35 sqmm
Supply, installation, testing and commissioning of the following rating and breaking capacity Ics=100%Icu, thermal magnetc release 4P MCCB with spreader terminals and extended rotary handles fixed on existing compartment of MV Panel including providing suitable rating Aluminium Busbar to connect with common busbar and to receive out going cables and making connections etc., complete as required. 630A, 50KA
Supplying and drawing of 2cx2.5Sqmm FR PVC insulated copper conductor,multi core cable in the existing surface/ recessed steel/ G.I conduit as required.
Supplying and laying of 20mm dia G.I conduit along with accessories direct in ground (50 cm below ground level) including excavation and refilling the trench after laying Pipe etc., complete as required.
Earthing with G.I. earth pipe of 4 metre long, 40 mm dia including accessories, and providing 300x300x450(H) mm RCC earth pit chamber suitable to receive 6mm thick MS chequered plate with handle, strengthening & compaction of soil below the earth pit chamber including providing suitable ratio PCC, providing & laying Plain Cement Concrete (PCC) (1:2:4) of depth 100mm surrounding the earth pit chamber covering surface area of 01 SqMeter,including providing and fixing of reducer, water funnel with wire mesh arrangement for watering etc. with charcoal/coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories and providing 300x300 X 450(H) mm RCC earth pit chamber suitable to receive 6mm thick MS chequered plate with handle, strengthening & compaction of soil below the earth pit chamber including providing suitable ratio PCC, providing & laying Plain Cement Concrete (PCC) (1:2:4) of depth 100mm surrounding the earth pit chamber covering surface area of 01 SqMeter,including providing and fixing of reducer, water funnel with wire mesh arrangement for watering etc. with charcoal/coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc.as required.
Providing and fixing 25mm x 5mm GI strip on surface or in recess from earth electrode to electrical panel/Highmast as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 Sets of G.I. nut bolt & spring washer spaced at 50mm)
Excavation of existing Bituminous/ Concrete road to facilitate laying of GI pipe including disposal of material within 50 Meters lead and providing & layinjg in position 1:2:4 (1 cement : 2 Coarse sand : 4 Graded stone aggregated of 20 mm nominal size all works up to plinth level to fill up the excavated trenches after laying of the GI pipe complete above as required.
SITC of LED vechicular Road traffic signal lights made of polycarbonate body with IP-65 protectedl, having 300mm dia, full circle, 2 Nos (RED & Green Colour) LED Lights, UV stablized polycarbonate lens, waterproof sealed gasket including providing 1.8 meter,75 mm dia high mountng G.I pole with brackets,clamps & painting with suitable colour, Civil foundation work and operating voltage of 230V AC, 50Hz etc as required.
SHRI KARNI LIGHT HOUSE
JAYRAM INDUSTRIES INDIA PRIVATE LIMITED
Ruchira Associates
Manoprabha Electricals
C R ELECTRICALS
Vardhman Airport Solutions Pvt Ltd
Kripa Electronics india pvt ltd
S. N. ELECTRIC & MAINTENANCE PRIVATE LIMITED
jaydeep agency corporation
Inovonz Engineering Pvt Ltd
ENERGYGREEN TECHNOPOWER PVT LTD
KALKI ELECTRICALS
RVD INFRA SOLUTION PVT.LTD.
METRO ENGINEERS SERVICES
A Goverdhan
ECS ENGINEERING PVT LTD
vk sam engineering
VISHAL ELECTRICALS
BR Power Control and Automation Services
Mukherjee Commercial Enterprise
LAKSHMI ELECTRICAL ENTERPRISES
Manish Electricals
SRI RAGHAVENDRA ELECTRICALS
Industrial Traders
Rekha Enterprises
SRINIVASA ELECTRICALS
stage.html
html • 0.12 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .